lc4f / lct4d€¦ · ul 1598 listed for damp locations dimming forward/reverse phase dimming ......

5
LC4F / LCT4D 4” Fundamentals LED Downlight Alternative Dimming and Emergency Backup FEATURES Lutron and enhanced 0-10V dimming options Single housing design accepts both round and square trims LED LIGHT ENGINE 92 CRI in 2700K and 3000K (Consult factory for other CCT options) 2 SDCM (2-Step MacAdam) 50,000 hours L70 (rated life at 70% output) ELECTRICAL SYSTEM Universal 120/277V input (L2 through L4) This product complies with IEEE C62.41 for surge endurance up to 2.5KV Additional surge protection recommended Damage from power surge is not covered by warranty Lutron Ecosystem 1%/3-Wire/2 wire EldoLED SOLOdrive 0-10V 0.1% EldoLED ECOdrive 0-10V 1% HOUSING 16 gauge galvanized steel 18 gauge galvavized steel flat frame UL 1598 listed for damp locations DIMMING Forward/reverse phase dimming (120V only) 0-10V 1% Dimming EldoLED 0-10V 1% or 0.1% Lutron Tu-Wire 1% TRIM ASSEMBLY Die-cast trim and heat sink assembly with quick connect for easy installation. High optical transparency diffusion lens to obscure LED Wet location listed INSTALLATION L2, L3 and L4 Type IC; rated for direct contact with insulation L5 Type non-IC; insulation should be kept minimum 3” away from all sides of fixture Fixture includes adjustable bar hangers (14”-24”) for wood joist or t-bar ceiling installations Accomodates ceilings with a 1/2” to 1-1/2” thickness Maximum ambient temperature 50°C (122°F) EMERGENCY EM option mounted nearby the fixture above ceiling IOTA PC8 diagram IOTA ILB-CP instruction Manual LISTING Trim Assembly: ETL listed to US and Canadian standards for wet location Can be used to comply with 2016 Title 24 Part 6 - High efficacy LED light source requirements ENERGY STAR ® Qualified JA8-2016 5-Year Intense LED Limited Warranty Trim Assembly Part Number (Example: LCT4DRTW-SF279) Trim Finish CCT/CRI 2 LCT4DRT (Round) LCT4DST (Square) W-SF B-SF SN-SFW (White/Self-Flanged) (Black/Self-Flanged) (Satin Nickel/Self-Flanged/White) 279 309 (2700k/90 CRI) (3000k/90 CRI) Ceiling Cut Out: 4 5/16” octagonal. Maximum Ceiling Thickness: 1 1/2” Frame-In Part Number (Example: LC4FL2ED10V1) Frame-In Wattage Dimming Voltage Options LC4F (Alternate Dimming & Emergency housing) L2 L3 L4 L5 1 (8 Watts) (10 Watts) (12 Watts) (16 Watts) LUT LUT2 ED10V1 ED10V01 D101 ELV (Lutron Ecosystem 1%) (Lutron Tu-Wire phase 1%) (eldoLED 0-10V 1%) (eldoLED 0-10V 0.1%) (0-10V Dimming 1%) (Phase Dimming) blank 27 (120V) (277V) EM7 (7W Emergency Backup IOTA part #ILB-CP07-A) Note: 1. L5 not IC rated 2. Consult factory for other CCT options ELECTRICAL DATA LED Light Engine System Wattage * CCT / CRI Nominal Delivered Lumens ** Round Square L2 L3 L4 L5 8W 10W 12W 16W 2700K/3000K / 92 CRI 2700K/3000K / 92 CRI 2700K/3000K / 92 CRI 2700K/3000K / 92 CRI 600lm 850lm 1000lm 1300lm 500lm 750lm 850lm 1100lm * System Wattage includes driver and LED Module consumption ** Delivered Lumen output will vary depending on CCT, CRI and finish Round Square 4” 5” 2 3/8” 5” 3 3/8” 1 11/ 16” For fire rated housing option, see LC4 Downlight specification JOB NAME CATALOG NUMBER NOTES TYPE FUNDAMENTALS L/M-0521:18 P-6 INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321. © 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Upload: hoangdung

