installation manual - h2oasis installation, adjustment, alteration, service or maintenance can cause...

20
1 7033-328C May 09, 2017 3100 Millennium Wood Appliance Model(s): 31M-ACC-MBK WARNING If the information in these instruc- tions is not followed exactly, a fire could result causing property damage, personal injury, or death. • Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • Do not over fire - If appliance or chimney connector glows, you are over firing. Over firing will void your warranty. • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire. HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace. Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. WARNING WARNING Fire Risk. For use with solid wood fuel only. Other fuels may over fire and generate poisonous gases (i.e. carbon monoxide). Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL NOTE To obtain a French translation of this manual, please contact your dealer or visit www.quadrafire.com Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.quadrafire.com O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.

Upload: buikien

Post on 08-Mar-2018

223 views

Category:

Documents


0 download

TRANSCRIPT

1 7033-328C May 09, 2017

3100 Millennium Wood Appliance

Model(s):31M-ACC-MBK

WARNING

If the information in these instruc-tions is not followed exactly, a fire could result causing property damage, personal injury, or death.

• Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.

• Donotoverfire-Ifapplianceorchimneyconnectorglows,youareoverfiring.Overfiringwillvoidyourwarranty.

• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.

HOT SURFACES! Glassandothersurfacesarehot duringoperationANDcooldown.

Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISE children in same room as

fireplace.• Alertchildrenandadultstohazardsofhightemperatures• High temperatures may ignite clothing or other

flammable materials.• Keepclothing, furniture,draperiesandotherflammable

materialsaway.

WARNING

WARNINGFire Risk.Forusewithsolidwoodfuelonly.Otherfuelsmayoverfireandgeneratepoisonousgases(i.e.carbonmonoxide).

Installation ManualInstallation & Appliance Set-Up

INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.

NOTICE: DO NOT DISCARD THIS MANUAL

NOTEToobtainaFrenchtranslationofthismanual,pleasecontactyourdealerorvisitwww.quadrafire.com

Pourobtenirunetraductionfrançaisedecemanuel,s’ilvousplaîtcontactervotrerevendeurouvisitezwww.quadrafire.com

O-T LTested and Listed by

PortlandOregon USA

OMNI-Test Laboratories, Inc.C US

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.

2 7033-328C May 09, 2017

3100 Millennium Wood Appliance

1 Important Safety Information ...........3A.ApplianceCertification.............................................3B.BTU&EfficiencySpecifications..............................3C.MobileHomeApproved........................................... 3D.GlassSpecifications................................................3E.Non-CombustibleMaterials......................................3F.CombustibleMaterials..............................................3

2 Getting Started ..................................4A.DesignandInstallationConsiderations....................... 4B.FireSafety................................................................4C.NegativePressure.................................................4D.ToolsAndSuppliesNeeded....................................5E.InspectApplianceandComponents........................5F.RemovalofAppliancefromShippingMaterials.......5G.InstallChecklist........................................................6

3 Dimensions and Clearances ............7A.ApplianceDimensions.............................................7B.HearthProtectionRequirements.............................8C.ClearancestoCombustibles...................................9

4 Chimney Systems ...........................10A.LocatingYourAppliance&Chimney.......................10B.ChimneyTerminationRequirements.......................11C.2-10-3Rule..............................................................11D.ChimneyHeight/RiseandRun.................................12E.VentingComponents................................................12F.ChimneySystems.....................................................12G.InstallingChimneyComponents..............................14H.ProperDraft............................................................14

5 Appliance Set-Up ............................15A.OutsideAirKitInstallation.......................................15B.DoorHandleAssembly............................................16C.Blower(Optional)....................................................16

6 Mobile Home Installation ................177 Reference Materials ........................188 Accessory List ................................19

TABLE OF CONTENTS

Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedmayresultindeathorseriousinjury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,mayresultinminorormoderateinjury.• NOTICE:Indicatespracticeswhichmaycausedamagetotheapplianceortoproperty.

Quadra-FireisaregisteredtrademarkofHearth&HomeTechnologies.

May 09, 2017 7033-328C 3

3100 Millennium Wood Appliance

Model: 3100MillenniumWoodAppliance

Laboratory: OMNITestLaboratories,Inc.Report No: 0061WS066S

Type: ListedRoomAppliance,SolidFuelType

Standard: UL1482-11(R2015)andULCS627-00and(UM)84-HUD,MobileHomeApproved.

TheQuadra-Fire3100SeriesWoodAppliance(ACC)meetstheU.S.EnvironmentalProtectionAgency’scribwoodemis-sionlimitsforwoodappliancessoldafterMay15,2015.

EPACertification#: 649EPACertifiedEmissions: 1.1gramsperhour*LHVTestedEfficiency: 79.9%**HHVTestedEfficiency: 74%

***EPABTUOutput: 11,700to32,000/hr.****PeakBTU/HourOutput: 57,200

VentSize: 6inchesFireboxSize: 2cubicfeet

RecommendedWoodLength: 16inchesFuelOrientation: Front-to-Back

Fuel SeasonedCordWood*Weighted average LHV (Low Heating Value) efficiency usingDouglasFirdimensional lumberanddatacollectedduringEPAemissiontest.LHVassumesthemoistureisalreadyinavaporstatesothereisnolossinenergytovaporize.**WeightedaverageHHV(HighHeatingValue)efficiencyusingDouglasFirdimensional lumberanddatacollectedduringEPAemissiontest.HHVincludestheenergyrequiredtovaporizethewaterinthefuel.***ArangeofBTUoutputsbasedonEPADefaultEfficiencyandtheburnratesfromthelowandhighEPAtests,usingDouglasFirdimensionallumber.****ApeakBTUoutoftheappliancecalculatedusingthemax-imumfirsthourburnratefromtheHighEPATestandtheBTUcontentofcordwood(8600)timestheefficiency.

