SLIP POWER RECOVERY SYSTEM

Prepared By:-• Kaushal Boghani(130760109002).• Kishan Patel(130760109013).Guided By:-• Prof. Keyur Denpiya.

Page 2: KAUSHAL BOGHNAI

Slip power recovery

• Instead of wasting the slip power in the rotor circuit resistance, a better approach is to convert it to ac line power and return it back to the line. Two types of converter provide this approach:

1) Static Kramer Drive - only allows operation at sub-synchronous speed. 2) Static Scherbius Drive - allows operation above and below synchronous speed

Page 3: KAUSHAL BOGHNAI

Conventional kramer system

Page 4: KAUSHAL BOGHNAI

Conventional kramer system• In this method, the speed of an induction motor is controlled

by injecting a voltage in the rotor circuit • The injected voltage to have same frequency as the slip

frequency• When we insert a voltage which is in phase opposition to

induced rotor emf,it amounts to increasing the rotor resistance

• When we insert a voltage which is in phase to induced rotor emf, its equivalent to decreasing the rotor resistance

• Hence by changing of injected emf and the rotor resistance, the speed can be controlled

Page 5: KAUSHAL BOGHNAI

ADVANTAGES 1.Any speed within the working range can be obtained,

instead of only two or three as with other methods2.If the rotor converter is over excited, it will take a lead

current which compensates the lagging current drawn by the main motor hence improves the pf of the system

Page 6: KAUSHAL BOGHNAI

Static kramer system

Page 7: KAUSHAL BOGHNAI

• At zero speed (s=1) the motor acts as a transformer and all the real power is transferred back to the line (neglecting losses). The motor and inverter only consume reactive power.

• At synchronous speed (s=0) the power factor is the lowest and increases as slip increases. The PF can be improved close to synchronous speed by using a step-down transformer. The inverter line current is reduced by the transformer turns ratio -> reduced PF.

Page 8: KAUSHAL BOGHNAI

AC Equivalent Circuit of Static Kramer Drive

Page 9: KAUSHAL BOGHNAI

Modified kramer system

Page 10: KAUSHAL BOGHNAI

Static Scherbius Drive

Page 11: KAUSHAL BOGHNAI

Static Scherbius Drive Equation

Page 12: KAUSHAL BOGHNAI

• Static scherbius drives are capable of bi-directional power flow, with both positive and negative injected voltages possible, in phase with or opposing the rotor current. As a result, a wider set of operating conditions is possible. Considering the torque equation for slip energy recovery: when motoring, torque is positive, when generating torque is negative.

Page 13: KAUSHAL BOGHNAI

Closed loop control of scherbius system

Page 15: KAUSHAL BOGHNAI