irreversible quazar ipl
TRANSCRIPT
IPL800 Accessory
Keep this manual in a convenient place for quick and easy
reference at all tim
es.
The product n
ames in
this g
uidebook are tra
demarks o
r regis-
tered tra
de m
arks o
f each sp
ecific m
anufactu
rer. In
the in
terest
of p
roviding su
perio
r equipment, Q
uazar In
dustrie
s reserves th
e
right to
modify
or a
mend equipment sp
ecifica
tions w
ithout n
otice
or o
blig
atio
n.
22 2200 0000 0099 99 QQ QQuu uuaa aazz zzaa aarr rr II II nn nn
dd dduu uuss sstt tt rr rr ii ii ee ee
ss ss LL LLtt tt dd dd.. ..
Quick Setup Guide
Read this guidebook firs
t to set up your
equipment fo
r use.
Instru
ction Material fo
r Quazar IP
L800
Instru
ction Material fo
r Quazar IP
L800
Instru
ction Material fo
r Quazar IP
L800
Instru
ction Material fo
r Quazar IP
L800
Add On Feature to LD80K
Add On Feature to LD80K
Add On Feature to LD80K
Add On Feature to LD80K
Quazar
IPL and Driver
Replacement P
arts
IPL Supplies
IPL Eyewear
Eyewear #
D-213-4600 Each $199.95
IPL360 Lamp Replacement
IPL # D-213-6700 Each $299.95
Carbon Dye 200ml
Carbon Dye # P-213-2500 Each $99.95
Price
s are su
bject to
change with
out n
otifica
tion. T
o order o
n-lin
e, g
o to
http
://www.centre-biotechnique-avance.com
For te
chnica
l assista
nce beyond what th
is manual p
rovides, p
lease e-m
ail
Please allow 24 hours fo
r processin
g.
Quazar IPL produces la
ser ra
diatio
n w
hich can be harm
ful to
the eyes. A
lways w
ear p
rotectiv
e eyewear w
hile
operatin
g this equipment.
Intense Pulsed Light has the capability
to burn the skin if the technician does not
closely observe th
e patie
nt’s re
actio
n to
the procedure. IP
L tre
atm
ents re
sult in
full d
estru
ctio
n of th
e hair fo
llicle
and is irreversible. A
lways plan ahead before underta
king detail w
ork such as eyebrow shaping or h
airlin
e con-
tourin
g. P
atch te
st a
small a
rea (n
o la
rger th
an 1X1 in
ch square) b
efore fu
ll applicatio
n. A
llow 24 hours to
deter-
mine th
e patie
nt’s re
actio
n before applying fu
ll treatm
ent.
Handlin
g Precautio
ns: The IP
L flash tu
be ca
n be damaged beyond re
pair if th
e handpiece is
dropped or b
umped sh
arply. H
andle with
care.
UL
85
29
00
1
Prin
ted in
UK
IPL800 Instrument
The IP
L800 co
mes w
ith a 220jcm
2 adjusta
ble pulse
frequency (fix
ed pulse
duratio
n) in
strument
for su
perio
r operator contro
l. D
ropping or b
umping th
e instru
ment m
ay re
sult
in irre
versib
le
damage to
the in
ternal co
mponents a
nd w
ould not b
e co
vered by w
arra
nty. A
ctivatin
g th
e IP
L while th
e glass co
ndenser is in
contact w
ith an object (su
ch as th
e ca
rbon te
st sheet) m
ay dam-
age th
e optics. W
hen te
sting against th
e ca
rbon sh
eet a
lways h
old th
e co
ndenser a
t least 5
mm
from th
e su
rface.
Trouble Shootin
g
Should you en
counter tech
nica
l problem
s with
your Q
uazar IP
L syste
m, re
fer to
the fo
llowing guide fo
r poten
tial p
roblem
s and th
eir solution
s. —Unit is
plugged in
to th
e wall, a
ll accessorie
s are correctly
inserted in
to th
e unit
but n
o laser output is
being registered.
++Check all c
onnectio
ns. P
lug and unplug each one being sure all c
ontacts are sound.
++Check all c
ords. D
ue to
contin
ual b
ending and fa
tigue, w
ires m
ay fra
y or b
reak re
sult-
ing is fu
ll loss of p
ower.
++Check Fuse: T
he Quazar u
nit h
as a fa
st-a
ctin
g fu
se m
ounted on th
e to
p panel o
f your
unit
to protect the delicate flash tube fro
m volta
ge spikes, on-lin
e power surges and
electro
-static discharge (ESD damage).
Replace with
15 amp fast actin
g type only.
Failure to
comply with
these specific
atio
ns m
ay re
sult in
serio
us damage to
your IP
L and
will v
oid all w
arra
ntie
s.
—Unit h
ums or m
akes noises.
++Unit n
eeds servicing.
—IPL output is
weak.
++Emitte
r optic is blocked with
carbonized debris (b
urnt h
air e
tc.). C
lean th
oroughly with
a cotto
n tip
ped applicator a
nd alcohol. If th
e perfo
rmance of th
e IP
L does not im
prove
afte
r cleaning th
e head your u
nit n
eeds servicing by a qualifie
d agent. C
ontact te
chnical
support fo
r assistance.
—No output from the IPL is registered afte
r all trouble-shootin
g suggestio
ns
listed above have been checked.
++Probable fla
sh tu
be fa
ilure. U
nit n
eeds servicing.
Digita
l Temperature Meter
The m
eter m
ay need re
-calibratio
n by adjustin
g th
e on-board potentio
meter. T
wo re
sistors,
Ra and Rb m
ay be used in
order to
alte
r the fu
ll scale re
ading (F.S
.R.) o
f the m
eter.
10
Specific
atio
n
Min
Typ.
Max.
Unit
Reading
Accu
racy
0.05
0.1
%(+
1 co
unt)
50
Linearity
+1
count
40
Sample ra
te
3
Samples/se
c 30
Op. te
mp
0
50
˚C
20
Temp. S
tbl.
150
Ppm/˚C
10
28.9
Hair Removal w
ith Light
The newest p
rocedure to
reach th
e epilatio
n co
smetology m
arket is ca
lled In
tense Pulse
d Lig
ht. It's
a re
volutio
nary advancement to
'laser' co
smetology (w
hich
inclu
des h
air re
moval a
nd m
ore) a
nd is
similar to
laser e
pilatio
n in
many w
ays. T
he ra
diatio
n emissio
n so
urce
; however, is fa
r superio
r in
cost, re
liability
, fluence (p
ower) a
nd adjusta
bility
. A very powerfu
l flash tu
be delivers a
photon emissio
n 10-20 tim
es la
rger th
an a ty
pica
l epilatio
n
laser (in
diameter a
t 120-180 jcm
2). T
his lig
ht e
nergy is ca
refully filte
red with
precisio
n optics. T
he
heat is re
moved fro
m th
e energy w
ith a S
chott K
G1 Filte
r, then all w
avelengths a
bove 800 are
removed with
a MgF2
coated le
ns.
The photons are sent through Ruby, Sapphire
or a BK7 Glass
con-
denser (d
epending on re
quire
ments). T
he end re
sult is a
safe, u
sable,
high-density
photon emissio
n with
perfo
rmance equal to
(or greater
than) th
at o
f an ordinary la
ser.
Power Compariso
n: Standard laser epilators
produce CW or Pulse
d
output p
ower a
round 20-60 W
atts. A
n IP
L typica
lly produces 3
00-600
Watts.
This
allows
for a much larger tre
atm
ent diameter,
which
equates to
far g
reater sp
eed and efficie
ncy fo
r the te
chnicia
n.
One of th
e greatest b
enefits o
f the IP
L, over th
at o
f the la
ser, is th
e
diffe
rence in
cost. T
he ty
pica
l 'price
per w
att' o
f a sta
ndard la
ser is
$1,000-$2,000 w
hereas th
e price
per w
att o
f an IP
L is roughly $
100-
$200.