Improper installation, adjustment, alteration, service ormaintenancecancauseinjuryorpropertydamage.Forassistanceoradditionalinformation,consultaqualifiedinstaller,serviceagencyoryourdealer.Hearth&HomeTechnologiesWILLNOTwarrantyappli-ancesthatexhibitevidenceofover-firing.Evidenceofover-firingincludes,butisnotlimitedto: • Warpedairtube • Deterioratedrefractorybrickretainers • DeterioratedbaffleandotherinteriorcomponentsD. Glass SpecificationsThisapplianceisequippedwith5mmceramicglass.Replaceglassonlywith5mmceramicglass.Pleasecon-tactyourdealerforreplacementglass.

NOTE:Hearth&HomeTechnologies,manufacturerofthisappliance,reservestherighttoalteritsproducts,theirspecificationsand/orpricewithoutnotice.

C. Mobile Home Approved • Thisapplianceisapprovedformobilehomeinstalla-

tions;whennotinstalledinasleepingroomandwhenanoutsidecombustionairinletisprovided.

• Thestructuralintegrityofthemobilehomefloor,ceil-ing,andwallsmustbemaintained.

• Theappliancemustbeproperlygroundedtotheframeofthemobilehomewith#8coppergroundwire.

• OutsideAirKit,partOAK-ACCmustbeinstalledinamobilehomeinstallation.

F. Combustible MaterialsMaterialmadeof/orsurfacedwithanyofthefollowingma-terials: -Wood -CompressedPaper -PlantFibers -Plastic -Plywood/OSB -SheetRock(drywall)

Anymaterialthatcanigniteandburn:flameproofedornot,plasteredornon-plastered.

E. Non-Combustible MaterialsMaterialwhichwillnotigniteandburn,composedofanycombinationofthefollowing:

-Steel -Plaster -Brick -Iron -Concrete -Tile -Glass -Slate

MaterialsreportedaspassingASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C.

1 Important Safety InformationA. Appliance Certification

B. BTU & Efficiency Specifications

NOTE: Thisinstallationmustconformwithlocalcodes.Intheabsenceoflocalcodesyoumustcomplywith (UM) 84-HUD and NFPA211 intheU.S.A.andCAN/CSA-B365 Installation Codes in Canada.

4 7033-328C May 09, 2017

3100 Millennium Wood Appliance

Install Guide2 Getting Started

A. Design and Installation ConsiderationsConsiderationmustbegivento: • Safety • Convenience • Trafficflow • ChimneyandchimneyconnectorrequiredItisagoodideatoplanyourinstallationonpaper,usingexactmeasurements for clearancesand floor protection, beforeactuallybeginningtheinstallation.Ifyouarenotusinganexistingchimney,placetheappliancewheretherewillbeaclearpassageforafactory-builtlistedchimneythroughtheceilingandroof.Werecommendthataqualifiedbuildinginspectorandyourinsurancecompanyrepresentativereviewyourplansbeforeandafterinstallation.

Ifthisapplianceisinanareawherechildrenmaybenearitisrecommendedthatyoupurchaseadecorativebarriertogoinfrontoftheappliance. Remembertoalwayskeepchildrenawaywhile it is operatinganddonot let anyoneoperatethisapplianceunlesstheyarefamiliarwiththeseoperatinginstructions.

WARNING

• DONOTCONNECTTHISAPPLIANCETOACHIM-NEYFLUESERVICINGANOTHERAPPLIANCE.

• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.

Mayallowfluegasestoenterthehouse.

Asphyxiation Risk.

Checkbuildingcodespriortoinstallation.

• InstallationMUST complywith local, regional, state andnationalcodesandregulations.

• Consult insurance carrier, local building, fire officials orauthorities having jurisdiction about restrictions, installationinspection,andpermits.

CAUTION

NOTICE:HEARTH&HOMETECHNOLOGIESASSUMESNORESPONSIBILITYFORTHE IMPROPERPERFORMANCEOFTHEAPPLIANCESYSTEMCAUSEDBY:

• Inadequatedraftduetoenvironmentalconditions

• Downdrafts

• Tightsealingconstructionofthestructure

• Mechanicalexhaustingdevices

• Overdraftingcausedbyexcessivechimneyheights

• Idealperformance iswithheightofchimneybetween14-16feet(4.26-4.88m)measuredfromthebaseoftheappliance.

Toprovide reasonable fire safety, the following should begivenseriousconsideration:1. Install at least one smoke detector on each floor of

your home to ensure your safety. They should belocated away from the heating appliance and closeto the sleeping areas. Follow the smoke detectormanufacturer’splacementandinstallationinstructions,andbesuretomaintainregularly.

C. Negative Pressure

Negativepressure results from the imbalanceofair avail-ablefor theappliancetooperateproperly. Itcanbestron-gestinlowerlevelsofthehouse.

Causesinclude:

• Exhaustfans(kitchen,bath,etc.)• Rangehoods• Combustion air requirements for furnaces, water

appliancesandothercombustionappliances• Clothesdryers• Locationofreturn-airventstofurnaceorairconditioning• ImbalancesoftheHVACairhandlingsystem• Upperlevelairleakssuchas: - Recessedlighting - Attichatch - Ductleaks

WARNING

• Negativepressurecancausespillageofcom-bustionfumes,sootandcarbonmonoxide.

• Applianceneedstodraftproperlyforsafety.

Asphyxiation Risk.

B. Fire Safety

2. A conveniently locatedClassA fire extinguisher tocontendwithsmallfiresresultingfromburningembers.

3. ACOdetectorshouldbeinstalledintheroomwiththeappliance.

4. Apracticedevacuationplan,consistingofatleasttwoescaperoutes.

5. Aplantodealwithachimneyfireasfollows: Intheeventofachimneyfire:

a Evacuatethehouseimmediatelyb. Notifyfiredepartment.

