무기분석 ICP-MS
ICP
FIMS
유기분석 GC-MS
GC
UV-vis
HPLC
재료물성분석 PSA
TGA
DSC
Video Microscope
환경방사능분석 LSC
Low Background α-β Counting System
Information
contents04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
www.kndt.co.kr 03
KNDT&i Information
KNDT& i04
● 대 표 자 _ 이 의 종
● 설 립 일 _ 1991년 3월
● 종 업 원 _ 약 510명
● 주 소 _ 본사) 서울시 구로구 구로동 170-5 우림e-Biz 센터 805, 806호
화학사업본부 | 기술연구소) 서울시 구로구 구로동 197-5 삼성IT밸리 806, 807호
● 주요업무 _ 물질성분 검사업, 방사선 안전관리, 비파괴검사
케이엔디티앤아이(주)는
정확하고 객관적인 시험검사 연구서비스를 통한
글로벌 전문 시험검사기관입니다.
시험의뢰방법
Process
www.kndt.co.kr 05
시험방법의
유효성확인
시험의뢰 시험접수 샘플링
시료분석 시험방법확인
성적서 발행결과보고 불만사항 접수
케이엔디티앤아이 주식회사 연구소는 1997년 설립이후 화학 및 환경 엔지니어링 분야 설계 및 시공을 전문으로 수행하고 있습니다.
이러한 연구기반을 바탕으로 하여 기술력을 선도하는 벤처기업, INNO-BIZ 기업으로 선정되는 등 기술적 우위성을
인정받고 있습니다.
KNDT& i06
Applications● Environmental : Water quality, Pollution control
● Clinical : Blood, Urine, Serum
● Petrochemistry : Heavy metal and naphtha
ingredient analysis
● Semiconductor : Impurity confirmation of solvent
and water surface analysis
● Atomic energy facility : Radionuclide analysis
(isotope analysis possibility)
● The automobile : Engine oil analysis
● Geochemical
● Agriculture and food
SpecificationsRF generator : 27.12 MHz
RF power : 600-1600 W
Mass analyzer : Quadrupole
Detection limit : ppt-sub ppb level
●
●
●
●
Mass Scan (U238, Pu238)2.058E5
c/s c/s
AMULog Manual Overlay
228.313 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 248.362
1.5E5
100000
50000
0
2.058E5
1.5E5
100000
50000
0
Autoscale Zoom
2 31
Skimmer Cone Vacuum
Shadow StopLens
Figure 5. The ICP-MS interface
Sampler ConeSkimmer Cone Vacuum
Shadow StopLens
Figure 5. The ICP-MS interface
Sampler Cone
Aerosol (fine droplets)
Liquid Sample
Figure 3. Cross-flow nebulizer
ArgonNebulizerFlow
Aerosol (fine droplets)
Liquid Sample
Figure 3. Cross-flow nebulizer
ArgonNebulizerFlow
ICP-MS
ICP-MS | ICP | FIMS
무기분석 | Inductively Coupled Plasma Mass Spectrometer
www.kndt.co.kr 07
ApplicationsEnvironmental : Water, Air, Soil, Waste
Materials : Ceramic, Metal alloy, Plastics
Biological and clinical
Agriculture and food
Geochemical and metallurgical
●
●
●
●
●
P206.236206.104
-2520
cps
wavelength (nm)
25k
0
Zn 206.200
Plasma
Figure 7. Simplified drawing of a basic ICP system
Spectrometer Detector
Inductively Coupled Plasma Spectrometer
ICP-MS | ICP | FIMS
ICP | 무기분석
Microwave Digestion SystemPretreatment equipment●
Plasma
Figure 7. Simplified drawing of a basic ICP system
Spectrometer Detector
KNDT& i
FIMS
ICP-MS | ICP | FIMS
무기분석 | Mercury Analysis System
08
ApplicationsEnvironmental : Water, Air, Soil, Waste
Materials : Ceramic, Metal alloy, Plastics
Biological and clinical
Agriculture and food
Geochemical and metallurgical
●
●
●
●
●
Figure 1. Absorbance signal of sewage sludge sample 2.
0.20
0.15
0.10
0.05
0
0 10 20 30
Time (seconds)
Figure 1. Absorbance signal of sewage sludge sample 2.
0.20
0.15
0.10
0.05
0
0 10 20 30
Time (seconds)
Hg Lamp
Quartz WindowAssembly
Cell Heating 50℃
Cell
Hg Gas
Detector
Figure 2. FIMS optical diagram
Hg Lamp
Quartz WindowAssembly
Cell Heating 50℃
Cell
Hg Gas
Detector
Figure 2. FIMS optical diagram
www.kndt.co.kr 09
Gas Chromatograph Mass Spectrometer
GC-MS | GC | UV-vis | HPLC
GC-MS | 유기분석
ApplicationsAnalysis of organic composition.
