jet - jetinox - jetcom...jet 82 hs 9 8 5 4 3 2 7 6 jet 112 - jetinox 112 0 0,5 1 1,5 2 2,5 3 3,5 4 q...

3
® JET - JETINOX - JETCOM SELF-PRIMING CENTRIFUGAL PUMPS MODEL JET 62 M JET 62 T JET 82 M JET 82 T JET 102 M JET 102 T JET 112 M JET 112 T JET 92 M JET 92 T JET 132 M JET 132 T JET 151 M JET 151 T JET 251 M JET 251 T JET 200 M JET 200 T JET 300 M JET 300 T JETINOX 82 M JETINOX 82 T JETINOX 102 M JETINOX 102 T JETINOX 112 M JETINOX 112 T JETINOX 92 M JETINOX 92 T JETINOX 132 M JETINOX 132 T JETCOM 62 M JETCOM 62 T JETCOM 82 M JETCOM 82 T JETCOM 102 M JETCOM 102 T JETCOM 92 M JETCOM 92 T JETCOM 132 M JETCOM 132 T VOLTAGE 50 Hz P1 MAX kW In A 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V~ 3x230-400 V~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 0,72 0,67 0,85 0,86 1,13 1,04 1,4 1,35 0,94 0,93 1,49 1,43 1,6 1,6 2,2 2,2 2,0 2,0 2,7 2,7 0,85 0,86 1,13 1,04 1,4 1,35 0,94 0,93 1,49 1,43 0,72 0,67 0,85 0,86 1,13 1,04 0,94 0,93 1,49 1,43 0,44 0,44 0,6 0,6 0,75 0,75 1 1 0,75 0,75 1 1 1,1 1,1 1,85 1,85 1,5 1,5 2,2 2,2 0,6 0,6 0,75 0,75 1 1 0,75 0,75 1 1 0,44 0,44 0,6 0,6 0,75 0,75 0,75 0,75 1 1 12,5 12,5 16 25 14 25 31,5 40 31,5 40 12,5 16 25 14 25 12,5 12,5 16 14 25 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 0,6 0,6 0,8 0,8 1 1 1,36 1,36 1 1 1,36 1,36 1,5 1,5 2,5 2,5 2 2 3 3 0,8 0,8 1 1 1,36 1,36 1 1 1,36 1,36 0,6 0,6 0,8 0,8 1 1 1 1 1,36 1,36 H (m) 3,12 2,1-1,2 3,8 2,8-1,6 5,1 3,3-1,9 6,2 4,3-2,5 4,2 3,3-1,9 6,6 4,7-2,7 7,2 5,2-3 10 6,9-4 9 6,8-3,9 12 8,5-4,9 3,8 2,8-1,6 5,1 3,3-1,9 6,2 4,3-2,5 4,2 3,3-1,9 6,6 4,7-2,7 3,12 2,1-1,2 3,8 2,8-1,6 5,1 3,3-1,9 4,2 3,3-1,9 6,6 4,7-2,7 ELECTRICAL DATA HYDRAULIC DATA P2 NOMINAL kW HP CAPACITOR μF Vc Q m 3 /h 0 0,6 1,2 1,5 1,8 2,4 3 3,6 4,2 4,5 4,8 6 7,2 9 10,5 l/min 0 10 20 25 30 40 50 60 70 80 80 100 120 150 175 42,7 35 29,2 25,6 22,9 13 47 40 34 30 26,2 23,5 20,3 53,8 47 41 36,3 32,4 28,8 25,8 61 54 47,8 42,8 38,8 20 36,2 33,5 31 28,4 26 24 21,8 19,6 17,5 48,3 45,6 42,8 40 37,6 35 32,5 30 27,2 60,5 58,2 56 53 50 46 43 39,5 38 62 60 58 56 54 51 48,5 46 43,5 39 34,2 41 38 36,5 34 31,8 29,5 27,2 24 21,3 46,5 43,5 41,8 39,2 37 34,2 31,8 28 25 51 49 48 47 44,5 42 40 37 33 29 47 40 34 30 26,2 23,5 20,3 53,8 47 41 36,3 32,4 28,8 25,8 61 54 47,8 42,8 38,8 34,8 20 36,2 33,5 31 28,4 26 24 21,8 19,6 17,5 48,3 45,6 42,8 40 37,6 35 32,5 30 27,2 42,7 35 29,2 25,6 22,9 13 47 40 34 30 26,2 23,5 20,3 53,8 47 41 36,3 32,4 28,8 25,8 36,2 33,5 31 28,4 26 24 21,8 19,6 17,5 48,3 45,6 42,8 40 37,6 35 32,5 30 27,2 Self-priming centrifugal pump with excellent suction capacity even when there are air bubbles. Particularly suitable for water supply in domestic installations, small- scale agriculture, gardening and wherever self- priming operation is necessary. Pump body and motor support in cast iron. Technopolymer impeller, diffuser, Venturi tube and sand guard. Stainless steel adjustment rings. Carbon/ceramic mechanical seal. Asynchronous motor closed and cooled by external ventilation. Built-in thermal and current overload protection and a capa- citor permanently on in the single-phase version. For the protection of the three- phase motor it is advisable to use a suitable overload protection complying with the regulations in force. Operating range: two-poles from 0.4 to 10.5 m 3 /h with head up to 62 metres Liquid temperature range: from 0°c to +35°C for domestic use from 0°C to +40°C for other use Pumped liquid characteristics: clean , free from solids or abrasive substances, not viscous, not aggressive, not crystallised and chemically neutral. Maximum ambient temperature: +40°C Maximum working pressure: 6 bar (600 kPa) for Jet and Jetcom 8 bar (800 kPa) for Jetinox Protection level: IP 44 (IP 55 terminal board protection). Insulation class: F JET JETINOX JETCOM ELECTRICAL AND HYDRAULIC DATA