May 09, 2017 7033-328C 5

3100 Millennium Wood Appliance

Figure 5.1

• Installationanduseofanydamagedappliance.• Modificationoftheappliance.• Installation other than as instructed byHearth &Home

Technologies.• Installationand/oruseofanycomponentpartnotapproved

byHearth&HomeTechnologies.• Operatingappliancewithoutfullyassemblingallcomponents.• Operatingappliancewithoutlegsattached(ifsuppliedwith

appliance).• DoNOTOverfire-Ifapplianceorchimneyconnectorglows,

youareoverfiring.Any such action that may cause a fire hazard.

WARNINGFire Risk.Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:

D. Tools And Supplies NeededBeforebeginningtheinstallationbesurethefollowingtoolsandbuildingsuppliesareavailable:

Reciprocatingsaw Framingmaterial

Pliers Hightempcaulkingmaterial

Hammer Gloves

Phillipsscrewdriver Framingsquare

Flatbladescrewdriver Electricdrillandbits

Plumbline Safetyglasses

Level Tapemeasure

Misc.screwsandnails 7/16socketorwrench

1/2-3/4in.length,#6or#8self-drillingscrews

• Removeapplianceandcomponentsfrompackagingandinspectfordamage.

• Reporttoyourdealeranypartsdamagedinshipment.• Read all the instructions before starting the installation.

Follow these instructions carefully during the installation to ensure maximum safety and benefit.

E. Inspection of Appliance and Components

Inspectapplianceandcomponentsfordamage.Damagedpartsmayimpairsafeoperation.

WARNING

• DoNOTinstalldamagedcomponents.• DoNOTinstallincompletecomponents.• DoNOTinstallsubstitutecomponents.

Reportdamagedpartstodealer.

Fire Risk.

Tominimizetheeffectsofnegativeairpressure:• Install optional outside air kit with the intake facing

prevailingwindsduringtheheatingseason• Ensureadequateoutdoorairforallcombustionappliances

andexhaustequipment• Ensurefurnaceandairconditioningreturnventsarenot

locatedintheimmediatevicinityoftheappliance• Avoid installing theappliancenear doors,walkwaysor

smallisolatedspaces• Recessedlightingshouldbea“sealedcan”design• Attichatchesweatherstrippedorsealed• Atticmountedductworkandairhandlerjointsandseams

tapedorsealed• Basementinstallationsshouldbeavoided

1.Removeboxand2x4structuralboardsbeingcarefulnottodamageproduct.

2.Using7/16socketorwrenchremoveoneboltlocatedinsidefrontpartofappliance(Figure 5.1).

3.Movingtothebackoftheapplianceandusing7/16socketorwrenchremovetwobolts(Figure 5.1).

4.Carefullypullapplianceoffofpalletandputindesiredlocation following Hearth Pad and Clearance toCombustiblesonpages8and9.

F. Removal of Appliance from Shipping Materials

2

3

6 7033-328C May 09, 2017

3100 Millennium Wood Appliance

G. Install Checklist

Appliance Install

Appliance is leveled and connector is secured to appliance.Hearth extension size/height decided. Outside air kit installed.Floor protection requirements have been met.If appliance is connected to a masonry chimney, it should be cleaned and inspected by a professional. If installed to a factory built metal chimney, the chimney must be installed according to the manufacturer’s instructions and clearances.

Chimney

Chimney installed, locked and secured in place with proper clearance. Chimney meets recommended height requirements (14-16 feet).

Terminations installed and sealed.

ClearancesCombustible materials not installed in non-combustible areas.

Mantels and wall projections comply with installation manual requirements. Protective hearth strips and hearth extension installed per manual requirements.

Appliance SetupAll packaging and protective materials removed.

All labels have been removed from the door.All packaging materials are removed from inside/under the appliance.Manual bag and all of its contents are removed from inside/under the appliance and given to the party responsible for use and operation.

ATTENTION INSTALLER:Follow this Standard Work Checklist

This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.

Customer: __________________________________________________________________________Date Installed: __________________________________________________________________________Lot/Address: __________________________________________________________________________Location of Appliance: ______________________________________________________________Installer: __________________________________________________________________________Dealer/ Distributor Phone #: ______________________________________________________________Serial #: __________________________________________________________________________Model : __________________________________________________________________________

WARNING! Risk of Fire or Explosion!

Hearth & Home Technologies recommends the following:

• That this checklist remain visible at all times on the appliance until the installation is complete.

Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:Comments communicated to party responsible by on (Builder/Gen. Contractor) (Installer) (Date)

YES IF NO, WHY?

May 09, 2017 7033-328C 7

3100 Millennium Wood Appliance

24-3/8 in [618mm]

26-5/8 in [677mm]

31-3/8 in[796mm]

19-3/4 in [501mm]

Figure 7.1 Front View

Figure 7.3 Side View

25-1/4 in [641mm]

29-1/2 in[749mm]

15-1/8 in [383mm]

21 in [533mm]

11 in[278mm]

Figure 7.2 Top View

3-1/2 in[89mm]

6-11/16 in[170mm]

12-3/4 in [323mm]

3 Dimensions and ClearancesA. Appliance Dimensions NOTE:FlueCollarsizeis6inch(152mm)diameter(ID)

8 7033-328C May 09, 2017

3100 Millennium Wood Appliance

B. Hearth Protection RequirementsEMBER PROTECTION: It isnecessaryto installaTypeIfloorprotector.Floorprotectormustbenon-combustiblematerial,extendingbeneathappliancewithaminimumof16inches(406mm)infrontofglassand8inches(203mm)tobothsidesofthefuelloadingdoor.Openthedoorandmeasure8inches(203mm)fromthesideedgeoftheopeninginthefaceoftheappliance.

In Canada, It is required to install emberprotectionof 18inches(457mm)infrontand8inches(203mm)fromthesidesandrearoftheappliance.Figure 8.2 *See exception.

*EXCEPTION: Non-combustible floor protectionsmustextendbeneaththefluepipewheninstalledwithhorizontalventingandextend2inches(51mm)beyondeachside.See Figure 8.2

WARNINGFire Risk. Hearthpadsmustbeinstalledexactlyasspecified.Hightemperaturesorhotembersmayigniteconcealedcombustibles.

