kapak sayfasi 01 ing - delta gci - general catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk...

12
ELEKTRİK E KX E KB E KO E MK E KAP E DL E KAM E DK E DKY E UK LINE LINE LINE LINE LINE LINE LINE LINE LINE LINE Compact Busbar Distribution System 630...6300A Compact Busbar Distribution System 800...6300A Plug-in Busbar Distribution System 160...800A Small Power Plug-in Busbar Distribution System 100-160-225A Plug-in Busbar Distribution System 40-63A Multi-conductor Lighting Busbar System 25-32-40A Lighting Busbar System 25-32-40A Underfloor Ducting Systems Raised Floor Energy Distribution Systems 25...63A Cable Tray Systems

Upload: vuliem

Post on 03-Jul-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

E L E K T R İ K

E KXE KBE KOE MKE KAPE DLE KAME DKE DKYE UK

LINELINELINELINELINELINELINELINELINELINE

Compact Busbar Distribution System 630...6300ACompact Busbar Distribution System 800...6300APlug-in Busbar Distribution System 160...800ASmall Power Plug-in Busbar Distribution System 100-160-225APlug-in Busbar Distribution System 40-63AMulti-conductor Lighting Busbar System 25-32-40ALighting Busbar System 25-32-40AUnderfloor Ducting SystemsRaised Floor Energy Distribution Systems 25...63ACable Tray Systems

Page 2: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

Features;Epoxy insulation

Fire resistance as per IEC 60331

Epoxy polyester, RAL 7038, painted extruded aluminium housing

Tin plated aluminium and copper conductors

4, 4 or 5 conductors

IP 55

Ready-made standard components

Ability to supply energy either from the joints or from the tap-off points

High electrical and mechanical endurance

Fast, easy and reliable installation by one bolt joint construction

Low voltage drop

Lower total installed cost

Compact structure

1/2

The perfect design for high current busbar systems is the

compact structure where tin plated, insulated conductors are

tightly placed into the sheet metal housing. The compact

structure is reliable, robust and functional.

Applications:Airports

All Industrial Premises

High Rise Buildings

Textile Industry

Automobile Industry

Hotels

Shopping Malls

As main energy transportation and distribution

system on horizontal and vertical runs.

Compact Busbar Distribution System630 A...6300A

E KXLINE

E KXLINE

3

2

1

-

800

-

1000

1250

1350

-

1600

2000

-

-

2500

-

-

3200

4000

5000

-

08

-

10

12

14

-

17

20

-

-

25

-

-

33

40

50

Aluminium (Al)

RatedCurrent

RatedCurrent

BusbarCode

BusbarCode

(mm)

91

106

121

131

161

176

191

211

251

202

252

312

342

372

412

492

732

Copper (Cu)

800

100

1250

1350

1600

-

200

-

2500

2000

2500

3150

3600

3900

4250

5000

6300

08

10

12

14

16

-

20

-

25

22

26

32

36

39

43

50

63

A

Page 3: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

* New Product group

3

2

1

800

1000

1250

1600

1600

2000

2500

3050

3100

4000

4250

5000

*

*

*

*

*

*

*

130

155

185

215

250

300

360

420

445

535

625

710

08

10

12

13

16

20

25

27

30

40

41

50

Aluminium (Al) A

RatedCurrent

RatedCurrent

BusbarCode

BusbarCode

(mm) (mm)

130

155

185

215

250

300

360

420

445

535

625

-

130

Copper (Cu)

1000

1250

1600

2000

2250

2500

3000

3600

4250

4400

5300

6300

-

10

12

16

20

23

25

30

36

42

44

53

63

-

A

E KBLINE

Features;3 phase 4 wire, 3 phase 4,5 wire and

3 phase 5 wire conductor options

Tap off boxes can be installed to

plug-in points or to bolt-on joints

Robust structure

High short circuit endurance

One bolt joint construction which ensures

quick and safe installation

Continuously tin plated aluminum or copper conductors

IP 55 protection degree

Multi layer insulation, Clean earth option

All ratings tested according to IEC 60439-2

The perfect design for high current busbar systems is the

compact structure where tin plated, insulated conductors are

tightly placed into the sheet metal housing. The compact

structure is reliable, robust and functional.

Applications:All Industrial Premises

High Rise Buildings

Textile Industry

Automobile Industry

Hotels

Shopping Malls

As main energy transportation and distribution

system on horizontal and vertical runs.

Compact Busbar Distribution System800 A...6300A

Page 4: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

Features;3 phase 4 wire, 3 phase 4,5 wire and

3 phase 5 wire conductor options

Tap off points at every 25 cm.