Upload: others

Post on 22-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: JET - JETINOX - JETCOM...JET 82 Hs 9 8 5 4 3 2 7 6 JET 112 - JETINOX 112 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m3/h 0 40 80 120 160 200 0 0 0 Q l/s Q l/min Q IMP gpm Q US gpm 0 0 0,2 0,4 0,6

®

JET - JETINOX - JETCOMSELF-PRIMING CENTRIFUGAL PUMPS

MODEL

JET 62 MJET 62 TJET 82 MJET 82 TJET 102 MJET 102 TJET 112 MJET 112 TJET 92 MJET 92 TJET 132 MJET 132 TJET 151 MJET 151 TJET 251 MJET 251 TJET 200 MJET 200 TJET 300 MJET 300 TJETINOX 82 MJETINOX 82 TJETINOX 102 MJETINOX 102 TJETINOX 112 MJETINOX 112 TJETINOX 92 MJETINOX 92 TJETINOX 132 MJETINOX 132 TJETCOM 62 MJETCOM 62 TJETCOM 82 MJETCOM 82 TJETCOM 102 MJETCOM 102 TJETCOM 92 MJETCOM 92 TJETCOM 132 MJETCOM 132 T

VOLTAGE50 Hz

P1MAXkW

InA

1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V~3x230-400 V~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~1x220-240 V ~3x230-400 V ~

0,720,670,850,861,131,041,41,350,940,931,491,431,61,62,22,22,02,02,72,7

0,850,861,131,041,41,350,940,931,491,430,720,670,850,861,131,040,940,931,491,43

0,440,440,60,6

0,750,75

11

0,750,75

11

1,11,1

1,851,851,51,52,22,20,60,60,750,75

11

0,750,75

11

0,440,440,60,60,750,750,750,75

11

12,5–

12,5–

16–

25–

14–

25–

31,5–

40–

31,5–

40–

12,5–16–25–14–25–

12,5–

12,5–16–14–25–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

450–

0,60,60,80,811

1,361,36

11

1,361,361,51,52,52,52233

0,80,811

1,361,36

11

1,361,360,60,60,80,81111

1,361,36

H(m)

3,122,1-1,2

3,82,8-1,6

5,13,3-1,9

6,24,3-2,5

4,23,3-1,9

6,64,7-2,7

7,25,2-3

106,9-4

96,8-3,9

128,5-4,9

3,82,8-1,6

5,13,3-1,9

6,24,3-2,5

4,23,3-1,9

6,64,7-2,7

3,122,1-1,2

3,82,8-1,6

5,13,3-1,9

4,23,3-1,9

6,64,7-2,7

ELECTRICAL DATA HYDRAULIC DATAP2

NOMINALkW HP

CAPACITOR

µF Vc

Qm3/h 0 0,6 1,2 1,5 1,8 2,4 3 3,6 4,2 4,5 4,8 6 7,2 9 10,5l/min 0 10 20 25 30 40 50 60 70 80 80 100 120 150 175