Average life
expecta
ncy of th
e fla
sh tu
be is o
ver o
ne m
illion pulse
s. This e
quates to
3-5 years o
f reliable se
rvice
, nearly
the sa
me as a
Long
Pulse
Diode. T
he fla
sh tu
be is e
asily
service
able w
hen it co
mes tim
e
for re
placement a
nd co
sts around $300-$500 (d
epending on unit).
The B
enefits o
f IPL o
ver La
ser: La
rger a
reas ca
n be tre
ated at o
ne
time. A
typica
l man's b
ack w
ould re
quire
about 2
0-30 m
inutes w
ith a Lo
ng Pulse
Diode. T
he
IPL320 would do th
e sa
me jo
b in
about 1
0 m
inutes.
IPL w
orks o
n perso
ns w
ho are outsid
e of th
e acce
ptable lim
it for th
e Fitzp
atrick
skin pigment g
rad-
ing sca
le. A
type 6 co
uld be tre
ated sa
fely (w
ith sk
in bleaching).
No hair is v
aporize
d so
there is m
uch lo
wer risk
of p
itting around th
e hair fo
llicle itse
lf (from in
tense
heat).
IPL g
ives a
dded benefits a
s a re
sult o
f the hair re
moval tre
atm
ent. Im
proved to
ne, te
xture, a
nd
vita
lity of th
e sk
in is co
mmonly noted.
Client P
re-Qualific
atio
ns
The best ca
ndidate fo
r IPL h
air removal h
as fair skin
with
dark te
rminal h
airs. Skin
typing fo
r exposure to
ultra
violet
light ca
n be ca
tegorize
d by th
e Fitzpatrick cla
ssification
, develo
ped by D
r. Thomas Fitzp
atrick o
f Harvard M
edical
School.
Skin Type I: N
ever ta
ns, always burns (extremely fa
ir skin, b
londe hair, b
lue/green eyes)
Skin Type II: O
ccasionally ta
ns, u
sually burns (fair skin, sandy to
brown hair, g
reen/brown eyes)
Skin Type III: O
ften ta
ns, sometim
es burns (medium skin, b
rown hair, b
rown eyes)
Skin Type IV: A
lways ta
n, n
ever burns (olive skin, b
rown/black hair, d
ark brown/black eyes)
Skin Type V: N
ever burns (dark brown skin, b
lack hair, b
lack eyes)
Skin Type VI: (
black skin, b
lack hair, b
lack eyes)
Types 1
through 4 are outsta
nding ca
ndidates. T
ype 5 will h
ave e
xcelle
nt re
sults a
s well, b
ut ca
re m
ust b
e taken to
assu
re th
at the IP
L will n
ot b
urn th
e skin
. Type 6
should not u
ndergo la
ser h
air removal u
nless u
sed in
conjunction
with
skin bleaching due to th
e high risk o
f burning and hypo/hyper p
igmen
tation
issues.
References
1. B
jerrin
g P, C
ramers M, E
gekvist H
, Christiansen K, T
roiliu
s A. H
air re
ductio
n using a new intense pulsed lig
ht irra
diator a
nd a norm
al
mode ru
by laser. J C
utan Laser T
her 2
000; 2
: 63-71.
2. K
auvar A
N. T
reatm
ent o
f pseudofollic
ulitis
with
a pulsed infra
red laser. A
rch Derm
atol 2000; 1
36:1343-6.
3. E
remia S, L
i C, N
ewman N. L
aser h
air re
moval w
ith alexandrite
versus diode laser u
sing fo
ur tre
atm
ent s
essions: 1
-year re
sults. D
erm
a-
tol S
urg 2
001; 2
7: 9
25-9.
4. G
orgu M, A
slan G, A
koz T, E
rdogan B. C
omparison of a
lexandrite
laser a
nd electro
lysis fo
r hair re
moval. D
erm
atol S
urg 2
000; 2
6:37-41.
5. B
encini PL, Luci A
, Galim
berti M
, Ferra
nti G
. Long-te
rm epilatio
n with
long-pulsed neodimium:YAG laser. D
erm
atol S
urg 1
999; 2
5:175-8.
6. L
loyd JR
, Mirk
ov M. Long-te
rm evaluatio
n of th
e long-pulsed alexandrite
laser fo
r the re
moval of b
ikini h
air a
t shorte
ned tre
atm
ent
intervals. D
erm
atol S
urg 2
000; 2
6:633-7
1
WARNING: T
his d
evice produces
high level of
hazardous
light
which
may injure the eyes.
Alw
ays
use
eye
protectio
n when usin
g
the IP
L.
Warning: In
tense lig
ht is e
mitte
d fro
m th
is apertu
re. U
nprotecte
d eye exposure m
ay cau
se serio
us
injury re
sultin
g in
loss o
f vision or b
lindness. A
lways u
se IP
L eyewear.
IPL fla
sh tu
be tem
perature sen
sor. D
o
not
allow to exceed 50C or
serio
us
damage to
the tu
be will o
ccur.
Trig
ger S
witch
Cool T
ip BK7 Glass
Condenser
Temperatu
re Sen
sor
Coolin
g Ports
IPL Resurfacing
IPL re
surfa
cing is p
erfo
rmed usin
g a beam of lig
ht e
nergy which
vaporize
s the upper la
yers o
f dam-
aged sk
in at sp
ecific a
nd co
ntro
lled le
vels o
f penetra
tion. T
he procedure of-
fers m
any advantages w
hich
others d
o not h
ave. U
nlike M
icroderm
abrasion,
the IP
L penetra
tes d
eeply in
to th
e derm
is where promotio
n of co
llagen pro-
teins ca
n be stim
ulated. C
hemica
l peels ca
n be very unpredicta
ble and dan-
gerous w
hile an IP
L can be dialed in
to deliver p
recise
ly th
e rig
ht a
mount o
f radiatio
n to
produce sa
fe and effe
ctive re
sults.
All re
surfa
cing tre
atm
ents w
ork esse
ntia
lly th
e sa
me w
ay. F
irst, the outer
layers o
f damaged sk
in are strip
ped away. T
hen, a
s new ce
lls form
durin
g th
e
healing process, a
smoother, tig
hter, y
ounger-lo
oking sk
in su
rface appears.
For su
perficia
l or m
edium re
surfa
cing, th
e IP
L can be lim
ited to
the epiderm
is and papilla
ry derm
is. For d
eeper re
surfa
cing, th
e upper le
vels o
f the re
ticulas
derm
is can also
be re
moved. V
arie
d penetra
tion allows tre
atm
ent o
f specific
spots o
r wrin
kles.
It's also
importa
nt to
consid
er th
e le
ngth of re
covery w
hen ch
oosin
g among
skin-re
surfa
cing alte
rnativ
es. In
general, th
e m
ore aggressiv
e th
e re
surfa
cing
procedure is, th
e m
ore prolonged th
e re
covery is lik
ely to
be. "Lig
ht" re
sur-
facin
g procedures, su
ch as su
perficia
l chemica
l peels o
r superficia
l laser re
sur-
facin
g, o
ffer sh
orte
r recovery tim
es. H
owever, th
ese lig
hter p
rocedures m
ay need to
be re
peated
multip
le tim
es to
achieve re
sults co
mparable to
those achieved with
more aggressiv
e te
chniques.
General D
ermatology Treatm
ent o
f additio
nal sk
in afflictio
ns su
ch as R
osacea, F
ine W
rin-
kles, S
un Damaged Skin, A
cne Scars, S
cars fro
m CO2-la
ser re
surfa
c-ing, A
ge Spots, La
rge Pores, A
cne Prone Skin.
