kvn/kava/eavn현황 · 2020. 8. 12. · •4 adc (4 x 16gsps) • input freq. 8 -16ghz • digital...

15
KVN/KaVA/EAVN 현황 Taehyun Jung (KASI) On behalf of KVN TEAM 2020 전파망원경 사용자회의 (8월 13일)

Upload: others

Post on 16-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

KVN/KaVA/EAVN 현황

Taehyun Jung (KASI)

On behalf of KVN TEAM

2020 전파망원경 사용자회의 (8월 13일)

Page 2: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

Radio Telescope User’s Meeting 2020 (Aug 13, 2020)

Korean VLBI Network (KVN)

• 3 Telescopes (D = 21m)

• 22/43/86/129GHz

• 300 - 500 km

• 𝚯 = 1 - 6 mas

• Science Targets

AGN/SF/Evolved Star

+ microquasar

2

Yonsei

Tamna

Ulsan

θHBPW ~ 6 mas @ 22 GHz~ 1 mas @ 129 GHz

Page 3: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

EAVN Status

Up to 16 radio telescopes (KOR 4, CHA 5, JAPAN 10)Observing frequency: 6.7GHz (11), 8GHz (14), 22GHz(15), 43GHz(11)Angular resolutions: 2.4 / 1.5 / 0.6 / 0.3 mas @ 6.7 / 8 / 22 / 43 GHzSensitivity (7-sigma detection, t_int = 60s, BW = 256 MHz)- 1.6 mJy @ 8GHz & 9.5 mJy @ 22GHz (Tianma-KVN)

Page 4: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

VERA’s budget crisis

Severe budget cut was expected for 2020Bà 2020B Call for Proposals : KaVA 4 stations only (KVN+Mizusawa)However, VERA will fully participate to KaVA/EAVN observation until 2021 MarchVERA is trying to make a long-term plan for future operation

Page 5: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

KVN/EAVN Operation Statistics 2019B/2020A

관측시즌 총관측수 총관측시간Cancel/ Fail

2019B 157 1606 73 / 0

2020A 265 1977 207 / 5

2019B Error Count KYS KUS KTN SUMAntenna control failure 2 18 4 24

Recording error 4 7 11 22Severe weather condition 10 7 15 32

Other problems 12 58 12 82Sum 28 90 42 160

2020A Error Count KYS KUS KTN SUMAntenna control failure 0 17 9 26

Recording error 9 5 3 17Severe weather condition 15 16 31 62

Other problems 59 83 24 166Sum 83 121 67 271

Other problems : mostly due to VFC and AWS (KUS)

Page 6: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

KVN/EAVN Operation Status (2019)• VLBI ~ 3300h/yr & SD ~ 600h/yr• KVN Only ~ 1800h• KaVA (KVN and VERA Array) ~ 700h • EAVN/EVN/GMVA/Sejong ~ 800h

• KVN Key Science Projects : 1400h/yr• Evolved Star(1) & AGN (2)

• KaVA/EAVN Large Programs : 300h/yr• AGN, Star formation, Evolved stars, Galactic

astrometry

• Global Common Use : 1000h/yr• KVN(500h/yr) + KaVA/EAVN (500h/yr)

• Proposals status• 2018B: KVN(16), KaVA/ EAVN (15)• 2019A: KVN (12), KaVA/ EAVN (19)• 2019B: KVN (9), KaVA/EAVN (24)• 2020A: KVN (8), KaVA/EAVN(19)• 2020B: KVN (4), KaVA/EAVN(12)

• Total 135 refereed papers were published (since 2013)Toal 106 SCI papers (14 SCI papers/yr)

Page 7: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

Radio Telescope User’s Meeting 2020 (Aug 13, 2020)

KVN System Upgrade: Receiver

KVN Receiver Freq. (old) Freq. (new) Trx (new) Installation

K-band 21.24 - 23.25 18 - 26 < 40Completed in ’18(all KVN stations)

Q-band 42.10 - 44.10 35 - 50 < 50KYS (’19)KUS (’21)

KTN (’20 Aug)

W-band 85 - 95 85 - 116 < 80KYS (’19)KUS (’18)

KTN (’20 Sep)

D-band 125 - 142 125 - 172 < 60 ’23 ~

• Upgrade current Rx by replacing narrow band components~ LNA, Feed Horn, Polarizer, tunable LO etc

• Instantaneous Bandwidth = 8GHz

Page 8: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

• 4 ADC (4 x 16Gsps) • Input Freq. 8 - 16GHz• Digital Down Conversion• Digital Filtering• 4 x 10GbE output• VDIF format

Bandwidth(MHz)

Max Num of

Channels

Max Data Rate (Gbps)

