1660SM#01 Part: 2 02 Office Data Manual (ODM) 1830 PSS-32#01 Part: 2 01 1660SM#02 Part: 2 03 1660SM#03 Part: 2 04 1660SM#04 Part: 2 05 1660SM#08 Part: 2 09 1660SM#09 Part: 2 10 1660SM#06 Part: 2 07 1660SM#07 Part: 2 08 NAC: FR93 Project: PO#14 - Domietta Ring Part: 2 06 Site name: Kaf Elbatiekh Customer Name: Telecom Egypt 1660SM#05

Upload: joao-gilberto-fernandes

Post on 10-Jul-2016

67 views

Category:

Documents


10 download

DESCRIPTION

1660 1830

TRANSCRIPT

Page 1: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

1660SM#01Part: 2 02

Office Data Manual (ODM)

1830 PSS-32#01Part: 2 01

1660SM#02Part: 2 03

1660SM#03Part: 2 04

1660SM#04Part: 2 05

1660SM#08Part: 2 09

1660SM#09Part: 2 10

1660SM#06Part: 2 07

1660SM#07Part: 2 08

NAC: FR93

Project: PO#14 - Domietta Ring

Part: 2 06

Site name: Kaf Elbatiekh

Customer Name: Telecom Egypt

1660SM#05

NAC: FR93

Page 2: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

1830 PSS-32 # 01

Initial Document

Office Data Manual (ODM)

Kaf Elbatiekh

0

Telecom Egypt

SITE ADRESS:

SITE NAME:

0Customer No:

Customer Name:

SAP Network ID:

Page 3: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Equipment Number : 01

Version 1.0Document PurposeFinal Document Verification Date N/ADocument EngineerDocument Helpdesk Telephone Number Technical Support Helpdesk Telephone NumberTechnical Support Helpdesk Mail AddressSAP Network IDAllView Number

For Installation instructions see : See Floor LayoutInstallation Guide Version NameInstallation Guide Release Issue

Date

Work Description

Alcatel-Lucent Document Control

Document Author

Initial Document

Bartosz Górny

N/A

Telecom EgyptPO#14 - Domietta Ring

Kaf Elbatiekh

Alcatel-Lucent Document Number

Egypt

1830 PSS-32

BASE: DASH:

8DG61259AAAAJZZA

6.0

Installation of 1830PSS-32#01 shelf in new rack.

Document Author

Name

Signed

Checked by Approved by

Name Name

Signed Signed

Post Installation As Built Verification

Alcatel-Lucent Representative Customer Representative

Name Name

Date Date

Signed Signed

Kaf Elbatiekh

Document Information Sheet 1830 PSS-32 # 01

Part 2 01 page 1 of 30 Version 1.0

Bartosz Górny

16-06-2015

Telecom Egypt

Part 2 01 page 1 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights ReservedRx.x_Vx A4

16-06-2015

Page 4: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

DOCUMENT CHANGE HISTORY

Version Status Reason for Change / Re Issue Engineer Date

1.0 I Installation of 1830PSS-32#01 shelf in new rack. Bartosz Górny 16-06-2015

I - Initial ODM # - NewF - Final ODM * - Removed

& - Transferred (moved)% - Changed

Kaf Elbatiekh 0 Telecom Egypt

Survey of Changes 1830 PSS-32 # 01

Part 2 01 page 2 of 30 Version 1.0 16-06-2015 Part 2 01 page 2 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 5: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Part Number Description Page

2 1 1

2 1 2

2 1 3

2 1 4

2 1 5

2 1 6

2 1 7

2 1 8

2 1 9

2 1 10

2 1 11

2 1 12

2 1 13

2 1 14

2 1 15

2 1 16

2 1 1744-channel static filter DWDM connections

44-channel static filter DWDM connections

44-channel static filter DWDM connections

Tributary cards internal connections

Optical amplifiers LINE connections 1830PSS-32#01 to TE ODF

Optical amplifiers cross conn.

Front View 1830 PSS-32#01

SFP Modules for shelf 1830PSS-32#01

Optical amplifiers DCM connections

Site Materials Specification

Front View Rack Layout

SFP Modules for shelf 1830PSS-32#01

XFP Modules for shelf 1830PSS-32#01

Material Specification Hardware

Document Information Sheet

Survey of Changes

Index

2 1 17

2 1 18

2 1 19

2 1 20

2 1 21

2 1 22

2 1 23

2 1 24

2 1 25

2 1 26

2 1 27

2 1 28

2 1 29

2 1 30

Kaf Elbatiekh 0 Telecom Egypt

Index 1830 PSS-32 # 01

Part 2 01 page 3 of 30 Version 1.0

Appendix B - ODF layout

Appendix C1 - HK and Rack alarm

Cable List Grounding

Appendix A - Floor Plan layout

11DPM12 client signals to ODF

Cable List Power Supply

11G client signals 1830 PSS-32 do ODF

11DPM12 client signals to ODF

Inventory connections

Internal Connections

44-channel static filter DWDM connections

44-channel static filter DWDM connections

44-channel static filter DWDM connections

44-channel static filter DWDM connections

16-06-2015Part 2 01 page 3 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 6: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

H

Check off

8DG59604AC** KIT-CO SHELF INSTALLATION ETSI

8DG60129AA** CO SHELF ETSI COVER KIT

1AB017500078 BREAKER, 63A

8DG59605AB** MAIN SHELF KIT-PSS32, HIGH CAPACITY FAN

8DG59242BB** DC POWER FILTER (50A) W/ V MONITORING

8DG60207AAAA ESWL-1830 PSS WAVELENGTH TRACKER SOFTWARE LICENSE FEE

8DG62322AAAA SWP 1830PSS R6.0.6 4/16G EC DVD NO GMPLS

8DG62440AAAA SWPL 1830PSS R6.0.6 4/16G EC NO GMPLS

8DG59241AD** EQUIPMENT CONTROLLER (16GB)

8DG60227AAAA ACI-1830PSS DIR.SHIP.STANDARD

3AL89583AAAA CA-CRAFT CABLE (3M), (ETSI) ,HAL-FREE

8DG62440AAAA SWPL 1830PSS R6.0.6 4/16G EC NO GMPLS

8DG59418AA** FULL SLOT BLANK

8DG59613AA** KIT-TOOL KIT

8DG59724AA** FOADM INVENTORY CABLE ADAPTER

8DG09121AA** ETSI ONE RACK WITHOUT TRU/DOOR

1AF17443AAAA 1830 PDU-ETSI

8DG60224AAAA OPTIONAL PDU SLIDER KIT FOR ETSI

1AC043850003 CABLE 2 PAIR SHIELDED - ETSI

1AD151930001 FIBER STORAGE TRAY (2U)

8DG60131AC** DCM COVER KIT (ETSI)

8DG59417AB** KIT-DCM SHELF (ANSI/ETSI)

8DG59603AA** KIT-OMD INSTALLATION KIT

8DG60130AC** OMD COVER KIT (ETSI)

3AL75117AAAA ESWL-PHOTONICS VERS "A" WDM LP

8DG59248AA** 44 CHANNEL OPTICAL MUX/DEMUX

3AL75117AAAA ESWL-PHOTONICS VERS "A" WDM LP

8DG60349AA** 11G QUAD PORT PLUGGABLE ANYRATE (4 CLIENT)

3AL75118AAAA ESWL-PHOTONICS VERS "A" TDM LP

8DG59828AA** 11G DPORT PLUGGABLE MULTIRATE MUX (12UC)

1AB215120078 SIMPLEX JUMPER (3.5M) - ETSI

1AB375650046 ALU XFP DWDM TUNABLE CT

1AB215120075 SHORT JUMPER (230MM) - VOA APPLICATION

1AB215120076 SHORT JUMPER (155MM) - VOA APPLICATION

1AB396080001 FAST EVOA SFP

12

12

6

80

2

40

2

12

6

1

1

2

2

12

2

2

1

1

1

1

1

2

1

1

1

16

1

1

1

2

1

2

1

1

1

Ordercode Comcode Description Qty

1AB396080001 FAST EVOA SFP

1AB375380013 ALU XFP I-64.1/10GBE BASE-L

1AB373110001 OE-TRX SFP CWDM PIN CH51 B_SFP*MULTIRATE STM-1/16

1AB376720002 ALU SFP GBE LX/LX10 -40/+85

1AB215120078 SIMPLEX JUMPER (3.5M) - ETSI

3AL75117AAAA ESWL-PHOTONICS VERS "A" WDM LP

8DG59945AA** HIGH POWER LOW GAIN DWDM AMPLIFIER

1AB215120056 DUPLEX JUMPER (3.5M) - ETSI (SM FOR INTERNAL CONNECTIONS)

8DG59423AA** DCM - SMF 10KM

Kaf Elbatiekh 0 Telecom Egypt

Material Specification Hardware 1830 PSS-32 # 01

Part 2 01 page 4 of 30 Version 1.0

Note : The Installer shall use this sheet to check that all materials have been delivered

16-06-2015

8

2

6

4

2

16

8

40

4

Part 2 01 page 4 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 7: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

ICheck off

Rack accessoriesINSULATING TAPE 19.1MM X 4.572MR BLACK VELCRO

Power cables 25mm2 /1660SM/CABLE POWER PVC BLACK 2X25MM2

HEAT SHRINKABLE TUBE 2:1 12.7MM RED

HEAT SHRINKABLE TUBE 2:1 12.7MM CLEAR

HEAT SHRINKABLE TUBE 2:1 12.7MM BLUE

HEAT SHRINKABLE TUBE 2:1 12.7MM BLACK

GND cable 25mm2 /1660SM/CABLE POWER LS0H GREEN/YELLOW 25MM2

LUG: TUBULAR TULIP B8-S16-22

GND cable 16mm2 /internal grounding; 1662SMC/CABLE POWER LS0H GREEN/YELLOW 16MM2

Inventory cableCABLE: SF/UTP, TE3 2x2x0.4MM SOLID HH2/M, GREY LS0H 4.65x3MM

Alarm cables 1830PSS-32CABLE: SF/UTP SYMMETRICAL PAIR (4QUAD, 2PAIRR/QUAD), 4x(2+2)x0.5MM SOLID, GREY PVC 0.8MM, 120OHM (1MHZ)

HK cables 1830PSS-32/VDS 1662SMCDF CORD 16P HF HE5-25MC 25 M

TB for E1, HK, VDS, alarm TRU2 X1/2 COVER-ACCESSORY FOR COMPAX+ LABEL

MOUNTING STRIP, 89713

ODFSET OF 2 SC/PC OPTICAL ADAPTOR

Fibers for internal connections 1830PSS32to PSS-32 or PSS-36/64OPTO CABLE ASSEMBLY SX 2.0 SM LC/PC-LC/PC 1.5M LSZH-Y INDOOR

OPTO CABLE ASSEMBLY SX 2.0 SM LC/PC-LC/PC 2.5M LSZH-Y INDOOR

Fibers to internal or LINE ODFOPTO CABLE ASSEMBLY SX 2.0 SM LC/PC-FC/PC 10M LSZH-Y INDOOR

OPTO CABLE ASSEMBLY SX 2.0 SM SC/PC-LC/PC 10M Y INDOOR

Protection pipeCABLE PIPING ROUND TUBE 17MMCables for IP phoneCABLE ASSEMBLY CAT6E S/FTP 4x2x0.4 LSZH WHITE RJ-45-RJ-45 2M

Installation kitSET SCREW - INSTALLATION OF STATION /S9

1

1

6

4

44

40

4

4

22

6

8

25

1

8

11

3

16

1

1

1

1

Ordercode Comcode Description Qty

1300507449

1AC029050004

1AC000570022

1AC000570029

1AC000570039

1AC000570009

1AC053180011

1AB032050044

1AC053180008

1AC020430001

1AC013280001

3AL17957HLAA

1AD021330001

1AC014270015

3CT01050AAAA

1AB347840002

1AB347840003

1AB350260005

1AB346850008

1AC044110001

1AB229830003

1AD041540001 SET SCREW - INSTALLATION OF STATION /S9

ODF 36FO +rackOPTICAL PATCHING MODULE 1U - 36 ADAPTORS

STORAGE OPTICAL MODULE 1U - 36 PATCHCORDS OR JUMPERS , LEFT OR RIGHT OPENING, 10080280

CABINET 600X2200X300MM [WxHxD] 21IN 47U WITHOUT DOOR

OPTO CABLE ASSEMBLY SX 2.0 SM SC/UPC-FC/UPC 10 MR G657A2 LSZH-Y INDOOR

IP PHONE3GV27064UB Alcatel-Lucent IP Touch 4008 phone extended edition Urban Grey

CABLE POWER LS0H GREY FG7(0)M1 2X2.5MM2PMV2-6RB-C Metric ring terminal with vinyl insulationFSF80-12-7 Insullated ferules - single wire French end sleeve

Vinyl Butt splice - blue

Vinyl Butt splice - redFixed Shelf/tray for ETSI rack deep /<250mm +fixing accessories (screw, cage nuts, washers)/

1AB017500057 BREAKER, 1A

Kaf Elbatiekh 0 Telecom Egypt

Site Materials Specification 1830 PSS-32 # 01

Part 2 01 page 5 of 30 Version 1.0

1

1

1

1

Note : The Installer shall use this sheet to check that all materials have been delivered

16-06-2015

1

3

2

2

2

1

4

1

2

1AD041540001

1AD082730006

1AD082730004

1AD029930001

1AB423400001

Part 2 01 page 5 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 8: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Row Bay

01 PDU

02 1830PSS-32#01 (L1, L2)

L1: slot 2-3, dir. New DomiettaL2: slot 4-5, dir. Domietta1

03 SFD44 #01 L1: dir. New Domietta

04 SFD44 #02 L2: dir. Domietta1

05 Fiber Storage Tray

06 DCM shelfL1: slot 1 dir. New Domietta

Front View Rack Layout

... WDM

DMSMF010 (1)DMSMF010 (2)

L1: slot 1 dir. New DomiettaL2: slot 2 dir. Domietta1

07 IP PHONEL3: dir. Banha

ETSI ONE RACK 2200x600x300 [HxWxD]

Kaf Elbatiekh 0 Telecom Egypt

Front View Rack Layout 1830 PSS-32 # 01

Part 2 01 page 6 of 30 Version 1.0 16-06-2015

IP PHONE

Part 2 01 page 6 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 9: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Row Bay