Post on 09-May-2018

236 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: LC4F / LCT4D€¦ · UL 1598 listed for damp locations DIMMING Forward/reverse phase dimming ... insulation L5 Type non-IC; insulation should be kept minimum 3” away

LC4F / LCT4D4” Fundamentals™ LED Downlight Alternative Dimming and Emergency Backup

FEATURES ■ Lutron and enhanced 0-10V dimming options ■ Single housing design accepts both round and square trims

LED LIGHT ENGINE ■ 92 CRI in 2700K and 3000K (Consult factory for other CCT options)

■ 2 SDCM (2-Step MacAdam) ■ 50,000 hours L70 (rated life at 70% output)

ELECTRICAL SYSTEM ■ Universal 120/277V input (L2 through L4) ■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV

■ Additional surge protection recommended ■ Damage from power surge is not covered by warranty ■ Lutron Ecosystem 1%/3-Wire/2 wire ■ EldoLED SOLOdrive 0-10V 0.1% ■ EldoLED ECOdrive 0-10V 1%

HOUSING ■ 16 gauge galvanized steel ■ 18 gauge galvavized steel flat frame ■ UL 1598 listed for damp locations

DIMMING ■ Forward/reverse phase dimming (120V only) ■ 0-10V 1% Dimming ■ EldoLED 0-10V 1% or 0.1% ■ Lutron Tu-Wire 1%

TRIM ASSEMBLY ■ Die-cast trim and heat sink assembly with

quick connect for easy installation. ■ High optical transparency diffusion lens to obscure LED ■ Wet location listed

INSTALLATION ■ L2, L3 and L4 Type IC; rated for direct contact with insulation

■ L5 Type non-IC; insulation should be kept minimum 3” away from all sides of fixture

■ Fixture includes adjustable bar hangers (14”-24”) for wood joist or t-bar ceiling installations

■ Accomodates ceilings with a 1/2” to 1-1/2” thickness ■ Maximum ambient temperature 50°C (122°F)

EMERGENCY ■ EM option mounted nearby the fixture above ceiling

IOTA PC8 diagram IOTA ILB-CP instruction Manual

LISTING ■ Trim Assembly: ETL listed to US and Canadian standards for wet location

■ Can be used to comply with 2016 Title 24 Part 6 - High efficacy LED light source requirements

■ ENERGY STAR® Qualified ■ JA8-2016 ■ 5-Year Intense LED Limited Warranty

Trim Assembly Part Number (Example: LCT4DRTW-SF279)

Trim Finish CCT/CRI2

LCT4DRT (Round)LCT4DST (Square)

W-SFB-SFSN-SFW

(White/Self-Flanged)(Black/Self-Flanged)(Satin Nickel/Self-Flanged/White)

279309

(2700k/90 CRI)(3000k/90 CRI)

Ceiling Cut Out: 4 5/16” octagonal. Maximum Ceiling Thickness: 1 1/2”

Frame-In Part Number (Example: LC4FL2ED10V1)

Frame-In Wattage Dimming Voltage Options

LC4F (Alternate Dimming & Emergency housing)

L2L3L4L51

(8 Watts)(10 Watts)(12 Watts)(16 Watts)

LUTLUT2ED10V1ED10V01D101ELV

(Lutron Ecosystem 1%)(Lutron Tu-Wire phase 1%)(eldoLED 0-10V 1%)(eldoLED 0-10V 0.1%)(0-10V Dimming 1%)(Phase Dimming)

blank27

(120V)(277V)

EM7 (7W Emergency BackupIOTA part #ILB-CP07-A)