As th
e IP
L goes o
ver th
e derm
is, vascu
lar sp
aces w
ith hemoglobin in
them absorb th
e lig
ht e
nergy th
ereby heatin
g th
e su
rrounding tissu
e
and stim
ulatin
g th
e fib
roblasts to
produce ty
pe 1 co
llagen and derm
al
proteins. T
he tre
atm
ent re
arra
nges a
nd/or re
places th
e so
lar e
lasto
-sis in
the upper d
erm
is, resultin
g in
NEW co
llagen fo
rmatio
n.
What used to be loose, irre
gular collagen in the derm
is is
now
tighter, re
freshed and re
juvenated.
The benefits o
f each IP
L treatm
ent o
ver a
ll other sk
in re
juvenatio
n
procedures
inclu
de: Low downtim
e, non-su
rgica
l, little
pain and
disco
mfort,
immediate results
afte
r 1 - 2 tre
atm
ents,
affo
rdable, enhances your own collagen
growth, p
roduces m
ore derm
al p
roteins a
nd tre
ats a
ll types o
f skin.
Treatm
ent P
rocedure: R
esurfacing and W
rinkle Reductio
n
Deliver 7
pulse
s per se
cond (a
pproxim
ately 130 jo
ules) to
each area
of 2
.5 cm
square. B
e very sy
stematic a
nd th
orough, b
ut re
sist the
temptatio
n to
over tre
at. A
pplying m
ore th
an 240 jo
ules m
ay se
-verely burn th
e sk
in.
Figure 1 sh
ows n
orm
al sa
gging and wrin
kling of th
e sk
in which
can be
expecte
d as h
umans a
ge. F
igure 2 sh
ows e
xcellent im
provement o
n
a 47 year o
ld fe
male afte
r 6 tre
atm
ents.
Always sta
rt any IPL tre
atm
ent with
a 5 minute derm
al cold pack
applica
tion. This
will
substa
ntia
lly reduce patie
nt disco
mfort
and
protect th
e derm
is from excessiv
e th
erm
al re
tentio
n or d
amage fro
m
heat.
Call y
our p
atie
nt b
ack in
for a
follow up in
48 hours. A
dditio
nal tre
at-
ments m
ay be applied in
2-4 w
eeks d
epending on th
e le
vel o
f derm
al
trauma th
e patie
nt e
xperie
nce and th
eir ra
te of h
ealing.
8
Correct H
and Positio
n fo
r
Treatm
ents.
IPL Startup Procedure
Put o
n your IPL eyewear before powering up your system. W
ear th
e eye protectio
n
throughout th
e entire procedure.
Place th
e b
lue p
lugs into th
e b
lue ja
cks o
n th
e h
ybrid
driv
er u
nit firm
ly.
These ja
cks p
roduce high volta
ge cu
rrent so
the sy
stem m
ust b
e off d
urin
g
plug in
sertio
n (re
d ro
cker sw
itch off). A
s an added sa
fety m
easure, d
o not
touch th
e m
etal p
ortio
n of th
e plug w
hile in
sertin
g or re
moving fro
m th
e
driv
er (e
ven if y
ou assu
me th
e unit is o
ff). The IP
L hand piece ru
ns o
n a se
parate circu
it than th
e LD
driv
er so
the use
of th
e key lo
ck sw
itch is n
ot re
quire
d. S
witch
the re
d ro
cker sw
itch to
‘on’.
At th
is time your IP
L hand piece is LIV
E. E
xtre
me ca
re m
ust b
e exercise
d
while handling th
e IP
L. This sy
stem produces h
igh le
vels o
f potentia
lly haz-
ardous lig
ht w
hich
could in
jure unprotecte
d eyes.
Testin
g th
e IPL
With
the pulse
settin
g on 6 (se
ven pulse
s per se
cond), p
lace th
e IP
L con-
denser o
ptic 5
mm fro
m th
e black te
st sheet in
cluded w
ith your in
structio
n
materia
l. Press th
e trig
ger sw
itch th
en im
mediately re
lease (ju
st for te
sting
purposes). T
he hand piece w
ill deliver 7
pulse
s of lig
ht. R
epeat th
e te
st but
hold th
e trig
ger sw
itch down fo
r 10 se
conds. T
his w
ill deliver a
pproxim
ately
70 pulse
s which
will ig
nite
the te
st pad producin
g vapor a
nd sm
oke.
It is recommended to
use th
e IP
L in 6 pulse
s per se
cond (p
ps) a
t all tim
es
(settin
g 5) to
avoid over tre
atm
ent.
IPL Safety Consideratio
ns
IPL sh
ould not b
e used fo
r actu
al 'IP
L (i.e. la
ser) sh
aving'. T
he energy emis-
sion exit p
ort (g
lass o
ptic) is in
dire
ct contact w
ith th
e sk
in durin
g th
e tre
at-
ment. T
he re
actio
n th
at o
ccurs w
hen ra
diatio
n strik
es a
hair is v
ery in
tense
heat. It co
uld ca
use pits a
nd defects in
the optic a
s well a
s potentia
lly burn
the patie
nt's sk
in which
is in dire
ct contact w
ith th
e vaporizin
g hair.
IPL m
ust b
e used on sh
aved (o
r waxed) sk
in. T
he fo
llicle being ta
rgeted is
about 1
/8 to
1/4 in
ch below th
e sk
in (th
e fo
llicle and papilla
). If usin
g ca
r-bon d
ye, re
move any excess
which
may co
me in co
ntact
with
the optics
usin
g ethyl a
lcohol.
Lamp Overheatin
g
Keep th
e fla
sh tu
be te
mperature at o
r below 50 degrees C
entig
rade fo
r opti-
mal perfo
rmance.
Pushing the IPL
beyond the lim
its of
perfo
rmance
(operatin
g above 50C) m
ay damage th
e tu
be, re
sultin
g in
loss o
f intensity
, perfo
rmance and life
expecta
ncy of th
e IP
L (which
is not co
vered by your
standard w
arra
nty). It is a
cceptable to
spray th
e optics a
nd m
etal o
ptics
panel w
ith iso
propyl o
r ethyl a
lcohol in
term
ittently
as a
dditio
n co
oling. T
his
is an esse
ntia
l practice
when usin
g th
e IP
l for la
rge areas o
r on a ra
pid su
c-cessio
n of clie
nts. A
void sp
raying alco
hol in
the co
oling ports o
r the exhaust
fan as in
ternal d
amage to
the in
strument m
ay occu
r.
IPL Optic
s Maintenance and Lamp Breakage
Clean th
e co
ndenser o
ptics fre
quently
. For lig
ht m
aintenance use acetone
or a
lcohol o
n a co
tton tip
applica
tor. Fo
r more aggressiv
e cle
aning
use an ‘E
xacto
’ blade to
scrape any ca
rbonize
d m
ateria
l from
the glass.
Shipping Damage: The h
igh w
atta
ge fla
sh tu
be in
your h
and piece is se
nsitiv
e to
shock and m
ay be dam-
aged if th
e unit is d
ropped of m
ishandled. If y
our sy
stem
arriv
es in
non-w
orking co
nditio
n (th
e hand piece does n
ot
produce pulse
s of lig
ht e
nergy w
hen activ
ated) it h
as lik
ely
been damaged durin
g shipping. See ’La
mp Replacement
Procedure’ for instru
ctions on removal and replacement of
the high watta
ge tu
be.
3
Treatm
ent P
rocedure: R
osacea
Deliver 6
pps (a
pproxim
ately 180 jo
ules) to
each area of 2
.5 cm
square. B
e very sy
stematic a
nd
thorough but re
sist the te
mptatio
n to
over tre
at. A
pplying m
ore th
an 240 jo
ules m
ay se
verely burn
the sk
in.
Figure 1 sh
ows se
vere la
te sta
ge R
osacea of a
30
year o
ld m
ale. F
igure 2 sh
ows th
e su
bsta
ntia
l im-
provement achieved with
20 tre
atm
ents
over 24
months. S
pider v
eins a
nd enlarged ca
pilla
ries re
-quire
more tre
atm
ents o
verall th
an m
ost o
ther la
ser
procedures.