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

0 2 2 2 2 1 1 2

7 Full Slot Blank Full Slot Blank 8DG59418AA**

8 Full Slot Blank Full Slot Blank 8DG59418AA**

5 AHPLG HIGH POWER LOW GAIN DWDM AMPLIFIER 8DG59945AA

6 Full Slot Blank Full Slot Blank 8DG59418AA**

3 AHPLG HIGH POWER LOW GAIN DWDM AMPLIFIER 8DG59945AA

4 AHPLG HIGH POWER LOW GAIN DWDM AMPLIFIER 8DG59945AA

Part no. (Comcode)1 EC Equipment Controller (16GB) 8DG59241ADAA

2 AHPLG HIGH POWER LOW GAIN DWDM AMPLIFIER 8DG59945AA

Bla

nk

Bla

nk

Bla

nk

Bla

nk

PF

DC

(50

A)

POS. Short Description Card DescriptionB

lank

Bla

nk

Bla

nk

Bla

nk

Bla

nk

Bla

nk

11Q

PA

4

11Q

PA

4

Ful

l Slo

t Bla

nk

Ful

l Slo

t Bla

nk

11D

PM

12

11D

PM

12

EC

PF

DC

(50

A)

Bla

nk

Bla

nk

Bla

nk

Bla

nk

Ha

lf S

lot

Bla

nk

Hal

f Slo

t Bla

nk

Ful

l Slo

t Bla

nk

Ful

l Slo

t Bla

nk

FAN32H

EC

AH

PLG

AH

PLG

AH

PLG

AH

PLG

Ful

l Slo

t Bla

nk

Ful

l Slo

t Bla

nk

Ful

l Slo

t Bla

nk

Ful

l Slo

t Bla

nk

Front View 1830 PSS-32#01

... WDM

USRPNL

2 2 1 1 1 1 2 2 #N/A #N/A 0 0 #N/A #N/A #N/A #N/A 1 1 #N/A

#N/A#N/A#N/A#N/A#N/A#N/A#N/A#N/A#N/A

00

#N/A#N/A

0

Kaf Elbatiekh 0 Telecom Egypt

Front View 1830 PSS-32#01 1830 PSS-32 # 01

Part 2 01 page 7 of 30 Version 1.0 16-06-2015

39 Blank #N/A #N/A

40 USRPNL SSY-USER PANEL 8DG59240AAAA

37 FAN32H High Output PSS-32 Fan Tray 8DG59243ABAA

38 Blank #N/A #N/A

35 Blank #N/A #N/A

36 PFDC (50A) SSY-POWER FILTER, 50A BREAKER 8DG59242BBAA

33 Blank #N/A #N/A

34 Blank #N/A #N/A

31 Blank #N/A #N/A

32 Blank #N/A #N/A

29 Blank #N/A #N/A

30 Blank #N/A #N/A

27 Blank #N/A #N/A

28 Blank #N/A #N/A

25 Half Slot Blank Half Slot Blank 8DG59419AA**

26 Blank #N/A #N/A

23 Blank #N/A #N/A

24 Half Slot Blank Half Slot Blank 8DG59419AA**

21 Blank #N/A #N/A

22 Blank #N/A #N/A

19 PFDC (50A) SSY-POWER FILTER, 50A BREAKER 8DG59242BBAA

20 Blank #N/A #N/A

17 11QPA4 11G QUAD PORT PLUGGABLE ANYRATE (4 CLIENT) 8DG60349AA**

18 EC Equipment Controller (16GB) 8DG59241ADAA

15 11DPM12 11G Dual Port Pluggable Multirate Mux (12 universal clients) 8DG59828AA

16 11QPA4 11G QUAD PORT PLUGGABLE ANYRATE (4 CLIENT) 8DG60349AA**

13 Full Slot Blank Full Slot Blank 8DG59418AA**

14 11DPM12 11G Dual Port Pluggable Multirate Mux (12 universal clients) 8DG59828AA

11 Full Slot Blank Full Slot Blank 8DG59418AA**

12 Full Slot Blank Full Slot Blank 8DG59418AA**

9 Full Slot Blank Full Slot Blank 8DG59418AA**

10 Full Slot Blank Full Slot Blank 8DG59418AA**

8 Full Slot Blank Full Slot Blank 8DG59418AA**

Part 2 01 page 7 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 10: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

02 17

02 17

02 17 VA3

02 17 VA2

02 17 VA1

02 16 VA3

02 16 VA2

02 16 VA1

02 15 VA3

02 15 VA2

02 15 VA1

02 14 VA3

02 14 VA2

02 14 VA1

02 13 VA3

02 13 VA2

02 13 VA1

02 12 VA3

02 12 VA2

02 12 VA1

02 17 VA2 EVOA SFP eVOA SFP 1AB396080001

02 17 VA1 EVOA SFP eVOA SFP 1AB396080001

02 16 VA2 EVOA SFP eVOA SFP 1AB396080001

02 16 VA1 EVOA SFP eVOA SFP 1AB396080001

02 15 VA1 EVOA SFP eVOA SFP 1AB396080001

02 14 VA1 EVOA SFP eVOA SFP 1AB396080001

02 4 OSCSFP SS-16.2O OC3/STM1 PIN SFP (1510nm) with DDM 1AB373110001

02 2 OSCSFP SS-16.2O OC3/STM1 PIN SFP (1510nm) with DDM 1AB373110001

SFP Modules for shelf 1830PSS-32#01

Shelf SlotSFP POS.

SFP Short Desc.

SFP Description Part no. (Comcode)

Kaf Elbatiekh 0 Telecom Egypt

SFP Modules for shelf 1830PSS-32#01 1830 PSS-32 # 01

Part 2 01 page 8 of 30 Version 1.0 16-06-2015Part 2 01 page 8 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 11: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

02

02

02

02

02

02

02

02

9 C8

10 C1

9 C6

9 C7

9 C4

9 C5

9 C2

9 C3

02 9 C1

02 8 C8

02 8 C7

02 8 C6

02 8 C5

02 8 C4

02 8 C3

02 8 C2

02 8 C1

02 15 C8 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 15 C7 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 15 C6 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 15 C5 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 15 C4 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 15 C3 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 15 C2 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 15 C1 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C8 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C7 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C6 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C5 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C4 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C3 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C2 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

02 14 C1 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002

SFP Modules for shelf 1830PSS-32#01

Shelf SlotSFP POS.

SFP Short Desc.

SFP Description Part no. (Comcode)

Kaf Elbatiekh 0 Telecom Egypt

SFP Modules for shelf 1830PSS-32#01 1830 PSS-32 # 01

Part 2 01 page 9 of 30 Version 1.0

02

02

02

02

02

02

02

02

02

02

02

02

02

02

02

02

10 C8

11 C1

10 C6

10 C7

16-06-2015

11 C8

11 C6

11 C7

11 C4

11 C5

11 C2

11 C3

10 C4

10 C5

10 C2

10 C3

10 C1

Part 2 01 page 9 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 12: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

02

02 17 C2

17 C3

02 17 C1

02 16 C3

02 16 C2

02 16 C1

02 15 C3

02 15 C2

02 15 C1

02 14 C3

02 14 C2

02 14 C1

02 13 C3

02 13 C2

02 17 C2 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013

02 17 C1 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013

02 16 C2 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013

02 16 C1 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013

02 16 L2 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046

02 16 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046

02 15 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046

02 14 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046

XFP Modules for shelf 1830PSS-32#01

Shelf SlotXFP POS.

XFP Short Desc.

XFP Description Part no. (Comcode)

02 17 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046

02 17 L2 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046

Kaf Elbatiekh 0 Telecom Egypt

XFP Modules for shelf 1830PSS-32#01 1830 PSS-32 # 01

Part 2 01 page 10 of 30 Version 1.0 16-06-2015Part 2 01 page 10 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 13: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

TE ODF … … … TE ODF_.../.../.../Domietta1/Front/...< >TE LINE ODF_n.a./TE ODF/…/…/…

… … … TE ODF_.../.../.../Domietta1/Front/...< >TE LINE ODF_n.a./TE ODF/…/…/…

Front ... 15 TE LINE ODF n.a.

Front ... 15 TE LINE ODF n.a. TE ODF

… … … TE ODF_.../.../.../New Domietta/Front/...< >TE LINE ODF_n.a./TE ODF/…/…/…

TE ODF ... ... ... Domietta1

… … TE ODF_.../.../.../New Domietta/Front/...< >TE LINE ODF_n.a./TE ODF/…/…/…

Front ... 15 TE LINE ODF n.a. TE ODF

... 15 TE LINE ODF n.a. TE ODF …TE ODF ... ... ... New Domietta

Front

Shelf Tray Side Conn. LabelDirection Side Conn. Length [m] Name Row

...

Optical amplifiers LINE connections TE ODF to TE LINE ODF

The following connections are to be made using cable type: Optical jumper FCsSCs0DB15M/28

From: TE ODF

...

... ...

1830 PS

S-32 # 01

To: TE LINE ODF

02

Op

tical amp

lifiers LIN

E co

nn

ection

s 1830PS

S-32#01 to

TE

OD

F

Kaf E

lbatiekh

From:

0

TE ODF

Name Row Bay Shelf

pag

e 11 o

f 30

1830PSS-32#01_.../WDM/02/Domietta1/4/LINE IN< >TE ODF_.../.../.../.../...

1830PSS-32#01_.../WDM/02/Domietta1/4/LINE OUT< >TE ODF_.../.../.../.../...

10Domietta1

4

...4 LINE OUT 10 TE ODF ...1830PSS-32#01 ... WDM

LINE IN

... ...

... ...

... ...

... ...

1830PSS-32#01_.../WDM/02/New Domietta/2/LINE OUT< >TE ODF_.../.../.../.../...

... ... ... 1830PSS-32#01_.../WDM/02/New Domietta/2/LINE IN< >TE ODF_.../.../.../.../...

TE ODF ...

2 LINE IN 10 TE ODF ...

2 LINE OUT 10

Conn. Label

...1830PSS-32#01 ... WDM 02 New Domietta

Length [m] Name Row Bay Shelf Side

1830PSS-32#01 To: TE ODF

Name Row Bay Shelf Direction Slot Port

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

Optical amplifiers LINE connections 1830PSS-32#01 to TE ODF

The following connections are to be made using cable type: OPTO CABLE ASSEMBLY SX 2.0 SM LC/PC-FC/PC 10M LSZH-Y INDOOR

Part

1.016-06-2015

Attention: Use the same label for both fibre ends

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n

Page 14: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

pag

e 12 o

f 30

1830 PS

S-32 # 01

n.a.OMD OUT 1830PSS-32#01_.../WDM/02/AHPLG/5/LINE IN< >1830PSS-32#01_.../WDM/04/SFD44#02/n.a./OMD OUT

0

LINE OUT 3,5 OMD IN 1830PSS-32#01_.../WDM/02/AM2318A/11/LINE OUT< >1830PSS-32#01_.../WDM/04/SFD44#02/n.a./OMD IN

LINE IN 3,51830PSS-32#01 ... WDM/04 SFD44#021830PSS-32#01 ... WDM 02 AHPLG 5

WDM/02 AHPLG 5SIG OUT 1830PSS-32#01_.../WDM/02/AHPLG/4/SIG IN< >1830PSS-32#01_.../WDM/02/AHPLG/5/SIG OUT

SIG IN 1830PSS-32#01_.../WDM/02/AHPLG/4/SIG OUT< >1830PSS-32#01_.../WDM/02/AHPLG/5/SIG INAHPLG 4

SIG IN 3,51830PSS-32#01 ...

SIG OUT 3,5

LINE OUT 3,5 OMD IN 1830PSS-32#01_.../WDM/02/AHPLG/3/LINE OUT< >1830PSS-32#01_.../WDM/03/SFD44#01/n.a./OMD IN

1830PSS-32#01 ... WDM 02

WDM/03 SFD44#01 n.a.OMD OUT 1830PSS-32#01_.../WDM/02/AHPLG/3/LINE IN< >1830PSS-32#01_.../WDM/03/SFD44#01/n.a./OMD OUT

AHPLG 3LINE IN 3,5

1830PSS-32#01 ...

AHPLG 3SIG OUT 1830PSS-32#01_.../WDM/02/AHPLG/2/SIG IN< >1830PSS-32#01_.../WDM/02/AHPLG/3/SIG OUT

SIG OUT 3,5 SIG IN 1830PSS-32#01_.../WDM/02/AHPLG//SIG OUT< >1830PSS-32#01_.../WDM/02/AHPLG/3/SIG IN2

SIG IN 3,51830PSS-32#01 ... WDM/021830PSS-32#01 ... WDM 02 AHPLG

1830PSS-32#01 ... WDM 02

Bay/Shelf Card Slot Port LabelCard Slot Port Length [m] Name Row

Op

tical amp

lifiers cross co

nn

.

Kaf E

lbatiekh

From: 1830PSS-32#01 To: 1830PSS-32#01

Name Row Bay Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

Optical amplifiers cross conn.

The following connections are to be made using cable type: DUPLEX JUMPER (3.5M), JARRETIERE OPTIQUE SM LC/LC 2.5M/20

Part

Attention: Use the same label for both fibre ends

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n1.0

16-06-2015

Page 15: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

pag

e 13 o

f 30

1830 PS

S-32 # 01

5OUT 1830PSS-32#01_.../WDM/02/AHPLG/5/DCM IN< >AHPLG_.../WDM/02/5/OUT

0

DCM OUT 0,155 DCM IN 1830PSS-32#01_.../WDM/02/AHPLG/5/DCM OUT< >AHPLG_.../WDM/02/5/DCM IN

DCM IN 3,5AHPLG ... WDM 021830PSS-32#01 ... WDM 02 AHPLG 5

WDM 06 2OUT 1830PSS-32#01_.../WDM/02/AHPLG/4/DCM IN< >DMSMF010_.../WDM/06/2/OUT

IN 1830PSS-32#01_.../WDM/02/AHPLG/4/DCM OUT< >DMSMF010_.../WDM/06/2/INAHPLG 4

DCM IN 3,5DMSMF010 ...

DCM OUT 3,5

DCM OUT 0,155 DCM IN 1830PSS-32#01_.../WDM/02/AHPLG/3/DCM OUT< >AHPLG_.../WDM/02/3/DCM IN

1830PSS-32#01 ... WDM 02

WDM 02 3OUT 1830PSS-32#01_.../WDM/02/AHPLG/3/DCM IN< >AHPLG_.../WDM/02/3/OUT

AHPLG 3DCM IN 3,5

AHPLG ...

