PT. ALSUN SUKSESINDO 1 FLOORDECK I

Upload: tranque

Post on 04-Feb-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLOORDECK I - · PDF filepositif searah yang sangat kokoh adalah bentuk V ... ALSUN - FD 600 is a supporting material plate ... equivalent moment of inertia for multiple span deflection

PT. ALSUN SUKSESINDO

1

FLOORDECK I

Page 2: FLOORDECK I - · PDF filepositif searah yang sangat kokoh adalah bentuk V ... ALSUN - FD 600 is a supporting material plate ... equivalent moment of inertia for multiple span deflection

ALSUN FLOOR DECK FD - 600

ALSUN - FD 600, terbuat dari plat baja kekuatan tinggi dan digalvanis secara sempurna (sistem celup panas), digunakan sebagai material pendukung plat baja dan beton komposit. ALSUN FD - 600 berfungsi ganda, yaitu sebagai bekisting tetap dan tulangan positif searah secara bersamaan.

Plat panel berkualitas tahan tekuk dengan tebal keseluruhan 0,75mm. Panjang plat dapat dipesan sesuai kebutuhan. Panjang maksimum yang dianjurkan 12 meter dengan pertirnbangan kemudahan pada saat pemasangan dan transportasi.

Keuntungan menggunakan ALSUN FD - 600:

1. Pemasangan yang mudah dan cepat: Menggunakan ALSUN FD - 600 berarti mernasang bekisting. tetap pada area yang luas dengan menggunakan waktu, biaya, dan perancah yang sedikit.

2. Sebagai pengganti tulangan positif searah: Hal yang membuat panel berperan sebagai tulangan positif searah yang sangat kokoh adalah bentuk V pada rusuk - rusuk panel ALSUN - FD 600 yang membuat panel tertanam didalam beton dengan kokoh,

ALSUN FLOOR DECK FD = 600 ALSUN - FD 600 is a supporting material plate made by high tensile galvanized steel plate. It functions as a cover and a direct positive bar. The plate panel is formed by specialized steel plate with thickness of 0.75 mm and has been processed by continuous hot deep galvanized. The length of this plate is flexible fitting the order placement. The recommended maximum length is 12 meters considering easing installation and transportation.

Benefit of Using ALSUN - FD 600

1. Quick and easy installation: Using ALSUN - FD 600 means installing permanent cover on extensive area with minimum cost, time, and props usage.

2. As a replacement of direct positive bar: V form panel sides of ALSUN - FD 600 will hold to the concrete firmly, that makes the panel as a very strong direct positive bar.

3. Durable Material Terbuat dari baja berkuatan tinngi- dengan kekuatan leleh 5500 kg / cm2 membuat ALSUN - FD 600 tidak mudah rusak pada saat melakukan instalasi dan transportasi.

4. Tahan Api ALSUN FD - 600, berperan sebagai material pelindung terhadap api & dapat dipadukan dengan material tambahan lain sebagai pelindung api.

3. Durable Material ALSUN - FD 600 is formed by high tensile steel plate with minimum yield stress 550MPa. ALSUN - FD 600 is not easily damaged while it is being installed or transported and it has a greater margin of safety in designing stage.

4. Fire Resistance By using ALSUN - FD 600, the concrete construction would stand the fire; protective material could be placed under the plate to level up the fire resistant.

Page 3: FLOORDECK I - · PDF filepositif searah yang sangat kokoh adalah bentuk V ... ALSUN - FD 600 is a supporting material plate ... equivalent moment of inertia for multiple span deflection

SPECIFICATI IN & TABLE SPESIFIKASI & Ti L

SPECIFICATION ALSUN Floor Deck FD - 600 adalah bahan lembaran panel berbentuk plat gelombang yang terbuat dari baja struktural bermutu tinggi dengan High-tensile steel JIS 3302 (570 N/mm2), dan berfungsi sebagai bekisting tetap dan penulangan positif satu arah pada lantai beton bangunan bertingkat. Tebal bahan yang tersedia adalah 0.75 mm dan 1.00 mm dengan lapisan seng minimum 220

grIm2

TABEL SIFAT PENAMPANG PANEL SECTION TABLE TABEL 1 : SIFAT PENAMPANG PANEL ALSUN FLOOR DECK FD - 600 PERLEBAR 1000 HM TABEL 2 : ALSUN FLOOR DECK FD - 600 PANEL SECTION PROPERTIES PER 1000 WIDTH

Caratan 1p= momen lnersial profit panel untuk daerah rnomen p o s ~ t ~ f Notes second moment of area of panel profile for positive mement reglons

In = Idem untuk daerah momen negat~f ltegangan tank)