Apply ‘IP
L Capilla
ry Post T
reatm
ent G
el’ (se
e back page of p
amphlet fo
r orderin
g in
form
atio
n). T
his
form
ula co
ntains a
ctivated phylloquinone, w
hich
supports h
ealth
y re
generatio
n of n
ew ca
pilla
ries
(reducin
g th
e re
curre
nce of fu
ture Rosacea) b
y stre
ngthening th
e ca
pilla
ry walls.
Treatm
ent P
rocedure: A
ge Spots
This co
nditio
n is ca
used by m
elanin deposits in
the sk
in w
hich
do not fa
de. N
orm
al m
elanin w
ill darken (p
rolife
rate) w
ith exposure to
sun, b
ut w
ill also
fade over 4
-6 w
eeks w
hen th
e exposure is
stopped. It is m
ost co
mmon in
the elderly
but o
c-curs
in all
ages.
IPL
treatm
ents
are remarkably
effe
ctive fo
r this a
ffliction.
Deliver 7 pulse
s per second (approxim
ately 220
joules) to
each area of 2
.5 cm
square. Fa
ding of
the age sp
ots (a
lso known as ’liv
er sp
ots’) w
ill be
evident a
fter 4
-6 weeks.
Figure 3 sh
ows m
oderate age sp
ot a
ctivity
on a 46
year o
ld fe
male. N
ote th
e im
provement in
figure 4 sh
owing nearly
complete re
gressio
n of th
e sk
in
diso
rder. T
his p
atie
nt u
nderw
ent 3
treatm
ents o
ver 1
1 weeks.
Apply th
e ‘IP
L Post T
reatm
ent A
loe’ w
hich
contains b
enzocaine. T
his w
ill speed healing and re
duce
any disco
mfort a
ssocia
ted with
the la
ser tre
atm
ent.
Treatm
ent P
rocedure: S
cars and Lesions
This co
nditio
n ca
n be ca
used by any tra
uma to
the
skin fro
m acne, su
n burn, cu
ts, scrapes a
nd su
rgica
l procedures. T
o re
duce th
e appearance of th
e sca
r, it w
ill be necessa
ry to
rebuild th
e co
llagen proteins
in th
e sk
in with
IPL ra
diatio
n. T
his p
rocess is e
xten-
sive (e
specia
lly in
cases w
here se
vere sca
rring ex-
ists). It
may take 15-20 tre
atm
ents
over 12-24
months to
achieve desire
d re
sults.
Deliver 7 pps (approxim
ately 220 joules)
to each
area of 2
.5 cm
square. R
emember, a
pplying m
ore
than 240 jo
ules m
ay se
verely burn th
e sk
in. E
ach pulse
from th
e IP
L800 on m
axim
um in
tensity
will d
eliver a
pproxim
ately 20 jo
ules p
er 2
.5 cm
2. Y
ou m
ust d
eliver th
e fiv
e pulse
s in under o
ne
second fo
r maxim
um th
erm
al h
eat e
xchange in
the tissu
e.
Figure 5 sh
ows a
28 year o
ld fe
male w
ith acne sca
rring w
hich
was le
ft over fro
m te
enage puberty
. There are very deep pocks, w
hich
are th
e hardest to
improve. In
figure 6, th
e appearance of th
e
scars (in
cluding th
e pock) h
as im
proved 90%.
Apply th
e ‘IP
L Post T
reatm
ent A
loe’ w
hich
contains b
enzocaine. T
his w
ill speed healing and re
duce
any disco
mfort a
ssocia
ted with
the la
ser tre
atm
ent.
Treatm
ent around the eyes must be done with
adequate protectio
n. Exposure to IPL
radiatio
n (even th
rough th
e eye lid
) can permanently
injure th
e eyes up to
and in
cluding
blin
dness.
Photos are fo
r example purposes only and m
ay not in
dicate re
sults which will b
e achieved on every patie
nt. M
edical
IPL tre
atm
ents fo
r derm
atology purposes are ra
ted by ‘im
provement’ a
nd not b
y ‘cure’. M
any skin conditio
ns such
as Rosacea m
ay re
turn and re
quire
future tre
atm
ents to
be contro
lled. A
dvise your p
atie
nt to
expect im
provement
but c
autio
n th
em as to
which degree of im
provement th
ey will b
e able to
achieve.
9
LD80-IPL800 Control Locatio
ns/Feature Descriptio
ns
A.
Key Lockout:
This fe
ature is re
quire
d by la
w on all h
igh-power la
ser a
nd lig
ht d
evice
s. The first ste
p in
the co
rrect se
quence to
power-u
p your la
ser is to
turn th
is clockwise
us-
ing th
e sp
ecia
l key in
cluded in
your k
it. The lig
ht (ce
nter LE
D la
mp) w
ill be off w
hen th
e
power sy
stem is o
ff and re
d when th
e power sy
stem is o
n.
B.
System Status LED: This lig
ht w
ill indica
te sy
stem sta
tus (n
eutra
l or liv
e). B
lue in
di-
cates y
our IP
L is live and re
ady fo
r use.
C.
Pulse Control: T
his a
llows th
e operator to
set th
e number o
f laser p
ulse
s per se
cond.
D.
IPL Jacks: An eight-p
rong co
axial p
ower ja
ck fo
r the diode la
ser h
and piece and tw
o
blue banana plug re
ceptacle
s. E.
Power Cord: Rated fo
r 60Hz, 1
20-240 V
, 10 A
mp w
ith co
rresponding plug-sty
le fo
r country
of d
estin
atio
n.
F. IPL Instrument: A
360 W
att h
igh in
tensity
pulse
d lig
ht w
ith th
umb sw
itch.
G.
Eyewear: This is a
n esse
ntia
l part o
f the tre
atm
ent p
rocess. D
irect o
r refle
ctive IP
L radiatio
n ca
n se
riously
injure th
e eye. B
oth th
e te
chnicia
n and th
e patie
nt m
ust u
se th
e
protectiv
e eyewear w
hile th
e IP
L is enabled or a
ctivated. E
yewear is in
tended fo
r acci-
dental e
xposure only. N
ever sta
re dire
ctly in
to an IP
L optic.
H.
Carbon Dye: This is a
n ‘a
tomize
d’ fo
rm of m
olecular ca
rbon w
hich
easily
penetra
tes
deeply in
to th
e fo
llicle sh
aft. T
he dye adds p
igment w
hich
gives a
receptor fo
r the pho-
ton/heat e
xchange re
actio
n. T
he ca
rbon atoms w
ill capture th
e IP
L energy and co
nvert it
into heat fo
r the ra
pid and efficie
nt ca
uteriza
tion of tissu
e fo
r the perm
anent d
estru
ction
of th
e hair fo
llicle organ.
I. High-Precision Tweezers: Apparatus fo
r the extra
ction of fo
llicle prio
r to ca
rbon dye
applica
tion.
J. Temperature Readout:
Contro
l feature fo
r the re
gulatio
n of th
e fla
sh tu
be in
ternal
temperature. D
o not e
xceed 50C.
K.
Precision Optic
s: BK7 G
lass co
ndenser o
ptic fo
r the efficie
nt fo
cus a
nd penetra
tion of
light e
nergy th
rough th
e sk
in. M
ay be ch
anged to
ruby or sa
pphire
(see su
pplies).
2
Equipment W
arranty
We w
arra
nt to
the orig
inal p
urch
aser th
e eq
uipment m
anufactu
red by u
s to be fre
e from defects in
material an
d w
ork-
manship under n
orm
al u
se and se
rvice
. Our o
bligatio
n under th
is warra
nty sh
all be lim
ited to
the re
pair o
r exch
ange of
any part o
r parts w
hich
may prove defe
ctive under n
orm
al u
se an
d se
rvice with
in 12 ca
lendar m
onths fro
m th
e date of
shipmen
t and which
our e
xam
inatio
n sh
all d
isclose to
our sa
tisfactio
n to
be th
us d
efective
. When
necessa
ry, p
urch
aser
shall a
pply fo
r a Retu
rn M
ateria
ls Authorizatio
n and in
structio
ns o
n proper re
turn procedures fro
m th
eir orig
inal sale
s asso
ciate. T
he lase
r diode (h
ead) re
quire
s specia
l operatin
g precautio
ns w
hich
, if defie
d, m
ay vo
id warran
ty.
