ip100 test report 021118 - ic plus test report_021118.pdf · ic plus corp....
TRANSCRIPT
IC PLUS CORP. 九暘電子股份有限公司
-1-
IP100 Test Report Date:2002-Nov-18
Summary
ItemNo.
Description Test
Result Page Note
Basic Function Test 3 1.1 Test Environment 1.2.1 EEPROM Function Test
1. EEPROM Read / Write PASS
3
1.2.2 LED Display Test 1. 10/100 Speed LED 2. Link / Activity LED 3. Full / Half LED
PASS
3
1.2.3 NWAY Auto-negotiation Test 1. 10 Half Duplex Link Check 2. 10 Full Duplex Link Check 3. 100 Half Duplex Link Check 4. 100 Full Duplex Link Check
PASS 4
1.2.4 Force Mode Test (Disable Auto-negotiation) 1. 10 Half Duplex Link Check 2. 10 Full Duplex Link Check 3. 100 Half Duplex Link Check 4. 100 Full Duplex Link Check
PASS 4
1.2.5 Register Read/ Write Test 1. PCI Register R/ W 2. NIC CSR Register R/ W 3. MII Register R/ W
PASS
4
1.2.6 Internal Loop Back Test PASS 5
1.
1.2.7 External Loop Back Test 1.2.7.1 UTP Loop Back 1.2.7.2 Fiber Loop Back
PASS PASS
5
2. Ping-Pong Function Test Chain mode run 12 hours
PASS
6
3. Novell Lantest PASS 7 4. Novell Endurance Test
Chain mode run 24 hours PASS
8
5. Novell CC Test Chain mode run 24 hours
PASS
9
IC PLUS CORP. 九暘電子股份有限公司
-2-
ItemNo.
Description Test
Result Page Note
6. Novell Performance 3 Test PASS 10 7. Microsoft Hardware Compatibility Test
(Driver Test) 1. Win2000 HCT (100F) 2. Win-ME HCT (100F)
7.1 Environment Setup 7.2 Test Result 7.3 Plug and Play Test
PASS
11
Compatibility Test 8.1 Switch (PHY) Compatibility Test
1. D-Link des-1008D 2. Kendin switch 3. IP178A 4. Altima 5. IP175
PASS PASS PASS PASS PASS
13
8.
8.2 Smartbits 7410B Compatibility Test 1. Smartbits
PASS 15
9. Link Reliability Test 9.1 Plug & Unplug Test 9.2 Power On/ Off Test
PASS 16
10. IEEE 802.3 TX Pattern Test PASS 17 11. Wake ON LAN PASS 26 12. Boot Rom Test PASS 26 13. EMI Test PASS 26
IC PLUS CORP. 九暘電子股份有限公司
-3-
1. Basic Function Test
1.1 Test Environment Software Test Program: BGO.EXE (Version: 12/17/2001, file size: 182,758) OS: DOS 6.22 or Pure Win98 DOS Hardware Equipment Model Speed PC * 1 ASUS P2B-F PII-BX 450 LAN Card * 2 Realtek 8139C, IP100 NIC 10/100 Mbps
1.2 Test Condition & Test Result 1.2.1 EEPROM Function Test Setup: EEPROM Read / Write Timing conformance Subject: Make sure EEPROM read/write function is ok.
Test Result: PASS
1.2.2 LED Display Test Setup: 10/100 Speed LED Link / Activity LED Full / Half duplex LED Subject: Make sure led indication is normal in different operation mode.
Test Result: PASS Condition Result Note 1 No link PASS 2 100M Full PASS 3 100M Half PASS 4 10M Full PASS 5 10M Half PASS
IC PLUS CORP. 九暘電子股份有限公司
-4-
1.2.3 NWAY Auto-negotiation Test Setup: 10 Half Duplex Link Check 10 Full Duplex Link Check 100 Half Duplex Link Check 100 Full Duplex Link Check Subject: Force NIC in different operation mode and check link status.