06 1OUT 1830PSS-32#01_.../WDM/02/AHPLG/2/DCM IN< >DMSMF010_.../WDM/06/1/OUT

DCM OUT 3,5 IN 1830PSS-32#01_.../WDM/02/AHPLG/2/DCM OUT< >DMSMF010_.../WDM/06/1/IN2

DCM IN 3,5DMSMF010 ... WDM1830PSS-32#01 ... WDM 02 AHPLG

1830PSS-32#01 ... WDM 02

Bay Shelf Slot Conn. LabelCard Slot Port Length [m] Name Row

Op

tical amp

lifiers DC

M co

nn

ection

s

Kaf E

lbatiekh

From: 1830PSS-32#01 To: OA, DCM

Name Row Bay Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

Optical amplifiers DCM connections

The following connections are to be made using cable type: SHORT JUMPER (155MM), SIMPLEX JUMPER (3.5M)

Part

Attention: Use the same label for both fibre ends

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n1.0

16-06-2015

Page 16: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

11QPA4 16 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/16/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/16/VA2 INL2 OUT 0,23 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 16

02 11QPA4 16 VA1 IN 1830 PSS-32#01/.../WDM/02/11QPA4/16/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/16/VA1 IN16 L1 OUT 0,155 1830 PSS-32#01 ... WDM

11QPA4 15 VA3 IN 1830 PSS-32#01/.../WDM/02/11QPA4/15/L3 OUT< >1830 PSS-32#01/.../WDM/11QPA4/15/VA3 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L3 OUT 0,23 1830 PSS-32#01 ... WDM 02

11QPA4 15 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/15/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/15/VA2 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L2 OUT 0,23 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 15

02 11QPA4 15 VA1 IN 1830 PSS-32#01/.../WDM/02/11QPA4/15/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/15/VA1 IN15 L1 OUT 0,155 1830 PSS-32#01 ... WDM

11QPA4 14 VA3 IN 1830 PSS-32#01/.../WDM/02/11QPA4/14/L3 OUT< >1830 PSS-32#01/.../WDM/11QPA4/14/VA3 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L3 OUT 0,23 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 14

02 11QPA4 14 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/14/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/14/VA2 IN14 L2 OUT 0,23 1830 PSS-32#01 ... WDM

11QPA4 14 VA1 IN 1830 PSS-32#01/.../WDM/02/11QPA4/14/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/14/VA1 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L1 OUT 0,155 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 14

02 11QPA4 13 VA3 IN 1830 PSS-32#01/.../WDM/02/11QPA4/13/L3 OUT< >1830 PSS-32#01/.../WDM/11QPA4/13/VA3 IN13 L3 OUT 0,23 1830 PSS-32#01 ... WDM

11QPA4 13 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/13/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/13/VA2 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L2 OUT 0,23 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 13

02 11QPA4 13 VA1 IN 1830 PSS-32#01/.../WDM/02/11QPA4/13/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/13/VA1 IN13 L1 OUT 0,155 1830 PSS-32#01 ... WDM

11QPA4 12 VA3 IN 1830 PSS-32#01/.../WDM/02/11QPA4/12/L3 OUT< >1830 PSS-32#01/.../WDM/11QPA4/12/VA3 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L3 OUT 0,23 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 12

02 11QPA4 12 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/12/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/12/VA2 IN12 L2 OUT 0,23 1830 PSS-32#01 ... WDM

11QPA4 12 VA1 IN 1830 PSS-32#01/.../WDM/02/11QPA4/12/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/12/VA1 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L1 OUT 0,155 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 12

1830 PS

S-32 # 01

15

1830 PSS-32#01/.../WDM/02/11QPA4/17/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/17/VA2 IN

0

pag

e 14 o

f 30

1830 PSS-32#01 ... WDM 02 17

1830 PSS-32#01/.../WDM/02/11QPA4/17/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/17/VA1 IN

1830 PSS-32#01 ... WDM 02 11QPA4 17 VA2 INL2 OUT 0,230

... WDM 02 11QPA40,155 1830 PSS-32#01

11QPA4

17 VA1 IN1830 PSS-32#01 ... WDM 02 11QPA4 17 L1 OUT

WDM 02 11QPA4 16 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/16/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/16/VA2 IN11QPA4 16 L2 OUT 0,230 1830 PSS-32#01 ...

11QPA4 16 VA1 IN 1830 PSS-32#01/.../WDM/02/11QPA4/16/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/16/VA1 IN

1830 PSS-32#01 ... WDM 02

L1 OUT 0,155 1830 PSS-32#01 ... WDM 02

15 VA1 IN 1830 PSS-32#01/.../WDM/02/11DPM12/15/L1 OUT< >1830 PSS-32#01/.../WDM/11DPM12/15/VA1 IN

1830 PSS-32#01 ... WDM 02 11QPA4 16

0,155 1830 PSS-32#01 ... WDM 02 11DPM12

VA1 IN 1830 PSS-32#01/.../WDM/02/11DPM12/14/L1 OUT< >1830 PSS-32#01/.../WDM/11DPM12/14/VA1 IN

1830 PSS-32#01 ... WDM 02 11DPM12 15 L1 OUT

1830 PSS-32#01 ... WDM 02 11DPM12 141830 PSS-32#01 ... WDM 02 11DPM12 14 L1 OUT 0,155

Bay Shelf Name Slot Port LabelCard Slot Port Lenght [m] Name Row

Trib

utary card

s intern

al con

nectio

ns

Kaf E

lbatiekh

From: 1830 PSS-32#01 To: 11QPA4, 11DPM12

Name Row Bay Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

Tributary cards internal connections

Cable type: SHORT JUMPER (155MM), SHORT JUMPER (230MM)

Part

11QPA4 17 VA3 IN 1830 PSS-32#01/.../WDM/02/11QPA4/17/L3 OUT< >1830 PSS-32#01/.../WDM/11QPA4/17/VA3 INL3 OUT 0,23 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 17

02 11QPA4 17 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/17/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/17/VA2 IN17 L2 OUT 0,23 1830 PSS-32#01 ... WDM

11QPA4 17 VA1 IN 1830 PSS-32#01/.../WDM/02/11QPA4/17/L1 OUT< >1830 PSS-32#01/.../WDM/11QPA4/17/VA1 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L1 OUT 0,155 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 17

02 11QPA4 16 VA3 IN 1830 PSS-32#01/.../WDM/02/11QPA4/16/L3 OUT< >1830 PSS-32#01/.../WDM/11QPA4/16/VA3 IN16 L3 OUT 0,23 1830 PSS-32#01 ... WDM

11QPA4 16 VA2 IN 1830 PSS-32#01/.../WDM/02/11QPA4/16/L2 OUT< >1830 PSS-32#01/.../WDM/11QPA4/16/VA2 IN

1830 PSS-32#01 ... WDM 02 11QPA4

L2 OUT 0,23 1830 PSS-32#01 ... WDM 021830 PSS-32#01 ... WDM 02 11QPA4 16

Uwaga: użyj jednakowych etykiet na obu końcach kabla

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n1.0

16-06-2015

Page 17: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

EMPTY TX skip

OUT RX skip

RX skip

1830 PS

S-32 # 01

9260IN

EMPTY TX skip

OUT9250

IN

TX skip

OUT RX skipEMPTY

EMPTY TX skip

RX skip

15 of 30

9230IN

OUT

9240IN

EMPTY TX skip

RX skip

pag

e 9220IN

OUT

skip

OUT RX skip9210

INEMPTY

TX

EMPTY TX skip

0

OUT RX skip9200

IN

skip

OUT RX skip9190

INEMPTY

TX

EMPTY TX skip

OUT RX skip9180

IN

TX skip

OUT RX skip

IN

SlotLength [m] Name Row Bay

Port

EMPTY

Bay Port Label

SFD44#01 ... WDM 03

9170

Shelf

44-chan

nel static filter D

WD

M co

nn

ection

s

Kaf E

lbatiekh

From: SFD44#01 To:

Name Row

Part

Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

44-channel static filter DWDM connections

The following connections are to be made using cable type:

Attention: Use the same label for both fibre ends

02 17VA1 OUT SFD44#01_.../WDM/03/9350/IN< >11QPA4_.../WDM/02/17/VA1 OUT

OUT 3.5 L1 IN SFD44#01_.../WDM/03/9350/OUT< >11QPA4_.../WDM/02/17/L1 IN9350

IN 3.511QPA4 ... WDM

SFD44#01_.../WDM/03/9340/IN< >SFD44#02_.../WDM/04/9340/OUT

OUT 3.5 IN SFD44#01_.../WDM/03/9340/OUT< >SFD44#02_.../WDM/04//IN9340

IN 3.5SFD44#02 ... WDM 04 9340

OUT

EMPTY TX skip

16-06-2015

OUT RX skip9330

IN

TX skip

OUT RX skip

INEMPTY

EMPTY TX skip

RX skip

1.0

9310IN

OUT

9320

SFD44#01_.../WDM/03/9300/IN< >SFD44#02_.../WDM/04/9300/OUT

OUT 3,5 IN SFD44#01_.../WDM/03/9300/OUT< >SFD44#02_.../WDM/04/9300/IN9300

IN 3,5SFD44#02 ... WDM 04 9300

OUT

04 9290OUT SFD44#01_.../WDM/03/9290/IN< >SFD44#02_.../WDM/04/9290/OUT

Versio

n

OUT 3,5 IN SFD44#01_.../WDM/03/9290/OUT< >SFD44#02_.../WDM/04/9290/IN9290

IN 3,5SFD44#02 ... WDM

EMPTY TX skip

OUT RX skip9280

IN

EMPTY TX skip

OUT RX skip9270

IN

OUT RX skip

1830 PS

S-32 # 01

Teleco

m E

gyp

t

Page 18: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

04 9450OUT SFD44#01_.../WDM/03/9450/IN< >SFD44#02_.../WDM/04/9450/OUT

OUT 2,5 IN SFD44#01_.../WDM/03/9450/OUT< >SFD44#02_.../WDM/04//IN

IN SFD44#01_.../WDM/03/9440/OUT< >SFD44#02_.../WDM/04/9440/IN

1830 PS

S-32 # 01

9450IN 2,5

SFD44#02 ... WDM

04 9440OUT SFD44#01_.../WDM/03/9440/IN< >SFD44#02_.../WDM/04/9440/OUT

OUT 3,59440

IN 3,5SFD44#02 ... WDM

VA1_OUT SFD44#01_.../WDM/03/9430/IN< >11DPM12_.../WDM/02/15/VA1_OUT

OUT 3,5 L1_IN SFD44#01_.../WDM/03/9430/OUT< >11DPM12_.../WDM/02/15/L1_IN

3,511DPM12 ... WDM 02 15

WDM 02 17VA2_OUT SFD44#01_.../WDM/03/9420/IN< >11QPA4_.../WDM/02/17/VA2_OUT

L2_IN SFD44#01_.../WDM/03/9420/OUT< >11QPA4_.../WDM/02//L2_IN

16 of 30

9420IN 3,5

11QPA4 ...OUT 3,5

9430IN

WDM 02 17VA1_OUT SFD44#01_.../WDM/03/9410/IN< >11QPA4_.../WDM/02/17/VA1_OUT

L1_IN SFD44#01_.../WDM/03/9410/OUT< >11QPA4_.../WDM/02/17/L1_IN

pag

e 9410IN 3,5

11QPA4 ...OUT 3,5

SFD44#01_.../WDM/03/9400/IN< >_////

OUT SFD44#01_.../WDM/03/9400/OUT< >_////9400

IN

SFD44#01_.../WDM/03/9390/IN< >_////

0

OUT SFD44#01_.../WDM/03/9390/OUT< >_////9390

IN

SFD44#01_.../WDM/03/9380/IN< >SFD44#02_.../WDM/04/9380/OUT

OUT 2,5 IN SFD44#01_.../WDM/03/9380/OUT< >SFD44#02_.../WDM/04/9380/IN9380

IN 2,5SFD44#02 ... WDM 04 9380

OUT

04 9370OUT SFD44#01_.../WDM/03/9370/IN< >SFD44#02_.../WDM/04/9370/OUT

OUT 2,5 IN SFD44#01_.../WDM/03/9370/OUT< >SFD44#02_.../WDM/04/9370/IN9370

IN 2,5SFD44#02 ... WDM

OUT SFD44#01_.../WDM/03/9360/IN< >SFD44#02_.../WDM/04/9360/OUT

OUT 2,5 IN SFD44#01_.../WDM/03/9360/OUT< >SFD44#02_.../WDM/04/9360/IN

IN

SlotLength [m] Name Row Bay

9360

Port

2,5SFD44#02 ... WDM 04

Bay Port Label

SFD44#01 ... WDM 03

9360

Shelf

44-chan

nel static filter D

WD

M co

nn

ection

s

Kaf E

lbatiekh

From: SFD44#01 To: 11QPA4, 11DPM12, SFD44

Name Row

Part

Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

44-channel static filter DWDM connections

The following connections are to be made using cable type: SIMPLEX JUMPER (3.5M) - ETSI; DUPLEX JUMPER (3.5M) - ETSI;

