hi-scan pro_ppt

Upload: ahmed-helmy

Post on 02-Jun-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 hi-scan pro_ppt

    1/26

    Hi-Scan Pro

  • 8/10/2019 hi-scan pro_ppt

    2/26

    1. Main Functions

    2. System Overview General

    3. Vehicle Diagnosis

    4. Tool Box

    5. Miscellaneous Functions

    Introduction of Hi-Scan Pro

  • 8/10/2019 hi-scan pro_ppt

    3/26

    Main Functions

    Diagnostic Communication with all kinds of vehicles

    OBD-II and International Protocol Support

    Hi-Speed 2 Channel Oscilloscope

    Advanced Multi-Meter Test Function

    - Voltage, Frequency, Duty, Resistance, etc.

    Actuator Driving test and Sensor Simulation

    PC Interface (PC-SCAN)

  • 8/10/2019 hi-scan pro_ppt

    4/26

    System Overview

  • 8/10/2019 hi-scan pro_ppt

    5/26

    Vehicle Diagnosis (Scan Functions)

    1. Diagnostic Trouble Codes

    2. Current Data

    3. Flight Record

    4. Actuation Test

    5. Simu-Scan

    6. Other Functions

  • 8/10/2019 hi-scan pro_ppt

    6/26

    Diagnostic Trouble Codes

    Display all DTC for the selected ECM

    DTC Erasing Function

    Abundant Tips Information for Repair

    Direct Link to Part Analysis

    On-line Operation Guide ( HELP )

    Function

    Shift + F6 = All Diag. code Display

  • 8/10/2019 hi-scan pro_ppt

    7/26

    Current Data

    Display Current Sensor ValuesAbundant Tips Information

    Data Recording Available even in

    Running Condition

    Graphic Mode Display

    Direct Link to Part Analysis

    Software Function Key support

    - FIX, PART, FULL, HELP,

    GRPH, RCRD

  • 8/10/2019 hi-scan pro_ppt

    8/26

    Flight Record

    Record Current Sensor Values up to 8items at once

    Graphic Display Review for the

    Recorded Data

    Memory Expansion to SupplementaryS-RAM Card

  • 8/10/2019 hi-scan pro_ppt

    9/26

    Actuation Test

    Allow each actuator to be

    forcibly driven by Hi-Scan

    Pro

    On-Line Testing Condition and

    Method Guide Support

  • 8/10/2019 hi-scan pro_ppt

    10/26

    Simu-Scan

    Display current data with direct

    sensor simulation and meter

    test simultaneously

    Voltage, Frequency & Dutysimulation

    Voltage, Frequency and Ohm

    meter test

  • 8/10/2019 hi-scan pro_ppt

    11/26

    Tool Box

    1. Part Analysis (Engine/Auto Transaxle)

    2. Symptom Analysis

    3. Troubleshooting Pack

    4. Oscilloscope (Normal Mode)

    5. Oscilloscope (Record Mode)

    6. Multi Meter

    7. Actuator Driving

    8. Sensor Simulation

  • 8/10/2019 hi-scan pro_ppt

    12/26

    Available Items

    - Engine : 39 Sensor Items

    - Auto T/A : 14 Sensor Items

    Auto-set DB support- Various levels of Oscilloscope

    parameters such as

    Voltage, Time division,

    Trigger point, etc.

    Part Analysis

  • 8/10/2019 hi-scan pro_ppt

    13/26

    Part Analysis

    Direct Part Trouble Diagnosis through Pre-Set Oscilloscope

    Function and Repair Information

    Easy & Direct Link from Any Mode

    - From DTC, Current Data and DVOM modes.

  • 8/10/2019 hi-scan pro_ppt

    14/26

    Easy-Traceable diagnostic flow per each trouble Symptom.

    Symptom Analysis

  • 8/10/2019 hi-scan pro_ppt

    15/26

    Combination Display with Part Analysis

  • 8/10/2019 hi-scan pro_ppt

    16/26

    Tips

    Provide basic and major information to help understand eachtrouble code and part.

    Troubleshooting Pack

  • 8/10/2019 hi-scan pro_ppt

    17/26

    Provide Regular or Irregular waveforms for reference.

    Waveform Reference

  • 8/10/2019 hi-scan pro_ppt

    18/26

    Provide Field experience for reference

    Case study

  • 8/10/2019 hi-scan pro_ppt

    19/26

    Circuit Diagram

    Shown in Hi-SCAN Pro

    Provide relevant schematic diagram for engine & Auto T/A.

  • 8/10/2019 hi-scan pro_ppt

    20/26

    Flow Chart

    Provide recommended diagnostic troubleshooting procedures

  • 8/10/2019 hi-scan pro_ppt

    21/26

    Oscilloscope ( Normal Mode )

    2 Channel Digital Storage ScopeSampling Speed : 1 Mhz / Sec

    Time Division : 20~50s

    Voltage Division : 0.2 V ~ 50V

    Selectable Trigger Functions

    (Mode / Source/ Level / Delay)Adjustable GND Level

    Hold current waveform on screen

    Cursor Data Display

    Waveform Zoom function

    (1x, 2x, 5x)

  • 8/10/2019 hi-scan pro_ppt

    22/26

    Oscilloscope (Record Mode)

    Larger Record Space

    - 128 KB continuous samplingavailable

    Video Replay View

    Trend View Functions (Average, Min-Max, Frequency, Duty)

    Hold current waveform on screen

    Cursor Data DisplayWaveform Zoom function

    (1x, 2x, 5x)

  • 8/10/2019 hi-scan pro_ppt

    23/26

    Multi Meter

    2 Channel Multi Meter

    Volt Meter : Max. 500VDC

    Frequency Meter: 0 ~ 100 KHz

    Duty Meter : 0 ~ 100 %

    Ohm Meter : 0 ~ 10

    Automatic Unit Conversion

    (Current Meter / Temperature

    Meter / Pressure Meter )

  • 8/10/2019 hi-scan pro_ppt

    24/26

    Actuator Driving

    Direct Actuator Driving throughCable

    Applicable Parameters

    - Frequency

    - Duty

    - Period

  • 8/10/2019 hi-scan pro_ppt

    25/26

    Sensor Simulation

    Direct Sensor Simulation

    Voltage Simulation : 0 ~ 5V

    Frequency Simulation : 0 ~ 100 Hz

    Duty Simulation : 0 ~ 100%

    Vehicle Speed Simulation

  • 8/10/2019 hi-scan pro_ppt

    26/26

    Miscellaneous Functions

    System Set up function

    Auto Self-Test Support

    Printer

    - Hi-Scan Pro Printer

    - Auto Check Printer

    - PC Printer by PC-SCAN

    Program

    PC Interface (RS232 Port)

    Program Downloading via

    Internet