Warranty Extension Certific
atio
n:
Cu
stom
er Nu
mb
er A
uth
orizatio
n N
um
ber
Warran
ty E
xten
sion
( ) y
ears W
arranty
Typ
e: A B
C D
A
B
C
D
E
F G
H
I J
Pre-Treatm
ent
Before applying tre
atm
ent, re
move all h
air fro
m th
e area by tw
eezin
g or w
axing. La
ser h
air re
-moval is m
ost e
ffectiv
e w
hen applied to
an empty fo
llicle sh
aft. H
uman hair sim
ply does n
ot h
ave
enough pigment to
allow fo
r sufficie
nt h
eat e
xchange to
cauterize
, desicca
te and necro
tize th
e ce
lls which
produce hair. T
o co
mpensate fo
r this la
ck of ‘q
uantita
tive’ a
nd ‘q
ualita
tive’ p
hoton ta
rgets, it
will b
e necessa
ry to
place a high-density
carbon dye in
side th
e fo
llicle prio
r to tre
atm
ent.
Isolate th
e hairs to
perm
anently
destro
y. It w
ill be necessa
ry to
remove th
em by sw
iftly plucking
(or w
axing) in
the dire
ction of g
rowth. P
ullin
g slo
wly generally le
aves m
ost o
f the fo
llicle tissu
e
insid
e th
e pore which
will b
lock th
e dye.
Photo-Reactiv
e Dye Applicatio
n
Usin
g a co
tton-tip
ped applica
tor, co
mpletely co
ver th
e tre
atm
ent a
rea with
the sp
ecia
l dye in
cluded
in your k
it. Massa
ge th
e dye in
to th
e fo
llicle pore with
a firm
downward circu
lar m
otio
n. R
epeat 2
-3 tim
es to
saturate th
e fo
llicle pore. U
se an ethyl alcohol based w
ipe (iso
propyl a
lcohol w
ill not
disso
lve th
e dye) to
lightly
clean th
e excess fro
m th
e su
rface of th
e sk
in. A
t this p
oint y
ou w
ill have all d
esire
d fo
llicles v
isibly highlig
hted with
a dark sp
ot (a
s seen above) a
nd are re
ady to
power u
p your la
ser fo
r treatm
ent.
Pointer: If y
our p
atient o
bjects to
having a depilatory process before th
e tre
atm
ent, y
ou m
ay contin
ue w
ithout th
e carbon dye. T
his
alte
rnate procedure is th
e equivalent o
f ‘laser s
having’ (fo
r which long-te
rm perm
anency is m
arginal). F
or b
est re
sults, th
e use of a
photo-
reactiv
e dye is highly re
commended.
Dermal C
oolant A
pplicatio
n
Place a th
in la
yer o
f laser d
erm
al co
olant sp
ray on th
e tre
atm
ent a
rea prio
r to la
ser a
pplica
tion.
This w
ill protect th
e su
rface of th
e sk
in fro
m burning as w
ell a
s improve th
e tra
nslu
cency of th
e
skin (ra
te at w
hich
light ca
n pass). Fa
ilure to
use th
e derm
al co
olant p
rep m
ay re
sult in
unneces-
sary d
iscomfort fo
r the patie
nt d
urin
g tre
atm
ent a
nd in
crease th
e lik
elihood of a
surfa
ce burn.
Should th
e liq
uid become dry, it w
ill be necessa
ry to
re-apply fre
quently
. The use of a
humidifie
r in dry clim
ates w
ill substa
ntia
lly prolong th
e duratio
n fo
r which
the derm
al p
rep w
ill retain its co
ol-
ing propertie
s.
The Treatm
ent P
rocedure
Shine th
e re
d dot o
n th
e highlighted hair fo
llicle. A
djust th
e dista
nce of th
e la
ser h
ead fro
m th
e
tissue to
create a pin-point o
f focus. T
he optim
al b
eam diameter fo
r maxim
um in
tensity
is roughly
1 m
m. T
he fo
llicle w
ill begin to
flash as th
e photon energy re
acts w
ith th
e ca
rbon dye. It is a
lso
norm
al to
see so
me gaseous e
missio
ns (v
apor a
nd sm
oke). C
ontin
ue to
hold th
e la
ser in
place until
all v
isible re
activ
ity ce
ases. T
his m
ay ta
ke up to
15 se
conds. M
ove on to
the next fo
llicle and
repeat. S
ome patie
nts m
ay fin
d th
e la
ser tre
atm
ent u
ncomforta
ble. In
these ca
ses th
e use of a
topica
l anesth
etic su
ch as lid
ocaine (a
synthetic a
mide, C
14H22N2O, u
sed ch
iefly
in th
e fo
rm of its
hydrochlorid
e as a
local a
nesth
etic a
nd antia
rrhythmic a
gent) w
ill reduce disco
mfort. A
mild cry
o-
genic (n
itrogen-based) to
pica
l spray will a
lso m
inim
ize any pain.
Treatm
ent Around or Near the Eyes: Great ca
re m
ust b
e exercise
d w
hen
workin
g near th
e eyes. T
he la
ser
emissio
n is p
owerfu
l enough to a
ctually p
enetra
te the e
yelid
and perm
anen
tly damage th
e eye. H
avin
g th
e patie
nt
close th
eir eyes is n
ot sa
tisfacto
ry protectio
n. T
he u
se of a d
ark-colo
red damp wash clo
th which
is folded over fo
ur
times w
ill defle
ct the h
arm
ful ra
diatio
n; h
owever, o
nly la
ser p
rotectiv
e eyew
ear is re
commended.
Treatm
ent A
round or Near Mucus Membranes: La
ser ra
diatio
n will se
verely
damage th
e tissues in
side th
e nose and ear can
al. Treatm
ent sh
ould be avoid
ed in
these a
reas alto
gether.
Treatm
ent Around or Near the Genita
ls: La
ser h
air removal is sa
fe fo
r applica
tion to
the p
ubic re
gions in
clud-
ing th
e reproductiv
e organs o
f both sex
es. C
are m
ust b
e ta
ken
into co
nsid
eratio
n in
these a
reas d
ue to
the in
-cre
ased le
vel o
f neural se
nsitivity
. The patie
nt m
ay fin
d th
e process u
ncomforta
ble w
ithout a to
pical.
Treatm
ent Around or Near the Areola (nipple): La
ser h
air re
moval is safe
and effe
ctive on hair g
rowth which
occu
rs from th
e areola of b
oth se
xes. A
gain, ca
re m
ust b
e tak
en in
to co
nsid
eratio
n in
these areas d
ue to
the in
-cre
ased le
vel o
f neural se
nsitivity
. Post-T
reatm
ent:
The skin
surro
unding the tre
atment area may experie
nce short-te
rm eryth
mia (re
ddening)
which
will su
bsid
e w
ithin 12 hours. S
hould th
e treatm
ent a
rea sh
ow sig
ns of e
xcess sca
bbing you m
ay w
ish to
reduce th
e overall tre
atm
ent tim
e or in
tensity
. The applica
tion of a
post-tre
atm
ent co
oling and healin
g gel (su
ch as
Aloe) is e
ncouraged to
speed healin
g an
d re
duce se
nsitivity
. Instru
ct the p
atien
t to refrain
from applyin
g co
smetics
or su
nbathing fo
r at le
ast 2
4 hours.