42,7 35 29,2 25,6 22,9 13

47 40 34 30 26,2 23,5 20,3

53,8 47 41 36,3 32,4 28,8 25,8

61 54 47,8 42,8 38,8 20

36,2 33,5 31 28,4 26 24 21,8 19,6 17,5

48,3 45,6 42,8 40 37,6 35 32,5 30 27,2

60,5 58,2 56 53 50 46 43 39,5 38

62 60 58 56 54 51 48,5 46 43,5 39 34,2

41 38 36,5 34 31,8 29,5 27,2 24 21,346,5 43,5 41,8 39,2 37 34,2 31,8 28 25

51 49 48 47 44,5 42 40 37 33 29

47 40 34 30 26,2 23,5 20,3

53,8 47 41 36,3 32,4 28,8 25,8

61 54 47,8 42,8 38,8 34,8 20

36,2 33,5 31 28,4 26 24 21,8 19,6 17,5

48,3 45,6 42,8 40 37,6 35 32,5 30 27,2

42,7 35 29,2 25,6 22,9 13

47 40 34 30 26,2 23,5 20,3

53,8 47 41 36,3 32,4 28,8 25,8

36,2 33,5 31 28,4 26 24 21,8 19,6 17,5

48,3 45,6 42,8 40 37,6 35 32,5 30 27,2

Self-priming centrifugal pump with excellent suction capacity even when there areair bubbles. Particularly suitable for water supply in domestic installations, small-scale agriculture, gardening and wherever self- priming operation is necessary.Pump body and motor support in cast iron. Technopolymer impeller, diffuser,Venturi tube and sand guard. Stainless steel adjustment rings.Carbon/ceramic mechanical seal. Asynchronous motor closed and cooled byexternal ventilation. Built-in thermal and current overload protection and a capa-citor permanently on in the single-phase version. For the protection of the three-phase motor it is advisableto use a suitable overload protection complying with the regulations in force.

Operating range: two-poles from 0.4 to 10.5 m3/h with head up to 62 metresLiquid temperature range: from 0°c to +35°C for domestic use

from 0°C to +40°C for other usePumped liquid characteristics: clean , free from solids or abrasive substances,not viscous, not aggressive, not crystallised and chemically neutral.Maximum ambient temperature: +40°CMaximum working pressure: 6 bar (600 kPa) for Jet and Jetcom

8 bar (800 kPa) for JetinoxProtection level: IP 44 (IP 55 terminal board protection).Insulation class: F

JET

JETINOX

JETCOM

ELECTRICAL AND HYDRAULIC DATA

Page 2: JET - JETINOX - JETCOM...JET 82 Hs 9 8 5 4 3 2 7 6 JET 112 - JETINOX 112 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m3/h 0 40 80 120 160 200 0 0 0 Q l/s Q l/min Q IMP gpm Q US gpm 0 0 0,2 0,4 0,6