16 in. from glass 8 in.

Fuel loading door

.

31-5/8 in.minimum

39 in.minimum

USA

Figure 8.2Figure 8.1 Figure 8.3

203mm

203mm 203mm

457mm

1243mmminimum

1041mmminimum

Must extend 51mmbeyond each sideof pipe (shaded area)

CANADA

33-1/4 in.

38-15

/16 in

.

3-1/16

in.

135°

optio

nal

cove

rage

52-1/2 in.

31-5/

8 in

60-5/

8 in.

27-3/

8 in.

USA

Corner hearth pad dimensionswithsinglewallpipe

Corner hearth pad dimensionswithdoublewallpipe

27-3/

8 in.

31-3/4 in.

38-15

/16 in

.

3-1/16

in.

135°

optio

nal

cove

rage

51 in.

31-5/

8 in

58-1/

2 in.

USA

Figure 8.4

776m

m

806mm

1243

mm

135°

optio

nal

cove

rage

1562mm

1041

mm

1538

mm

CANADA

851mm

1243

mm

135°

optio

nal

cove

rage

1400mm

1041

mm

1592

mm

776m

m

CANADAFigure 8.5 Figure 8.6

May 09, 2017 7033-328C 9

3100 Millennium Wood Appliance

C. Clearances to CombustiblesMINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters)

Note: A, C, and F Dimensions are to the center of the flue collar 3100 Millennium

INSTALLATION: FULL VERTICAL A B C D E F G H

SINGLE WALL PIPE 18-1/4 (464) 11-3/4 (298) 28-1/2 (724) 16 (406) 8 (203) 20 (508) 48 (1219) 12 (305)

DOUBLE WALL PIPE 13-1/2 (343) 6-1/2 (165) 25 (635) 13 (330) 6-1/2 (165) 18-1/2 (470) 48 (1219) 9 (229)

INSTALLATION: 90 DEGREE ELBOW OFF TOP OF APPLIANCE THROUGH BACKWALL

SINGLE WALL PIPE 15 (381) 8-1/2 (216) 25 (635) 13 (330) 8 (203) 20 (508) 48 (1219) 12 (305)

DOUBLE WALL PIPE 11 (279) 4-1/2 (114) 20-1/2 (521) 8-1/2 (216) 6-1/2 (165) 18-1/2 (470) 48 (1219) 9 (229)

INSTALLATION: ALCOVE

DOUBLE WALL PIPE 14-3/4 (375) 8-1/4 (210) 26-1/2 (673) 14-1/2 (368) N/A N/A 48 (1219) N/A

For alcove only: Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney. Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced

alcove clearances. Canada must comply with CAN/ULC-S269 M87 for the 650° factory built chimney.

NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction

Fire Risk.• Complywithallminimumclearancesto

combustiblesasspecified.• Failuretocomplymaycausehousefire.

WARNINGNOTE: Service Space

Inordertoreplacethetubechannelassemblyaclearanceof19inches(483mm)isrequiredontherightsideofapplianceinordertoremovethetubeswiththeapplianceinplace.Ifspaceisnotavailable,theappliancewillhavetobediscon-nectedfromthechimneytoproceedwiththetubereplace-ment.

BACKWALL / SIDEWALL

A B

C

D

EF

F

E

CORNER INSTALLATION

C

ALCOVE TOP VIEW

G A

ALCOVE SIDE VIEW

G90° OFF TOP UP & OUT CEILING CLEARANCE

H

10 7033-328C May 09, 2017

3100 Millennium Wood Appliance

Recommended Location

Marginal Location

Location Not

Recommended

Recommended

Location

Location NOT

Recommended

Multi-level Roofs

Windward

Leeward Outside Air Kit Termination Cap

Figure 10.1

A. Locating Your Appliance & ChimneyLocation of the appliance and chimney will affect perfor-mance.AsshowninFigure 10.1thechimneyshould: • Installthroughthewarmspaceenclosedbythebuild-

ingenvelope.Thishelpstoproducemoredraft,espe-ciallyduringlightinganddiedownofthefire.

• Penetratethehighestpartoftheroof.Thisminimizestheaffectsofwindturbulenceanddowndrafts.

• Considertheappliancelocationinordertoavoidfloorandceilingatticjoistsandrafters.

• Locate termination cap away from trees, adjacentstructures,unevenrooflinesandotherobstructions.

Yourlocaldealeristheexpertinyourgeographicareaandcanusuallymakesuggestionsordiscoversolutionsthatwilleasilycorrectyourflueproblem.

4 Chimney Systems

May 09, 2017 7033-328C 11

3100 Millennium Wood Appliance

3ft.(91cm)Minimum

Lessthan10ft.(305cm)

2ft.(61cm) 3ft.(91cm)Minimum

10ft.(305cm) ToNearestRoofline2ft.(61cm)

PitchedRoofFigure 11.1

Figure 11.2

10 ft. (305cm) or more

3 ft. (91cm) Minimum

Less than 10 ft. (305cm)

2 ft. (61cm) Minimum

3 ft. (91cm) Minimum

Wall or Parapet

Flat Roof

C. 2-10-3 Rule These are safety requirements and are not meant to

assure proper flue draft.

Thisapplianceismadewitha6inch(152mm)diameterchimney connector as the flue collar on the appli-ance.

• Changingthediameterofthechimneycanaffectdraftandcausepoorperformance.

• It isnot recommended touseoffsetsandelbowsataltitudesabove4000feetabovesealevelandorwhenthereareotherfactorsthataffectfluedraft.

B. Chimney Termination RequirementsFollowmanufacturer’sinstructionsforclearance,securingflashingandterminatingthechimney.Fig. 11.1 & 11.2 • MusthaveanapprovedandListedcap

• Mustnotbelocatedwhereitwillbecomepluggedbysnoworothermaterial

• Mustterminateatleast3feet(91cm)abovetheroofandatleast2feet(61cm)aboveanyportionoftheroofwithin10feet(305cm).