(Liquid, Solid, Gas)
Environmental samples.
(Water, Soil, Detergent)
●
●
SpecificationAccessaries : Purge & Trap, Headspace●
1
1
1 2 3
4
5
6
78
9
10
11
1213
1415
16
2 3
4
5 6
7 8
9
1011
1213
14 15
16
2
0 5 10 15 20 25 30 35 min
3
4
5
6
78
9
101112 13
14 15
16Chemical derivatization
Mixture ofVolatilederivatives
GASCHROMATOGRAPH
MASSSPECTROMETER -identity components
Mixture ofchemicalconstituents
GC
GC-MS | GC | UV-vis | HPLC
유기분석 |
KNDT& i
Gas Chromatograph
10
ApplicationsAnalysis of organic composition
(Liquid, Solid, Gas)
Environmental samples
(Water, Soil, Detergent)
●
●
SpecificationDetectors : ECD, NPD, FID, PID●
TCMX_
PCB28_
PCB52_
PCB101_
PCB118_
PCB153_
PCB158_
PCB180_
PCB198_
www.kndt.co.kr 11
UV-Visible Spectrophotometer
GC-MS | GC | UV-vis | HPLC
UV-vis | 유기분석
010100010
010100010
010100010
010100010
010100010
010100010
010100010
010100010
010100010
Inside a UV/VIS Spectrophotometer
Specifications Wavelength range : 190 to 900 nm
Spectral bandwidth : 0.2 mm
Working range : 3.5 Abs
●
●
●
ApplicationsQuantitative analysis of DNA, RNA, Protein and
nucleic acid
Purity(QC)
●
●
HPLC
GC-MS | GC | UV-vis | HPLC
유기분석 |
KNDT& i
High Performance Liquid Chromatograph
12
Application● Analysis of compound protein, Hexane,
Hydrocarbon, Medical supplies, Terpenoid,
Pesticide, Antibiotics, Steroid,
Metal-organic and inorganic
SpecificationsDetector : UV detector (190 ㎚ ~ 600 ㎚)
Wavelength accuracy : 1.0 ㎚
Flow accuracy : <2 %
Maximum operating pressure : 6000 psi
●
●
●
●
ChromatographicProcess
Elution through the Column
BB
B+A
A
A
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00
-47.9704
95.1397
238.2498
381.3598
524.4699
2.11
67
6.01
67
time(min)
volt
age(
mV)
Application● Analysis of compound protein, Hexane,
Hydrocarbon, Medical supplies, Terpenoid,
Pesticide, Antibiotics, Steroid,
Metal-organic and inorganic
www.kndt.co.kr 13
Particle Size Analyzer
PSA | TGA | DSC | Video Microscope
PSA | 재료물성분석
Specifications Measuring range : - 0.02 ~2000 ㎛
Resolution : Results reported in 100 size classes
●
●
Laser
Fourier Lens
Particles Scattering Intensity distribution
Laser Beam
Sample Cell Detectors
1 3 5 7 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51
300
200
150
100
50
0
Data Graph - Light Scattering
Glass beads, 28 January 2003 17:07:41Background data
Detector Number
Lign
tEne
rgy
d(0.5): 42.521 um d(0.9):
Particle Size Distribution
1 10 100 1000 3000
ApplicationParticle size and particle size distribution of
emulsions, Suspensions, Dry Powders and
cosmetics
●
TGA
DSC | TGA | PSA | Video Microscope
재료물성분석 | Thermo Gravimetric Analyzer
14
ApplicationsSolvent | Moisture | Polymer/resin | Filler | Ash
Glass | Carbon black | Evaluation of stabilizers
Loss on drying | Proximate oil analysis
Oxidation studies
●
●
●
●
Balance
SAMPLE
High Temperature Furnace
Purge Gas (oxidizing or inert)
Styrene
Polyester
Fiberglass
CaCO3
0 100 200 300 400 500 600 700 800 900 1000
40
50
60
70
80
90
100
110
4 ℃/min to 900 ℃
SpecificationsTGA furnace: Low-mass furnace with large uniform
temperature zone
Balance capacity: up to 1500 mg
Balance sensitivity: resolution: 0.2 mm
balance accuracy: ± 3 mm | Scan rate: 0.1~100 ℃/min
Tare reproducibillty: < 3 mm | Temp: 20~1000 ℃
Cooling time: With chiller 1000 to 100 ℃ under 10 min
Atmosphere : Static or dynamic, Including nitrogen,
Argon, Helium, Carbon dioxide, Air, Oxygen or other
inert or active gases, Over temperature range
Autosampler: up to 45 samples can be run unattended,
and samples can be added anytime
●
●
●
●
●
●
●
●
KNDT& i
High Temperature Furnace