Note:1. L5 not IC rated2. Consult factory for other CCT options

ELECTRICAL DATA

LED Light Engine System Wattage * CCT / CRINominal Delivered Lumens **

Round Square

L2L3L4L5

8W10W12W16W

2700K/3000K / 92 CRI2700K/3000K / 92 CRI2700K/3000K / 92 CRI 2700K/3000K / 92 CRI

600lm850lm1000lm1300lm

500lm750lm850lm1100lm

* System Wattage includes driver and LED Module consumption** Delivered Lumen output will vary depending on CCT, CRI and finish

Round Square

4” 5”

2 3/8”

5”3 3/8”

1 11/16”

For fire rated housing option, see LC4 Downlight specification

■ ENERGY STAR® Qualified 1

JOB NAME

CATALOG NUMBER

NOTES TYPE

FUNDAMENTALS L/M-0521:18 P-6

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 2: LC4F / LCT4D€¦ · UL 1598 listed for damp locations DIMMING Forward/reverse phase dimming ... insulation L5 Type non-IC; insulation should be kept minimum 3” away

LC4F / LCT4D4” Fundamentals™ LED Downlight Alternative Dimming and Emergency Backup

Housing:

9”

6 1/4” 7 15/16”

4 3/16”

4 1/16”

14” - 24”

Ceiling Cut Out: 4 5/16” octagonal. Maximum Ceiling Thickness: 1 1/2”

4” 5”

Round

Trim

2 3/8”

1/8”1”

4 5/16”

Ceiling Cut Out

Square

Trim

5”3 3/8”

1 11/16”

1/8”1”

JOB NAME

CATALOG NUMBER

NOTES TYPE

FUNDAMENTALS L/M-0521:18 P-7

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 3: LC4F / LCT4D€¦ · UL 1598 listed for damp locations DIMMING Forward/reverse phase dimming ... insulation L5 Type non-IC; insulation should be kept minimum 3” away

Report #: ILL-20180227-1.001

LC4L2/LCT4DRTW-SF309

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

273272262237200157

90° Distribution

Watts: 8Lumens: 593 LPW: 78 CCT: 3000K

1.9fc

2.7fc

4.3fc

7.6fc 14’

18.6’

23.3’

27.9’Beam

DiameterFootcandles

at Nadir

12’

10’

8’

6’

Throw Distance

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.00)3500K / 92 CRI (x 1.00)

LC4F / LCT4D4” Fundamentals™ LED Downlight Alternative Dimming and Emergency Backup

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

388387371337285223

90° Distribution

Watts: 10Lumens: 842 LPW: 83 CCT: 3000K

2.7fc

3.9fc

6.1fc

10.8fc 14’

18.6’

23.3’

27.9’Beam

DiameterFootcandles

at Nadir

12’

10’

8’

6’

Throw Distance

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

496493474430364285

90° Distribution

Watts: 12Lumens: 995 LPW: 82 CCT: 3000K

3.4fc

5.0fc

7.7fc

13.8fc 14’

18.6’

23.3’

27.9’Beam

DiameterFootcandles

at Nadir

12’

10’

8’

6’

Throw Distance

Report #: ILL-20180227-1.002

LC4L3/LCT4DRTW-SF309

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.003500K / 92 CRI (x 1.00)

Report #: ILL-20180227-1.003

LC4L4/LCT4DRTW-SF309

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.00)3500K / 92 CRI (x 1.00)

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

575572546491404271

90° Distribution

Watts: 16Lumens: 1120 LPW: 69 CCT: 3000K

4.0fc

5.8fc

9.0fc

16.0fc 14’

18.6’

23.3’

27.9’Beam

DiameterFootcandles

at Nadir

12’

10’

8’

6’

Throw Distance

Report #: ILL-20180227-1.004

LC4L5/LCT4DRTW-SF309

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.00)3500K / 92 CRI (x 1.00)

JOB NAME

CATALOG NUMBER

NOTES TYPE

FUNDAMENTALS L/M-0521:18 P-8

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 4: LC4F / LCT4D€¦ · UL 1598 listed for damp locations DIMMING Forward/reverse phase dimming ... insulation L5 Type non-IC; insulation should be kept minimum 3” away