Continuously tin plated aluminum or copper conductors

Sealable tap off points

Block joint

IP 55 Protection level

All ratings tested according to IEC 60439-2

Polarity mechanism on the joints ensures

correct mounting of the phases

KO-II Busbar system transports and distributes energy between

160 and 800A both vertically and horizontally. Tap off points

that are equipped with shutters are reliable and functional.

Applications:Textile Industry

All industrial premises where there

is frequent need for tap off points

Automotive Industry

Workshops

High Rise Buildings

Shopping Malls

Plug-in Busbar Distribution System160A...800A

Current Copper(Cu)Aluminium(Al)

(A) (A)

mm

(A)

mm

A

180

L1

L2

L3

N

PE

-

70

75

80

-

100

125

70

75

80

100

112

125

-

160

250

315

400

500

630

800

625 500

500375 500 500

3000

500 625

500 500 500 375

E KO-LINE

Page 5: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

E MKLINE

Features;4 and 5 conductors

Clean earth conductor configuration

Continuously tin plated aluminum or copper conductors

Block joint

Tap off points at every 25cm

Hinged plug-in point IP covers

Flexible, multi functional elbows

IP 55 protection level

All ratings tested according to IEC 60439-2

MK busbar system is designed to distribute

electrical energy between 100 and 225 A in

horizontal and vertical runs.

Applications:Textile Industry

Automobile Industry

Industrial Premises

Workshops

Shopping Malls

High Rise Buildings

Small Power Busbar Distribution Systems100-160-225A

Block joint easy and fast installation

50

115

N

L1

L2

L3

PE

3000385 500 500 500 500 615

385500500500500615

Page 6: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

L1 L1

L2 L2

L3 L3

N N

CPE CPE

E DLLINE

Features;Maximum number of conductors : 10

Clean earth and double neutral wiring configurations available

Continuously tin plated electrolytic copper conductors

Hinged plug-in point IP protection covers

IP 55 protection degree

Jawed tap off contacts

Plug-in points at every 75cm

Robust structure

Tap off plugs with phase indicators

Continuously insulated conductors

All ratings tested according to IEC 60439-2

DL lighting busbar is a multi conductor system which can be

configured with more than one circuit. Utility and emergency

lighting power supply can be distributed using only one busbar run.

Applications:Warehouses

Workshops

Car Parks

Supermarkets

Shopping Malls

Raised Floor Applications

Multi-Conductor Lighting Busbar System25-32-40A

DL

34

54

3000

330

330

750

750 750 750

750 750 420

420

DL 16 FSDL 16 K

DL 25 - S

DL 10 B

Page 7: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

E KAMLINE

Features;Ease of project design

Quick, easy and reliable mounting

5th conductor option

Plugs with phase indication

Robust construction

Tap-off points at every 75 cm

IP 55

KAM group is specifically designed as lighting busbar system

due to the specifications of its tap off plugs.

Lighting Busbar System25-32-40A

3000

7500 0 0 0

750 750375 375

KAM

L3

L2

L1

35

55

N

Applications:Warehouses

Workshops

Car Parks

Supermarkets

Shopping Malls

All Industrial Premises

KAM 10 B

KAM 16 FSKAM 16 K

Page 8: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

E KAPLINE

Features;Electrolytic copper conductors are continuously tin plated and

insulated along their full length. (Except tap-off positions) with

a self extinquishing plastic sleeve.

Quick, easy and reliable mounting.

5th conductor option.

Plugs with phase indication

Tap-off plugs and boxes; are designed to prevent improper use

of busbar.

Silver-plated joint contacts are designed to minimise joint contact

resistance.

Tap-off points at every 75cm.

KAP busbar trunking system is designed to be used for

applications where there is frequent need of energy supply

from 40A upto 63A

Applications:Workshops

Business centres

Industrial premises

Plug-in Busbar System40-63A

3000

7500 0 0 0

750 750375 375

KAP

L1

L2

L3

35

55

N

KAP 16 FSKAP 16 K

KAP 32 KAP 32 FS

Page 9: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

E DKLINE

E DKYLINE

Features;Easy Planning

Possibility of multiple outlet

Easy and quick cable ducting

Robust construction

User friendly design

Reliable cable management

DK Underfloor Ducting System is a modular and modern cable

management system that brings solution for any changes in

connection with wiring at the time of installation or in future,

and thus proves to be a good support to meet any requirement

that may rise during operation. DK Underfloor Ducting System

ensures an aesthetic, safe and reliable cable management by

eliminating the wiring related confusion caused in working

environments.