Attention: Use the same label for both fibre ends

EMPTY TX skip

OUT RX skip9540

IN

skip

OUT RX skip9530

INEMPTY

TX

EMPTY TX skip

16-06-2015

OUT RX skip9520

IN

TX skip

OUT RX skip

INEMPTY

WDM 02 15VA1_OUT SFD44#01_.../WDM/03/9500/IN< >11DPM12_.../WDM/02/15/VA1_OUT

L1_IN SFD44#01_.../WDM/03/9500/OUT< >11DPM12_.../WDM/02/15/L1_IN

1.0

9500IN 3,5

11DPM12 ...OUT 3,5

9510

SFD44#01_.../WDM/03/9490/IN< >SFD44#02_.../WDM/04/9490/OUT

OUT 2,5 IN SFD44#01_.../WDM/03/9490/OUT< >SFD44#02_.../WDM/04/9490/IN9490

IN 2,5SFD44#02 ... WDM 04 9490

OUT

04 9480OUT SFD44#01_.../WDM/03/9480/IN< >SFD44#02_.../WDM/04/9480/OUT

Versio

n

OUT 2,5 IN SFD44#01_.../WDM/03/9480/OUT< >SFD44#02_.../WDM/04/9480/IN9480

IN 2,5SFD44#02 ... WDM

04 9470OUT SFD44#01_.../WDM/03/9470/IN< >SFD44#02_.../WDM/04/9470/OUT

OUT 2,5 IN SFD44#01_.../WDM/03/9470/OUT< >SFD44#02_.../WDM/04/9470/IN9470

IN 2,5SFD44#02 ... WDM

02 16VA2_OUT SFD44#01_.../WDM/03/9460/IN< >11QPA4_.../WDM/02/16/VA2_OUT

OUT 3.5 L2_IN SFD44#01_.../WDM/03/9460/OUT< >11QPA4_.../WDM/02/16/L2_IN9460

IN 3,511QPA4 ... WDM

OUT 2,5 IN SFD44#01_.../WDM/03/9450/OUT< >SFD44#02_.../WDM/04//IN

1830 PS

S-32 # 01

Teleco

m E

gyp

t

Page 19: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

17 of 30

1830 PS

S-32 # 01

EMPTY TX skip

RX skip

pag

e 9600IN

OUT

skip

OUT RX skip9590

INEMPTY

TX

EMPTY TX skip

0

OUT RX skip9580

IN

skip

OUT RX skip9570

INEMPTY

TX

EMPTY TX skip

OUT RX skip9560

IN

TX skip

OUT RX skip

IN

SlotLength [m] Name Row Bay

Port

EMPTY

Bay Port Label

SFD44#01 ... WDM 03

9550

Shelf

44-chan

nel static filter D

WD

M co

nn

ection

s

Kaf E

lbatiekh

From: SFD44#01 To:

Name Row

Part

Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

44-channel static filter DWDM connections

The following connections are to be made using cable type: LC - Duplex SM - LC, LC - Simplex SM - LC

Attention: Use the same label for both fibre ends

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n1.0

16-06-2015

Page 20: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

EMPTY TX skip

OUT RX skip

RX skip

1830 PS

S-32 # 01

9260IN

EMPTY TX skip

OUT9250

IN

TX skip

OUT RX skipEMPTY

EMPTY TX skip

RX skip

18 of 30

9230IN

OUT

9240IN

EMPTY TX skip

RX skip

pag

e 9220IN

OUT

skip

OUT RX skip9210

INEMPTY

TX

EMPTY TX skip

0

OUT RX skip9200

IN

skip

OUT RX skip9190

INEMPTY

TX

EMPTY TX skip

OUT RX skip9180

IN

TX skip

OUT RX skip

IN

SlotLength [m] Name Row Bay

Port

EMPTY

Bay Port Label

SFD44#02 ... WDM 04

9170

Shelf

44-chan

nel static filter D

WD

M co

nn

ection

s

Kaf E

lbatiekh

From: SFD44#02 To:

Name Row

Part

Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

44-channel static filter DWDM connections

The following connections are to be made using cable type:

Attention: Use the same label for both fibre ends

02 16VA1 OUT SFD44#02_.../WDM/04/9350/IN< >11QPA4_.../WDM/02/16/VA1 OUT

OUT 3,5 L1 IN SFD44#02_.../WDM/04/9350/OUT< >11QPA4_.../WDM/02/16/L1 IN9350

IN 3,511QPA4 ... WDM

SFD44#02_.../WDM/04/9340/IN< >11QPA4_.../WDM/02/12/VA2 OUT

OUT used L2 IN SFD44#02_.../WDM/04/9340/OUT< >11QPA4_.../WDM/02//L2 IN9340

IN used11QPA4 ... WDM 02 12

VA2 OUT

EMPTY TX skip

16-06-2015

OUT RX skip9330

IN

TX skip

OUT RX skip

INEMPTY

EMPTY TX skip

RX skip

1.0

9310IN

OUT

9320

skip

OUT used RX skip9300

IN usedEMPTY

TX

EMPTY TX skip

Versio

n

OUT used RX skip9290

IN used

EMPTY TX skip

OUT RX skip9280

IN

EMPTY TX skip

OUT RX skip9270

IN

OUT RX skip

1830 PS

S-32 # 01

Teleco

m E

gyp

t

Page 21: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

02 15VA2 OUT SFD44#02_.../WDM/04/9450/IN< >11QPA4_.../WDM/02/15/VA2 OUT

OUT used L2 IN SFD44#02_.../WDM/04/9450/OUT< >11QPA4_.../WDM/02//L2 IN

L2 IN SFD44#02_.../WDM/04/9440/OUT< >11QPA4_.../WDM/02/17/L2 IN

1830 PS

S-32 # 01

9450IN used

11QPA4 ... WDM

02 17VA2 OUT SFD44#02_.../WDM/04/9440/IN< >11QPA4_.../WDM/02/17/VA2 OUT

OUT used9440

IN used11QPA4 ... WDM

VA1 OUT SFD44#02_.../WDM/04/9430/IN< >11DPM12_.../WDM/02/14/VA1 OUT

OUT 3,5 L1 IN SFD44#02_.../WDM/04/9430/OUT< >11DPM12_.../WDM/02/14/L1 IN

3,511DPM12 ... WDM 02 14

WDM 02 16VA2 OUT SFD44#02_.../WDM/04/9420/IN< >11QPA4_.../WDM/02/16/VA2 OUT

L2 IN SFD44#02_.../WDM/04/9420/OUT< >11QPA4_.../WDM/02//L2 IN

19 of 30

9420IN 3,5

11QPA4 ...OUT 3,5

9430IN

WDM 02 16VA1 OUT SFD44#02_.../WDM/04/9410/IN< >11QPA4_.../WDM/02/16/VA1 OUT

L1 IN SFD44#02_.../WDM/04/9410/OUT< >11QPA4_.../WDM/02/16/L1 IN

pag

e 9410IN 3,5

11QPA4 ...OUT 3,5

SFD44#02_.../WDM/04/9400/IN< >_////

OUT SFD44#02_.../WDM/04/9400/OUT< >_////9400

IN

SFD44#02_.../WDM/04/9390/IN< >_////

0

OUT SFD44#02_.../WDM/04/9390/OUT< >_////9390

IN

SFD44#02_.../WDM/04/9380/IN< >11DPM12_.../WDM/02/11/VA1 OUT

OUT used L1 IN SFD44#02_.../WDM/04/9380/OUT< >11DPM12_.../WDM/02/11/L1 IN9380

IN used11DPM12 ... WDM 02 11

VA1 OUT

02 12VA3 OUT SFD44#02_.../WDM/04/9370/IN< >11QPA4_.../WDM/02/12/VA3 OUT

OUT 3,5 L3 IN SFD44#02_.../WDM/04/9370/OUT< >11QPA4_.../WDM/02/12/L3 IN9370

IN used11QPA4 ... WDM

VA3 OUT SFD44#02_.../WDM/04/9360/IN< >11QPA4_.../WDM/02/15/VA3 OUT

OUT 3,5 L3 IN SFD44#02_.../WDM/04/9360/OUT< >11QPA4_.../WDM/02/15/L3 IN

IN

SlotLength [m] Name Row Bay

15

Port

used11QPA4 ... WDM 02

Bay Port Label

SFD44#02 ... WDM 04

9360

Shelf

44-chan

nel static filter D

WD

M co

nn

ection

s

Kaf E

lbatiekh

From: SFD44#02 To: 11QPA4, 11DPM12

Name Row

Part

Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

44-channel static filter DWDM connections

The following connections are to be made using cable type: SIMPLEX JUMPER (3.5M) - ETSI; DUPLEX JUMPER (3.5M) - ETSI;

Attention: Use the same label for both fibre ends

EMPTY TX skip

OUT RX skip9540

IN

skip

OUT RX skip9530

INEMPTY

TX

EMPTY TX skip

16-06-2015

OUT RX skip9520

IN

TX skip

OUT RX skip

INEMPTY

WDM 02 14VA1_OUT SFD44#02_.../WDM/04/9500/IN< >11DPM12_.../WDM/02/14/VA1_OUT

L1_IN SFD44#02_.../WDM/04/9500/OUT< >11DPM12_.../WDM/02/14/L1_IN

1.0

9500IN 3,5

11DPM12 ...OUT 3,5

9510

SFD44#02_.../WDM/04/9490/IN< >SFD44#02_D/2/04/9490/OUT

OUT used IN SFD44#02_.../WDM/04/9490/OUT< >SFD44#02_D/2/04/9490/IN9490

IN usedSFD44#02 D 2 04 9490

OUT

04 9480OUT SFD44#02_.../WDM/04/9480/IN< >SFD44#02_D/2/04/9480/OUT

Versio

n

OUT used IN SFD44#02_.../WDM/04/9480/OUT< >SFD44#02_D/2/04/9480/IN9480

IN usedSFD44#02 D 2

02 7VA1_OUT SFD44#02_.../WDM/04/9470/IN< >11DPM12_.../WDM/02/7/VA1_OUT

OUT used L1_IN SFD44#02_.../WDM/04/9470/OUT< >11DPM12_.../WDM/02/7/L1_IN9470

IN used11DPM12 ... WDM

02 16VA3_OUT SFD44#02_.../WDM/04/9460/IN< >11QPA4_.../WDM/02/16/VA3_OUT

OUT 3.5 L3_IN SFD44#02_.../WDM/04/9460/OUT< >11QPA4_.../WDM/02/16/L3_IN9460

IN 3,511QPA4 ... WDM

OUT used L2 IN SFD44#02_.../WDM/04/9450/OUT< >11QPA4_.../WDM/02//L2 IN

1830 PS

S-32 # 01

Teleco

m E

gyp

t

Page 22: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

20 of 30

1830 PS

S-32 # 01

EMPTY TX skip

RX skip

pag

e 9600IN

OUT

skip

OUT RX skip9590

INEMPTY

TX

EMPTY TX skip

0

OUT RX skip9580

IN

skip

OUT RX skip9570

INEMPTY

TX

EMPTY TX skip

OUT RX skip9560

IN

TX skip

OUT RX skip

IN

SlotLength [m] Name Row Bay

Port

EMPTY

Bay Port Label

SFD44#02 ... WDM 04

9550

Shelf

44-chan

nel static filter D

WD

M co

nn

ection

s

Kaf E

lbatiekh

From: SFD44#02 To:

Name Row

Part

Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

44-channel static filter DWDM connections

The following connections are to be made using cable type: LC - Duplex SM - LC, LC - Simplex SM - LC

Attention: Use the same label for both fibre ends

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n1.0

16-06-2015

Page 23: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

1830PSS-32#01_.../WDM/n.a./A1/n.a./B OUT< >SFD44#01_.../WDM/03/n.a./INV

201

1830PSS-32#01_.../WDM/n.a./A1/n.a./B OUT< >SFD44#01_.../WDM/03/n.a./INV

A4

21 of 30

1830 PS

S-32 # 01

04 n.a. INV1830PSS-32#01_.../WDM/n.a./A2/n.a./A OUT< >DMSMF010_.../WDM/06/2/INV

0n.a. B OUT 1,5 SFD44#02 ... WDM

pag

e 1830PSS-32#01 ... WDM n.a. A2

06 2 INV1830PSS-32#01_.../WDM/n.a./A2/n.a./In< >AHPLG_.../WDM/02/4/INV

0n.a. A OUT 1,5 DMSMF010 ... WDM

0

1830PSS-32#01 ... WDM n.a. A2

1830PSS-32#01 ... WDM n.a. A2 n.a.

03 n.a. INV1830PSS-32#01_.../WDM/n.a./A2/n.a./A OUT< >DMSMF010_.../WDM/06/2/INV

0n.a. A1 n.a. B OUT 1,5 SFD44#01

1 INV1830PSS-32#01_.../WDM/n.a./A2/n.a./In< >AHPLG_.../WDM/02/4/INV

0

1830PSS-32#01 ... WDM

2

4

INV

INV

A1 n.a. A OUT 1,5 DMSMF010 ...

...

...

WDM

WDM

02

02

WDM 06

... WDM

n.a. In

In

1,5

1,5

AHPLG

AHPLG

1830PSS-32#01 ... WDM n.a. A1

1830PSS-32#01 ... WDM n.a.

Bay Shelf Slot Port LabelCard Slot Port Length [m] Name Row

Inven

tory co

nn

ection

s

Kaf E

lbatiekh

From: 1830PSS-32#01 To: SFD44

Name Row Bay Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

Inventory connections

The following connections are to be made using cable type: LAN cable with RJ11 connectors

Part

Attention: Use the same label for both fibre ends

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n1.0

16-06-2015

Page 24: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

x

RL

ALARM DDF ... ... ... ... …HK ... ... ... ...

…… … …

CRAFT

VOIP IP PHONE ... WDM 07 RJ45E2

1830PSS-32#01 ... WDM 02 40OAMP DCN/SWITCH …

DDF

Bay Shelf Block Conn.Row

E1

Management connectionsHK: 3AL17957HLAA; ALARMS: 1AC013280001 + DB15 (part of 8DG59719AA); PHONE: 1AB229830003 + RJ45

Name Row Bay Shelf Slot Conn. Name

Kaf Elbatiekh 0 Telecom Egypt

Internal Connections 1830 PSS-32 # 01

Part 2 01 page 22 of 30 Version 1.0

Attention: For detailed information see Installation Guide Version 8DG61259AAAAJZZA R6.0

16-06-2015Part 2 01 page 22 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 25: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

01 Rear 15 skip

01 Rear 16 skip

OUT 10 ODF ... ODF

Rear 13 skip

2IN 10 ODF ... ODF

Rear 14 skip

OUT 10 ODF ... ODF 01

IN 10 ODF ... ODF 011

01 Rear 7 1830 PSS-32_.../WDM/02/17/OUT< >ODF_.../ODF/01/Rear/7

17

1830 PS

S-32 # 01

01

1830 PSS-32 ... WDM 02

Rear 8 1830 PSS-32_.../WDM/02/17/IN< >ODF_.../ODF/01/Rear/8

OUT 10 ODF ... ODF

Rear 11 1830 PSS-32_.../WDM/02/17/OUT< >ODF_.../ODF/01/Rear/11

4IN 10 ODF ... ODF

OUT 10 ODF ... ODF 01

ODF 01 Rear 12 1830 PSS-32_.../WDM/02/17/IN< >ODF_.../ODF/01/Rear/12

Rear 7 1830 PSS-32_.../WDM/02/17/OUT< >ODF_.../ODF/01/Rear/7

23 of 30

3IN 10 ODF ...