Report #: ILL-20180223-5.001

LC4L2/LCT4DSTW-SF309

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

264263251226186123

90° Distribution

Watts: 8Lumens: 515 LPW: 68 CCT: 3000K

1.8fc

2.6fc

4.1fc

7.3fc 11.6’

15.4’

19.3’

23.1’Beam

DiameterFootcandles

at Nadir

12’

10’

8’

6’

Throw Distance

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.00)3500K / 92 CRI (x 1.00)

LC4F / LCT4D4” Fundamentals™ LED Downlight Alternative Dimming and Emergency Backup

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

375373357321263177

90° Distribution

Watts: 10Lumens: 731 LPW: 72 CCT: 3000K

2.6fc

3.8fc

5.9fc

10.4fc

Beam Diameter

Footcandles at Nadir

12’

10’

8’

6’

Throw Distance

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

479477455409337226

90° Distribution

Watts: 12Lumens: 864 LPW: 71 CCT: 3000K

3.3fc

4.8fc

7.5fc

13.3fc

Beam Diameter

Footcandles at Nadir

12’

10’

8’

6’

Throw Distance

Report #: ILL-20180223-5.002

LC4L3/LCT4DSTW-SF309

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.00)3500K / 92 CRI (x 1.00)

Report #: ILL-20180223-5.003

LC4L4/LCT4DSTW-SF309

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.00)3500K / 92 CRI (x 1.00)

Candelas at Nadir

Degree CBCP

0°5°15°25°35°45°

575572546491404271

90° Distribution

Watts: 16Lumens: 1120 LPW: 69 CCT: 3000K

4.0fc

5.8fc

9.0fc

16.0fc

Beam Diameter

Footcandles at Nadir

12’

10’

8’

6’

Throw Distance

Report #: ILL-20180223-5.004

LC4L5/LCT4DSTW-SF309

CCT / CRI Multipliers: 2700K / 92 CRI (x 1.00) 3000K / 92 CRI (x 1.00)3500K / 92 CRI (x 1.00)

11.6’

15.4’

19.3’

23.1’

11.6’

15.4’

19.3’

23.1’

11.6’

15.4’

19.3’

23.1’

JOB NAME

CATALOG NUMBER

NOTES TYPE

FUNDAMENTALS L/M-0521:18 P-9

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 5: LC4F / LCT4D€¦ · UL 1598 listed for damp locations DIMMING Forward/reverse phase dimming ... insulation L5 Type non-IC; insulation should be kept minimum 3” away

DIMMING COMPATIBILITY

DRIVERINPUT

GREY (-)

0-10V DIMMER

BLACK - NEGATIVE

LED LIGHT ENGINE

RED - POSITIVE

VIOLET (+)

BLACK

WHITE

GREEN

FORWARD / REVERSE PHASE DIMMING ■ 120V only ■ Consult dimming manufacturer for installation instructions

DRIVER120V INPUT

FROM DIMMER

BLACK - NEGATIVE

LED LIGHT ENGINE

RED - POSITIVEBLACK

WHITE

GREEN

0-10V DIMMING ■ 120V/277V ■ Consult dimming manufacturer for installation instructions and power packs

LUTRON ECOSYSTEM® DIMMING - 120V or 277V - Consult dimming manufacturer for installation instructions

COMPATIBLE DIMMERSProduct Part Number(s)EcoSystem CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM, EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum

DRIVER

ECO SYSTEM CONTROL

(BY OTHERS)

ECO SYS BUS

BLACK - NEGATIVE

LED LIGHT ENGINE

RED - POSITIVE

VIOLET (E1)

VIOLET (E2)

BLACK

WHITE

GREEN

JOB NAME

CATALOG NUMBER

NOTES TYPE

FUNDAMENTALS L/M-0521:18 P-10

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.