FLoWSic600 ultrasonic Gas Flow meter
� SicK maiHaK | FLoWSic600 FLoWSic600 | SicK maiHaK �
1tv
1tr
L2 • cos α
v = • ( )Q = v •
4D2• π
FLOWSIC600 – benefits at a glance
Bi-directional measurement, no pressure dropPath layout without reflectionHigh efficient transducersLess sensitive for ultrasonic noiseWide measuring range up to 1:120No damage when overrangedIntegrated logbook and 4 volume countersIntelligent self diagnosisLow power consumption <1 WCalibration with air at atmospheric pressure possible
••••••••••
Operating principle
Two ultrasonic transducers, which are installed under an angle to the flow axis, operate alternately as a transmitter and receiver. The signals transmitted through the gas ac-celerate in the direction of flow and decelerate against the direction of flow. The resulting difference in propagation times is used to determine the mean gas velocity. The cross-sectional area yields the volumetric flow during oper-ation. The measurement result is not affected by the pres-sure, temperature, or gas composition. To increase the ac-curacy of the measurement, the gas velocity is measured with multiple paths.
FLoWSic600For custody transferand Process applications
Many years of experience and conti-nuous improvement of the measuring technique have led to a new generati-on of ultrasonic gas flow meters – the FLOWSIC600. Already the visual im-pression shows the compact design with consealed cabling system which provides a trouble-free and low-main-tenance use under the harsh industri-al conditiones.
The FLOWSIC600 can be equipped with 1, 2 or 4 measuring paths that offers the usage from custody transfer applications up to measurements with less precision requirements. The stan-dard installation length of 3D allows to replace existing turbine meters without pipe readjustments. Because adjustable impulse outputs or Mod-bus connections are available, in-stalled flow computers can be used furthermore.
FLoWSic600 – applications
Custody transfer (fiscal metering)Check metering on- and offshoreAllocation metering offshoreUnderground gas storage (bi-directional)Power plants and other large industrial usersChemical and Refinery IndustryCryogenic gas applications up to –194 °C (-317°F)Process gases like N2, O2, H2, CO2, Cl2, Ethylene, etc.Gases with high content of H2S like sour gas or biogas
•••••••••
v = Gas velocityL = Path lengthα = Installation angleQ = Volume flowD = Diametertv = Transit time with flowtr = Transit time against flow
Ultrasonic transducer B
Ultrasonic transducer A
Flow
� SicK maiHaK | FLoWSic600 FLoWSic600 | SicK maiHaK �
Direct path layout – no reflection
The FLOWSIC 600 is designed as a direct path ultrasonic meter. Because the signals are not reflected inside the measuring pipe, contamination or changes in wall roughness do not affect the measurement characteristics or longterm stability of the measuring system. In addition, the layout of the measuring paths improves the signal-to-noise ratio. This makes the FLOWSIC600 substantially less sensitive to control valve noise.
redundancy
The FLOWSIC 600 can easily be extended to a redundant system. This can be achieved by adding a second electronics and associated transducers in the free part of the X-shaped measuring section. As a result, the main and the additional meter form a redundant system which is integrated in one meter body.
Extraction tool
Using this tool, the ultrasonic transducer can be exchanged under operational pressure. The FLOWSIC600 does not need to be switched off, and provides data furthermore.
mEPaFLoW600 software
The MEPAFLOW600 software as an important componentof the measuring system is the universal tool for parameterizationand diagnosis of the FLOWSIC600. It records, managesand saves all data provided by the electronics. On this basis, poten-tial equipment problems can be identified easily.
Key diagnosis featuresSignal qualitySignal-to-noise ratioSpeed of soundFlow profileProfile factorAsymmetryTurbulenceConfiguration change
Global support – one button diagnosis
All information you need to evaluate the status of the FLOWSIC600 can be stored in a file by clicking on one button. This file just send to one of our specialists - they will evaluate the data and inform you about required measures.
••••••••
� SICKMAIHAK | FLOWSIC600 FLOWSIC600 | SICKMAIHAK �
FLOWSIC600
The uLTraSOnIC (r)evOLuTIOn
6 SicK maiHaK | FLoWSic600 FLoWSic600 | SicK maiHaK �
FLoWSic600 technical data
meter characteristics
Meter size Flow rate in m3/h Flow rate in in ft3/h Max. velocity [m/s]
Length[mm]
Weight1)
[kg]Min. Max. Min. Max.