Test Result: PASS Condition Result Note 1 100M Full PASS 2 100M Half PASS 3 10M Full PASS 4 10M Half PASS
1.2.4 Force Mode Test (Disable Auto-negotiation) Setup: 10 Half Duplex Link Check 10 Full Duplex Link Check 100 Half Duplex Link Check 100 Full Duplex Link Check Subject: Force NIC in different operation mode and check link status.
Test Result: PASS Condition Result Note 1 100M Full PASS IP100 LED will indicate 100Full, but
RLT8139C will be in 100 Half 2 100M half PASS 3 10M full PASS IP100 LED will indicate 10Full, but
RLT8139C will be in 10 Half 4 10M half PASS
1.2.5 Register R/W Test Setup: PCI Register Read / Write NIC CSR Register Read / Write MII Register R/ W Subject: Verify Read / Write PCI and CSR register.
Test Result: PASS Condition Result Note 1 PCI register Read/Write PASS 2 NIC CSR register Read / Write PASS 3 MII register Read / Write PASS
IC PLUS CORP. 九暘電子股份有限公司
-5-
1.2.6 Internal Loop Back Test Setup: 1. Chain mode run for 4 hours Subject: Run internal loop back test in chain mode.
Test Result: PASS Condition Result Note 1 4 hours PASS No Packet Loss
1.2.7 External Loop Back Test 1.2.7.1 UTP External Loop back Test Setup: Use RJ45 connector to connect TX to RX. Chain mode run for 4 hours Subject: Run external loop back test in chain mode.
Test Result: PASS Condition Result Note 1 4 hours PASS No Packet Loss 1.2.7.2 Fiber External Loop Back Test Setup: Use a fiber to connect TX to RX. Chain mode ran overnight test Subject: Run external loop back test in chain mode.
Test Result: PASS Condition Result Note 1 Approximately 10 hours PASS
IC PLUS CORP. 九暘電子股份有限公司
-6-
2. Ping-Pong Function Test
2.1 Test Environment Server/ Client No. LAN card Mother Board CPU RAM Cable
Length
Server IP100 ASUS - TUSL2-C Intel
Celeron 1GHz
128M 120m
Client 1 IP100 ASUS – TUSL2-C Intel
Celeron 1GHz
128M 120m
Test Program: BGO.EXE (Version: 12/17/2001, file size: 182,758) OS: DOS 6.22 or Pure Win98 DOS
Client Server
cross over UTP
2.2 Test Result PASS
Server/ Client
Speed/ Duplex Testing Time Result Note
Server 100M Full 12 hours PASS No Packet Loss Client 100M Full 12 hours PASS No Packet Loss
Server/ Client
Speed/ Duplex Testing Time Result Note
Server 10M Half 4 hours PASS No Packet Loss Client 10M Half 4 hours PASS No Packet Loss
IC PLUS CORP. 九暘電子股份有限公司
-7-
3. Novell Lantest
3.1 Test Environment Server/ Client No. NIC card Mother
Board CPU RAM Cable Length
Server1 IP100 X2
GigaBYTE GA-7ZX
AMD athlon 1.1 G 128M 3m
Server2 Realtek 8139D
X2 Asus TUSL2-C Celeron 1G 128M 3m
Client Realtek 8139D A-Open AX4B P4 1.6G 256M 3m
HUB: D-Link DE-808TP Driver version: 2.0.0 Filename: st201.lan
Test Configuration
Network BServer 2 Server 1 Client
OS: Netware 5X OS: Netware 6X OS: Windows 2000
Hub 10Mbps
Network A Network A Network A
Device under test
Novell LANTest
NIC 1 NIC 1
NIC 2NIC 2
Prot 1 Port 2 Port 3
NIC
3.2 Test Result
PASS
Server/ Client Result Note
Server1, Server2 PASS
Client PASS
IC PLUS CORP. 九暘電子股份有限公司
-8-
4. Novell Endurance Test
