grating-coupled spr for rapid, label-free, array-based sensing

17
Grating-Coupled SPR for rapid, label- free, array-based sensing 指指指指 指指指 指指指 指指指 指指2004/06/30

Upload: rolf

Post on 04-Jan-2016

77 views

Category:

Documents


0 download

DESCRIPTION

Grating-Coupled SPR for rapid, label-free, array-based sensing. 指導教授:林啟萬 研究生:蘇明啟 日期: 2004/06/30. outline. Basis of grating-coupled SPR Structure of GC-SPR and Schottky Junction An experiment of GC-SPR Array-based GC-SPR Conclusion Reference. How does grating-coupled SPR occur. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Grating-Coupled SPR for rapid, label-free, array-based sensing

Grating-Coupled SPR for rapid, label-free, array-based sensing

指導教授:林啟萬研究生:蘇明啟日期: 2004/06/30

Page 2: Grating-Coupled SPR for rapid, label-free, array-based sensing

outline

Basis of grating-coupled SPR Structure of GC-SPR and Schottky Junction An experiment of GC-SPR Array-based GC-SPR Conclusion Reference

Page 3: Grating-Coupled SPR for rapid, label-free, array-based sensing

2

2

)sin(

'

amr

amra

xmx

n

nmn

kmGk

The sensitivity of prism-coupled SPR sensor is a little higher than that of grating-based SPR sensor. However, GCSPR has advantages of small size, cheap, suitable for portable design.

How does grating-coupled SPR occur

Page 4: Grating-Coupled SPR for rapid, label-free, array-based sensing

The fabrication process of gratingI.

1. Start with fabrication by holographically with an blue laser (488 nm) on GaAs substrate with doping level from 5x1016 to 5x1018 cm-3

2. The microstructure was revealed by AFM, which reconstructs the grating profile and determines groove depth and grating period.

3. Thermally evaporated metal (Au) films were deposited at room temperature.

II.

1. Exposing Shipley S1405-17 photoresist to two expanded collimated interfering beams of 457.9 nm radiation from an argon ion laser.

2. Hardened by exposure to ultra-violet radiation

3. Etched by an energetic atom beam to transfer the spatial profile in the photoresist through into the silica substrates.

Page 5: Grating-Coupled SPR for rapid, label-free, array-based sensing

Schottky Junction 由金屬和 N型半導體接合 接觸面上形成 Schottky ba

rrier 加入順向偏壓時, N型區的自由電子獲得足夠能量,而移到較大的軌道中移動,因此自由電子也能跨越接面而進入金屬區,造成大量順向電流。

導通電壓低 極低雜訊指數

Page 6: Grating-Coupled SPR for rapid, label-free, array-based sensing

Band Diagram of a Metal-Semiconductor Junction

Each material has a characteristic energy which is needed to remove an electron from its surface to infinity. This is called the work function of the material. When a high work function metal comes in contact with a semiconductor with a lower work function, electrons flow from the semiconductor to the metal. This results in a band configuration shown in Figure.

Page 7: Grating-Coupled SPR for rapid, label-free, array-based sensing

Schematic Diagram of GCSPR

period d=652 nm

height h~18 nm

Incident angle of P-polarized light is 18˚

Page 8: Grating-Coupled SPR for rapid, label-free, array-based sensing

Alcohol concentration in water (%)

1. 0

2. 7.3

3. 13.6

4. 19.2

5. 24.0

6. 28.3

incident angle vs short-circuit photocurrent

alcohol concentration vs angular shift

Page 9: Grating-Coupled SPR for rapid, label-free, array-based sensing

Make Use of Gratings on CD-ROM

Plastic molded transducers (grating chips)

Page 10: Grating-Coupled SPR for rapid, label-free, array-based sensing

Grating-Coupled SPR

Period is 867 nm

Groove depth is 40 nm

Page 11: Grating-Coupled SPR for rapid, label-free, array-based sensing

Simultaneous Measurement on Microarrays

Plastic Grating

Au Film (80 nm)

MUA+PLBiotin

avidin

MUA:

11-mercaptoundecanoic acid

PL: electrostatically adsorbed

Poly-L-lysine

Page 12: Grating-Coupled SPR for rapid, label-free, array-based sensing

SPR Curve: Incident angle vs Reflectance

Principle of operating of kinetic analysis system.

Light source: 867 nm LED SPR curves collected by CCD camera

Page 13: Grating-Coupled SPR for rapid, label-free, array-based sensing

Kinetic Calculations

Page 14: Grating-Coupled SPR for rapid, label-free, array-based sensing

Detection of Protein Binding

Spot size 250 um

1-cm2 containing 400 spots

Page 15: Grating-Coupled SPR for rapid, label-free, array-based sensing
Page 16: Grating-Coupled SPR for rapid, label-free, array-based sensing

Reference Jennifer M. Brockman, Salvador M. Fernandez, Grating-coupled surface

plasmon resonance for rapid, label-free, array-based sensing, American Laboratory, June 2001

N. L. Dmitruk, O. I. Mayeva, S. V. Mamykin, O. B. Yastrubchak, On a Control of Photo-surface Plasmon Coupling at a Multilayer Diffraction Grating, Institute for Physics of Semiconductors NAS of Ukraine, IEEE 2000

Dmitruk N.L., Mayeva O.I., Mamykin S.V., Fursenko O.V., Yastrubchak O.B., Influence of Multilayer Coating Peculiarities on Efficiency of Surface Plasmon Resonance Photodetector, Institute of Physics of Semiconductors NAS of Ukraine, IEEE 1998

R A Watts, J R Sambles, M C Hutley, T W Preist, C R Lawrence, A New Optical Technique for Characterizing Reference artefacts for Surface Profilometry, Thin Film Photonics Group, Department of Physics, University of Exeter, UK, National Physical Laboratory, Middlesex UK, Nanotechnology 8 (1997) 35-39

http://www.formosams.com http://nina.ecse.rpi.edu/shur/Ch3/sld043.htm http://solarwww.mtk.nao.ac.jp/kobayash/thesis/node34.html

Page 17: Grating-Coupled SPR for rapid, label-free, array-based sensing

Thanks for your attention!