DN 50 2" 6 400 210 14,000 65 150 25
DN 80 3" 12 1,000 280 35,000 65 240 38
DN 100 4" 20 1,600 460 57,000 60 300 60
DN 150 6" 32 3,000 1,130 106,000 50 450 120
DN 200 8" 40 4,500 1,410 159,000 45 600 190
DN 250 10" 50 7,000 1,770 247,000 40 750 300
DN 300 12" 65 8,000 2,300 283,000 33 900 420
DN 350 14" 80 10,000 2,830 353,000 33 1,050 595
DN 400 16" 120 14,000 4,240 494,000 33 1,200 790
DN 450 18" 130 17,000 4,590 600,000 33 1,350 1,000
DN 500 20" 200 20,000 7,060 706,000 33 1,500 1,235
DN 600 24" 320 32,000 11,300 1,130,000 33 1,800 1,900
DN 700 28" 650 40,000 22,950 1,413,000 30 1,400 2,400
DN 750 30" 650 45,000 22,950 1,589,000 30 1,500 2,800
DN 800 32" 800 50,000 28,250 1,766,000 30 1,600 3,200
DN 900 36" 1,000 66,000 35,320 2,331,000 30 1,800 4,000
DN 1000 40" 1,200 80,000 42,380 2,825,000 30 2,000 5,150
DN 1050 42" 1,300 85,000 45,910 3,002,000 30 2,100 5,850
DN 1100 44" 1,400 90,000 49,440 3,178,000 28 2,200 6,600
DN 1200 48" 1,600 100,000 56,500 3,531,000 27 2,400 8,100
Material Meter size ≤DN 600/24" Meter body with flanges in steel 1.1120/ASME A216 WCC Meter body with flanges in stainless steel 1.4408/ASME A351 Gr. CF 8M
Meter size >DN 600/24" Meter body in steel 1.1120/ASME A216 WCC, flanges in ASTM A105 Meter body in stainless steel 1.4408/ASME A351 Gr.CF 8M, flanges in 1.4404/A182 Gr. F316L
measured medium
Gases Natural gas, process gases, air, Ethylene, etc.
Temperature –30 °C ... +180 °C (–22 °F to 365 °F); -194 °C to 280 °C (-317 °F to 536 °F) on request
Pressure range 0 barg to 250 barg (0 psig ... 3600 psi); up to 450 barg (6500 psi) on request
measurement uncertainty
Repeatability <0.1 % of reading
Typical uncertainty2) 1 measuring path: ±2.0 %
2 measuring paths: ±1.0 %
4 measuring paths: ±0.5 %, ±0.2 % after high pressure calibration
ambient conditions
IP-classification IP 67
Temperature range –40 °C to 60 °C (–40 °F to 140 °F)
1) valid for flange type #6002) Qt ... Qmax with straight inlet/outlet section 10D/3D or 5D/3D with flow straightener
FLoWSic600 data at a Glance
6 SicK maiHaK | FLoWSic600 FLoWSic600 | SicK maiHaK �
Power supply
Operating voltage 12 ... 28.8 V DC (minimum 15 V for active current output)
Typical power consumption <1 W
outputs
Measuring variables Flow rate (actual), volume (actual), gas velocity, speed of sound
Analog output 4 to 20 mA; active/passive; electrically isolated; max. load = 250 Ω
Pulse and status outputs passive, electrically isolated, open collector or NAMUR, fmax = 6 kHz (scalable)
interfaces
Modbus ASCII and RTU 2 x RS485 for configuration, measured value output and diagnosis
HART® Configuration, measured value output and diagnosis
Ex-approval
Europe (ATEX) II 1/2G EEx de ib [ia] IIA T4 or II 1/2G EEx de ib [ia] IIC T4
USA/Canada (CSA) Class I, Division 1, Groups D T4; Class I, Division 2, Groups D T4Class I, Division 1, Groups B, C, D T4; Class I Division 2, Groups A, B, C, D T4
Configuration 1 (without flow straightener)
Flow computer
Configuration 2 (with flow straightener)
Inlet section 10 D
D
¼" NPT
pT
1.5 D
3 D
Outlet section 3 D
Inlet section 5 D
a n a Ly z E r S a n d P r o c E S S i n S t r u m E n tat i o n
at H o m E i n t H E i n d u S t r i a L S E c t o r
We can build on years of expe-rience in the field of Analyzers and Process Instrumentation. That is why we are at home in the natural gas industry (pro-duction, transport, storage and distribution) as well as in the chemical or petrochemical industry. Be it custody meas-urements or simple monitor-ing tasks – we offer tailer-made solutions.
8009
840/
2007
-03
· DIV
03/K
E · P
rinte
d in
Ger
man
y (2
007-
03) S
ubje
ct to
cah
nge
with
out n
otic
e
SICK MAIHAK GmbH | Analyzers and Process Instrumentation Nimburger Str. 11 | 79276 Reute | Germany | www.sick-maihak.com Phone +49 7641 469-0 | Fax +49 7641 469-11 49 | [email protected]
Source: BP
W E o F F E r yo u a c H o i c E
SICK MAIHAK offers a number of sensor-based techniques for analysis, ranging from the con-tinuous gas and dust measure-ment to specialized applications for water and liquid analysis. Within the process measure-ment technology our products play a central role in determining volume flow of gases and level of bulk materials.
a r o u n d t H E W o r L d t o yo u r S E r v i c E
Where ever you are, our global network of subsidiaries and rep-resentatives is able to supply qualified support when you need it. We deliver the equipment for your measuring tasks, provide documentation and training. Our highly skilled service staff offers support during installation, com-missioning and maintenance of the appliances.
SicK GrouP
SICK MAIHAK represents the process automation segment of the SICK group, one of the worlds leading manufacturer of intelligent sensors and sensor solutions. With its 4,000 em- ployees, SICK offers an exten-sive portfolio of products and services on the market of fac-tory and process automation. www.sick.com