OUT 10 ODF ... ODF 01

ODF 01 Rear 8 1830 PSS-32_.../WDM/02/17/IN< >ODF_.../ODF/01/Rear/8

01 Rear 5 1830 PSS-32_.../WDM/02/17/OUT< >ODF_.../ODF/01/Rear/5

2IN 10 ODF ...

Rear 6 1830 PSS-32_.../WDM/02/17/IN< >ODF_.../ODF/01/Rear/6

pag

e

OUT 10 ODF ... ODF

IN 10 ODF ... ODF 01

Rear 4 1830 PSS-32_.../WDM/02/16/IN< >ODF_.../ODF/01/Rear/4

1

ODF 01 Rear 3 1830 PSS-32_.../WDM/02/16/OUT< >ODF_.../ODF/01/Rear/3

0

OUT 10 ODF ...

Rear10 ODF ... ODF

4IN 10 ODF ... ODF

OUT

01

01

ODF 01 Rear 6 1830 PSS-32_.../WDM/02/16/IN< >ODF_.../ODF/01/Rear/6

5 1830 PSS-32_.../WDM/02/16/OUT< >ODF_.../ODF/01/Rear/5

ODF

01 Rear 3 1830 PSS-32_.../WDM/02/16/OUT< >ODF_.../ODF/01/Rear/3

01IN 10 ODF ... ODF

OUT 10 ODF ...2

3IN 10 ODF

Rear 4 1830 PSS-32_.../WDM/02/16/IN< >ODF_.../ODF/01/Rear/4

1830 PSS-32_.../WDM/02/16/OUT< >ODF_.../ODF/01/Rear/1

01 Rear 2 1830 PSS-32_.../WDM/02/16/IN< >ODF_.../ODF/01/Rear/2

Rear 1

16

1IN 10 ODF ...

OUT 10

...

ODF ...

Shelf Side Port EtykietaRow Bay

ODF 01

ODF

1830 PSS-32 ... WDM 02

Slot Port Lenght [m] Name

11G clien

t sign

als 1830 PS

S-32 d

o O

DF

Kaf E

lbatiekh

From: 1830 PSS-32 To: ODF

Name Row Bay Shelf

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

11G client signals 1830 PSS-32 do ODF

Typ kabla: OPTO CABLE ASSEMBLY SX 2.0 SM SC/PC-LC/PC 10M Y INDOOR

Part

Rear 7 skipOUT 10 ODF ... ODF 01

ODF 01 Rear 8 skip

01 Rear 23 skip

4IN 10 ODF ...

01 Rear 24 skip

OUT 10 ODF ... ODF

Rear 21 skip

3IN 10 ODF ... ODF

OUT 10 ODF ... ODF 01

ODF 01 Rear 22 skip

01 Rear 19 skip

2IN 10 ODF ...

01 Rear 20 skip

OUT 10 ODF ... ODF1

IN 10 ODF ... ODF

01 Rear 7 skip

1830 PSS-32 ... WDM 02 EMPTY

01 Rear 8 skip

OUT 10 ODF ... ODF

Rear 17 skip

4IN 10 ODF ... ODF

OUT 10 ODF ... ODF 01

ODF 01 Rear 18 skip

01 Rear 15 skip

3IN 10 ODF ...

OUT 10 ODF ... ODF1830 PSS-32 ... WDM 02 EMPTY

1.016-06-2015

Uwaga: użyj jednakowych etykiet na obu końcach kabla

Teleco

m E

gyp

t

1830 PS

S-32 # 01

Versio

n

Page 26: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

1 IN

DWDM

1830 PS

S-32 # 01

WDM/11DPM12/Sh 02/Sl 14/10 OUT <=> ///

WDM/11DPM12/Sh 02/Sl 14/10 IN <=> ///

10 OUT

10 IN

WDM/11DPM12/Sh 02/Sl 14/9 OUT <=> ///

WDM/11DPM12/Sh 02/Sl 14/9 IN <=> ///

9 OUT

15 WDM/11DPM12/Sh 02/Sl 14/8 OUT <=> ODF/02/Rear/15

9 IN

16 WDM/11DPM12/Sh 02/Sl 14/8 IN <=> ODF/02/Rear/16

8 OUT 10 ODF ... ODF 02 Rear

13 WDM/11DPM12/Sh 02/Sl 14/7 OUT <=> ODF/02/Rear/13

8 IN 10 ODF ... ODF 02 Rear

14 WDM/11DPM12/Sh 02/Sl 14/7 IN <=> ODF/02/Rear/14

7 OUT 10 ODF ... ODF 02 Rear

11 WDM/11DPM12/Sh 02/Sl 14/6 OUT <=> ODF/02/Rear/11

24 of 30

7 IN 10 ODF ... 02 Rear

12 WDM/11DPM12/Sh 02/Sl 14/6 IN <=> ODF/02/Rear/12

6 OUT 10 ODF ... ODF 02 Rear

9 WDM/11DPM12/Sh 02/Sl 14/5 OUT <=> ODF/02/Rear/9

pag

e

6 IN 10 ODF ... 02 Rear

10 WDM/11DPM12/Sh 02/Sl 14/5 IN <=> ODF/02/Rear/10

5 OUT 10 ODF ... ODF 02 Rear

7 WDM/11DPM12/Sh 02/Sl 14/4 OUT <=> ODF/02/Rear/7

5 IN 10 ODF ... ODF 02 Rear

8 WDM/11DPM12/Sh 02/Sl 14/4 IN <=> ODF/02/Rear/8

0

4 OUT 10 ODF ... 02 Rear

5 WDM/11DPM12/Sh 02/Sl 14/3 OUT <=> ODF/02/Rear/5

4 IN 10 ODF ... ODF 02 Rear

6 WDM/11DPM12/Sh 02/Sl 14/3 IN <=> ODF/02/Rear/6

3 OUT 10 ODF ... ODF 02 Rear

3 WDM/11DPM12/Sh 02/Sl 14/2 OUT <=> ODF/02/Rear/3

3 IN 10 ODF ... ODF 02 Rear

4 WDM/11DPM12/Sh 02/Sl 14/2 IN <=> ODF/02/Rear/4

2 OUT 10 ODF ... 02 Rear

1 WDM/11DPM12/Sh 02/Sl 14/1 OUT <=> ODF/02/Rear/1

2 IN 10 ODF ... ODF 02 Rear

1 OUT 10 ODF ... ODF 02

10 ODF ... ODF

ODF

ODF

1830 PSS-32 ... WDM 02 14

11DP

M12 clien

t sign

als to O

DF

Kaf E

lbatiekh

From: 1830 PSS-32

Etykieta

ODF

ODF

02 Rear 2 WDM/11DPM12/Sh 02/Sl 14/1 IN <=> ODF/02/Rear/2

Rear

Name Row Bay Shelf Side Port

To: ODF

Name Row Bay Shelf Slot Wave Port Lenght [m]

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

11DPM12 client signals to ODF

The following connections are to be made using cable type: OPTO CABLE ASSEMBLY SX 2.0 SM SC/PC-LC/PC 10M Y INDOOR

Part

WDM/11DPM12/Sh 02/Sl 14/LINE 2 OUT <=> ///LINE 2 OUT

1.016-06-2015

Uwaga: użyj jednakowych etykiet na obu końcach kabla

WDM/11DPM12/Sh 02/Sl 14/LINE 2 IN <=> ///

WDM/11DPM12/Sh 02/Sl 14/VA1 OUT <=> ///

LINE 2 IN

WDM/11DPM12/Sh 02/Sl 14/LINE1 IN <=> ///

Versio

n

VA1 OUT used

1830 PS

S-32 # 01 WDM/11DPM12/Sh 02/Sl 14/12 OUT <=> ///

LINE1 IN used

WDM/11DPM12/Sh 02/Sl 14/12 IN <=> ///

12 OUT

WDM/11DPM12/Sh 02/Sl 14/11 OUT <=> ///

12 IN

WDM/11DPM12/Sh 02/Sl 14/11 IN <=> ///

11 OUT

WDM/11DPM12/Sh 02/Sl 14/10 OUT <=> ///

11 IN

10 OUT

Teleco

m E

gyp

t

Page 27: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

201

A4

1 IN

DWDM

1830 PS

S-32 # 01

WDM/11DPM12/Sh 02/Sl 15/10 OUT <=> ///

WDM/11DPM12/Sh 02/Sl 15/10 IN <=> ///

10 OUT

10 IN

WDM/11DPM12/Sh 02/Sl 15/9 OUT <=> ///

WDM/11DPM12/Sh 02/Sl 15/9 IN <=> ///

9 OUT

31 WDM/11DPM12/Sh 02/Sl 15/8 OUT <=> ODF/02/Rear/31

9 IN

32 WDM/11DPM12/Sh 02/Sl 15/8 IN <=> ODF/02/Rear/32

8 OUT 10 ODF ... ODF 02 Rear

29 WDM/11DPM12/Sh 02/Sl 15/7 OUT <=> ODF/02/Rear/29

8 IN 10 ODF ... ODF 02 Rear

30 WDM/11DPM12/Sh 02/Sl 15/7 IN <=> ODF/02/Rear/30

7 OUT 10 ODF ... ODF 02 Rear

27 WDM/11DPM12/Sh 02/Sl 15/6 OUT <=> ODF/02/Rear/27

25 of 30

7 IN 10 ODF ... 02 Rear

28 WDM/11DPM12/Sh 02/Sl 15/6 IN <=> ODF/02/Rear/28

6 OUT 10 ODF ... ODF 02 Rear

25 WDM/11DPM12/Sh 02/Sl 15/5 OUT <=> ODF/02/Rear/25

pag

e

6 IN 10 ODF ... 02 Rear

26 WDM/11DPM12/Sh 02/Sl 15/5 IN <=> ODF/02/Rear/26

5 OUT 10 ODF ... ODF 02 Rear

23 WDM/11DPM12/Sh 02/Sl 15/4 OUT <=> ODF/02/Rear/23

5 IN 10 ODF ... ODF 02 Rear

24 WDM/11DPM12/Sh 02/Sl 15/4 IN <=> ODF/02/Rear/24

0

4 OUT 10 ODF ... 02 Rear

21 WDM/11DPM12/Sh 02/Sl 15/3 OUT <=> ODF/02/Rear/21

4 IN 10 ODF ... ODF 02 Rear

22 WDM/11DPM12/Sh 02/Sl 15/3 IN <=> ODF/02/Rear/22

3 OUT 10 ODF ... ODF 02 Rear

19 WDM/11DPM12/Sh 02/Sl 15/2 OUT <=> ODF/02/Rear/19

3 IN 10 ODF ... ODF 02 Rear

20 WDM/11DPM12/Sh 02/Sl 15/2 IN <=> ODF/02/Rear/20

2 OUT 10 ODF ... 02 Rear

17 WDM/11DPM12/Sh 02/Sl 15/1 OUT <=> ODF/02/Rear/17

2 IN 10 ODF ... ODF 02 Rear

1 OUT 10 ODF ... ODF 02

10 ODF ... ODF

ODF

ODF

1830 PSS-32 ... WDM 02 15

11DP

M12 clien

t sign

als to O

DF

Kaf E

lbatiekh

From: 1830 PSS-32

Etykieta

ODF

ODF

02 Rear 18 WDM/11DPM12/Sh 02/Sl 15/1 IN <=> ODF/02/Rear/18

Rear

Name Row Bay Shelf Side Port

To: ODF

Name Row Bay Shelf Slot Wave Port Lenght [m]

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-L

ucen

t - Pro

prietary

11DPM12 client signals to ODF

The following connections are to be made using cable type: OPTO CABLE ASSEMBLY SX 2.0 SM SC/PC-LC/PC 10M Y INDOOR

Part

WDM/11DPM12/Sh 02/Sl 15/LINE 2 OUT <=> ///LINE 2 OUT

1.016-06-2015

Uwaga: użyj jednakowych etykiet na obu końcach kabla

WDM/11DPM12/Sh 02/Sl 15/LINE 2 IN <=> ///

WDM/11DPM12/Sh 02/Sl 15/VA1 OUT <=> ///

LINE 2 IN

WDM/11DPM12/Sh 02/Sl 15/LINE1 IN <=> ///

Versio

n

VA1 OUT used

1830 PS

S-32 # 01 WDM/11DPM12/Sh 02/Sl 15/12 OUT <=> ///

LINE1 IN used

WDM/11DPM12/Sh 02/Sl 15/12 IN <=> ///

12 OUT

WDM/11DPM12/Sh 02/Sl 15/11 OUT <=> ///

12 IN

WDM/11DPM12/Sh 02/Sl 15/11 IN <=> ///

11 OUT

WDM/11DPM12/Sh 02/Sl 15/10 OUT <=> ///

11 IN

10 OUT

Teleco

m E

gyp

t

Page 28: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

x

GND YE/GR GND GND< >GND02 36

+Bat1 B1/63A/RTN< >+Bat1

-48V BLACK -Bat1 B1/63A/-48V< >-Bat1

10mm2

RED

... WDM

A1/63A/RTN< >+Bat2

-48V BLUE -Bat2 A1/63A/-48V< >-Bat2

... WDM B1/63A

RTN

2,5

A1/63A/RTN< >+Bat1

-48V BLACK -Bat1 A1/63A/-48V< >-Bat1

GND YE/GR GND GND< >GND

RED

... WDM 02 19

+Bat1

BROWN +Bat2

... WDM A1/63A

RTN

2,5 10mm2

RTN

Colour Row Bay Shelf SlotRow BayFuse/size

Conn. Length Size

Internal DC power connectionsCable Type: Power Cable (See below for sizes)

From: PDU To: 1830PSS-32#01 / IP PHONE

BLUE... WDM

-48V_B DC BOX_…/DC BOX/ModB/…< >PDU_.../WDM/-48V_B

RET BROWN BRTN DC BOX_…/DC BOX/ModB/RET< >PDU_.../WDM/BRTN

RET BROWN ARTN DC BOX_…/DC BOX/ModA/RET< >PDU_.../WDM/ARTN

… DC BOX B…A

8m 25mm2

25mm2BLUE

... WDM-48V_A DC BOX_…/DC BOX/ModA/…< >PDU_.../WDM/-48V_A

Colour Row BayPower Input

Label

… DC BOX A…A

8m

Row Bay Mod Fuse/ Size Length Size

Cable Type: Power Cable (See below for sizes) From: DC BOX To: PDU

External DC power connections

PDU (Power Distribution Unit) with reference part nr. 1AF17443AAAA

Note: All infromation marked with "..." will be updated with As Built Document.