• MustbelocatedawayfromtreesorotherstructuresNOTICE:• Chimneyperformancemayvary.• Trees,buildings,rooflinesandwindconditionsaffect

performance.• Chimneyheightmayneedadjustmentifsmokingor

overdraftoccurs.

NOTICE: Locating the appliance in a basement or in alocationofconsiderableairmovementcancauseintermittentsmokespillagefromappliance.Donotlocateappliancenear• Frequentlyopendoors• Central heat outlets or returns

12 7033-328C May 09, 2017

3100 Millennium Wood Appliance

NOTE: InCanadawhenusingafactory-builtchimneyitmustbesafetylisted, Type UL103 HT (2100oF) CLASS “A” or conformingtoCAN/ULC-S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.

FloorProtector

ChimneyConnector

Insulated " T "

Flashing

Listed Termination Cap

Trim Collar onInside Wall

Listed Chimney

Storm Collar

Wall Support

Roof Brace (if required)

Thimble

Figure 12.1 Prefabricated Exterior Chimney

E. Venting Components Chimney Connector:Itisalsoknownasfluepipeorappliancepipe.Thechimneyconnectorjoinstheappliancetothechimney.Itmustbea6inch(152mm)minimumdiameter24gaugemildsteelblackor26gaugebluedsteel,oranapprovedair-insulateddoublewallventingpipe.Thimble:Amanufactured or site-constructed device installed incombustiblewalls throughwhich the chimney connectorpasses to the chimney. It is intended to keep thewallsfrom igniting. Site constructed thimblesmustmeetNFPA211Standards.PrefabricatedmustbesuitableforusewithselectedchimneyandmeetUL103TypeHTStandards.Followinstructionsprovidedbythemanufacturerformanufacturedthimblesformasonrychimneyandprefabricatedchimneys.

F. Chimney Systems

Prefabricated Metal Chimney• Mustbeminimum6inch(152mm)diameter(ID)high

temperaturechimneylistedtoUL103HT(2100oF)orULCS629M.

• Mustusecomponentsrequiredbythemanufacturerforinstallation.

• Mustmaintainclearancesrequiredbythemanufacturerforinstallation.

• Refertomanufacturersinstructionsforinstallation.

D. Chimney Height / Rise and RunThisproductwasdesignedforandtestedona6inch(152mm)chimney,14to16feet(420-480cm)high,(includesapplianceheight)measuredfromthebaseoftheappliance.Thefurtheryourstackheightordiametervariesfromthisconfiguration,thegreaterthelikelihooditmayaffectperformance.Chimneyheightmayneed tobe increasedby2 -3%pereach1000feetabovesealevel.Itisnotrecommendedtouseoffsetsorelbowsataltitudesabove4000feetabovesealevelorwhenthereareotherfactorsthataffectfluedraft.

WARNINGAsphyxiation Risk.• DONOTCONNECTTHISApplianceTOACHIM-

NEYFLUESERVICINGANOTHERAPPLIANCE.• DONOTCONNECTTOANYAIRDISTRIBUTION

DUCTORSYSTEM.Mayallowfluegasestoenterthehouse.

Improperinstallation,adjustment,alteration,serviceormain-tenancecancauseinjuryorpropertydamage.Refertotheowner’sinformationmanualprovidedwiththisappliance.Forassistanceoradditionalinformationconsultaqualifiedinstaller,serviceagencyoryourdealer.

WARNING

Fire Risk.InspectionofChimney:•Chimneymustbeingoodcondition.•MeetsminimumstandardofNFPA211

• Factory-builtchimneymustbe6inch(152mm)UL103HT.

WARNING

Chimney:Thechimneycanbeneworexisting,masonryorprefabricatedandmustmeetthefollowingminimumrequirementsandasspecifiedinSection4F.

May 09, 2017 7033-328C 13

3100 Millennium Wood Appliance

FloorProtector

ChimneyConnector

Ceiling Support

Listed Chimney

Listed Termination Cap

Storm Collar

Flashing

Figure 13.1 - Prefabricated Interior Chimney

ThimbleSiteconstructedformasonrychimneyinstallation:

Components• A minimum length of 12 inches [305mm] (longer for

thicker walls) of solid insulated factory-built chimneylengthconstructedtoUL103TypeHT6inch(152mm)insidediameter.Chimneyneedstoextendaminimumof2inches(51mm)fromtheinteriorwallandaminimumof1inch(25mm)fromtheexteriorwall.

• Wall spacer, trimcollarandwallband tofit solidpackchimneyselected.

• Minimum8inch(203mm)diameterclaylinersection(ifnotalreadypresentinchimney)andrefractorymortar.

• When jurisdiction requires install approved chimneylinerinmasonrychimney.

Air Clearances•MasonrychimneyclearancemustmeetNFPA211mini-mumrequirementof2inches(51mm)tosheetmetalsup-portsandcombustibles.

•Minimumof1 inch(25mm)clearancearoundthechim-neyconnector.

•Top of wall opening is a minimum of 13-1/2 inches(343mm) from ceiling or 4-1/2 inches (114mm) belowminimum clearance specified by chimney connectormanufacturer.NFPA211minimumverticalclearanceof18inches(457mm)fromchimneyconnectorandceilingorminimumrecommendedbychimneyconnectormanu-facturer.Figure 13.2

Instructions:1. Openinsidewallatproperheightforthechimneycon-

nectortoentrythemasonrychimney. Figure 13.22. Entryholetomasonrychimneymustbelinedwithan8

inch (203mm)minimumdiameter clay liner, orequiva-lent,securedwithrefractorymortar.

3. Constructa17inchx17inch(432mmx432mm)outsidedimensionframefrom2x2framinglumbertofitintowallopening.Insideopeningofframeshouldbenolessthan14inchx14inch(356mmx356mm).Figure 13.2

4. Attachthewallspacertothechimneysideoftheframe.5. Nailtheframeintothewallopening.Thespacershould

beonthechimneyside.6. Insertthesectionofthesolidinsulatedchimneyintothe

outerwallofthemasonrychimney.7. Tightlysecurethelengthofthesolidinsulatedchimney

withthewallbandtothemasonrychimney.8. Insertasectionofchimneyconnectorintothechimney.

