kubota vertical mixed flow volute pump ds-vvkubota vertical mixed flow volute pump ds-vv sc4160...

4
KUBOTA Vertical Mixed Flow Volute Pump DS-VV SC4160 2015.3.0.1 KES.KES PUMPS CATALOGUE Hirakata Plant 1-1-1, Nakamiya-Oike, Hirakata-city, Osaka 573-8573, Japan Phone: 072-890-2228 Facsimile: 072-840-1413 KUBOTA Corporation DOMESTIC OFFICES AND OVERSEAS OFFICES E-Mail:[email protected] http://www.kubota-pump.com/english/ Tokyo Office 1-3, Kyobashi, 2-chome, Chuo-ku, Tokyo 104-8307 Japan Phone: +81-3-3245-3228 Facsimile: +81-3-3245-3830 Kubota Corporation Philippine Office 232 Quirino Highway, Baesa, 1106 Quezon City, Metro Manila, Philippines Phone: +63-2410-2428 Facsimile: +63-2410-2428 Anhui Kubota Sanlian Pump Co.,Ltd. He Xian County Economic Development Zone in Anhui Province, China Phone: +86-565-5338018 Facsimile: +86-565-5338020 Post Code: 238200 Overseas Offices: Kubota Corporation Bangkok Office 25th Floor, Serm-Mit Tower, 159 Sukhumvit 21 Road, Wattana, Bangkok 10110, Thailand Phone: +66-2260-6590 Facsimile: +66-2260-6589 Kubota Corporation Malaysia Branch 801A, 8th Floor, Amcorp Tower, Amcorp Trade Center, No.18, Jalan Persiaran Barat 46050 Petaling Jaya, Selangor Darul Ehsan, Malaysia Phone: +60-3-7954-2334 Facsimile: +60-3-7954-1335 Kubota Corporation Dubai Branch Office No. LB180508 & LB180509 Jafza View 18, Jebel Ali Free Zone P.O.Box 17440, Dubai, UAE Phone: +971-4-885-7033 Facsimile: +971-4-885-7032 Domestic Offices: KUBOTA reserves the right to change the design, technical specification and dimensions without prior notice.

Upload: others

Post on 26-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: KUBOTA Vertical Mixed Flow Volute Pump DS-VVKUBOTA Vertical Mixed Flow Volute Pump DS-VV SC4160 2015.3.0.1 KES.KES PUMPS CATALOGUE Hirakata Plant 1-1-1, Nakamiya-Oike, Hirakata-city,

KUBOTAVertical Mixed Flow Volute Pump

DS-VV

SC41602015.3.0.1 KES.KES

PUMPS CATALOGUE

Hirakata Plant1-1-1, Nakamiya-Oike, Hirakata-city,Osaka 573-8573, Japan Phone: 072-890-2228 Facsimile: 072-840-1413

KUBOTA CorporationDOMESTIC OFFICES AND OVERSEAS OFFICES

■E-Mail:[email protected]■http://www.kubota-pump.com/english/

Tokyo Office1-3, Kyobashi, 2-chome, Chuo-ku,Tokyo 104-8307 Japan Phone: +81-3-3245-3228 Facsimile: +81-3-3245-3830

Kubota Corporation Philippine Office232 Quirino Highway, Baesa, 1106 Quezon City, Metro Manila, PhilippinesPhone: +63-2410-2428Facsimile: +63-2410-2428 Anhui Kubota Sanlian Pump Co.,Ltd.He Xian County Economic Development Zone in AnhuiProvince, ChinaPhone: +86-565-5338018Facsimile: +86-565-5338020Post Code: 238200

Overseas Offices:Kubota Corporation Bangkok Office25th Floor, Serm-Mit Tower, 159 Sukhumvit 21 Road,Wattana, Bangkok 10110, Thailand Phone: +66-2260-6590Facsimile: +66-2260-6589

Kubota Corporation Malaysia Branch801A, 8th Floor, Amcorp Tower, Amcorp Trade Center,No.18, Jalan Persiaran Barat 46050 Petaling Jaya,Selangor Darul Ehsan, MalaysiaPhone: +60-3-7954-2334Facsimile: +60-3-7954-1335

Kubota Corporation Dubai BranchOffice No. LB180508 & LB180509 Jafza View 18, Jebel Ali Free Zone P.O.Box 17440, Dubai, UAE Phone: +971-4-885-7033Facsimile: +971-4-885-7032

Domestic Offices:

KUBOTA reserves the right to change the design,technical specification and dimensions without prior notice.

Page 2: KUBOTA Vertical Mixed Flow Volute Pump DS-VVKUBOTA Vertical Mixed Flow Volute Pump DS-VV SC4160 2015.3.0.1 KES.KES PUMPS CATALOGUE Hirakata Plant 1-1-1, Nakamiya-Oike, Hirakata-city,

●Suction bore: 400mm~1500mm●Capacity: 12m3/min~320m3/min●Total Head: 40m~150m

Product Range

Application

High Efficiency2

Large Solid Passing Size3

High head has been achieved to follow trend design for sewage plant.

