intra aortic balloon pump zahra arab.m . sc .student of critical care nursing

38
20/2/89 z.Arab.M.Sc

Upload: halen

Post on 21-Mar-2016

64 views

Category:

Documents


5 download

DESCRIPTION

INTRA AORTIC BALLOON PUMP Zahra Arab.M . Sc .student of critical care nursing. اهداف یادگیری. ⋆ آشنایی با بالن پمپ داخل آئورت و نحوه کار آن ⋆ شناخت موارد استفاده، منع استفاده و عوارض بالن پمپ ⋆ شرح مداخلات پرستاری درارتباط با استفاده وتنظیمات ان ⋆ معیارهای جداسازی از بالن پمپ. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89z.Arab.M.Sc

Page 2: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

INTRA AORTIC BALLOON PUMP

Zahra Arab.M.Sc .student of critical care nursing

z.Arab.M.Sc 20/2/89

Page 3: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89

آن ⋆ کار نحوه و آئورت داخل پمپ بالن با آشنایی

⋆ پمپ بالن عوارض و استفاده منع استفاده، موارد شناخت

⋆ ان وتنظیمات استفاده با درارتباط پرستاری مداخالت شرح

⋆ پمپ بالن از جداسازی معیارهای

z.Arab.M.Sc

Page 4: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

z.Arab.M.Sc

کمکی وسیله یک آئورت داخل پمپ بالنو خون گردش بهبود برای که است

رود می بکار قلب کردن پمپ .عمل

سال در بار شخصی 1967اولین توسطشد گرفته بکار کانتروویتز نام .به

گردش تامین در چپ بطن که وقتی

شود ناتوان رسانی خون و کافی خونروش با همراه تواند می وسیله ایندچار میوکارد از حمایت برای طبیگردد استفاده آسیب یا .ایسکمی

20/2/89

Page 5: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

The System 97e is a helium charged, mobile, Intra-Aortic Balloon Pump (IABP).

20/2/89z.Arab.M.Sc

Page 6: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89

Intra-aortic balloon catheter

z.Arab.M.Sc

Page 7: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89z.Arab.M.Sc

Page 8: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Insertion Techniques There are alternative routes for balloon insertion. In patients with extremely severe peripheral

vascular disease or in pediatric patients the ascending aorta or the aortic arch may be entered for balloon insertion.

Other routes of access include subclavian axillary iliac arteries

20/2/89z.Arab.M.Sc

Page 9: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89

It is inserted into the descending aorta via the femoral artery either percutaneously or by surgical cut-down.

It should be positioned so that the tip is approximately 1 to 2 cm below the origin of the left subclavian artery and above the renal arteries. On chest x-ray the tip should be visible in the 2nd or 3rd intercostal space

z.Arab.M.Sc

Page 10: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

IABP-correct placement

20/2/89z.Arab.M.Sc

Page 11: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

TimingTwo primary methods:

Conventional timingReal timing

z.Arab.M.Sc 20/2/89

Page 12: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Isovolumetric contractionSystole{ Ejection

Isovolumic relaxation

Diastole{ Ventricular filling

z.Arab.M.Sc 20/2/89

Page 13: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

z.Arab.M.Sc

Arterial waveform

Arterial waveform With IABP

20/2/89

Page 14: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89

It inflates immediately following aortic valve closure to augment diastolic coronary perfusion pressure.

Inflation

z.Arab.M.Sc

Page 15: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Inflation of IABP Causes⇧Aortic diastolic pressure

⇧Aortic root pressure

⇧Coronary perfusion pressure

⇧Oxygen supply

20/2/89z.Arab.M.Sc

Page 16: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89

Deflation The balloon rapidly

deflates just before ventricular systole to reduce Left Ventricular work

Deflation creates a "potential space" in the aorta, reducing aortic volume and pressure

z.Arab.M.Sc

Page 17: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Deflation of the IABP Causes⇩Aortic end-diastolic pressure

⇩ Impedance to ejection

⇩ Afterload

⇩ Oxygen demand

⇧ Cardiac output

20/2/89z.Arab.M.Sc

Page 18: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

اگر بالون زودتر از موعد خود متسع شود ☻(قبل از بسته شدن دریچه آئورت ) مقدار .افترلود بیشتروکار قلب افزایش می یابد

z.Arab.M.Sc 20/2/89

Page 19: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

تقویت ☻ میزان شود متسع موعد از دیرتر بالون اگرحاصل بوده نظر مد که آئورت دیاستولی شود فشار نمی