8192 1 32

4096 2 32

2048 4 32

1024 8 32

512 16 32

256 16 16

128 16 8

64 16 4

32 16 2

16 16 1

• Max 16Gbps recording• 4 disk modules with

8 HDDs each• 4 10GbE input

OCTAD

Mark 6

KVN 4-Frequency Full Polarization

K-DAS (4 CH)+ OCTAD (4 CH) or

OCTAD (4 CH) + FILA10G (4 CH)

22 R/L, 43 R/L, 86 R/L, 129 R/LData rate: 1, 2, 4, 8, 16, 32 Gbps

Page 9: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth
Page 10: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

KVN Baseline/Image Sensitivity

• Note: (baseline) / (image) sensitivity in the unit of mJy• When FTP is applied (maximum integration time of 30min & referenced from K),

the expected improvement of baseline sensitivity is more than 2 times better!

Frequency 22 GHz 43 GHz 86 GHz 129 GHz

SEFD (Jy) 1500 1800 3400 5000

Sensitivity (mJy, 1-sigma)

T_int=100s/ T_int=1hr

T_int=60s/ T_int=1hr

T_int=30s/ T_int=1hr

T_int=30s/ T_int=1hr

1 Gbps(Max 256 MHz)

9.6 / 1.28 14.9 / 1.53 39.8 / 2.89 58.5 / 4.25

2 Gbps(Max 512 MHz)

6.8 / 0.90 10.5 / 1.08 28.1 / 2.05 41.3 / 3.01

4 Gbps(Max 1024 MHz)

4.8 / 0.64 7.4 / 0.77 19.9 / 1.45 29.2 / 2.13

8 Gbps(Max 2048 MHz)

3.4 / 0.45 5.3 / 0.54 14.1 / 1.02 20.7 / 1.50

16 Gbps(Max 4096 MHz)

2.4 / 0.32 3.7 / 0.38 9.9 / 0.72 14.6 / 1.06

32 Gbps(Max 8192 MHz)

1.7 / 0.23 2.6 / 0.27 7.0 / 0.51 10.3 / 0.75

Page 11: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

KVN Antenna Position Updates• The accuracy of KVN antenna positions are much improved.

based on Local Survey and KaVA K-band geodesy• Daily antenna positions of KVN is available• Great advantage for VLBI astrometry/geodesy

Example: Daily IVP of KVN Yonsei radio telescope (2015. 1. 1 ~ 2020.12.31)

KVN IVP measured by GPS

Page 12: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

Important Dates and Notes• Summer maintenance: June 20 ~ August 31• 2020B season: 2020 Sep 1 ~ 2021 Jan 15• 2021A Call for Proposals: 2020 mid-September

• 2nd KVN KSP (16Gbps & full polarization, starting from 2020B)- The world’s largest plasma physics study of AGN with KVN (PI: Trippe)- Simultaneous monitoring of SiO and H2O masers toward evolved stars (PI: Yun)à KVN 2nd KSP meeting (Today! 16:00 – 18:00 via zoom)

• EATING VLBI (KVN/EAVN + Italian telescopes)- 30hrs / season (submit proposals to both KVN and Italy)- https://www.radiotelescopes.inaf.it/

• Simultaneous K/Q-band observing capabilities- open for KaVA and/or Yebes- 1Gbps for KaVA + Yebes (max 8 station, K/Q ~128MHz for each frequency)- 4Gbps for Yebes (K/Q ~ 512MHz for each frequency)- Yebes: http://rt40m.oan.es/

• EAVN low frequency VLBI science working group

Page 13: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

KVN Archive DataBaseKVN 데이터 아카이브를 활용한 연구 활성화 : http://data.kasi.re.krà KVN archive

Page 14: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

KVN 중장기 발전계획 (2020~2030)

• 국내외 전파관측시설의 KVN 수신기/광대역 시스템 확보 및 성능 향상(국내) 세종우주측지센터 22m, 서울대6m, TRAO14m(국외) EAVN, 이탈리아(Medicina 32m, Noto 32m, Sardenia 64m),

호주 Mopra 22m, 핀란드 Metsahovi 14m

• 광대역화와 e-VLBI를 통한 고감도/고성능 관측 수행• 2단계 핵심과학연구(KSP2) 운영 및 EAVN 대형과제 관측 지원• EHT와 같은 국제공동연구 활성화, KVN 수신시스템 국제확장을 통한 연구분야 선도

Page 15: KVN/KaVA/EAVN현황 · 2020. 8. 12. · •4 ADC (4 x 16Gsps) • Input Freq. 8 -16GHz • Digital Down Conversion • Digital Filtering • 4 x 10GbE output • VDIF format Bandwidth

Thank you !