Kaf Elbatiekh 0 Telecom Egypt

Cable List Power Supply 1830 PSS-32 # 01

Part 2 01 page 26 of 30 Version 1.0 16-06-2015

GND YE/GR GND GND< >GND

RED

Attention: For detailed information see Installation Guide Version 8DG61259AAAAJZZA 6.0

n.a.

Input + Ve

-48V BLUE -Bat2A3/1A/RTN< >Input + Ve

-48V BLUE Input - Ve A3/1A/-48V< >Input - Ve

B1/63A/-48V< >-Bat2

... WDM A3/1A

RTN

3 2.5mm2 ... WDM 07

GND YE/GR GND

RTN BROWN +Bat2 B1/63A/RTN< >+Bat2

02 3610mm2 ... WDM... WDM B1/63A 2,5

Part 2 01 page 26 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 29: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

x

YL/GR GND N/A

GND N/A

YL/GR GND N/A

Label

FRMGND

YL/GR 16mm2 1830PSS-32#01 GND N/A

YL/GR 16mm2 1830PSS-32#02

Equipment GroundingCable Type: see below

From Bay Ground Rail BarCable To equipment

Colour TypeEquipment

Name Input

Connector Label

… … … ... WDM FRMGND RGRB_…/…/…< >BGRB_.../WDM/FRMGND

Cabinet GroundingCable Type: VD CABLE 25mm2 YL/GN

From Room Ground Rail Bar To Bay Ground Rail BarRow Bay Connector Row Bay

Kaf Elbatiekh 0 Telecom Egypt

Cable List Grounding 1830 PSS-32 # 01

Part 2 01 page 27 of 30 Version 1.0 16-06-2015Part 2 01 page 27 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 30: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Kaf Elbatiekh 0 Telecom Egypt

Appendix A - Floor Plan layout 1830 PSS-32 # 01

Part 2 01 page 28 of 30 Version 1.0 16-06-2015Part 2 01 page 28 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 31: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Storage Tray

01 ODF

Storage Tray

02 ODF04 ODF

Storage Tray

03 ODF

Storage Tray

04 ODF

Storage Tray

Storage Tray

Storage Tray

Storage Tray

ODF RACK 2200x600x300 [HxWxD]CABINET 600X2200X300MM [WxHxD] 21IN 47U WITHOUT DOOR

Kaf Elbatiekh 0 Telecom Egypt

Appendix B - ODF layout 1830 PSS-32 # 01

Part 2 01 page 29 of 30 Version 1.0 16-06-2015Part 2 01 page 29 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 32: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Kaf Elbatiekh 0 Telecom Egypt

Appendix C1 - HK and Rack alarm 1830 PSS-32 # 01

Part 2 01 page 30 of 30 Version 1.0 16-06-2015Part 2 01 page 30 of 30 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 33: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

1660SM #01

Initial Document

Office Data Manual (ODM)

SITE NAME: Kaf Elbatiekh

Customer No:

Customer Name:

SAP Network ID:

0

Telecom Egypt

SITE ADRESS:

Page 34: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Equipment Number : 01

Version 1.0Document PurposeFinal Document Verification Date N/ADocument EngineerDocument Helpdesk Telephone Number Technical Support Helpdesk Telephone NumberTechnical Support Helpdesk Mail AddressSAP Network IDAllView Number

For Installation instructions see : See Floor LayoutTechnical Handbook Version NameTechnical Handbook Release IssueInstallation Handbook Version DateInstallation Handbook Release

Work Description

Alcatel-Lucent Document Control

Document Author

8DG 15642 BAAA 5,5

8DG 15642 AAAA

BASE: DASH:

N/A

Initial Document

Bartosz Górny

Alcatel-Lucent Document Number1660 SM

Egypt

Telecom EgyptPO#14 - Domietta Ring

Kaf Elbatiekh

5,5

Installation new shelf 1660SM

Document Author

Name

Signed

Checked by Approved by

Name Name

Signed Signed

Post Installation As Built Verification

Alcatel-Lucent Representative Customer Representative

Name Name

Date Date

Signed Signed

Kaf Elbatiekh

Document Information Sheet 1660 SM # 01

Part 2 02 page 1 Version 1.0

16-06-2015

Bartosz Górny

Part 2 02 page 1 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights ReservedR5.x_Va3 A4

16-06-2015

Page 35: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

DOCUMENT CHANGE HISTORY

Date

1.0 I Initial ODM Bartosz Górny 16-06-2015

Version Status Reason for Change / Re Issue Engineer

I - Initial ODM # - NewF - Final ODM * - Removed

& - Transferred (moved)% - Changed

Kaf Elbatiekh

Survey of Changes 1660 SM # 01

Part 2 02 page 2 Version 1.0 16-06-2015Part 2 02 page 2 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 36: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Part Number Description Page

2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 2 2 6 2 2 7 2 2 8 2 2 9 2 2 10 2 2 11 2 2 12 2 2 13 2 2 14 2 2 15 2 2 16 2 2 17

Document Information Sheet

Survey of Changes

Index

System Diagram

Material Specification Hardware

Site Materials Specification

Front View Rack Layout

Front View Subrack Layout

Circuit pack placement

SFP and Modules

SFP and Modules

XFP and Modules

Cable List 48V DC Power Supply

Cable List Grounding

STM-1 connections 1660SM to ODF

1GbEth connections 1660SM to ODF

STM-64 connections 1660SM to ODF 2 2 17 2 2 18 2 2 19 2 2 20 2 2 21 2 2 22 2 2 23

Kaf Elbatiekh

Index 1660 SM # 01

Part 2 02 page 3 Version 1.0 16-06-2015

STM-64 connections 1660SM to ODF

External connections of 1660SM

Synchronization for 1660SM

External connections of 1660SM

Appendix A

Appendix B

Appendix C

Part 2 02 page 3 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 37: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Row Bay Shelf

SLT

23

P16S1-4E

CO-64

Blank

ACCESS AREA

Blank

Blank

A12OS1SE

Blank

Blank

Blank

Blank

Blank

Blank

BASIC AREA

Front View Rack Layout 1660SM

... SDH 02

Blank

SLT

7

Blank

Blank

Blank

SLT

1S

LT2

SLT

3S

LT4

SLT

5S

LT6

SLT

8S

LT9

SLT

13S

LT14

SLT

15S

LT16

MATRIXE

Blank

CO-64

Blank

Blank

Blank

Blank

Blank

Blank

Blank

SLT

24S

LT25

SLT

26S

LT27

SLT

28S

LT29

SLT

30S

LT31

SLT

32S

LT33

SLT

34S

LT35

1660 SM

Kaf Elbatiekh

System Diagram 1660 SM # 01

Part 2 02 page 4 Version 1.0

SLT

40

MATRIXE

GETH-AGR

16-06-2015

SLT

17S

LT18

SLT

19S

LT20

Blank

SLT

21

Blank

Blank

Blank

ISA-ES16

Blank

Blank

Blank

SLT

38S

LT39

SLT

36S

LT37

Part 2 02 page 4 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 38: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

HCheck off

3AL35060AAXX ETSI ONE RACK WITH TRU8DG09119AAAA DOOR ASSEMBLIES3AL78817AA** SERVICES I/F3AL78836AD** EQUICO E DCC ENH3AL79266AA** CAPS ESD COM. PART OMSN3AN49399AA** DUMMY PLATE W 303CA08540AA** 19"/21" ADAPTER KIT3AN49400AA** DUMMY PLATE W 351AB162710015 CIRCUIT BREAKER 40A 72VCC3AL81202AA** KIT T_BUS UPGRADE FOR ISA APPLIC3AL81639AA** KIT-CABLING ETHERNET3AL91653AAAA INST. KIT 1660SM SUBRACK WITH FANS3AN50125AA** 120OHM KIT FOR CABLE SUPPORT3AL89561AB** ASSEMBLED FANS UNIT8DG15411AAAA ETSI TRAY WITH AIR DEFLECTOR FOR ASSEMBLED FAN UNIT1AB162710005 CIRCUIT BREAKER 10A 72VDC3AL89794AB** 1660SM SUBRACK WITH INTEGRATED FAN SHELF8DG15611AA** MATRIX ENHANCED8DG15663AMAA SWP-1660SM_SDH R.5.5 A88DG16038AMAA SWPL-1660SM_SDH R.5.5 A83AL78830AE** CONTROL AND GENERAL I/F (2 WIRES / 960W / 25A / WITH FAN SUPERVISION)1AB147830012 256MB COMPACT FLASH CARD (-40/+85C)1AB074610019 CONN.RJ45 M. 8 WIRES IDC CAT.63AN49397AA** DUMMY PLATE W 203AL89857AAAA SFP DUMMY PLUG KIT8DG15701AA** PORT 16XSTM1 - 4XSTM4 DCC ENH8DG15540ACAA ESWL-OMSN METRO VERS. "A" TDM LP8DG15432AA** STM64 PORT XFP PLUGGABLE8DG15540ACAA ESWL-OMSN METRO VERS. "A" TDM LP3AL91880AA** OPTICAL ACCESS 12XSTM1 SLIM1AB194670007 OPTO TRX SFP S-1.1 DDM -40/+853AL91721AAAA XFP-E ADAPTER1AB214540001 XFP I-64.1/10GBE BASE L1AF00398AAAA TELEPHONE HANDSET8DG15235AA** 4XGE SFP ES-16 ACCESS8DG15540ABAA ESWL-OMSN METRO VERS. "A" ETH LP

11

11

Ordercode Comcode Description Qty

11

111121

1212121121131

18

118240116221

8DG15540ABAA ESWL-OMSN METRO VERS. "A" ETH LP1AB187280031 OPTO TRX SFP 1GBE LX DDM3AL81915BA** ISA-ES16 ENH SERIES8DG16021ACAA SWPL-ES16B ENH R.2.4B1 PLUS8DG15540ABAA ESWL-OMSN METRO VERS. "A" ETH LP

Kaf Elbatiekh

Material Specification Hardware 1660 SM # 01

Part 2 02 page 5 Version 1.0

841

16-06-2015

Note : The Installer shall use this sheet to check that all materials have been delivered

16

Part 2 02 page 5 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 39: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

HCheck off

Rack accessories300507449 INSULATING TAPE 19.1MM X 4.572MR BLACK VELCRO

Power cables 16mm2 /1662SMC/1AC029050002 CABLE POWER PVC BLACK 2X16MM2

GND cable 25mm2 /internal grounding; 1662SMC/1AC053180008 CABLE POWER LS0H GREEN/YELLOW 16MM2

Alarm cables OPTINEX TRU to DDF1AB200670003 CABLE ASSEMBLY HE5 MALE 9PTS-N/C 15M

Internal cable for FAN-1660SM CONGI [HK+ALARM]3AL18034CNAA CLEE 2 Q HF HE5-15MC/15M

HK 1660SM3AL17956HLAA ALARMS CABLE EQPT/DDF L=25M

VDS 1660SM1AB200480001 CABLE ASSEMBLY HE5-50M-N/C 25M

SYNCHRONIZATION CABLE 120OHM1AB200560001 CLER 4P HF 1.0/2.3 BAL 25 m

TB for E1, HK, VDS, alarm TRU1AD021330001 2 X1/2 COVER-ACCESSORY FOR COMPAX+ LABEL

1AC014270015 MOUNTING STRIP, 89713

Handset support3AL17213AAAB HANDSET SUPPORT

Fibers to internal or LINE ODF1AB346850008 OPTO CABLE ASSEMBLY SX 2.0 SM SC/PC-LC/PC 10M Y INDOOR

Protection pipe1AC044110001 CABLE PIPING ROUND TUBE 17MM

Installation kit1AD041540001 SET SCREW - INSTALLATION OF STATION /S9

ODF1AD082730006 OPTICAL PATCHING MODULE 1U - 36 ADAPTORS

1AD082730004 STORAGE OPTICAL MODULE 1U - 36 PATCHCORDS OR JUMPERS , LEFT OR RIGHT OPENING, 10080280

3CT01050AAAA SET OF 2 SC/PC OPTICAL ADAPTOR

Ordercode Comcode Description Qty

1

16

8

1

1

1

1

1

7

7

1

44

30

1

2

2

22

Kaf Elbatiekh

Site Materials Specification 1660 SM # 01

Part 2 02 page 6 Version 1.0

Note : The Installer shall use this sheet to check that all materials have been delivered

16-06-2015Part 2 02 page 6 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 40: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Row ... Bay SDH 02

01 TRU

02 1660SM #01

L1: slot 25, dir. Sisi HenieshL2: slot 26, dir. El SahelL3: slot 27, dir. Ras El-HekmaL4: slot 30, dir. FokaL5: slot 31, dir. Alam Mariam

03 FAN UNIT

Front View Rack Layout 1660SM

Kaf Elbatiekh

Front View Rack Layout 1660 SM # 01

Part 2 02 page 7 Version 1.0 16-06-2015

21” rack 2200x600x300

Part 2 02 page 7 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 41: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Row Bay 02

System name:

1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 21

22 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 41

Bla

nk

CO

NG

I

MA

TR

IXE

Bla

nk

Shelf

Front View Subrack Layout

Bla

nk

Bla

nk

Bla

nk

Bla

nkS

ER

VIC

E

CO

NG

I

... SDH

11

Bla

nk

1660SM

Bla

nk

Bla

nk

Bla

nk

Bla

nk

A12

OS

1SE

Bla

nk

CO

-64

Bla

nk

Bla

nk

Bla

nk

MA

TR

IXE

PQ

2/E

QC

Bla

nk

23

Bla

nk

Bla

nk

GE

TH

-AG

R

P16

S1-

4E

CO

-64

Bla

nk

Bla

nk

Bla

nk

Bla

nk40

Bla

nk

Bla

nk

Bla

nk

ISA

-ES

16

Bla

nk

Bla

nk

Bla

nk

Kaf Elbatiekh

Front View Subrack Layout 1660 SM # 01

Part 2 02 page 8 Version 1.0

MA

TR

IXE

Bla

nk

Bla

nk

FANS

16-06-2015

CO

-64

Bla

nk

MA

TR

IXE

PQ

2/E

QC

Bla

nk

P16

S1-

4E

CO

-64

Bla

nk

Bla

nk

Bla

nk

Bla

nk

Bla

nk

ISA

-ES

16

Bla

nk

Bla

nk

Bla

nk

Part 2 02 page 8 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 42: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