Intense Pulsed Light P
rogressively Permanent H
air Removal
The IP
L can be co
nsid
ered an excellent re
placement fo
r laser h
air re
moval a
s the re
sults a
nd over-
all p
rocedure are sim
ilar in
many w
ays. It ca
n be noted th
at IP
L treat-
ments a
re m
ore efficie
nt d
ue to
the su
bsta
ntia
l incre
ase in
overall e
nergy
being used (w
hich
equates to
less o
verall tre
atm
ent tim
e).
Like la
ser, IP
L will in
jure th
e ce
lls which
are re
sponsib
le fo
r hair g
rowth
by w
ay of th
erm
olysis (h
eat in
the fo
llicle tissu
e). T
his tra
uma is ju
st below th
e th
reshold of in
jurin
g other ce
lls (notably sk
in) a
round th
e fo
lli-cle
. IPL w
orks b
est o
n clie
nts w
ho have lig
ht sk
in co
mbined w
ith dark
hair g
rowth. S
hould a hair fo
llicle su
rvive th
e IP
L treatm
ent, it w
ill grow
back slo
wer a
nd th
inner. A
fter a
serie
s of tre
atm
ents th
e co
ntin
ual ‘site
specific’ lo
calize
d tra
uma to
the fo
llicle tissu
e w
ill eventually destro
y th
e hair g
rowth. O
nce de-
stroyed, a
follicle
cannot p
roduce another h
air.
Discomfort a
nd Client R
eactio
n
Remarkably, the sensatio
n felt
with
an IPL tre
atm
ent is
no more intense than that of a laser
(alth
ough m
uch m
ore to
tal e
nergy is b
eing delivered to
the tissu
e). T
he first tw
o pulse
s from th
e
IPL g
enerally are not fe
lt by th
e clie
nt. T
he th
ird (if th
e te
chnicia
n ch
ooses to
deliver th
at m
any)
begins to
feel lik
e a sn
ap of a
rubber b
and (a
s the tissu
e absorbs a
nd re
tains th
e energy). F
ive or
more pulse
s in le
ss than one se
cond m
ay be uncomforta
ble fo
r some clie
nts. T
he use of a
topica
l desensitizin
g sp
ray or p
re-tre
atm
ent co
ld pack will a
lleviate m
ost se
nsatio
n.
Pre-Treatm
ent P
reparatio
n
First sp
ray th
e area w
ith a lid
ocaine or b
enzocaine to
pica
l numbing co
mpound. N
ow place a co
ld
pack over th
e area in
tended to
be tre
ated fo
r a m
inim
um of 5
minutes p
rior to
treatm
ent. T
he
patie
nt w
ill be able to
with
stand as m
any as 7
pulse
s per 2
.5 cm
2/se
cond w
ithout m
uch se
nsatio
n.
It is generally not n
ecessa
ry to
deliver m
ore th
an 5 pulse
s for e
ffectiv
e hair re
moval tre
atm
ent.
IPL Hair Removal V
ariatio
n 1
This
procedure is th
e m
ost p
opular a
mong professio
nals a
s it re
quire
s only
shaving prio
r to th
e applica
tion. It w
ill be necessa
ry to
remove all h
air a
bove
the sk
in w
ith a ra
zor. A
ny hair w
hich
protru
des a
bove th
e sk
in m
ay ca
use pits
in your o
ptics w
hich
will re
duce th
e overall e
fficiency of th
e device
. Turn your IP
L driv
er to
settin
g 6 pulse
(180 jcm
2 per se
cond) a
place th
e IP
L condenser a
gainst th
e sk
in in th
e area where th
e u
nwanted h
air g
rowth is
occu
rring. P
ress th
e trig
ger sw
itch th
en re
lease (d
eliverin
g fo
ur to
tal e
missio
n
equatin
g to
180 jcm
2 of e
nergy density
) then m
ove th
e co
ndenser to
the next
treatm
ent a
rea. T
he tre
atm
ent w
ill effe
ctively damage or d
estro
y all a
nagen fo
llicles in
an area of
2.5 cm
2. A
n area 25cm
square (a
bout 1
0 in
ches) w
ill require
d 100 pulse
s spaced evenly fo
r effe
c-tiv
e hair re
moval.
IPL Hair Removal V
ariatio
n 2: D
eep Tissue Trauma W
ith Follic
le Ex-
tractio
n with
Carbon Dye
Before applying tre
atm
ent, re
move all h
air fro
m th
e area by tw
eezin
g or w
axing. IP
L hair re
moval
is most e
ffectiv
e w
hen applied to
an empty fo
llicle sh
aft. H
uman hair sim
ply does n
ot n
orm
ally
have enough pigment to
allow fo
r sufficie
nt h
eat e
xchange to
cauterize
, desicca
te and necro
tize
the ce
lls which
produce hair. T
o co
mpensate fo
r this la
ck of ‘q
uantita
tive’ a
nd ‘q
ualita
tive’ p
hoton
targets, it w
ill be necessa
ry to
place a high-density
carbon dye in
side th
e fo
llicle prio
r to tre
atm
ent.
Usin
g a co
tton-tip
ped applicato
r, completely
cover th
e tre
atm
ent a
rea w
ith th
e sp
ecial d
ye in
cluded in
your kit.
Massa
ge th
e dye in
to th
e follicle
pore w
ith a firm
downward circu
lar m
otio
n. R
epeat 2
-3 tim
es to
saturate th
e follicle p
ore. U
se an ethyl alcohol based w
ipe (iso
propyl alco
hol w
ill not d
issolve th
e dye) to
lightly
clean th
e excess fro
m th
e su
rface of th
e skin
. At th
is poin
t you will h
ave all d
esire
d follicle
s visibly highlighted w
ith a dark
spot (a
s seen above). P
erfo
rm th
e stan
dard IP
L treatm
ent a
s outlin
ed in
‘IPL H
air R
emoval V
ariatio
n 1’ a
s norm
al. Don not o
ver tre
at. A
pplyin
g 10 or m
ore pulse
s in 1 se
cond to
the sa
me area m
ay re
sult in
a se
vere b
urn (le
ading
to bliste
ring).
4
IPL Tatto
o Removal
To begin th
e process it w
ill be necessa
ry fo
r you to
scrub th
e sk
in over th
e ta
ttoo w
ith an abrasiv
e
applica
tor. T
his is w
ill remove th
e outer la
yers o
f the epiderm
is which
will a
llow fo
r greater p
ene-
tratio
n of th
e IP
L radiatio
n.
Usin
g a depilatory w
ax or e
pilatio
n paper, re
move all h
air fro
m th
e ta
ttoo area. H
air g
rowth w
ill block so
me of th
e IP
L radiatio
n fro
m enterin
g th
e ta
ttoo. F
ollicle
s in th
e sk
in of th
e ta
ttoo w
ill also
be perm
anently
damaged by th
e ra
diatio
n which
may not b
e desira
ble to
your p
atie
nt.
The Treatm
ent P
rocedure
Carefully power u
p your IP
L (see page 4). D
ial in
PPS. P
lace th
e glass co
ndenser sid
e down (in
contact w
ith th
e sk
in) o
n to
p of th
e ta
ttoo.
Deliver 7
pulse
s (approxim
ately 220 jo
ules) to
each area of 2
.5 cm
square (d
epending on co
lor).
Be very sy
stematic a
nd th
orough, b
ut re
sist the te
mptatio
n to
over tre
at. A
pplying m
ore th
an 240
joules p
er cm
2 m
ay se
verely burn th
e sk
in. B
lack in
k ca
n be su
ccessfu
lly tre
ated w
ith 100 jcm
2.
Blue and green norm
ally re
quire
s 180 jcm
2, a
nd re
d re
quire
s up to
220.
The example ta
ttoo at rig
ht w
ould re
quire
427 pulse
s for a total of roughly 10,000
joules.
Apply th
e post tre
atm
ent co
oling gel to
the
tatto
o and allow to dry. This
is a very
importa
nt ste
p w
hich
should not b
e omit-
ted. A
lthough th
e gel does contain th
e
desensitizin
g co
mpound benzocaine it w
ill be quite
common for the patie
nt to feel
some burning in the minutes
and hours
following the procedure.