~dem for negative moment regions

TEBAL PLAT

BASE STEEL THICKNES

mm

0.75

Znt = momen fahanan puncak rusuk dalam daerah momen negatlf (tegangan tarlk)

resistant moment top of nb negative moment regions (tensile stress)

le

lo6xmm4

0.425

le = moment iners~a ekivalen untuk perhltungan lendutan bentrng menerus equivalent moment of inertia for multiple span deflection calculations

= lp 11.26 - 0.26 Iplln)

BERAT per SANAN LUAS

MASS per UNrr AREA

kg/m2

10.1

Znc = rdem.dasar dek dalam daerah momen negat~f (tegangan tekan)

~dem bettom pan negatlve moment reglons (compressive stress)

Zpr = idem. puncak rusuk dalam daerah momen positif (tegangan tekan)

idem. top of rib positive regions (compressive stress

LUAS PENEMPANG

CROSS SECTION AREA

mm2

1241

GAYA REAKSI AMAN UMUK PERLETAKAN TEPI

SAFE END REACTION

Zpl = idem aasar dek dalam daerah moment posltlf (tegangan tarikl idem bottom pan poslttve moment reglons ltersile stress)

GAYA REAKSI AMAN UNTUK PERLETAKAN TENGAH

SAFE INTERNAL REACTION

100 ,Tulang Baja

Tebal Pelat Slab micknesQ

=- -1 11- 12 20 -1 $="-I I--= --I I- * L.b.rwd*Bulm600 60

~."msoowiarvMih

MAX

KN

8.11

lOmm PERLETAKAN

10 mm OF BEARING

KN

15.01

10 m m PERLETAWN

10 mm OF BEARING

KN

3.76

TABEL PERENCANAAN PRAKTIS PRACTICAL DESIGN TABLE

pENUH FOR FULLY

EFFErIVE SECTION

PERTAMBAWIN per 10 mm

INCREM per lomm

KN

0.99

BENTANG BEBAN HlWPlsFRGUNA &g/m$) I 1 TUMGGAi ' . . , . I MO I 3.00.: 1 400 1 mu

YC

mm

38.6

lOmm PERLETAKAN

INCREM per l o m m

KN

1.14

Catatan Beban mah (%rat sendlri ALSUN - FO 600 dan pelat beton) sudah d~perhltungkan Catatan Mutu Bala U-39 Notes Dead Load (Mass of ALSUN - FD 600 and Concrete Slab) are already calculated Mutu Beton K-2000

Yt

mm4

15.4

MOMEN LENTUR POSmF POSmVE BENDING MOMENT

MKT£RTARlK PAN INTENSION

MAX

KN

19.19

Ip

106xmm

0.511

MOMEN LEMUR NEGATlF NEGATNE BENDING MOMENT

DEKTERTEKAN PAN IN COMPRESSION

In

104xmm4

0.309

Zpc

1 0 ~ ~ ~ 2

13.15

Z ~ C

1 h m 2

10.21

Zpt

103xmm3

33.14

Znt

l d x m 2

10 73

Page 4: FLOORDECK I - · PDF filepositif searah yang sangat kokoh adalah bentuk V ... ALSUN - FD 600 is a supporting material plate ... equivalent moment of inertia for multiple span deflection

PEMASANGAN ALSUN FLOOR DECK FD - 600

ALSUN FD - 600 dapat dipasang pada: Portal konstruksi beton. Portal konstruksi baja. Konstruksi susunan batu bata.

1. ALSUN - FD 600 tersedia dalam ukuran 12 meter atau lebih. Panjang minimum yang dipesan minimal harus dapat menutup 2 - 3 bentangan.

2. Simpul antar panel harus diminimalisasi. 3. ALSUN - FD 600 berfungsi sebagai bekisting

yang aman pada saat beton masih basah, namun demikian konsentrasi beban tetap harus dicegah. Daerah yang merupakan jalur

Pemasangan pada konstruksi beton:

1. ALSUN FD - 600 harus dipasang sebagai bentangan tunggal diantara 2 tumpuan pada saat balok tumpuan bertindak sebagai balok T dan pengecoran dilakukan bersamaan dengan lantai. Ujung - ujung panel harus dimatikan / dipaku dengan paku beton hingga masuk pada bekisting kira - kira 2,5 cm.

2. Pada saat ALSUN FD - 600 dipasang sebagai bentang menerus and dan balok tumpuan dicor pada waktu yang berbeda maka stek / angkur harus ditanam pada balok tumpuan. Buatlah lubang pada panel tepat pada stek / angkur tersebut. Angkur / stek dimasukkan melalui lubang ini, kemudian dibengkokkan dan dimatikan / paku dengan menggunakan paku beton. (Lihat Gambar A)

Gambar A

INSTALLING ALSUN FD = 600

You can install ALSUN FD - 600 on: Concrete construction portal. Steel construction portal. Brickwork construction.