Makesureitdoesnotprotrudepasttheedgeoftheclaychimneylinerinsidethechimney.

9. Sealtheendofthechimneyconnectortotheclaylinerwithrefractorymortar.

10. Installtrimcollararoundthesoldpackchimneysection.

Figure 13.2

1.5”

1.0”

2.0”

2.0”1.5”

14.0” ID17.0” OD

ceiling

Minimum18.0” NFPA 211

13.5” below ceiling to top of opening

1.0”8.0”

1.5 2x2 framing stud2.0 min air clearance1.0 min air clearance4.5

or top of opening is a min.of 4.5” below min.clearance specified by connector mfg.

Center of HoleThimble

CL

CL

Wall

Include depth of hearth pad

14 7033-328C May 09, 2017

3100 Millennium Wood Appliance

Trim Collar

Chimney Section with 2 inch

(51mm) Clearance to Combustibles

Chimney Connector

Fire Clay Flue Liner

with Airspace

Masonry Chimney

Wall Band to Secure Chimney

Section

Wood Studs Used for Framing - Spaced

2 inch (51mm) clearance from

Masonry Chimney

Wall Spacer

Solid Pack Chimney with Metal Supports as a Thimble

Figure 14.1

Fire Risk.DoNOTpackinsulationorothercombustiblesbetweenspacers.• ALWAYSmaintainspecifiedclearancesaroundvent-ingandspacers.

• Installspacersasspecified.Failuretokeepinsulationorothermaterialawayfromventpipemaycausefire.

WARNING

Flue GasDirection

CrimpedEnd

TowardAppliance

Secure pipe sections with aminimum of 3 screws

Figure 14.3 Chimney Connector (Appliance Pipe)

WARNING

ONLYuseconnector:• Withintheroom,betweenapplianceandceilingorwall.ConnectorshallNOTpassthrough:• Atticorroofspace• Closetorsimilarconcealedspace• Floororceiling

Maintainminimumclearancestocombustibles

Fire Risk.FollowChimneyConnectorManufacturer’sInstructionsforProperInstallation.

Chimney FlueLiner

FireclayLiner or

Equivalent

Masonry ChimneyConstructed to NFPA 211

Wall SpacerWall Band

Trim Collar

Chimney Connector

1 inch (25mm) AirSpace to Chimney

Section

Min. Clearance2 inch (51mm)

Min. Chimney Clearance toWall Spacer and

Combustibles - 2 inch (51mm)

Chimney Section

Figure 14.2

Solid Pack Chimney with Metal Supports as a Thimble (Cont’d)

G. Installing Chimney Components

Chimney Connector

Singlewallconnectororappliancepipe.Thismustbeatleast24gaugemildsteelor26gaugebluesteel.Thesectionsmustbeattachedtotheapplianceandtoeachotherwith thecrimped(male)endpointingtowardtheappliance.Alljoints,includingtheconnectionatthefluecollar,shouldbesecuredwith3sheetmetalscrews.Makesure to follow theminimum clearances to combustibles.Wherepassagethroughthewall,orpartitionofcombustibleconstructionisdesiredinCanada,theinstallationshallcon-formtoCAN/CSA-B365.Factory-builtlistedchimneyconnector(vented).A listed connector (vented)must be usedwhen installingthisapplianceinamobilehome.Thelistedconnectorsmustconformtoeachothertoensureaproperfitandseal.

H. Proper Draft

TobesurethatyourQuadra-Fireinsertburnsproperly,thechimneydraft(staticpressure)shouldbeapproximately-0.10incheswater column (W.C.) during a high burn and -0.04inchesW.C.duringalowburn,measured6inches(152mm)abovethetopoftheinsertafteronehourofoperationateachburnsetting.

May 09, 2017 7033-328C 15

3100 Millennium Wood Appliance

Figure 15.1 - Floor & Rear Installation

Flex Line Wire Tie

Wire Tie Flex Adapter

Termination Cap

For Floor Installa-tions Remove Circular “Knock-Out” in Base of Pedestal.

Figure 15.2

CoverPlate

Rope to SealPedestal

Items Needed for Installation (not supplied) • 4inchflexaluminumpipe,orifusingalternatematerial,

thenitshallbemadefromdurable,non-combustible,heatresistantmaterialupto350oF.Cutthepipetotherequiredlengthforyourinstallation.

•Phillipsheadscrewdriver •Siliconesealant •Drillsandsawsnecessaryforcuttingholesthroughthe

wallorflooringinyourhome.1. Removeallmaterialsfrompackingbox.2. Usinga#2Phillipsscrewdriverattachtheflexadapterto

theapplianceusing4screws.Figure 15.1 3. For floor installations, remove circular” knock-out” in the

baseofthepedestal.4. Floor & Rear Installation:Cuta4inch(102mm)holein

outsidewallorfloortoaccommodateoutsideairpiping.Use4inch(102mm)aluminummetalflexorrigidpipingtodirectlyconnectoutsideairtoapplianceintake.Usethesuppliedterminationcapwitharodentscreen.Sealbetweenthewall(orfloor)andthepipewithsiliconetopreventmoisturepenetration.

5. Floor Installation Alternative: InsomeinstancesyoumaynotbeabletoinstalltheflexpipeasshowinFigure

A. Outside Air Kit Installation Asourceofair (oxygen) isnecessary inorder forcombus-tion to take place. Whatever combustion air is consumedbythefiremustbereplaced.Airisreplacedviaairleakagearoundwindowsandunderdoors.Inhomesthathavetightlysealeddoorsandwindows,anoutsideairsourceisneeded.AnoptionalOutsideAirKitisavailable. WARNING

Fire Risk.Asphyxiation Risk.Donotdrawoutsidecombustionairfrom:

• Wall,floororceilingcavity

• Enclosedspacesuchasanatticorgarage

• Closeproximitytoexhaustventsorchimneys

Fumesorodormayresult

Asphyxiation Risk.Outsideairinletmustbelocatedtopreventblockagefrom:

• Leaves

• Snoworice

• Otherdebris

Blockmaycausecombustionairstarvation

Smokespillagemaysetoffalarmsorirritatesensitiveindividuals.

