hikvision video intercoms - mercury security · villa door stations 12v powered locally or 24v poe...

29
Hikvision Video Intercoms INTRODUCTORY TRAINING

Upload: phamnguyet

Post on 30-Aug-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Hikvision Video

IntercomsINTRODUCTORY TRAINING

Page 2: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Section one

HARDWARE

Page 3: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Villa Door Stations

12V Powered locally or 24V PoE via Hikvision PoE distributor unit – DS-KAD6XX or 24V PoE

switch / injector

Latest version firmware ver 1.4.71 – VIS 18 LPT1

Page 4: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Door Stations

DS-KD8012-V or DS-KD8002-VM D – Series. Multi user door station – Apartments

12V Powered locally. Minimum 15W PSU – 2Amp

Latest version firmware ver 1.4.71 – VIS 20 LPT1

Page 5: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Door Stations

DS-KB8112-IM Vandal Resistant Door Station

12V Powered locally or 48V PoE – Any 48V PoE switch

Latest version firmware ver 1.4.5 – Only one version of firmware at the moment. Upgrade not required.

Page 6: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Indoor stations

DS-KV8301-WT or DS-KV8301-T (no Wi-Fi)

12V Powered locally or 24V PoE via Hikvision PoE distributor unit – DS-KAD6XX or 24V PoE switch / injector

Latest version firmware ver 1.4.71 – VIS 20 LPT1

Page 7: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Accessories

Page 8: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Section two

PROGRAMMING

Page 9: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Software required

SADP(v3.0.0.10) & iVMS(v2.6.2.50 *special intercom version*)

Page 10: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 1 - Activation

Activate both units – door station and monitor. Please skip activation on

screen with DS-KH8301-WT. Recommended to activate via iVMS and

assign IP address, subnet mask with gateway according to the router.

Page 11: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 2 - iVMS

Add devices to iVMS Device Management

Page 12: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 2a

After correct user name and password devices should

appear on top section of iVMS with serial number and

green indicator on Net status section.

Page 13: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 3 - Firmware

Configuration - Door station Villa type DS-KV (1 Door to 1 monitor system)

Device management Remote Configuration

Check the version of firmware and upgrade to the latest version of firmware

1.4.71

Page 14: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 4 – Time settings

After rebooting door station, please set up time. Select the time zone.

We can use one of the NTP servers or just sync with PC.

Page 15: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 5 – Room number

Section IntercomDial

Set up the Room number as 1. (Unsupported intercoms version of iVMS

will not allow you put number 1 and need to use 101)

Page 16: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 5a

In case we have Door station with 2 or 4 Buttons. We have address other

buttons with correct room’s numbers. Number 2 to Room No 2 etc.

Page 17: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 6 - Volume

At that stage with system 1 to 1 our door station configuration is finished. If the

volume is too loud or too quiet you can adjust volume in section

IntercomVolume input/output

Page 18: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 6a – Conversation length

Or change time conversation parameters. IntercomTime parameters

Page 19: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 7 – Indoor station

Configuration Indoor Station - Monitor (1 to 1 system) Device management Remote Configuration

Check the version of firmware and upgrade to the latest version of firmware 1.4.71

The same procedure as Door station (STEP 3). After reboot indoor station please set up time. Select the time

zone the same like with Door station

Section IntercomDial

Set up the Room number as 1. (Unsupported intercoms version of iVMS which not allows you put number 1

need to use 101)

Page 20: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 7a - Network

NetworkLinked Network Configuration

Set up linked IP of the door station. (Main) Door Station IP Address (192.168.1.120 in our case) and change

Main Door Station Type to V series (Villa)

Page 21: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 8

If all the setting are correct on display of indoor station red icon with Door Station should change colour to

grey and should display – SIP!

At that stage our 1 to 1 system should up and running with basic configuration.

Page 22: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 9 – Hik Connect

In case system will be online and customer will be require forwards calls to mobile we have create account

on Hik-connect app and add indoor station to created account. Details required we can find on screen of

indoor station. SettingsMaintenance

Num: 9 digit serial number

Psw: 6 letters verification code

Password to settings on screen of indoor station is – 123456 or 888999 (depend of version of firmware)

Page 23: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 9a

We can program the delay time of forwarding call.

IntercomTime ParametersCall Forwarding Time (max 20 sec)

Page 24: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 10

PROGRAMMING DOOR STATION EXTENSIONS (Up to 8).

We can program up 8 additional entry points in Hikvision IP intercoms. To make our second door station

additional entry point we need to change ID of our door station from 0 to 1 or 2 etc. And reboot door station.

IntercomID Configuration

Page 25: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 10a

After that our door station change to sub door station and in the Linked Network Configuration we have to

assign (Main) Door Station IP Address.

NetworkLinked Network Configuration

After that we should have 2 (or more) Door Stations calling to the same Indoor Station

Page 26: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 11

PROGRAMMING INDOOR STATION EXTENSIONS (Up to 5).

We can program up to 5 indoor station extensions linked to main indoor station. It’s mean we could have 6

indoor stations calling the same time from door station.

IntercomID Configuration Device Type

Page 27: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

Step 11a

After the reboot Indoor station will change to extension of the main Indoor station.

Last setting will be link our Station Extension with main Indoor Station.

NetworkLinked Network Configuration

After that red icon with Station should change to Green on Indoor station extension. Procedure is the same

for additional Station Extensions. Only changing the number - No: 2

Page 28: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

APPENDIX A

Programming Vandal resistant door station DS-KB8112-IM

Following the steps 1 to 3 on programming Villa door station. This door station working on firmware 1.4.5. This firmware is not fully

compatible with latest indoor station firmware 1.4.71. Problem is the live view request on indoor station – delay approx. 10 to 15

seconds. To avoid delay need to downgrade (or upgrade) to previous version of firmware of indoor station 1.4.70. -That

firmware to fully apply required restore default setting after upgrade the firmware and reboot the indoor station

Page 29: Hikvision Video Intercoms - Mercury Security · Villa Door Stations 12V Powered locally or 24V PoE via Hikvision PoE distributor unit –DS-KAD6XX or 24V PoE switch / injector Latest

APPENDIX A CONTINUED

After that we following configuration for indoor station.

This door station have a build web server which is allow access to programing settings via browser. We can access to

additional features of this door station. For example we can program the relay unlock duration. Villa door station and indoor

station or KD apartment station are not accessible via browser.