Higher efficiency has been achieved using the latest hydraulic design.

Advanced silent and low vibration designare adopted using latest CFD analisis.

In order to prevent clogging, advanced non clogging impeller and casing are applied, and No.of Vanes are minimized.

Large capacity has been achieved.up to 320 m3/min. (more than standard capacity can be produced)

High Head1

Large Capacity

Silent and low vibration5

Features

4

Best Suitable Design for Sewage

■Pump specification

■Standard MaterialMaterialParts name JIS code

Ductile Cast Iron

Stainless Steel CastingStainless Steel

Stainless Steel CastingStainless Steel Casting

Casing

ImpellerShaft

Impeller RingCasing Ring

FCD450 Gr65-45-12

SCS6SUS420J2

SCS6SCS14

ASTM code

CA6NMA318 S42000

CA6NMCF-8

・Sewerage: Rain water drainage, Sewage transfer.・Agriculture Irrigation and Drainage.・Water Work: Water intake, boosting, Distribution.

Liquid Liquid temperature Suction Pressure Flange Bearing Bearing Lubrication Shaft Seal Paint Rotating direction

Sewage0℃~80℃Max 0.3MPaSuction: ISO PN10Discharge: ISO PN10 16Ball, RollerGrease, OilNon flushing mechanical sealInternal Epoxy resin paint for water serviceExternal: Epoxy Resin PaintClockwise viewed from top

2 3

Page 3: KUBOTA Vertical Mixed Flow Volute Pump DS-VVKUBOTA Vertical Mixed Flow Volute Pump DS-VV SC4160 2015.3.0.1 KES.KES PUMPS CATALOGUE Hirakata Plant 1-1-1, Nakamiya-Oike, Hirakata-city,

Upper bearing・Self-aligning roller bearing.・Cooling fan is applied to large product.・Ball bearing is available to small product.・Axial thrust is supported.

Lower bearing

・Grease lubricated ball bearing.・Oil lubricated is available to large product.

Motor pedestal

・Motor pedestal and pump casing can be integral design to create a compact space.

Shaft Seal

・Non flusing mechanical seal is applied.・Gland packing can be designed.

Impeller Boss・Back-Swept impeller is applied, so that Impeller boss is sweptback to acquire large solid passing size.

Impeller

・Open type is appplied.・Close type is available.・Number of vanes are minimized.

Capacity(m3/min)

Capacity(m3/min)

160

80

40

20

10

5

160

80

40

20

10

5

5 10 20 40 80 160 320 640 1280 2560

5 10 20 40 80 160 320 640 1280 2560

4 5

Best Suitable Design for Sewage Selection Chart

Tota

l Hea

d(m

) 

■Selection Chart - 60Hz

■Selection Chart - 50Hz

Tota

l Hea

d(m

) 

400

450

500 / 600700 800 1000

900

400

450

500600 700

800

900

1000 1200

400

450

500

600

700

800900

1000

1200

1400

400

450

500

600

700

800900

1000 1200

1400

400

450

500

600 / 700 800 1000

900

400

450

500

600 700800

900

10001200

400

450

500

600

700

800

900

1000

1200

1400

400

450

500

600

700

800

900

1000 1200

1400

Dotted range & abovecan be designed.

Dotted range & abovecan be designed.

Page 4: KUBOTA Vertical Mixed Flow Volute Pump DS-VVKUBOTA Vertical Mixed Flow Volute Pump DS-VV SC4160 2015.3.0.1 KES.KES PUMPS CATALOGUE Hirakata Plant 1-1-1, Nakamiya-Oike, Hirakata-city,

Changi Water Reclamation Plant

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

Singapore

1200 mm

278 m3/min

59 m

3500 kW

10 sets

Jahra Pumping Station

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

Kuwait

700 mm

1086 l/s

120 m

1750 kW

6 sets

HEET Pump Station

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

Saudi Arabia

450 mm

1041.7 m3/hr

80 m

400 kW

8 sets

Harbour Area Treatment Scheme 2

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

Hong Kong

1200 mm

4.0 m3/s

42.5 m

2250 kW

8 sets

MPS-1

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

UAE

600 mm

685 l/s

40.2 m

410 kW

8 sets

PS32A Pumping Station

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

QATAR

500 mm

680 l/s

70 m

670 kW

4 sets

North Jeddah

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

Saudi Arabia

900 mm

132 m3/min

73 m

2350 kW

8 sets

Zhong Zhou Sewage Treatment

Country

Suction Bore

Capacity

Total Head

Motor Output

Quantity

Taiwan

1200 mm

165 m3/min

45 m

1650 kW

5 sets

6 7