WARNING

Asphyxiation Risk.LengthofoutsideairsupplyductshallNOTexceedthelengthoftheverticalheightoftheexhaustflue.• Firewillnotburnproperly• Smokespillageoccurswhendoorisopeneddue

toairstarvation.

WARNING

Included in OAK-ACC: Termination cap, (2) wire ties, flexadapter,andfasteners

Included in SRV7033-041:Cover plate and sealing rope (seeFloor InstallationAlternativebelow,Figure 15.2)

15.1.Ifthatisthecase,youwillneedtoorderSRV7033-041which includesacoverplateandsealing ropeasshowninFigure 15.2.Thegoalistosealthepedestalsonoroomaircanleakintothepedestalorforcoldairinfiltration.

5 Appliance Set-Up

16 7033-328C May 09, 2017

3100 Millennium Wood Appliance

B. Door Handle Assembly

Figure 16.1

Install spring handle using a counter-clockwisemotion until thespringhandlehasa2inchclearancefrombendofdoorhandrod(Figure 16.1).

Tools Required:#2Phillipsheadscrewdriver1.Locateboltssuppliedwiththeblower.2.Alignholesinmountingflangeofblowerwithboltholesin

appliance.BlowershouldbepositionedatbottomofrearouterskinasshowninFigure 16.2

3.Re-insert and tighten bolts, securing blower onto outerwallofappliance.

Shock Risk.• DoNOTremovegroundingprongfromplug.• Routecordawayfromappliance.• DoNOTroutecordunderorinfrontofappliance.

• Plugdirectlyintoproperlygrounded3prongreceptacle.

CAUTION

Figure 16.2

MANUAL: Over-rides the Snap Disc

AUTO: Fan will turn ON/OFF Automatically by the Snap Disc

Controls the Fan Speed

Snap Disc Bracket with Magnet

MANUAL

FAN

AUTO

LOW

HIGH OFF

Secure wires with wire tie

Secure blower with 3 bolts

4.Place the bracket containing the snap disc and magnetunderthebottomleftrearcorner.

SeeOwner’s Manualfordetailedoperatinginstructionsfortheblowerandsnapdisc.

C. Blower (Optional)

Door Handle

Spring Handle

2 inch (51mm) clearance required from bend in door handle rod to end of spring handle.

May 09, 2017 7033-328C 17

3100 Millennium Wood Appliance

CAUTIONTHESTRUCTURALINTEGRITYOFTHEMOBILEHOMEFLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINEDDoNOTcutthrough:• Floorjoist,wall,studsorceilingtrusses.• Anysupportingmaterialthatwouldaffectthestructuralinteg-

rity.

NEVERINSTALLINASLEEPINGROOM.Consumesoxygenintheroom.

WARNINGAsphyxiation Risk.

1. AnoutsideairinletmustbeprovidedforcombustionSeepage 15forinstallationinformation.

2. Appliancemustbesecuredtothemobilehomestructurebyboltingthepedestalthroughhearthpadandintofloor.

3. Appliancemust be grounded with #8 solid coppergroundingwireorequivalentandterminatedateachendwithN.E.C.approvedgroundingdevice.

4. AppliancemustbeinstalledwithanapprovedUL103HTventilated chimney connector,UL103HTchimney, andterminalcapwithsparkarrestor.Neveruseasinglewallconnector(appliancepipe)inamobilehomeinstallation.Use only double-wall connector pipe,Dura-VentDVL,Selkirk Metalbestos DS or Security DL double-wallconnectororanylisteddouble-wallconnectorpipe.

5. InCanada,thisappliancemustbeconnectedtoa6 inch(152mm) factory-built chimney conforming toCAN/ULC-629M,STANDARDFORFACTORYBUILTCHIMNEYS.

6. Followthechimneyandchimneyconnectormanufacturer’sinstructionswhen installing thefluesystemforuse inamobilehome.

7. Maintainclearancetocombustibles.8. Floorprotectionrequirementsmustbefollowedprecisely.9. Use silicone to create aneffective vapor barrier at the

locationwherethechimneyorothercomponentpenetratestotheexteriorofthestructure.

NOTE: Offsets from the vertical, not exceeding 45°, areallowedperSection905(a)oftheUniformMechanicalCode(UMC).Offsetsgreaterthan45°areconsideredhorizontalandarealsoallowed,providingthehorizontalrundoesnotexceed75%oftheverticalheightofthevent.Construction,clearanceandterminationmustbeincompliancewiththeUMCTable9C.ThisinstallationmustalsocomplywithNFPA211.NOTE:Topsectionsofchimneymustberemovabletoallowmaximumclearanceof13.5feet(411cm)fromgroundlevelfortransportationpurposes.

10. Burnwoodonly. Other types of fuelsmaygeneratepoisonousgases(e.g.,carbonmonoxide).

11. Ifapplianceburnspoorlywhileanexhaustblowerisoninhome,(i.e.,rangehood),increasecombustionair.

12. InstallationshallbeinaccordancewiththeManufacturersHome&SafetyStandard(HUD)CFR3280,Part24.

You must use a Quadra-Fire Outside Air Kit Part OAK-ACC and (depending on floor installation), Part SRV7033-041 for installation in a mobile home.

6 Mobile Home Installation

18 7033-328C May 09, 2017

3100 Millennium Wood Appliance

7 Reference MaterialsDate of Service Performed By Description of Service

May 09, 2017 7033-328C 19

3100 Millennium Wood Appliance

Service PartsR

31M-ACCBeginning Manufacturing Date: July 2006

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.