This
is quite
norm
al. If th
e patie
nt re
quests e
xtra
relief, a
pply a co
ld pack as n
eeded.
In pictu
re number 4
, you ca
n se
e so
me of th
e re
dness, sw
ellin
g and sca
bbing w
hich
may sh
ow up
1-3 days fo
llowing tre
atm
ent. In
pictu
re number 5
and 6, y
ou ca
n se
e so
me fa
ding of th
e ta
ttoo,
but a
lso a m
ild fo
rm of h
ypo pigmentatio
n (lo
ss of th
e patie
nt’s n
atural sk
in co
lor). T
his co
nditio
n
is temporary and will su
bsid
e as th
e m
elanin re
generates w
ith natural h
ealing.
In pictu
re number 7
, you ca
n se
e th
at th
e ta
ttoo has fa
ded to
a point w
here it is n
ot re
cogniza
ble.
This ty
pe of ta
ttoo sh
ould re
quire
about 6
treatm
ents o
ver 7
months. It is a
lways a
good id
ea to
take pictu
res o
f your p
atie
nt’s tre
atm
ent a
reas to
show th
em th
e ste
ady im
provement. T
his w
ill help th
em to
stay co
mmitte
d and m
otiv
ated as th
e process re
quire
s a su
bsta
ntia
l investm
ent o
f tim
e.
7
1
2
3
4
5
6
7
8
9
10
1
1
1
2
13
1
4
15
1
6
17
1
8
19
2
0
21
2
2
23
2
4
25
2
6
27
2
8
29
3
0
31
3
2
33
3
4
35
3
6
3
7
38
3
9
40
4
1
42
4
3
44
4
5
4
6
47
4
8
49
5
0
5
1
Pa
tien
t
Gro
up
Tre
atm
en
t
Are
a
Ta
ttoo
Cle
ara
nce
(Avera
ge)
No
tes
2 P
atie
nts
Bla
ck In
k O
nly
Arm
s 9
0%
afte
r
3 m
os.
5 trea
tmen
t avera
ge
5 P
atie
nts
Blu
e an
d B
lack
Ink
To
rso
90%
afte
r
3 - 1
2 m
os.
8 trea
tmen
t avera
ge
Intense Pulsed Light T
atto
o Removal
Nearly
1/2 of a
ll people w
ith ta
ttoos e
ventually w
ant th
em re
moved. U
ntil re
cently
these people
had no viable (a
nd sa
fe) o
ptio
ns a
vailable to
them. In
the m
id 1980’s la
sers h
ad been used experi-
mentally to
remove th
e pigment w
ith encouraging su
ccess ra
tes. A
newer p
rocedure used an in
-tense pulse
d lig
ht. S
urprisin
gly, la
sers a
nd IP
L’s do not a
ctually burn th
e in
k out; th
ey fra
cture it
into tin
y pieces w
hich
are th
en re
moved fro
m th
e sk
in by your im
mune sy
stem.
On average, p
rofessio
nal ta
ttoos re
quire
5-6 tre
atm
ents, w
hile amateur ta
ttoos m
ay re
quire
3-4
treatm
ents, sp
aced approxim
ately 2-4 w
eeks a
part. T
he number o
f treatm
ents d
epends o
n th
e
amount a
nd ty
pe of in
k used and th
e depth of th
e in
k in
the sk
in. O
ccasio
nally te
chnicia
ns h
ave
needed to
treat a
tatto
o 10-20 tim
es.
What s
hould I charge fo
r th
e procedure? T
he fe
e depends o
n th
e size
of e
ach ta
ttoo, a
nd how
many tre
atm
ents it ta
kes to
lighten or re
move it to
your sa
tisfactio
n. E
ach ta
ttoo tre
atm
ent g
ener-
ally co
sts $135 fo
r the 1st sq
uare in
ch and $25 fo
r each additio
nal in
ch. If m
ore th
an one ta
ttoo is
being tre
ated at th
e sa
me tim
e, y
ou m
ay offe
r pricin
g alte
rnativ
es. A
consulta
tion fe
e of $
40-$60
should be asse
ssed fo
r this q
uote.
What will
the treatm
ent be lik
e? It is le
ss painful to
have a ta
ttoo re
moved th
an gettin
g it p
ut
on. A
numbing sp
ray and ice
pack sh
ould be applied before th
e procedure. A
fter th
e procedure th
e
treated area m
ay bliste
r, swell, cru
st, scab, o
r bleed slig
htly
. Care fo
r the tre
ated area daily in
order to
prevent in
fectio
n and to
get th
e best p
ossib
le healing re
sults. T
he ta
ttoo w
ill then gradu-
ally fa
de fo
r 2-4 w
eeks w
hen it ca
n be tre
ated again. Y
ou m
ay se
e additio
nal fa
ding fo
r as lo
ng as
several m
onths so
you ca
n sp
ace th
e tre
atm
ents fa
rther a
part b
ut n
ot clo
ser th
an 2 weeks.
Important C
onsideratio
ns fo
r Safe IPL Tatto
o Treatm
ent
Treatm
ent on Skin with
Hair Growth: One of th
e m
ajor sid
e effe
cts of d
iode la
ser ta
ttoo re
-moval is d
estru
ction of h
air fo
llicles. If y
our clie
nt w
ould lik
e a ta
ttoo re
moved fro
m an area in
which
there is ‘d
esira
ble’ h
air g
rowth, m
anually extra
ct all fo
llicles b
efore tre
atm
ent. T
he use of a
n
aggressiv
e depilatory w
ax is b
est. If th
e fo
llicle is re
moved th
ere w
ill be fa
r less d
amage to
the
papilla
cells w
hich
produce growth. T
he hair fo
llicle unit w
ill regenerate in
4-6 weeks.
Treatm
ent Around or Near the Genita
ls: IP
L tatto
o re
moval is sa
fe fo
r applica
tion to
the pubic
regions in
cluding th
e re
productiv
e organs o
f both se
xes. C
are m
ust b
e ta
ken in
to co
nsid
eratio
n in
these areas d
ue to
the in
creased le
vel o
f neural se
nsitiv
ity. T
he patie
nt m
ay fin
d th
e process u
n-
comforta
ble with
out a
topica
l desensitizin
g sp
ray.
Treatm
ent Around or Near the Eyes: G
reat ca
re m
ust b
e
exercise
d w
hen w
orking near th
e eyes. T
he IP
L emissio
n is
powerfu
l enough to
actu
ally penetra
te th
e eyelid and perm
a-
nently
damage th
e eye. H
aving th
e patie
nt clo
se th
eir e
yes is
not sa
tisfacto
ry protectio
n. T
he use of a
dark-co
lored damp
wash clo
th which
is
folded over four tim
es will
defle
ct the
harm
ful radiatio
n; however,
only IPL protectiv
e eyewear is
recommended.
Post-T
reatm
ent:
The sk
in su
rrounding th
e tre
atm
ent a
rea
will
experie
nce short-te
rm erythmia (re
ddening) which
will
subsid
e w
ithin 12-24 hours. S
hould th
e tre
atm
ent a
rea sh
ow
signs o
f excess sca
bbing you m
ay w
ish to
reduce th
e overall
treatm
ent tim
e or
intensity
. The applica
tion of a post-
treatm
ent co
oling and healing gel (su
ch as A
loe) is e
ncour-
aged to
speed h
ealing and re
duce se
nsitiv
ity. In
struct th
e
patie
nt to
refra
in fro
m applying co
smetics o
r sunbathing fo
r at le
ast 2
4 hours.
REFERENCES
Nestor, M
ark S., M
D, P
hD, "L
aser H
air R
emoval: C
linical R
esults and Practical A
pplica-
tions of S
electiv
e Phototherm
olysis", S
kin & Aging, Ja
nuary 1998.