®

JET 82 - JETINOX 82 - JETCOM 82

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40

10

20

30

40

50

0

20

40

60

80

100

120

160

0

0

0

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ftP

kPa

100

200

300

400

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JET 82

Hs 98

5 43 2

7 6

JET 112 - JETINOX 112

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40 0

40

80

120

160

200

0

0

0

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ftP

kPa

10100

20200

30300

40400

50500

60600

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JET 112

87

42

65

3

Hs 9

JET 132 - JETINOX 132 - JETCOM 132

Q m3/h0 1 2 3 4 50 0

20

40

60

80

100

120

140

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

00

0,2 0,4 0,6 0,8 1 1,2 1,410 20 30 40 50 60 70 80 90

Hm H

ftP

kPa

10100

20200

30300

40400

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs8

6

2

75

4 3

JET 132

9

JET 251

Q m3/h0 1 2 3 4 5 6 7 8 90

10

20

30

40

50

60

0

40

80

120

160

200

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

00

0,5 1 1,5 2 2,520 40 60 80 100 120 140

Hm H

ftP

kPa

100

200

300

400

500

600

5 10 15 20 25 30 35 405 10 15 20 25 30

6

2

75

1

3

Hs 8

4

JET 300

JET 62 - JETCOM 62

Q m3/h0 0,5 1 1,5 2 2,5 30

10

20

30

40

0

20

40

60

80

100

120

0

0

0

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8

10 20 30 40 50

Hm

Hft

PkPa

100

200

300

400

2 4 6 8 10 12

2 4 6 8 10

JET 62

8

6 5 42

Hs 9

7

3

JET 102 - JETINOX 102 - JETCOM 102

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40

10

20

30

40

50

0

20

40

60

80

100

120

160

0

0

0

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ftP

kPa

100

200

300

400

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JET 102

Hs 98

7

42

65

3

JET 92 - JETINOX 92 - JETCOM 92

Q m3/h0 1 2 3 4 50 0

20

40

60

80

100

120

140

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

00

0,2 0,4 0,6 0,8 1 1,2 1,410 20 30 40 50 60 70 80 90

Hm H

ftP

kPa

10100

20200

30300

40400

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs8

2

75 4 3

JET 92

9

6

JET 151

Q m3/h0 1 2 3 4 50

10

20

30

40

50

60

0

40

80

120

160

200

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

00

0,2 0,4 0,6 0,8 1 1,2 1,410 20 30 40 50 60 70 80 90

Hm H

ftP

kPa

100

200

300

400

500

600

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs 86

2

75 4

1

3

JET 200

Q m3/h0 1 2 3 4 5 6 7 8 9 10 11 120

10

20

30

40

50

0

20

40

60

80

100

120

160

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

00

0,5 1 1,5 2 2,5 320 40 60 80 100 120 140 160 180 200

Hm H

ftP

kPa

100

200

300

400

5 10 15 20 25 30 35 40 45 505 10 15 20 25 30 35 40

Hs 8 6

3 2

75 4

1

JET 151

JET 62JETCOM 62

JET 102JETINOX 102JETCOM 102

JET 92JETINOX 92JETCOM 92

JET 132JETINOX 132JETCOM 132

JET 112JETINOX 112

JET 82JETINOX 82JETCOM 82

JET 200

JET 300

JET 251

Page 3: JET - JETINOX - JETCOM...JET 82 Hs 9 8 5 4 3 2 7 6 JET 112 - JETINOX 112 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m3/h 0 40 80 120 160 200 0 0 0 Q l/s Q l/min Q IMP gpm Q US gpm 0 0 0,2 0,4 0,6

®

DIMENSIONS AND WEIGHTS

JET 62 395 390 178 108 192 14 111 193 – 144 9 1” G 1” G 470 240 240 0,022 10,5

JET 82 395 395 178 108 192 14 111 193 – 144 9 1” G 1” G 470 240 240 0,022 10,7

JET 102 414 409 178 108 197 14 111 203 – 144 9 1” G 1” G 470 240 240 0,022 12,5

JET 112 414 409 178 108 192 14 111 203 – 144 9 1” G 1” G 470 240 240 0,022 13,5

JET 92 395 390 178 108 192 14 111 193 – 144 9 1” G 1” G 470 240 240 0,022 11,7

JET 132 414 409 263 108 192 14 111 203 – 144 9 1” G 1” G 470 240 240 0,022 13,5

JET 151 558 210 221 350 20 145 11 255 158 – – 1 1/4” G 1 ” G 612 248 279 0,042 31

JET 251 M 632 210 221 350 20 145 11 255 158 – – 1 1/4” G 1 ” G 657 248 279 0,045 35

JET 251 T 558 210 221 350 20 145 11 255 158 – – 1 1/4” G 1 ” G 657 248 279 0,045 31

JET 200 521 214 151 282 20 160 11 227 175 – – 1 1/2” G 1 1/4” G 612 248 279 0,042 27

JET 300 M 595 214 151 282 20 160 11 235 175 – – 1 1/2” G 1 1/4” G 657 248 279 0,045 31,5

JET 300 T 521 214 151 282 20 160 11 227 175 – – 1 1/2” G 1 1/4” G 612 248 279 0,042 27

JETINOX 82 406 174 122 207 14 111 197 – 144 9 – 1” G 1” G 470 240 240 0,027 7,8

JETINOX 102 424 174 122 207 14 111 197 – 144 9 – 1” G 1” G 470 240 240 0,027 9,6

JETINOX 112 424 174 122 207 14 111 197 – 144 9 – 1” G 1” G 470 240 240 0,027 10,6

JETINOX 92 406 174 122 207 14 111 197 – 144 9 – 1” G 1” G 470 240 240 0,027 8,8

JETINOX 132 424 174 122 207 14 111 197 – 144 9 – 1” G 1” G 470 240 240 0,027 10,6

JETCOM 62 406 170 122 208 14 111 198 – 144 9 – 1” G 1” G 470 240 240 0,027 7,5

JETCOM 82 406 170 122 208 14 111 198 – 144 9 – 1” G 1” G 470 240 240 0,027 7,7

JETCOM 102 425 170 122 208 14 111 203 – 144 9 – 1” G 1” G 470 240 240 0,027 9,5

JETCOM 92 425 170 122 208 14 111 203 – 144 9 – 1” G 1” G 470 240 240 0,027 8,7

JETCOM 132 425 170 122 208 14 111 203 – 144 9 – 1” G 1” G 470 240 240 0,027 10,5

MODEL A A1 B C E F G H H1 H3 I Ø DNA DNM L/A L/B H WEIGHTKg

VOLUMEm3

JET 62 - 82 - 102 - 112 - 92 - 132A

A1C

H3

H

E F IGB

JET 200 - 300JET 151 - 251

JETCOMA

C

EF

IGB

DNM

H2

DN

A

H

JETINOXA

C

E F IGB

DNM

DN

AH

2

H