Stocked at Depot

ITEM DESCRIPTION COMMENTS PART NUMBERBlower, Convection - Replacement Blower 812-4900 YHinge Pins, 1/2”, Gold

Pre SN 0071959142832-0250

Hinge Pins, 1/2”, Nickel SRV430-5320Hinge Pins, 1/2”, Black Post SN 0071959142 7000-606/2

Logo, Quadra-FireGold 200-3180Nickel 200-3240

Spring Handle, 1/2”, GoldPre SN 0071959142

832-0620 YSpring Handle, 1/2”, Nickel 250-8330 YSpring Handle, 1/2”, Black Post SN 0071959142 SRV7000-613 YSpring Handle, 1/4”, Gold

Pre SN 0071959142832-0630 Y

Spring Handle, 1/4”, Nickel 250-8340 YSpring Handle, 1/4”, Black Post SN 0071959142 SRV7000-614 YComponent Pack (Includes Touch-Up Paint, Spring Handles (1) 1/2” and (2) 1/4”, Trimount Plug, Owners Manual and Warranty Card).

Black & Gold Trim 7033-027

Nickel Trim 7033-029Paint Touch-Up 812-0910Plug, Trimount, .250” Pkg of 24 229-0880/24 Y

Door Handle Assembly 832-0540 YUpgrade, Door, Nickel UK-DRNLGasket, Manifold Pkg of 4 7038-168/4 Y

ACCESSORIESBlower Assembly BK-ACC

Blower Control Box w/Switch SRV7000-194 YComponent Pack 7033-051Snap Disc Bracket Assembly SRV7033-036Snap Disc, # 1, Convection Blower SRV230-0470 YWire Harness, Blower 7033-262

Outside Air Kit, Floor & Rear OAK-ACCOutside Air Collar Assembly 7033-039Outside Air Shield 33271 YOutside Air Cover Plate Assembly SRV7033-041 Y

FASTENERSAvk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools RIVNUT-REPAIR YBolt, Hex Head, 1/4-20 x 1 Pkg of 10 25221A/10 YButton Head 1/4-20 x .5 Pkg of 20 32328/20 YNut, Keps Lock, 10-32 Pkg of 40 226-0050/40 YNut, Keps Lock, 8-32 Pkg of 40 226-0060/40 YNut, Ser Flange Small 1/4-20 Pkg of 24 226-0130/24 YScrew, Sheet Metal #8 x 1/2 S-Grip Pkg of 40 12460/40 YWasher, 1/4 Sae Pkg of 24 28758/24 Y

Service PartsR

31M-ACCBeginning Manufacturing Date: July 2006

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.

Stocked at Depot

ITEM DESCRIPTION COMMENTS PART NUMBERBlower, Convection - Replacement Blower 812-4900 YHinge Pins, 1/2”, Gold

Pre SN 0071959142832-0250

Hinge Pins, 1/2”, Nickel SRV430-5320Hinge Pins, 1/2”, Black Post SN 0071959142 7000-606/2

Logo, Quadra-FireGold 200-3180Nickel 200-3240

Spring Handle, 1/2”, GoldPre SN 0071959142

832-0620 YSpring Handle, 1/2”, Nickel 250-8330 YSpring Handle, 1/2”, Black Post SN 0071959142 SRV7000-613 YSpring Handle, 1/4”, Gold

Pre SN 0071959142832-0630 Y

Spring Handle, 1/4”, Nickel 250-8340 YSpring Handle, 1/4”, Black Post SN 0071959142 SRV7000-614 YComponent Pack (Includes Touch-Up Paint, Spring Handles (1) 1/2” and (2) 1/4”, Trimount Plug, Owners Manual and Warranty Card).

Black & Gold Trim 7033-027

Nickel Trim 7033-029Paint Touch-Up 812-0910Plug, Trimount, .250” Pkg of 24 229-0880/24 Y

Door Handle Assembly 832-0540 YUpgrade, Door, Nickel UK-DRNLGasket, Manifold Pkg of 4 7038-168/4 Y

ACCESSORIESBlower Assembly BK-ACC

Blower Control Box w/Switch SRV7000-194 YComponent Pack 7033-051Snap Disc Bracket Assembly SRV7033-036Snap Disc, # 1, Convection Blower SRV230-0470 YWire Harness, Blower 7033-262

Outside Air Kit, Floor & Rear OAK-ACCOutside Air Collar Assembly 7033-039Outside Air Shield 33271 YOutside Air Cover Plate Assembly SRV7033-041 Y

FASTENERSAvk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools RIVNUT-REPAIR YBolt, Hex Head, 1/4-20 x 1 Pkg of 10 25221A/10 YButton Head 1/4-20 x .5 Pkg of 20 32328/20 YNut, Keps Lock, 10-32 Pkg of 40 226-0050/40 YNut, Keps Lock, 8-32 Pkg of 40 226-0060/40 YNut, Ser Flange Small 1/4-20 Pkg of 24 226-0130/24 YScrew, Sheet Metal #8 x 1/2 S-Grip Pkg of 40 12460/40 YWasher, 1/4 Sae Pkg of 24 28758/24 Y

8 Accessory List

20 7033-328C May 09, 2017

CONTACT INFORMATION

Hearth & Home Technologies352 Mountain House Road

Halifax, PA 17032Division of HNI INDUSTRIES

Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer

log onto www.quadrafire.com

DO NOT DISCARD THIS MANUALCAUTION

• Important operating and maintenance instruc-tions included.

• Leave this manual with party responsible for use and operation.

• Read, understand and follow these instruc-tions for safe installa-tion and operation.

DO NOTDISCARD

We recommend that you record the following pertinent information for your heating appliance.

Date purchased/installed:_________________________________________________________________________

Serial Number:____________________________________ Location on appliance:___________________________

Dealership purchased from:________________________________________ Dealer phone:_1(_____)_____-______

Notes:________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962 or other U.S. and foreign patents pending.