www.kndt.co.kr 15
Difference Scanning Calorimeter
PSA | TGA | DSC | Video Microscope
DSC | 재료물성분석
ApplicationsGlass transition temperature
Fictive temperature
Curing studies
Melting point and crystallinity studies
Oxidative induction test
Specific heat capacity determination
using DSC
DSC kinetics
●
●
●
●
●
●
●
SpecificationsSensor : Precisely-machined
disc of chromel alloy
Heating Rate : 0.1 to 100 ℃/min
Cooling Rate : 0.1 to 100 ℃/min
Dynamic Range Resolution : ±175 mW
●
●
●
●
0.0
2.0
4.0
6.0
8.0
10.0
150.0 155.0 160.0 165.0 170.0
Temperature(ºC)
Hea
t Flo
w (m
W)
Weight 17.85 mg
Water Circulator
Showing the effect of DSC scanning fate on heat flow curve of an Indium sample
Scan Rate(ºC/min)
Tm Onset(C/min)
Heat of Fusion(J/g)
20.0
10.0
4.0
1.0
0.5
0.2
156.30
156.42
156.50
156.55
156.50
156.53
28.49
28.45
28.40
28.39
28.30
28.35
Epoxy-anhydride System (Totally uncured)
40 60 80 100 120 140 160 180 200 220 240 26728.04
-9.314
-5
0
5
10
15
20
25
3032.23
Uncure epoxy
Peak = 161.548ºC
Area = -9251,368mjDelta H = -362,800J/g
Heat Flux Calorimeter
Sample Reference
Single Heat Source
Video Microscope
DSC | TGA | PSA | Video Microscope
재료물성분석 |
KNDT& i
Video Microscope
16
Applications● Semiconductor : Wafer pattern, Wire bonding,
Channel of semiconductor
● PCB : PCB hole, Soldening, Pattern of whole film
● Fiber : Pattern of fiber matrix
SpecificationsLamp : 12 V / 100 W halogen lamp
Light intensity : 0~100 W
Camera image sensor : 1/3” color CCD
Camera pixel NTSC : 768(H) 494(V)
PAL : 752(H) 582(V)
●
●
●
● ●
●
www.kndt.co.kr 17
Liquid Scintillation Counter
LSC | Low Background α-β Counting System
LSC | 환경방사능분석
Applications● The bionics field which uses form
the radioactive tracer
● The nuclear facility liquid effluence monitoring
● Radiation treatment field
● Environment radioactivity analysis
● Sr-90, CS-137 analysis in
the radioactive substance fallout
● Carbon regiment measurement
● Biosynthesis research (C-14, P-32, P-33)
SpecificationBeta backgrounds: typically 0.4 - 1.2 CPM for H-3
0.5 Bq/L H-3 (5 TU) in 500 min direct counting
●
Counter control
Stop NextCtime
P A C P S A
Window Spectrum
5
1 2 3 4 5 6 7 8 9 10
10
15
20
25
30
35
40
LIVE DISPLAY
Prol: 5Sample: 1Repeat: 1Cycle: 1 Unk measTime: 58.0CPM: 5296.24BETACOUNTS: 5064
Window: 1-1024Y = COUNTS * 1
Start
LSC | Low Background α-β Counting System
Low Background α-β Counting System 환경방사능분석 |
KNDT& i
Low Background α-β Counting System
18
Applications● α,β source and equipment
leakage inspection
● Environment radioactivity
measurement and watch
● Nuclear facility surface measurement and watch
SpecificationsDetector : 2.25” diameter gas-flow
sample detector
Detector window thick : 80 μg/㎠
●
●
To make it beneficial for you.
The most powerful company
for you.
| Inorganic analysis
| Organic analysis
| Material properties analysis
| Environmental radioactivity analysis
www.kndt.co.kr 19
Low Background α-β Counting System 환경방사능분석 |
KNDT&i Information
Creative company with infinite potential
레미안
케이엔디티앤아이 주식회사(본사)
케이엔디티앤아이 주식회사·화학사업본부·기술연구소
서울시 구로구 구로동 197-5번지 삼성 IT밸리 806, 807호
152-050 # 806 Samsung IT Valley 197-5, Guro-dong Guro-gu Seoul, Korea
Tel: 02-2028-2163~4 Fax: 02-2028-2165
www.kndt.co.kr
Creative company with infinite potential 케이엔디티앤아이 주식회사 / 화학사업본부 / 기술연구소
서울시 구로구 구로동 197-5 삼성IT밸리 806, 807호
# 806 Samsung IT Valley 197-5, Guro-dong Guro-gu Seoul, Korea
Tel: 02-2028-2163~4 Fax: 02-2028-2165
www.kndt.co.kr
| Inorganic analysis | Organic analysis | Material physical properties analysis | Environmental radioactivity analysis
KNDT&i