1. ALSUN - FD 600 is available in 12 meters size or more. Minimum length ordered should cover at least 2 spans.

2. The distance between the joints must be minimized.

3. ALSUN - FD 600 functions as a cover for wet concrete, but still must avoid excessive concentrated load. The concentrated load and heavy traffic area must be concreted immediately.

Installation on concrete construction:

1. ALSUN FD - 600 must be installed as a single span between 2 spans when the supporting beam acts as a T beam and cast in the same time with the floor. Using the concrete nail, the end of panels must be nailed / fixed (protrude up to approximately 2,5 cm) to the beam or bearing wall.

2. When ALSUN FD - 600 installed as continuous span and the supporting beam cast separately, a built - in anchor must be set on the supporting beam. A hole is made on the panel exactly on the anchor. The anchor penetrates through this hole, then b e d s and fixes the anchor with concrete nail to the beam. (See picture A)

Tulan an N attf Sesual Kebutuhan Tulan an Negatlf Sesuai Kebutuhan ~ega8ve ~%orcemencar Requlred

Tulanpan Susut ~ega8ve Re!nfommcnt as Required

Secondam I I

Page 5: FLOORDECK I - · PDF filepositif searah yang sangat kokoh adalah bentuk V ... ALSUN - FD 600 is a supporting material plate ... equivalent moment of inertia for multiple span deflection

ALSUN FLOOR DECK FD 600 1NSTALLATION PEMASANGAN ALSUN FLOOR DECK FD - 600

Pemasangan pada portal konstruksi baja: ALSUN - FD 600 dipasang setelah konstruksi baja sudah di lot dan di waterpas. Pada umumnya panel digunakan sebagai bentangan menerus pada balok tumpuan dan disambung dengan menggunakan ikatan las listrik, atau paku tembak. (Lihat Gambar B)

Gambar B

Installation on steel portal construction:

ALSUN - FD 600 is installed once the steel portal fit and placed level. The panel is generally used as continuous span on supporting beam and joined by electrical welding or nail shot or thumb tack. (See Picture B)

Tulangan NegarHSesvai kebutuhan

BL~,:u.. p-ngakhiran biara/Typical conventional ending Bentuk tumpuan gandaiTyplca1 double support BenWk tpengakhiran konrcVTypicai cantilever end

Penggunaan Las Listrik Di ujung panel ALSUN - FD 600, pada bagian yang

rata, harus di las dengan diameter minimal 1 cm. Dengan menggunakan kawat las berkekuatan tinggi

yang berdiameter 3,25 mm dan terbuat dari baja selulosa ACIDC, bagian tumpuan tengah yang rata di las pada setiap bagian sebaliknya.

Penggunaan Paku Tembak Gunakan paku tembak dengan diameter 4 m m dengan panjang yang sesuai. Pemasangan penahan geser yang dilas di atas balok tumpuan diperlukan pada saat balok tumpuan berperan sebagai balok T komposit. (Lihat Gambar C)

By Welding System The end support parts of ALSUN - FD 600, the

flat part, must be welded with 1 cm minimum diameter.

At the interior support, the panel must be welded to each reverse side using high quality welding wires of 3,25 mm and made by AC/DC cellulose steel.

By Nail Shot or Thumb Tack Using nail shot or thumb tack of 4 mm diameters with suitable length is required. When the supporting beam acts as T composite beam, i t is necessary to install a shearing

Gambar c I

Penjelasan pada panel diatas turnpuan tengah I Welding at interior suppott panel

Page 6: FLOORDECK I - · PDF filepositif searah yang sangat kokoh adalah bentuk V ... ALSUN - FD 600 is a supporting material plate ... equivalent moment of inertia for multiple span deflection

PENGECORAN DAN PENYELESAIAN AKHIR Persiapan Pengecoran

1. Lakukan penutupan pada gap antara sisi - sisi ALSUN FD - 600 dengan menggunakan pita perekat.

2. Untuk memperoleh sambungan panel yang baik dan dasar panel yang rata, maka sisi - sisi rusuk panel harus disambung secara sempurna, dengan maximum jarak 1/20 meter. Alternatif yang dapat digunakan: . - Las Cantum

- Rivet 5 m m dia. - Sekrup Self drilling / tapping dengan ukuran 10 X

16 m m S point hex head Type or Teks wafer head type.

3. Jika penahan geser diperlukan, maka penahan geser harus dilas atau ditanam melalui panel ALSUN FD - 600 ke balok tumpuan. Jarak minimum antara bagian atas penahan geser dengan permukaan beton kira - kira 25 m m dan harus dihitung dengan meng- gunakan gaya lintang balok.