4.1 Test Environment Server/ Client No. LAN card Mother Board CPU RAM Cable
Length Server IP100 Asus P4B P4 1.6G 128M 3m
Client 1 Intel Giga NIC 82543GC
Asus P4T/Wol/WOA P4 1.5G Rambus 128M
3m
2 Intel Giga NIC 82543GC MSI K7N420 AMD Atholon
1G 128M 3m
3 Intel Giga NIC 82543GC AOPEN AK77-PRO AMD
Atholon 1G 128M 3m
4 Intel Giga NIC 82543GC
ASUS TUV4X/533/WOA/ Celeron 1.3G 128M 3m
5 Intel Giga NIC 82543GC
ASUS A7M266/550/WOL/
AMD Atholon 1G 128M 3m
6 Intel Giga NIC 82543GC Asus TUSL2-C Celeron 1G 128M 3m
7 Intel Giga NIC 82543GC
Asus TUSL2-C Celeron 1G 128M 3m
Switch: D-Link DES-1008D Driver version: 2.0.0 Filename: st201.lan
Client 1
Client 2
Client 3
Client 4
Client 5
Server
Switch
4.2 Test Result
PASS
Server/Client No. Speed/ Duplex Testing Time Result Note Server 100M Full 24 hours PASS No Error Client 1 100M Full 24 hours PASS No Error
2 100M Full 24 hours PASS No Error 3 100M Full 24 hours PASS No Error 4 100M Full 24 hours PASS No Error 5 100M Full 24 hours PASS No Error 6 100M Full 24 hours PASS No Error 7 100M Full 24 hours PASS No Error
IC PLUS CORP. 九暘電子股份有限公司
-9-
5. Novell Copy & Compare Test
5.1 Test Environment Server/ Client No. LAN card Mother Board CPU RAM Cable
Length Server IP100 Asus TUSL2-C Celeron 1G 128M 3m Client 1 IP100 A-Open AX4B P4 1.6G 256M 3m
Driver version: 2.0.0 Filename: st201.lan
Client Server
cross over UTP
5.2 Test Result PASS
Server/ Client
Speed/ Duplex Testing Time Result Note
Server 100M Full 24hours PASS No Failure Client 100M Full 24hours PASS No Failure
IC PLUS CORP. 九暘電子股份有限公司
-10-
6. Novell Performance 3 Test
6.1 Test Environment Server/ Client No. NIC card Mother Board CPU RAM Cable
Length Server IP100
Asus P4B P4 1.6G 128M 3m
Client 1 Intel Giga NIC 82543GC Asus P4T/Wol/WOA P4 1.5G Rambus
128M 3m
2 Intel Giga NIC 82543GC MSI K7N420 AMD
Atholon 1G 128M 3m
3 Intel Giga NIC 82543GC AOPEN AK77-PRO AMD
Atholon 1G 128M 3m
4 Intel Giga NIC 82543GC
ASUS TUV4X/533/WOA/
Celeron 1.3G
128M 3m
5 Intel Giga NIC 82543GC
ASUS A7M266/550/WOL/
AMD Atholon 1G 128M 3m
6 Intel Giga NIC 82543GC Asus TUSL2-C Celeron
1G 128M 3m
7 Intel Giga NIC 82543GC Asus TUSL2-C Celeron
1G 128M 3m
Switch: D-Link DES-1008D Driver version: 2.0.0 Filename: st201.lan
Client 1
Client 2
Client 3
Client 4
Client 5
Server
Switch
6.2 Test Result PASS
Server Speed/ Duplex
Maximum (K bytes)
Average (K bytes) Note
IP100 100M Full 11387.98 11344.78
IC PLUS CORP. 九暘電子股份有限公司
-11-
7. Microsoft Hardware Compatible Test (HCT)
7.1 Test Environment Server/ Client NIC card Mother Board CPU RAM Cable
Length Support device 3 IP100 Server Ethernet card 2 Dlink530
MSI-MS 6398 Intel P4 1.6G 128M 2m
Test device 1 IP100 Support device 2 IP100 Client Ethernet card 1 Dlink530
ASUS-P4B266
Intel P4 1.6G 128M 3m
OS: Win2000/ Win-Me Driver version 2.5.4.0 LAN cards work at 100M full duplex. Switch: Accton 3008A Switch Domain 1 (test domain): test device 1, support device 2, and support device 3. Domain 2: Ethernet card 1 and Ethernet card 2
IC PLUS CORP. 九暘電子股份有限公司
-12-