Lask, Gary, MD, Elman, Monica, MD, Slatkine, Michael, PhD, Waldman, Amir,
PhD,
Rozenberg, Zvi,
PhD, "Laser-A
ssisted Hair
Removal by Selectiv
e Phototherm
olysis:
Prelim
inary Results", th
e American Society fo
r Derm
atology Surgery, 1
997.
6
—Black in
k absorbs all w
avelengths of lig
ht a
nd re
sponds very well to
IPL tre
atm
ents.
—Green and Blue in
k absorbs 670-890nm lig
ht b
est a
nd re
sponds very well to
IPL tre
atm
ents.
—Red, O
range, a
nd Purple in
ks absorb 500-700nm lig
ht b
est a
nd re
sponds very well to
IPL tre
atm
ents.
—Turquoise re
sponds varia
bly, d
epending on th
e pigments in
the in
k.
—Flesh to
nes te
nd to
reflect lig
ht a
nd does not re
spond well to
IPL tre
atm
ents.
—Yellow te
nds to
reflect lig
ht a
nd does not re
spond well to
IPL tre
atm
ents.
before
afte
r
Treatm
ent E
fficacy
Perm
anent h
air re
moval is a
gradual p
rocess w
hich
takes 9
0 days o
r more fo
r complete destru
ction
of th
e fo
llicle tissu
es. E
ach hair m
ust g
o th
rough its e
ntire
growth cy
cle fo
r it to be effe
ctively
treated. G
enerally, it is o
nly durin
g th
e early anagen phase th
at it is v
ulnerable to
destru
ction.
The fo
llowing ch
art w
ill give you an accu
rate example of what th
e re
ductio
n in growth activ
ity
should lo
ok lik
e fro
m 30, 6
0 , a
nd 90 days o
f treatm
ents.
Important C
onsideratio
ns fo
r Safe IPL Hair Removal Treatm
ent
Treatm
ent Around or Near the Eyes: G
reat ca
re m
ust b
e exercise
d when
working near th
e eyes. The IPL em
is-sio
n is p
owerfu
l enough to
actu
ally penetra
te th
e ey
elid an
d perm
anently
damage th
e eye. H
aving th
e patien
t close
their e
yes is n
ot sa
tisfacto
ry protectio
n. T
he use of a
dark-co
lored damp wash clo
th which
is folded over four tim
es will
defle
ct the harm
ful radiatio
n; however,
only laser protectiv
e eyewear is re
commen
ded.
Treatm
ent Around or Near Mucus Membranes: IP
L radiation
will sev
erely
damage th
e tissu
es in
side th
e nose an
d ear ca
nal. T
reatm
ent sh
ould be av
oided in
these areas alto
-gether.
Treatm
ent Around or Near the Genita
ls: IP
L hair re
moval is safe
for a
pplica
tion to
the
pubic re
gions in
cluding th
e reproductive
organs o
f both sex
es. C
are m
ust b
e ta
ken in
to
consid
eratio
n in
these areas d
ue to
the in
creased le
vel of n
eural sen
sitivity. T
he p
atie
nt m
ay fin
d th
e process u
ncomforta
ble w
ithout a
topical d
esen
sitizing sp
ray.
Treatm
ent Around or Near the Areola (nipple): IP
L hair re
moval is sa
fe and effe
ctive on hair g
rowth which
occu
rs from th
e areola o
f both se
xes.
Post-T
reatm
ent:
The
skin surro
unding the tre
atm
ent area will
experien
ce short-te
rm
erythmia (re
ddening) w
hich
will su
bsid
e w
ithin 12-24 h
ours. S
hould th
e trea
tment a
rea
show sig
ns of e
xcess sca
bbing you m
ay wish
to re
duce th
e overall tre
atm
ent tim
e or in
ten-
sity. T
he a
pplica
tion of a
post-tre
atm
ent co
oling an
d healin
g gel (su
ch as A
loe) is e
ncour-
aged to
speed healin
g an
d re
duce se
nsitivity
. Instru
ct the patie
nt to
refrain
from applyin
g
cosm
etics o
r sunbath
ing fo
r at le
ast 2
4 hours.
Over Treatm
ent: E
ach IP
L pulse
sends a
serie
s of photon
‘bundles’
deep in
to th
e skin
where it d
amages th
e hair follicle
tissues. T
his
IPL ra
diatio
n also
will h
ave m
ild effe
cts on ca
pilla
ries an
d skin
tissue. If too
many IP
L pulse
s are administe
red th
e ca
pilla
ry netw
ork w
ill begin to
break down. T
his w
ill create a
bruise
which
will ta
ke se
veral d
ays to
subsid
e. A
lthough th
e use of la
sers to
destro
y ca
pil-
larie
s in th
e skin
is quite co
mmon (fo
r spider v
eins, p
ort w
ine stain
s, birth
mark
s etc), it is
not th
e in
tent o
f this tre
atm
ent a
s outlin
ed fo
r hair re
moval to d
amage other tissu
es. Fo
r that re
ason th
e te
chnicia
n sh
ould ca
refully te
st and document h
ow m
any la
ser p
ulse
s each
patie
nt ca
n with
stand befo
re ca
pilla
ry breakdown (b
ruisin
g) o
ccurs.
The gen
eral ru
le of th
umb is to
patch
test the skin
with
7 pulse
s (on fu
ll power) th
en se
nd th
e patien
t home. H
ave
them back in
the office
in 24 hours to
observe th
e re
actio
n. If th
ere is n
o burning or b
ruisin
g, a
dministe
r the fu
ll tre
atm
ent. It is n
ot re
commended to
deliver m
ore th
an 10 pulse
s to one sta
tionary area a
t a time. If m
ore th
an 10
pulse
s are deliv
ered th
e te
chnicia
n sh
ould m
ake a sm
all circular m
otio
n w
ith th
e IP
L head to
avoid
sending all th
e energy th
rough th
e exact sa
me e
ntry p
oints.
This IP
L can cau
se serio
us b
urns to
the skin
. All te
chnician
s should adopt th
e ‘le
ss is more’ p
hilosophy. It is fa
r safer to
have th
e patie
nt co
me b
ack fo
r additio
nal tre
atm
ents th
an to
administe
r too m
uch ra
diation
in one se
ssion
resultin
g in
tissue tra
uma an
d bliste
ring.
5
30
da
ys
60 d
ay
s 9
0 d
ay
s
Fluence
180J/c
m2 m
ax
Energy Instability
19% m
aximum
Safety goggles
OD 8.0 @
100-1000nm (m
inim
um)
suggested.
Electrical re
quire
ments
100/120 VAC, 5
0/60 Hz nominal, 1
.0 A
max. 2
20 or 2
40 VAC, 5
0/60 Hz
nominal, 1
.2 A m
ax.
Ambient o
peratin
g
temperature
10°C to
30°C
Ambient storage
temperature
-25°C to
70°C
Emittin
g wavelength
(100-800 ± 10) n
m
Classific
atio
n: E
xempt
Output p
ower
User-a
djustable 0 to
130 Jo
ules
Designatio
n: O
EM
Generatio
n m
odes
IPL
Manufacturer: Q
uazar In
dustrie
s,
UK
Beam characteristic
Flash Lamp
Warra
nty: 1
Year
Pulse duratio
n
Manual A
djust
Emission In
dicator: Y
es
Weight
15 kg m
ax
Key Lock: Y
es
Optics
Glass
Beam Shutte
r: No
Dimensions
170 x 500 x 370 m
m
21CFR 1040, IE
C 825-1:1993: N
o
Patie
nt #
hair counts
12 week clearance
1 fe
males, 1
males
pre
post
number of tr
eatm
ents
percent
#1: d
eep tissu
e with
hair
225
11
10
95%
#2: d
eep tissu
e with
dye
166
1
7
99%
Over-tre
atm
ent
capilla
ry bruising
minor blistering
before
afte
r