شده، بینی پیش مقدار از کمتر کرونر به خونرسانی وشود می .انجام

z.Arab.M.Sc 20/2/89

Page 20: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

☻ ( در یعنی شود تخلیه خود موقع از زودتر بالون اگر ) دیاستولی فشار تقویت شود تخلیه دیاستول طول

نظر مورد مقدار از کمتر کرونر به خونرسانی و آئورتشود می .انجام

z.Arab.M.Sc 20/2/89

Page 21: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

مقدار ☻ نیز شود تخلیه معمول از دیرتر بالون اگریابد می افزایش قلب وکار .افترلود

z.Arab.M.Sc 20/2/89

Page 22: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

z.Arab.M.Sc

متون بر مرور

تاثير 1379 درمعصومی هدف با ای مطالعه درپمپ بالون

از پس قلبي پايين بازده با بيماران در آئورتي داخلكه کرد گيري نتيجه چنين باز قلب جراحي اعمال

زمان در بموقع گيري تصميم موفقيت اصلي عاملصحيح وتنظیم بالون نمودن خارج و گذاشتن

. استفاده كه شد مشخص آن از گذشته بود دستگاهدستگاه ) تناوب دو به يك حالت با پمپ بالون از

) يك به يك حالت از موثرتر قلب ضربان به نسبت . بيماران در كه شد معلوم همچنين باشد مي

الزم باال دوز با آدرنالين از استفاده چنانچه كرونريبه نياز و ميوكارد وخيم وضعيت دهنده نشان باشد،

است پمپ بالون از 20/2/89.استفاده

Page 23: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Indications1. Refractory ventricular failure2. Cardiogenic shock3. Unstable refractory angina4. Impending (To threaten to happen) infarction5. Mechanical complications due to acute myocardial infarction6. Ischemia related intractable (Difficult to manage) ventricular arrhythmias

20/2/89z.Arab.M.Sc

Page 24: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

7. Cardiac support for high-risk general surgical and coronary angiography/ angioplasty patients

8. Septic shock

9. Weaning from cardiopulmonary bypass

10. Support for failed angioplasty and valvuloplasty

20/2/89z.Arab.M.Sc

Page 25: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Contraindications1.Severe aortic valve insufficiency

2. Abdominal or aortic aneurysm

3. Severe calcific aorta-iliac disease or peripheral vascular disease

4. Scarring of the groin20/2/89z.Arab.M.Sc

Page 26: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Potential Side Effects and Complications

Bleeding at the insertion site Thrombocytopenia Immobility of the balloon catheter Balloon leak Infection Aortic dissection during insertion

20/2/89z.Arab.M.Sc

Page 27: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Peripheral emboli

Balloon rupture with gas embolus

Renal failure (balloon occlusion of renal artery)

Vascular insufficiency of catheterized limb

20/2/89z.Arab.M.Sc

Page 28: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

متون بر مرور

z.Arab.M.Sc

هاشم سال بنی در ای 1384وهمکاران درمطالعهبيماراني در مرگ عامل ترين مهم كه گرفتند نتيجهو بوده قلبي نارسايي نشدند جدا پمپ بالون از كه

چپ بطن از خون خروجي كسر ميزان كه بيمارانياز را 30كمتر بدتري آگهي پيش اند داشته درصد

شدند . جدا پمپ بالون از كه بيماراني در بودند داراتنفسي و قلبي نارسايي كليه، نارسايي ترتيب به

است بوده ها آن ومير مرگ كننده تعيين .عامل

20/2/89

Page 29: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

قبل ♣ نبض محل گذاری وعالمت انتهایی اندام های ن¡بض کنترل. خلفی نی درشت و پایی پشت ن¡بض بخصوص گذاری کاتتر از

انعقادی ♣ ازمونهای کنترل و کواگوالن انتی وریدی ان¡فوزیوندستور .طبق

از ♣ انتهایی اندامهای پوست وب¡ررسی محیطی های نبض کنترل نظر

درد وجود و رنگ و .گرمی♣ هر پاشنه قسمت از پاها دادن جهت 2تا1ورزش ساعت

وریدی استاز از .جلوگیری♣. است شده وارد کاتتر که پای¡ی کردن خم از .جلوگیری

z.Arab.M.Sc

پمپ بالون دارای بیمار از پرستاری مراقبتهای

20/2/89

Page 30: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

موضعی .♣ عفونت وجود نظر از بیمار کنترلوسیستمیک.

