juri albertazzi gildo tomassetti gionatan ruscelli verifica dignostica di isolamento di facciata:...
TRANSCRIPT
![Page 1: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/1.jpg)
Juri Albertazzi
Gildo Tomassetti
Gionatan Ruscelli
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA
BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
![Page 2: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/2.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
NORMATIVA DI RIFERIMENTO
Residenze e Alberghi
Uffici – Edifici commerciali e di
culto
Ospedali Scuole
D2mnTw≥40 dB D2mnTw≥42 dB D2mnTw≥45 dB D2mnTw≥48 dB
DPCM 05/12/97
UNI 11637Classe Residenze – Alberghi -
Uffici – Edifici commerciali e di culto
1 D2mnTw≥43 dB
2 D2mnTw≥40 dB
3 D2mnTw≥37 dB
4 D2mnTw≥32 dB
Prestazione Ospedali eScuole
di base D2mnTw≥38 dB
superiore D2mnTw≥43 dB
![Page 3: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/3.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
RISULTATI COLLAUDI IN OPERA
32
D2mnTw – 8 dB
edificio ad uso residenziale
32
![Page 4: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/4.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
RISULTATI COLLAUDI IN OPERA
32
D2mnTw – 8 dB
Polo chirurgico
37
![Page 5: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/5.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
RISULTATI COLLAUDI IN OPERA
32
D2mnTw – 14 dB
Edificio scolastico
34
![Page 6: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/6.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
POSSIBILI CAUSE MANCATO ISOLAMENTO
Registrazione non ottimale delle ante;
Presenza di elementi accessori che inficiano il complessivo isolamento acustico (griglie ventilazione).
Presenza di elementi con prestazioni acustiche non adeguate;
Montaggio in maniera non corretta di elementi del serramento (controtelaio, telaio, monoblocco);
Chiusura non ermetica di elementi al contorno (ispezione del cassonetto, coprifili, zanzariere).
![Page 7: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/7.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
RISULTATI OTTENUTI A SEGUITO DELLA REGISTRAZIONE DEI SERRAMENTI
Misura-Facciata
Tipologia serramento e muratura - vetro
configurazione
PRIMAD2m,nT,w
[dB]
DOPOD2m,nT,w
[dB]Δ dB
Facciata A
Finestra standard in legno a doppia guarnizione
Muratura Faccia a vista Vetrocamera stratificato 33.1/12/5 – Tapp.
alzate
33 38 + 5
Facciata A
Finestra standard in legno a doppia guarnizione
Muratura Faccia a vistaVetrocamera stratificato 33.1/12/5 – Tapp.
abbassate
39 41 + 2
Facciata B
Porta Finestra in legno a doppia guarnizione
Muratura Faccia a vistaVetrocamera stratificato 33.1/12/5 – Tapp.
alzate
29 40 + 11
Facciata B
Porta Finestra in legno a doppia guarnizione
Muratura Faccia a vistaVetrocamera stratificato 33.1/12/5 – Tapp.
abbassate
35 41 + 6Tipologia intervento: Semplice registrazione delle ante
![Page 8: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/8.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
ALTRI RISULTATI A SEGUITO DI SEMPLICE REGISTRAZIONE
![Page 9: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/9.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
ANALISI TRAMITE SOSTITUZIONE DI ELEMENTI DI FACCIATA
Tipo silenz.
ISOLAMENTOD 2m,nT,w
Silenz A
38
Silenz B
40
Silenz C
42
![Page 10: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/10.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
ANALISI TRAMITE SOSTITUZIONE DI ELEMENTI DI FACCIATA
Tipo griglia
ISOLAMENTOD 2m,nT,w
Config A
38
Config B
41
Config C
37
![Page 11: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/11.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
DIAGNOSTICA DI FACCIATA
Analisi combinata: - isolamento aereo ai rumori di facciata- mappatura acustica- tenuta all’aria ~ rumore
57,0 dB
58,0 dB
59,5 dB58,0 dB
57,5 dB
58,0 dB
57,0 dB58,5 dB
59,5 dB
56,5 dB
55,5 dB
55,0 dB
57,0 dB
![Page 12: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/12.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
DIAGNOSTICA DI FACCIATAIsolamento aereo ai rumori di
facciata
![Page 13: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/13.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
DIAGNOSTICA DI FACCIATAMappatura acustica
![Page 14: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/14.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
DIAGNOSTICA DI FACCIATATenuta all’aria – Blower Door Test
Test eseguito secondo norma UNI EN 13829
![Page 15: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/15.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
DIAGNOSTICA DI FACCIATATenuta all’aria – Blower Door Test
Prova non invasiva e non distruttiva che consente di determinare la permeabilità all’aria dell’involucro edilizio;
Sulla porta di accesso all’alloggio viene posizionato un ventilatore calibrato; la restante superficie della porta rimane impermeabilizzata all’aria con un telo sorretto e premuto contro le guarnizioni da un apposito telaio;
la velocità di rotazione del ventilatore viene impostata per raggiungere e mantenere una differenza di pressione (interno/esterno edificio) pari a 50 Pa, con ambiente interno in depressione;
![Page 16: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/16.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
DIAGNOSTICA DI FACCIATATenuta all’aria – Blower Door Test
Ricerca infiltrazioni d’aria su ampia scala mediante termografia
![Page 17: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/17.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
DIAGNOSTICA DI FACCIATATenuta all’aria – Blower Door Test
Analisi di dettaglio con ricerca infiltrazioni tramite smokepen e quantificazione dell’entità di infiltrazione
aria tramite termoanemometro
![Page 18: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/18.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
PRINCIPALI PUNTI DI INFILTRAZIONE ARIA
![Page 19: Juri Albertazzi Gildo Tomassetti Gionatan Ruscelli VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO](https://reader038.vdocuments.pub/reader038/viewer/2022103016/5542eb5c497959361e8caafc/html5/thumbnails/19.jpg)
VERIFICA DIGNOSTICA DI ISOLAMENTO DI FACCIATA: CASI PRATICI DI CORRELAZIONE TRA BLOWER DOOR TEST E COLLAUDO ACUSTICO DI FACCIATA
CONCLUSIONI
L’analisi congiunta delle tre tipologie di verifica permette:
Per risolvere le problematiche di isolamento di facciata occorre intervenire in maniera puntuale
NON È FACILE RISOLVERE I PROBLEMI MA NEMMENO IMPOSSIBILE!!
di definire con maggiore sicurezza la causa del mancato isolamento per apportare correzioni;
di discriminare carenze correlate a fessurazioni da carenze imputabili all’utilizzo di isolanti non idonei;
di fornire utili indicazioni a progettisti e serramentisti per migliorare prodotti e posa.