CONCRETING AND FINISHING Concreting Preparation

1. Conceal the gap between the ALSUN FD. - 600's side using glue tape.

2. To have a well connection and level panel's base, the side's end is required to be joined, with 1/20 meters maximum distance, by using alternatives such as:

- Stick welded - Riveted by 5mm dia. - Self drilling / tapping screw in size of 10X16mm

S point hex head Type or Teks wafer. head type. 3. I f a shear connector is required, the connector must

be anchored or welded through the ALSUN FD - 600 panel into the supporting beams. The minimum distance between the top shear connector to the concrete surface is approximately 25 mm and calculated using the beam shear force diagram.

1 1 Penahan Geser/Shear Connector Selp tapplng 8 drllllng screw (10x6)

1 L

4. Tiang penyangga sementara. Tiang penyangga sementara digunakan pada saat pengecoran ALSUN FD - 600. Tiang penyangga sementara dapat dilepas setelah 7 - 14 hari, ha1 ini tergantung dari beban dan pemeliharaan pasca pengecoran.

5. Besi Tulangan. Penggunaan besi tulangan bertujuan untuk men- cegah keretakan akibat dari perubahan suhu dan untuk pemeratan beban. Untuk plat beton dengan tebal 9 - 12 cm digunakan wiremesh dia.. 5mm, jika pelat beton lebih besar dari 12 cm digunakan Wiremesh dia. 6mm.

6. Penggunaan material aditif tambahan. Cegah penggunaan zat tambahan yang mengandung calcium chlorida karena dapat merusak lapisan

Pengecoran:

galvanis.

1. Pasang papan untuk digunakan sebagai jalur lalu - lintas pekerja dan troli.

2. Pastikan tidak ada penumpukan beton pada saat pengecoran.

3. Pastikan beton di cor secara merata dan besi tulangan wire harus diposisikan kira - kira 2 cm di bawah permukaan beton.

4. Kualifikasi kekuatan beton adalah K200 pada saat umur beton 28 hari.

- Dianjurkan menggunakan beton curah. - Pada saat beton dipadatkan secara manual maka

nilai slump - nya 7,5 - 10 cm. - Pada saat beton dipadatkan dengan alat

penggetar, maka nilai slump - nya 5,O - 7,5 cm.

4. Temporary propping: The temporary propping is used when casting the ALSUN - FD 600. T propping is released in 7 to 14 days, depending on the load and the maintenance of the concrete after the casting.

5. Secondary Reinforcement I n order to avoid crack due to temperature changing and to uniformly distribute concentrated loads. For slabs 9 - 12 cm thick use wire mesh with 5 mm dia. and for slab 13 - 15 cm use wire mesh with 6 mm dia.

6. Additive Material Usage Prevent using additive material with calcium chloride, which can ruin the galvanized layer.

Concreting:

1. Use floorboards for the workers and concrete trolley traffic.

2. Ensure that there is no concrete concentrated at certain place.

3. The concrete must be evenly cast and the secondary reinforcement must be positioned 2 cm below the concrete bottom.

Page 7: FLOORDECK I - · PDF filepositif searah yang sangat kokoh adalah bentuk V ... ALSUN - FD 600 is a supporting material plate ... equivalent moment of inertia for multiple span deflection

Penyelesaian Akhir

Pada tahap penyelesaian bagian dasar panel ALSUN FD - 600, penyelesaian dapat dilakukan sesuai dengan kebutuhan interior; diantaranya :

1. Fungsi Terbuka Bagian dasar ALSUN FD - 600 dapat digunakan secara langsung sebagai langit - langit yang menarik dengan menggunakan cat, koraltex, dan lain - lain.

2. Fungsi Tertutup Harus dipersiapkan penggantung rangka langit - langit pada panel ALSUN FD - 600 jika menginginkan penutupan dengan langit - langit. Hal ini dilakukan dengan cara:

- Meletakkan penggantung pada celah - celah rusuk panel.

- Sebelum melakukan pengecoran, pasang terlebih dahulu angkur yang menembus panel.

4. Qualified concrete compressive strength is K200 at 28 days. - Ready mix is recommended - When the concrete mix is manually

compacted, the slump value is 7,5 - 10 cm. - When the concrete mix is vibrated

compacted, the slump value is 5 - 7,5 cm.

Finishing

Completion of the bottom side of ALSUN FD - 600 panel can be completed according to desired interior design, such as:

1. Open Functioning The bottom side of ALSUN - FD 600 can directly. use as ceiling, which is attractive (by paint, koraltex, etc)and cost-effective.

2. Close Functioning You have to prepare the ceiling hangers when you want to close the ceilings, by:

- Placing hanger at the ALSUN FD - 600's edge groove.

- Before concreting, put in the anchor into the ALSUN FD - 600's panel