در .♣ حداقل آن حفظ و شریانی متوسط فشار کنترل حدود

60 ادراری 70تا ده برون کنترل و جیوه متر میلی .♣. مثبت اینوتروپ داروهای کاهش دادن قرار نظر .مد

پوزیشن، ) .♣ تغییر سرفه، آتلکتازی از پیشگیریشریانی( خون گازهای وکنترل .ساکشن

z.Arab.M.Sc 20/2/89

Page 31: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

♣.. بستر زخم از پیشگیری

صحت .♣ نظر از دستگاه مختلف قسمتهای کنترل.عملکرد

شکم، .♣ درد وجود نظر از بیمار مداوم کنترلبیضه،پرینه ،

پنه دیس قلب، طپش سینه، .قفسهده .♣ برون ریوی، مویرگهای وج فشار کنترل

ریوی قلبی،الکترو شریان کاردیوگرام،فشار 

z.Arab.M.Sc 20/2/89

Page 32: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Indications for weaningHemodynamic stability

Cardiac index>2L/min/m²Pulmonary artery wedge pressure<20mmHgSystolic blood pressure>100mmHg

Minimal requirements for vasopressor supportEvidence of adequate cardiac function

Good peripheral pulsesAdequate urine output

Evidence of good coronary perfusion

z.Arab.M.Sc 20/2/89

Page 33: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

جداسازی نحوه

1. . ضربانات نسبت کاهش مداوم نسبتی جداسازیابتدا قلب، ضربانات کل تعداد به سپس 1:1حمایتی و

پایان 1:3وبعد 1:2 کاتتر 1:4ودر وخروجبالون .2 تقویتی حجم تدریجی کاهش

3. باال روش دو از ترکیبی

z.Arab.M.Sc 20/2/89

Page 34: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

ConclusionsThe consistent application of intra-aortic balloon pump support of patients with coronary artery disease and its complications has provided a therapeutic platform for direct surgical intervention on otherwise unstable patients with cardiac ischemia, heart failure, and shock.

This integrated approach to the treatment of patients with coronary artery disease has profoundly affected how this disease process is managed throughout the world.

20/2/89z.Arab.M.Sc

Page 35: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89z.Arab.M.Sc

Arterial insufficiency is the most common complication of IABP therapy.

Patient requiring IABP are managed much like any other critically ill patient.

Page 36: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

: منابع1. . - یو، سQی ای یو، سی سی ویژه مراقبتهای پرسQتاری احمد نوقابی اسدی

. سالمی. نشر 157-150ص1387دیالیز2. . . . كاربرد نتايج رسول كيش فراست ميترا محمدي گل ناديا هاشم بني

علوم . دانشگاه مجله قلب جرQاحي بيماران در آئورت داخل Qپمپ بالون . QمارهQش دوازدهم دوره ایران سال. 48پزشQکی Qالعاده 60-55ص1384فوق

3. . بازده با بيماران در آئورتي داخل پمپ بالون تاثير علي معصوم معصومي . Qپزشكي علوم دانشگاه باز قلب Qجراحي اعمال از Qپس قلبي پايين

تابستان . بهبود 7-1((:6پیاپی ) 1)4; 1379كرمانشاه . 4.Morton.P, Fontaine.D. Critical Care Nursing:A holistic

Approch.9th edition;Wolters Kluwer,lippincott Wilkins;2008. pp:365-374

5.Black.J, Hawks.J. Medical Sergical Nursing.7th edition;Elsevier; 2005.pp:6.Weigand DL, editor: AACN procedure manual for critical

care, ed 6, Philadelphia, 2010, Saunders.

20/2/89z.Arab.M.Sc

Page 37: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

20/2/89

Thank you

z.Arab.M.Sc

Page 38: INTRA AORTIC BALLOON PUMP Zahra  Arab.M . Sc .student of critical care nursing

Cycle leading to cardiogenic shock

z.Arab.M.Sc 20/2/89