Row Bay Shelf 02

System name:

t.b.d t.b.d29 Blank

27 Blank

28 Blank

t.b.d

t.b.d t.b.d

t.b.d t.b.d

t.b.d t.b.d

t.b.d t.b.d

t.b.d

26 Blank

24 Blank

25 CO-64

t.b.d

3AL78836AD-- t.b.d

21 Blank Blank t.b.d

22 PQ2/EQC EQUICO E DCC ENH

MATRIX ENHANCED23

t.b.d

MATRIXE 8DG15611AA--

18 Blank Blank t.b.d

19 Blank

20 Blank

t.b.dBlank

Blank

16 Blank Blank t.b.d

Blank

8DG 15235 AA-- t.b.d17 GETH-AGR

14 A12OS1SE OPTICAL ACCESS 12xSTM1 SLIM

15 Blank

t.b.d

3AL 91880 AA-- t.b.d

t.b.d t.b.d

CONTROL AND GENERAL INTERFACE

t.b.dBlank13 Blank

12 CONGI

3AL78830AE-- t.b.d

Blank

10 CONGI CONTROL AND GENERAL INTERFACE

Blank

9 Blank

8

t.b.d

Blank

6 Blank Blank

Blank

t.b.dSERVICES I/F11 SERVICE

Blank

7

t.b.d

Blank Blank

2 Blank Blank

3 Blank Blank

4 Blank

5 Blank Blank

Blank

t.b.d

t.b.d t.b.d

t.b.d t.b.d

t.b.d

t.b.d

t.b.d t.b.d

t.b.d

3AL78817AA--

t.b.d

t.b.dt.b.d

t.b.d

t.b.d t.b.d

3AL78830AE-- t.b.d

1660SM

... SDH

t.b.d

Card Description1

Slot App. Code Part Number Clei Code

Blank

GIGABIT ETHERNET ACCESS

t.b.d

t.b.d

8DG15432 AA--

t.b.d

CIRCUT PACKS PLACEMENT

Blank

Blank

Blank

STM64 PORT XFP PLUGGABLE

Blank

Kaf Elbatiekh

Circuit pack placement 1660 SM # 01

Part 2 02 page 9 Version 1.0

31 Blank

32 Blank

t.b.d t.b.d

t.b.d t.b.d

t.b.d t.b.d

t.b.d t.b.d

3AL81915 BA-- t.b.d

t.b.d

t.b.d t.b.d

t.b.d t.b.d

29 Blank

30 Blank

8DG15432 AA-- t.b.d

8DG15701AA-- t.b.d

34 CO-64

33 P16S1-4E

35 Blank

36 ISA-ES16

37 Blank

39 Blank

38 Blank

40 MATRIXE

MATRIX ENHANCED

t.b.d t.b.d

8DG15611AA-- t.b.d

16-06-2015

t.b.d

Blank

Blank

Blank

16xSTM1 - 4xSTM4 DCC ENH

STM64 PORT XFP PLUGGABLE

Blank

ISA-ES16 ENH SERIES

Blank

Blank

Blank

Blank

Part 2 02 page 9 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 43: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

1AB 194670007 t.b.d

3 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

2 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85

Clei Code

1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

Card Pos.

Mod. Pos.

Module App. Code

Module Description Comcode

12 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

P16S1-4E

10 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

11 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

8 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

9 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

6 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

7 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

5 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

3 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

Comcode Clei Code

14

1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

2 SS-1.1

A12OS1SE

33

1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85

Card Pos.

Mod. Pos.

Module App. Code

Module Description

3 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

1AB 194670007 t.b.d

2 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

P16S1-4E

Card Pos.

Mod. Pos.

Module App. Code

Module Description Comcode Clei Code

31

Kaf Elbatiekh

SFP and Modules 1660 SM # 01

Part 2 02 page 10 Version 1.0 16-06-2015

4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

1AB 194670007

A12OS1SE

Card Pos.

Mod. Pos.

Module App. Code

Module Description Comcode Clei Code

t.b.d

9

1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

2 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85

5 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

t.b.d

3 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007

7 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

9 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

6 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

11 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

8 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

12 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

10 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

Part 2 02 page 10 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 44: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

29

1 SS-4.1 #N/A

3 SS-4.1 #N/A #N/A #N/A

4 SS-4.1 #N/A #N/A #N/A

Clei Code

1AB187280031

t.b.d

#N/A #N/A

2 SS-4.1 #N/A #N/A #N/A

Card Pos.

Mod. Pos.

Module App. Code

Module Description Comcode

P16S1-4E

17

1 1GBE LX OPTO TRX SFP 1GBE LX DDM

3 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d

4 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d

1AB187280031 t.b.d

2 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d

GETH-AGR

Card Pos.

Mod. Pos.

Module App. Code

Module Description Comcode Clei Code

20

1 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d

2 1GBE LX OPTO TRX SFP 1GBE LX DDM

4 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d

t.b.d

3 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031

Kaf Elbatiekh

SFP and Modules 1660 SM # 01

Part 2 02 page 11 Version 1.0 16-06-2015

12 Empty

10 Empty

11 Empty

8 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

9 Empty

6 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

7 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

5 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

3 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

Comcode Clei Code

7

1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d

2 SS-1.1

A12OS1SE

Card Pos.

Mod. Pos.

Module App. Code

Module Description

4 SS-4.1 #N/A #N/A #N/A

Part 2 02 page 11 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 45: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

CO-64

Card Pos.

Mod. Pos.

Module App. Code

Module Description Comcode Clei Code

25 1 I-64.1/10GBE XFP I-64.1/10GBE BASE L 1AB214540001 t.b.d

34 1 I-64.1/10GBE XFP I-64.1/10GBE BASE L 1AB214540001 t.b.d

33 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d

OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d

34 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d

35 1 SS-16.1

Kaf Elbatiekh

XFP and Modules 1660 SM # 01

Part 2 02 page 12 Version 1.0 16-06-2015Part 2 02 page 12 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 46: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

x

... SDH 03

1

... SDHM2-2

M8-1

M2-1

M8-2

N1

TRU_M8< >1660SM_03/2/N2/FAN POWER

Bay Shelf

TRU_M2< >1660SM_03/1/N1/FAN POWER

Slot

N22

Label

From TRU to Fan Unit Shelf

TRU To: Fan Unit ShelfRow Bay Power-Output Row

Cable Type: Power Cord 48V (delivered with shelf)

12

To:

M7-2

M1-2

M1-1

M7-1

Cable Type: CA-CORD PLUG ALIM. part of kit - 3AL91653AAAA

From : DC BOX TRU

To 1660SM Shelf

Label

DC BOX_n.a./DC BOX/ModB/…< >TRU_.../SDH/b-

DC BOX_n.a./DC BOX/ModB/RET< >TRU_.../SDH/b+

SDH

BayPower Input

Length

BROWN

RowRow Bay Mod Fuse/ Size

DC BOXa+

16mm2

Size Colour

a-BLUE

...

From Power Distribution Frame to TRU

BayPower-Output Row

Cable Type: Power Cable (See below for sizes)

n.a. ADC BOX_n.a./DC BOX/ModA/RET< >TRU_.../SDH/a+

DC BOX_n.a./DC BOX/ModA/…< >TRU_.../SDH/a-

DC BOX

8m

B...A

8m

...A

RET

RET

b-16mm2

+Bat.... SDH

+Bat.

-Bat.

BROWN

BLUE

SlotTRU

b+

From TRU to 1660 SM

Row LabelShelf

Attention: For detailed information see Technical H andbook Version 8DG 15642 AAAA R5.5

n.a.

TRU_M1< >1660SM_02/10/POWER

Bay

TRU_M7< >1660SM_02/12/POWER

SDH...-Bat.

10

02

Conn.

Kaf Elbatiekh

Cable List 48V DC Power Supply 1660 SM # 01

Part 2 02 page 13 Version 1.0 16-06-2015 Part 2 02 page 13 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 47: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

x

YL/GR

YL/GR

Label

FRMGND

YL/GR 1660SM#01 GND N/A

YL/GR

Equipment GroundingCable Type: see below

From: Bay Ground Rail BarCable To: equipment

Colour TypeEquipment

Name Input

Connector Label

n.a. n.a. ... ... SDH FRMGND RGRB_n.a./n.a./...< >BGRB_.../SDH/FRMGND

Cabinet GroundingCable Type: VD CABLE 16mm2 YL/GN

From: EARTH BAR To: Bay Ground Rail BarRow Bay Connector Row Bay

Kaf Elbatiekh

Cable List Grounding 1660 SM # 01

Part 2 02 page 14 Version 1.0 16-06-2015Part 2 02 page 14 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 48: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

202

A4 5

IN

OUT

6IN

OUT

3IN

OUT

4IN

OUT

1IN

OUT

2IN

OUT

10 ODF ... ODF 04 Rear 19 1660SM_.../SDH/02/14/6/OUT< >ODF_.../ODF/04/Rear/19

1660SM_.../SDH/02/14/5/OUT< >ODF_.../ODF/04/Rear/17

10 ODF ... ODF 04 Rear 20 1660SM_.../SDH/02/14//OUT< >ODF_.../ODF/04/Rear/20

18 1660SM_.../SDH/02/14/5/IN < >ODF_.../ODF/04/Rear/18

10 ODF ... ODF 04 Rear 17

10 ODF ... ODF 04 Rear

10 ODF ... ODF 04 Rear 15 1660SM_.../SDH/02/14/4/OUT< >ODF_.../ODF/04/Rear/15

1660SM_.../SDH/02/14/3/OUT< >ODF_.../ODF/04/Rear/13

10 ODF ... ODF 04 Rear 16 1660SM_.../SDH/02/14/4/OUT< >ODF_.../ODF/04/Rear/16

14 1660SM_.../SDH/02/14/3/OUT< >ODF_.../ODF/04/Rear/14

10 ODF ... ODF 04 Rear 13

10 ODF ... ODF 04 Rear

10 ODF ... ODF 04 Rear 11 1660SM_.../SDH/02/14/2/OUT< >ODF_.../ODF/04/Rear/11

1660SM_.../SDH/02/14/1/OUT< >ODF_.../ODF/04/Rear/9

10 ODF ... ODF 04 Rear 12 1660SM_.../SDH/02/14/2/IN < >ODF_.../ODF/04/Rear/12

10 1660SM_.../SDH/02/14/1/IN < >ODF_.../ODF/04/Rear/10

10 ODF ... ODF 04 Rear 9

10 ODF ... ODF 04 Rear

1660SM ... SDH 02

1660SM_.../SDH/02/33/4/OUT< >ODF_.../ODF/04/Rear/8

OUT 10 ODF ... ODF 044

IN 10 ODF ... 04

33

10 ODF

10

OUT

6

... ODF 04

ODF

1660SM_.../SDH/02/33/3/OUT< >ODF_.../ODF/04/Rear/6

5

Rear 7 1660SM_.../SDH/02/33/4/OUT< >ODF_.../ODF/04/Rear/7

1660SM_.../SDH/02/33/3/OUT< >ODF_.../ODF/04/Rear/5

8

Rear

Rear

IN 10 ODF

ODFOUT 10

1660SM_.../SDH/02/33/1/IN < >ODF_.../ODF/04/Rear/2

1660SM_.../SDH/02/33/1/OUT< >ODF_.../ODF/04/Rear/1

IN

BayName Row

ODF ODF

Label

Part

Kaf E

lbatiekh

ST

M-1 connections 1660S

M to O

DF

... ODF 04

From:

Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-Lucent - P

roprietary

x

Port

page15

1660 SM

# 01

2

Rear3

STM-1

To: ODF

OPTICAL JUMPER SM LC/SCS 10M/20

SideShelf

1660SM

Conn.

1660SM_.../SDH/02/33/2/OUT< >ODF_.../ODF/04/Rear/3

ODF...

4

The following connections are to be made using cabl e type:

Length [m]Slot Port

connections 1660SM to ODF

... ODF

ODF ... ODF

Rear04

Rear04

...1

2

10

04 Rear 1660SM_.../SDH/02/33/2/IN < >ODF_.../ODF/04/Rear/4

04 Rear

Name Row Bay Shelf

OUT 3

1

IN 10 ODF

Attention: Use the same label for both fibre ends

14... SDH 021660SM

11IN

OUT

12IN

OUT

9IN

OUT

10IN

OUT

7IN

OUT

8IN

OUT

OUT

10 ODF ... ODF 04 Rear 31 1660SM_.../SDH/02/14/12/OUT< >ODF_.../ODF/04/Rear/31

1660SM_.../SDH/02/14/11/OUT< >ODF_.../ODF/04/Rear/29

10 ODF ... ODF 04 Rear 32 1660SM_.../SDH/02/14/11/OUT< >ODF_.../ODF/04/Rear/32

30 1660SM_.../SDH/02/14/10/OUT< >ODF_.../ODF/04/Rear/30

10 ODF ... ODF 04 Rear 29

10 ODF ... ODF 04 Rear

10 ODF ... ODF 04 Rear 27 1660SM_.../SDH/02/14/10/OUT< >ODF_.../ODF/04/Rear/27

1660SM_.../SDH/02/14/9/OUT< >ODF_.../ODF/04/Rear/25

10 ODF ... ODF 04 Rear 28 1660SM_.../SDH/02/14/9/OUT< >ODF_.../ODF/04/Rear/28

26 1660SM_.../SDH/02/14/8/OUT< >ODF_.../ODF/04/Rear/26

10 ODF ... ODF 04 Rear 25

10 ODF ... ODF 04 Rear

10 ODF ... ODF 04 Rear 23 1660SM_.../SDH/02/14/8/OUT< >ODF_.../ODF/04/Rear/23

1660SM_.../SDH/02/14/7/OUT< >ODF_.../ODF/04/Rear/21

10 ODF ... ODF 04 Rear 24 1660SM_.../SDH/02/14//OUT< >ODF_.../ODF/04/Rear/24

22 1660SM_.../SDH/02/14//OUT< >ODF_.../ODF/04/Rear/22

10 ODF ... ODF 04 Rear 21

10 ODF ... ODF 04 Rear

10 ODF ... ODF 04 Rear 19 1660SM_.../SDH/02/14/6/OUT< >ODF_.../ODF/04/Rear/19

16-06-2015

1660 SM

# 01

Version

1.0

Page 49: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

202

A4

16

1660 SM

# 01

Use pursuant to com

pany Instructions - All R

ights Reserved

03 Rear 3 1660SM_.../SDH/02/17/4/OUT< >ODF_.../ODF/03/Rear/3

page

... SDH 02 17

Rear 4 1660SM_.../SDH/02/17/4/OUT< >ODF_.../ODF/03/Rear/4

OUT 10 ODF ... ODF

1 1660SM_.../SDH/02/17/3/OUT< >ODF_.../ODF/03/Rear/1

4IN 10 ODF ... ODF 03

10 ODF ... ODF 03 Rear

ODF 03 Rear 2 1660SM_.../SDH/02/17/3/OUT< >ODF_.../ODF/03/Rear/2

02 Rear 35 1660SM_.../SDH/02/17/2/OUT< >ODF_.../ODF/02/Rear/35

3IN 10 ODF ...