Applications:Banks

Shopping Malls

Offices

Hotels

Hospitals

Conference Halls

Underfloor Cable Management Systems

Raised Floor EnergyDistribution Systems25-63A

Alum Height 70 - 110 mm.

Page 10: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

E UKLINE

Features;3 m standard lengths, with an option of upto

6 m standard lengths

Pre-galvanized or hot dipped galvanized systems

Epoxy, epoxy polyester and polyester coating options

Wide variety of accessories

Special die formed ladder tray application

Easy and quick installation

Fast delivery in large quantities

EAE Cable management systems are designed with a large

variety of accessories which ensures systems adaptability to

any kind of building structure with pre fabricated modules.

Applications:Industrial Premises

High Rise Buildings

Textile Industry

Shopping Malls

Warehouses

Automotive Industry

Similar Premises

Cable Tray Systems \ Ladder Tray SystemsCable Ladder Systems \ U channels \ Piping SystemsSuspensions and Support Systems \ Accessories

A

T H

UKS Cable Trays

UMK Ladder Trays

CTH Light Duty Cable Trays

CTA Heavy Duty Cable Trays

UKK Covers

CTK Covers

KMH Light Duty Cable Ladder

KMA Heavy Duty Cable Ladder

Product Type Height (H) Width (A)

40/50/60/75/100

40 / 50 / 60

60

40/50/60/75/100

10

10

40/50/60/75/100

40/50/60/75/100

50

0

50

0

0

10

50

50

50

10

10

÷ 500

÷ 500

÷ 600

÷ 600

÷ 500

÷ 600

÷ 600

÷ 600

P= (TS 822) DIN EN 17162Pre-galvanized

S= (TS 914) DIN 50976Hot Dip

P+B=Paint on pre-galvanized

S+B=Paint on hot dip

3000 mm standard lengths

Page 11: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

Busbar systems are designed to solve electrical distribution

problems in buildings like factories, workshops, sky scrapers,

shopping and business centres.

E-Line Busbars are easily adapted to the growing needs of

all premises.

System components can be added, deleted or relocated

after initial installation.

The power supply can be adapted to different production

processes simply by relocating the tap-off units.

GENERALFEATURES

GENERALFEATURES

KX - KB

KO - KB KO - KB

KO - KB MK

KO - KB KAM - KAP

KO - KB TB

Modern Outlook

Economy

Flexibility

Long Life

Other than their functional advantages E-Line Busbar Systems

also create a modern outlook to buildings where they are used.

It reduces the total installed cost by replacing cables and

cable trays, by minimizing the panel-board dimensions and by

reducing the installation labour cost.

Tap-off points at short intervals make electrical power available

in all locations; the power supply can be adapted to different

processes simply by relocating the tap-off unit.

Busbar components, can be added, deleted or relocated after

the initial installation, saving time and money.

E-Line Busbar Systems are maintenance free. Every component

of the system is manufactured in a modular structure. When

necessary the whole electrical supply system can be reinstalled

at a different location.

When using E-Line Busbar Systems the power supply

system can be engineered at an early stage, even

before the final disposition of loads is known.

E-Line busbar systems feature every necessary

component as a prefabricated unit and they are

ready to be installed.

Power is quickly supplied to the loads. No expertise

is necessary for the installation of the system.

All necessary support and fitting elements are

manufactured items.

E-Line Busbar Systems increase personnel

safety with their special design.

Ease At Planing

Fast and Easy Installation

Reliable Energy Transportation &Distribution

Page 12: kapak sayfasi 01 ing - Delta GCI - General Catalog.pdf · ekb eko emk e kap edl e kam edk e dky euk line line line line line line line line ... catalogue 02-eng. / rev 02 1.500 pcs

Akcaburgaz Mahallesi,

119. Sokak No: 10 34510

Esenyurt / ISTANBUL / TURKIYE

Tel : +90 (212) 866 20 00 (pbx)

Fax: +90 (212) 886 24 20

www.eae.com.tr

T E

ME 04

IEC 60439-2 s

ATA

MA

TB

AA

CIL

IK /

61

2 4

0 6

6C

ata

log

ue

02-E

ng

. /

Re

v 0

2

1.5

00 P

cs

20/1

0/2

009

ISO9001

14001

QUALIT

YA

ND

ENVI

RONMENTAL MANAGEM

EN

TS

YSTEM

S

EA

Ea t

ou

t le

dro

it d

’ap

po

rter

des m

od

ific

atio

ns o

u d

es c

han

gem

en

ts à

ce c

ata

log

ue s

an

s p

réavis

.