7.2 Test Result 7.2.1 Win2000 HCT-100M full duplex Test Condition: OS: Win2000 Driver version 2.5.4.0 LAN cards work at 100M full duplex. Test Result: PASS
No. Test item Result Note 1 NDIS Functional Testing PASS 2 NDIS Performance Testing PASS 3 NDIS Stress Testing PASS
7.2.2 Win-Me HCT-100M full duplex Test Condition: OS: Win2000 Driver version 2.5.4.0 LAN cards work at 100M full duplex. Test Result: PASS
No. Test item Result Note 1 NDIS Functional Testing PASS 2 NDIS Performance Testing PASS 3 NDIS Stress Testing PASS
7.3 Plug and Play Test
Test Condition: Test whether IP100 will automatically setup under all Microsoft Windows
Test Results No. OS Result Note 1 Windows 95 No Plug and Play 2 Windows 98 No Plug and Play 3 Windows Me No Plug and Play 4 Windows 2000 Plug and Play Driver is
Sundance 1.05 5 Windows XP Plug and Play Driver is
Sundance 1.05
IC PLUS CORP. 九暘電子股份有限公司
-13-
8. Compatibility Test
8.1 Switch (PHY) Compatibility Test 8.1.1 Test Environment
Master / Slave No. NIC card Mother Board CPU RAM Cable
Length
Master 0 SX-7410B Smartbits 2000
Slave IP100 ASUS - TUSL2-C
Intel Celeron 1GHz 128M
1 Kendin Switch 130m~2m
2 Marvell Switch 130m~2m
3 IC+ 178A 130m~2m
4 D-Link Des1008D 130m~2m
Switch
5 IC+ 175 130m~2m
Software: 1. Client: BGO/ Rx Tx test, 2. Server: Smart window 7.00.26
Test Criteria: 1.Server: Smartbits send 1,000,000 packets (random data,
random length) to Switch. 2. Client: Receive packets from switch, make sure no packet loss
Master Slave
Switch
IC PLUS CORP. 九暘電子股份有限公司
-14-
8.1.2 Test Result PASS
Switch Note Cable length
Kendin 5p Switch
Marvell 5p Switch
IC+ IP178A
D-Link Des1008D
IC+ IP 175
130m PASS PASS PASS PASS PASS 120m PASS PASS PASS PASS PASS 110m PASS PASS PASS PASS PASS 100m PASS PASS PASS PASS PASS 90m PASS PASS PASS PASS PASS 80m PASS PASS PASS PASS PASS 70m PASS PASS PASS PASS PASS 60m PASS PASS PASS PASS PASS 50m PASS PASS PASS PASS PASS 40m PASS PASS PASS PASS PASS 30m PASS PASS PASS PASS PASS 20m PASS PASS PASS PASS PASS 10m PASS PASS PASS PASS PASS 2m PASS PASS PASS PASS PASS
IC PLUS CORP. 九暘電子股份有限公司
-15-
8.2 Smartbits 7410B Compatibility Test 8.2.1 Test Environment
Master / Slave No. NIC card Mother Board CPU RAM Cable
Length
Master 0 IP100 ASUS K7V AMD K7 - 800MHz 512M
Smartbits 7410B 130m~0m Software: BGO/ Ping Pong test Smartbits: set to be echo mode Test Criteria: Rx 10,000,000 packets, no packet loss
Master
Smartbits7410B
cross over UTP
8.2.2 Test Result PASS
Cable length
Smart bit 7410B Note
130m PASS No Packet Loss 120m PASS No Packet Loss 110m PASS No Packet Loss 100m PASS No Packet Loss 90m PASS No Packet Loss 80m PASS No Packet Loss 70m PASS No Packet Loss 60m PASS No Packet Loss 50m PASS No Packet Loss 40m PASS No Packet Loss 30m PASS No Packet Loss 20m PASS No Packet Loss 10m PASS No Packet Loss 2m PASS No Packet Loss
IC PLUS CORP. 九暘電子股份有限公司
-16-
9. Link Reliability Test 9.1 Plug / Unplug test
9.1.1 Test Environment
IP100
D-LinkDES-1008D
switchRelay
UTP UTP
( Relay on/off automatically )
Test Time: over night Test Criteria: Link is ok if relay is on.