Rear 36 1660SM_.../SDH/02/17/2/IN < >ODF_.../ODF/02/Rear/36

OUT 10 ODF ... ODF

33 1660SM_.../SDH/02/17/1/OUT< >ODF_.../ODF/02/Rear/33

2IN 10 ODF ... ODF 02

34 1660SM_.../SDH/02/17/1/IN < >ODF_.../ODF/02/Rear/34

OUT 10 ODF ... ODF 02 Rear

10 ODF ... ODF 02 Rear1

IN

OUT

Bay Shelf SideConn. Length [m] Name Row

ODF

Name Row Bay Shelf Slot Port

OPTICAL JUMPER SM LC/SCS 10M/20

Part

1GbE

th connections 1660SM

to OD

F

x

Kaf E

lbatiekh

From: 1660SM

Port Label

Alcatel-Lucent - P

roprietary

To:

1660SM

1GbEth connections 1660SM to ODF

The following connections are to be made using cabl e type:

1660SM ... SDH 02 20

1

3

IN 10 ODF ... ODF 02 Rear 6 1660SM_.../SDH/02/20/1/IN < >ODF_.../ODF/02/Rear/6

OUT 10 ODF ... ODF 02 Rear 5 1660SM_.../SDH/02/20/1/OUT< >ODF_.../ODF/02/Rear/5

2IN 10 ODF ... ODF Rear 8 1660SM_.../SDH/02/20/2/IN < >ODF_.../ODF/02/Rear/8

OUT 10 ODF ... ODF

IN 10 ODF ...

02

02 Rear 7 1660SM_.../SDH/02/20/2/OUT< >ODF_.../ODF/02/Rear/7

02

ODF 02 Rear 10 1660SM_.../SDH/02/20/3/OUT< >ODF_.../ODF/02/Rear/10

9 1660SM_.../SDH/02/20/3/OUT< >ODF_.../ODF/02/Rear/9

4IN 10 ODF ... ODF

OUT

OUT 10 ODF ... ODF

Rear10 ODF ... ODF

02 Rear 11 1660SM_.../SDH/02/20/4/OUT< >ODF_.../ODF/02/Rear/11

02 Rear 12 1660SM_.../SDH/02/20/4/OUT< >ODF_.../ODF/02/Rear/12

Attention: Use the same label for both fibre ends

1660 SM

# 01

Version

1.016-06-2015

Page 50: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

202

A4 … … … 0

… … 0 TE LINE ODF … … …

Front 31 10 TE LINE ODF … …

Label

ODF ... ODF 01 7Front 32 10

Name Row Bay Półka Tray Conn.

1660SM_.../SDH/02/35/1/IN < >ODF_.../ODF/01/Front/5

34

Name Row Bay Shelf Direction Side Conn. Length [m]

STM16 connections ODF to TE LINE ODF

The following connections are to be made using cabl e type: Optical jumper FCsSCs0DB10M/28

From: ODF To: TE LINE ODF

Front 51

IN

Front

...10

1660SM_.../SDH/02/34/1/OUT< >ODF_.../ODF/01/Front/34

33 1660SM_.../SDH/02/34/1/IN < >ODF_.../ODF/01/Front/33... ODF 01

... ODFODF

page17

OUT 10 01 1660SM_.../SDH/02/35/1/OUT< >ODF_.../ODF/01/Front/66

01

1660 SM

# 01

Front

01

IN 10 ODF

1660SM ... SDH 02 35ODF

... ODF 01

OUT 10 ODF ... ODF1660SM ... SDH 02 34 1

OUT 10 Front

ODF 01 Front 3 1660SM_.../SDH/02/33/1/IN < >ODF_.../ODF/01/Front/3

Front

4 1660SM_.../SDH/02/33/1/OUT< >ODF_.../ODF/01/Front/4

01 Front

...

1660SM_.../SDH/02/34/1/OUT< >ODF_.../ODF/01/Front/7

01 Front 1660SM_.../SDH/02/34/1/IN < >ODF_.../ODF/01/Front/7ODF

1660SM ... SDH 02 33

OUT 10 ODF ... ODF

1IN 10 ...

ODF

1660SM ... SDH 02 34 IN 10 ODF

4

OUT 10 ODF ... ODF 01 Front 1660SM_.../SDH/02/25/1/OUT< >ODF_.../ODF/01/Front/3

IN 10 ODF 01 Front 1660SM_.../SDH/02/25/1/IN < >ODF_.../ODF/01/Front/33...

Port/Direction Label

1660SM ... SDH 02 25 1

Length [m] Name Row Bay Shelf Side

1660SM To: ODF

Name Row Bay Shelf Slot Port Conn.

ODF

1

connections 1660SM to ODF

The following connections are to be made using cabl e type: OPTICAL JUMPER SM LC/SCS 10M/20

Part

ST

M-64 connections 1660S

M to O

DF

Kaf E

lbatiekh

From:

7

8

x Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-Lucent - P

roprietary

STM-64

ODF

ODF

Attention: Use the same label for both fibre ends

16-06-20151.0

1660 SM

# 01

Version

Page 51: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

202

A4

Slot Port Length [m]

DDF ... …

Slot

... SDH 02 11

Row Bay/Tray

S2 ... .../...

ShelfTermination

blockPort

Aux. Channels connections

Cable:

...

NameRow

Length [m] Name

Name

PortBay Shelf

... … 1660SM_.../SDH/02/12/C2< >DDF_.../.../.../.../…

Label

1660SM_.../SDH/02/11/S2< >DDF_.../.../.../.../…

Slot Port

Cable:

C2

Port

12

1660SM

15

...

Block

Bay

3AL18034CNAA - CLEE 2 Q HF HE5-15MC/15M

1660SM To: FAN SHELF

3AL17956HLAA - DF CORD 4Q HF HE5-15M-C 25 M

DDF

Label

1AB200480001 - DF CORD 33P HF HE5-50M 25 M

Termination block

Port Label

VDS - Aux. Channels connections

1660SM

Part

Kaf E

lbatiekh

From:

Row

From:

Name Row Bay

Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-Lucent - P

roprietary

18

x

1660 SM

# 01

Port

Row Bay/Tray

From:

SlotRow

Name

1660SM ...

... SDH ... .../...

Length [m]Name

Slot

1660SM

Row Bay Shelf

02

03 05 1

Name Connector

…IN

Row BayLength [m]

SDH

External connections of 1660S

M

page

Name

1660SM

Cable:

From:

Aux. Channels connections

Cable: 1AB200670004 - CLER ALA HE5-9M 25 M

Housekeeping - Aux. Channels connections

1660SM_.../SDH/03//IN< >ALARM TRU_…/…/05/1ALARM TRU …

Bay Shelf

1660SM

Label

For more details about Aux. plug pin-out see Append ix B, C

Slot

…1660SM_.../SDH/03/10/C2< >FAN SHELF_A/1/…/M2-M3

03SDHC4

NameRow

C2 1,5 FAN SHELF

Port

M2-M3

Bay Shelf Bay

Row Bay

1.016-06-2015

1660 SM

# 01

... 10

Row Bay

Version

Cable:

Shelf Slot Port

To: TRU 6/6

Port

From: 1660SM

Name

Slot

1660SM

Row

Attention: Use the same label for both cable ends

Length [m]Name

Aux. Channels connections

1AB200460001 - CLEE 5P HE5-9M/9F

Label

A 1

01 Pos.1

Shelf Port

10 C3 RACK ALARM

Length [m] Name Label

1660SM ... SDH 02 1660SM_.../SDH/02/10/C3< >RACK ALARM_…/02/01/Pos.1… 02

Page 52: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

202

A4

1660SM_.../SDH/02/11/J3< >DDF_.../.../.../.../…DDF ... .../...

Synchronization for 1660S

M

page

Name

1660SM

Bay Shelf

... …

Name PortTermination

block

1660 SM

# 01

Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-Lucent - P

roprietary

19

x

Part

Kaf E

lbatiekh

From:

Row

1660SM

Aux. Channels connections

From: 1660SM

1660SM

...

Row Bay/TrayLength [m] Label

1102

...

J3

J4

Slot Port

I/O 2 MHz Synchronous interfaces -CLER 4P HF 1.0/2. 3 BAL 25 m - 1AB200560001

1660SM_.../SDH/02/11/J7< >DDF_.../.../.../.../…... .../... ... …

1660SM_.../SDH/02/11/J4< >DDF_.../.../.../.../…...

SDH...

DDF

... .../...... DDF

J7

J8

J7

J8

J5

J6

... DDF ... .../... ... … 1660SM_.../SDH/02/11/J8< >DDF_.../.../.../.../…

XX YY 1660SM_.../SDH/02/11/J5< >_XX/YY//

XX YY 1660SM_.../SDH/02/11/J6< >_XX/YY//

XX YY 1660SM_.../SDH/02/11/J7< >_XX/YY//

XX YY 1660SM_.../SDH/02/11/J8< >_XX/YY//

Name Row Bay RU Slot Port Length [m] Name

For more details about Aux. plug pin-out see Append ix D, E

Label

AUX

Row Bay Panel Port

... SDH 02 11 XX YY 1660SM_.../SDH/02/11/AUX< >_XX/YY//

Attention: Use the same label for both cable ends

1660 SM

# 01

Version

1.016-06-2015

Page 53: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

202

A4

SDH... 02

... SDH

FAN SHELF ... SDH

To: EQUIPMENT

...

TRU

Bay Shelf Port Slot

1660SM

Row Bay

1660SM_.../SDH/02/10/HK< >FAN SHELF_.../SDH//N3HK N3

Kaf E

lbatiekh

1660SM

Telephone handset connectiona

The following connections are to be made using cabl e type:

Row Length [m]

Connection 1660SM to OfficeAlarmBay

Name Name LabelPort

From:

Slot

Use pursuant to com

pany Instructions - All R

ights Reserved

Alcatel-Lucent - P

roprietary

20

x

Part

External connections of 1660S

M1660 S

M # 01

page

1660SM

1660SM_.../SDH/02/10/RACK< >TRU_.../SDH//M2

Q2 FAN SHELF

... SDH M2RACK

1660SM_.../SDH/02/10/Q2< >FAN SHELF_.../SDH//N3

10b2 IN

... SDH N3

1660SM_.../SDH/02/10/10b2 IN< >_///

10b2 OUT

10bT

HK02 1660SM_.../SDH/02/12/HK< >_///

_////< >_///

_////< >_///

10

1660SM_.../SDH/02/10/10bT< >_///

1660SM_.../SDH/02/10/10b2 OUT< >_///

12

3EC 40591 AA--

_////< >_///

To: EXTENXION ALARM UNIT

Name Row Bay Shelf Slot Port Length [m] Name Row Bay Slot Port

11 PJ777 Phone1660SM ... SDH 02

NOTE : ESPAL CABLE IS PROVIDED TOGETHER WITH TRU

FOR MORE DETAILS ABOUT PLUGS PIN-OUT SEE APPENDIX B

SDH 1660SM_.../SDH/02/11/PJ777< >Phone_.../SDH/

Label

The following connections are to be made using cabl e type: 3AL18034CNAA - CLEE 2 Q HF HE5-15MC/15M, ALARM CORD 3AL34964AAAA part of fit 3AL91653AAAA

16-06-2015

Attention: Use the same label for both cable ends

1660 SM

# 01

Version

1.0

NOTE : ESPAL CABLE IS PROVIDED TOGETHER WITH TRU

Connection Extension Alarm Unit to Equipment

From: EXTENSION ALARM UNIT To: EQUIPMENT

Name Row Bay RU Slot Port Length [m] Name

M2 FAN SHELF

LabelCableRow Bay Slot Port

M3 1660

EXT ALM/.../SDH/M2< >FAN SHELF/.../SDH/1/M1... SDH 1 M1

M4

EXT ALM/.../SDH/M3< >1660/.../SDH/10/RACK LAMP... SDH 10 RACK LAMP

M5

...

...

M7

...M6

SDH 4 N/A

3AL 79457 AAAA

...

...

M8

EXT ALM ...

Page 54: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

"HK" connector C2 mounted on the “Control and Gener al I/F unit (CONGI)” (slot 10 and 12.)

"RACK" connector C3 mounted on the “Control and Gen eral I/F unit (CONGI)” (slot 10).

Kaf Elbatiekh

Appendix A 1660 SM # 01

Part 2 02 page 21 Version 1.0

"Q2" connector C4 mounted on the “Control and Gener al I/F unit (CONGI)”.(slot 10)

16-06-2015Part 2 02 page 21 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 55: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

G.703, RS 232 and V11 Aux. Channels connections

Kaf Elbatiekh

Appendix B 1660 SM # 01

Part 2 02 page 22 Version 1.0 16-06-2015Part 2 02 page 22 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015

Page 56: Iodm Kaf Elbatiekh 1830pss32 1660sm v1.0

G.703, RS 232 and V11 Aux. Channels connections

Kaf Elbatiekh

Appendix C 1660 SM # 01

Part 2 02 page 23 Version 1.0 16-06-2015 Part 2 02 page 23 Version 1.0

Alcatel-Lucent - ProprietaryUse pursuant to company Instructions - All Rights Reserved

A4

16-06-2015