9.1.2 Test Result
PASS
9.2 Power On / Off Test 9.2.1 Test Environment
IP100
D-LinkDES-1008D
switchUTP
( power on /off )
Test Criteria: Link is ok after switch power on/ off 100 times
9.2.2 Test Result
PASS
IC PLUS CORP. 九暘電子股份有限公司
-17-
10. IEEE 802.3 Transmit Pattern Test
10.1 100BASE-T Test Result
Measured Item Specification Measured Value Measured Result
(1) Transmit Eye Diagram With Waveform Limit With Waveform Limit PASS (2) Transmit Jitter < 1.4 ns 440 ps PASS (3) Differential Output
Voltage (+ Vout) 0.95V~1.05V + 960mv PASS
(4) Differential Output Voltage (- Vout) 0.95V~1.05V - 960mv PASS
(5) Rise and Fall Times [0]~[1] 3~5 ns 3.797ns~4.201ns PASS
(6) Rise and Fall Times [1]~[0] 3~5 ns 3.951ns~4.593ns PASS
10.2 10BASE-T Test Result
Measure Item Specification Measure Value Measure Result
(1) Idle Pulse Waveform Within Waveform limit With Waveform Limit PASS (2) Idle Pulse Waveform with
100m UTP3 cable Within Waveform limit With Waveform Limit PASS
(3) Link Pulse Waveform Within Waveform limit With Waveform Limit PASS (4) Link Pulse Waveform with
100m UTP3 cable Within Waveform limit With Waveform Limit PASS
(5) Transmit Waveform Jitter < + / - 8ns 3 ns PASS (6) Transmit Waveform Jitter
with100m UTP3 cable < + / - 8ns 5 ns PASS
(7) Transmit Waveform with 100m UTP3 cable Within Waveform limit Within Waveform limit PASS
(8) Peak Differential Output Voltage (50 ns data packet)
2.2~2.8 V 2.26 V PASS
(9) Peak Differential Output Voltage (100 ns data packet)
2.2~2.8 V 2.26 V PASS
IC PLUS CORP. 九暘電子股份有限公司
-18-
10.3 Measured Waveform: 10.3.1 100Base-T:
(1) Transmit Eye Diagram:
(2) Transmit Jitter:
IC PLUS CORP. 九暘電子股份有限公司
-19-
(3) Differential Output Voltage (+Vout):
(4) Differential Output Voltage (-Vout):
IC PLUS CORP. 九暘電子股份有限公司
-20-
(5) Rise and Fall Times ([0]~[1]):
(6) Rise and Fall Times ([0]~[-1]):
IC PLUS CORP. 九暘電子股份有限公司
-21-
10.3.2 10 Base-T: (1) Idle Pulse Waveform:
(2) Idle Pulse Waveform With 100m UTP3 Cable:
IC PLUS CORP. 九暘電子股份有限公司
-23-
(5) Transmit Waveform Jitter:
(6) Transmit Waveform Jitter With 100m UTP3 Cable:
IC PLUS CORP. 九暘電子股份有限公司
-24-
(7) Transmit Waveform With 100m UTP3 Cable:
(8) Peak Differential Output Voltage (50ns)