magnum control valve - lenntech · commercial control valves magnum ® control valve logix™...

8
COMMERCIAL CONTROL VALVES Magnum ® Control Valve Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289

Upload: dangdat

Post on 14-May-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no

COMMERCIAL CONTROL VALVES

Magnum® Control Valve

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Page 2: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no

COMMERCIAL CONTROL VALVES

Magnum® Control Valve

Logix™ Series • All-electronic control platform• 24-hour super-capacitor backup – no battery necessary• Remote mount kit allows programming module to be installed up to 40 feet away• Universal controller – works on all Autotrol® brand valves• Automatic capacity calculations – no math or salt tables necessary• 12-volt operation

742 Time Clock• Simple, economic electronic time clock (chronometric)• 7- or 99-day regeneration settings• Filter or conditioner setting in one control• Fully programmable cycle times• Salt setting in 1-pound increments (lbs/cu ft)• Single controller operates Autotrol 255, 263, 268, 278 models, and

Pentair Water Magnum and Magnum IT with one controller

762 Demand• Simple, economic electronic demand (volumetric)• Calendar override – 99 day• 28-day variable reserve• Filter or conditioner setting in one controller• Automatic capacity calculations• Fully programmable cycle times• Salt setting in 1-pound increments (lbs/cu ft)• Operates 255, 263, 268, 278, and Magnum IT with one controller

764 DemandSame features as the 762, plus:• Multi-tank applications (twin alternating, multi-tank parallel)• Control lockout• Remote regeneration

Controller OptionsThe Pentair Water® Magnum Control Valve is one of the most versatile valves on the market.

The Logix series offers the ultimate in control for the Magnum® valve. Simple 3-step programming and installation makes this electronic controller the industry leader.

Page 3: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no

Flow Rates (Valve Only)Service @ 15 psi (1.03 bar) drop 76 gpm (17.3 m3/hr)Backwash @ 25 psi (1.72 bar) drop 89 gpm (20.2 m3/hr)Service Cv = 19.5 (Kv = 17)Backwash Cv = 17.8 (Kv = 19.9)

Valve Connections/DimensionsTank Thread 4-inch 8 UNInlet/Outlet 2-inch: connections NPT or BSPT, Female, CPVCBrine Line 3/4-inch NPTDrain Line* 1-1/2-inch: connections for NPT or BSPT, Female, CPVCRiser Tube Diameter 1-1/2-inchRiser Installation Above top of tank 5/8-inch (±1/8-inch)Pilot Drain and Auxiliary Hydraulic Output 1/4-inch tube fitting

* Valve installed drain flow controls available (5 – 40 gpm). If higher backwash flow is needed, an external flow control will be required.

Design Specifications/RatingsValve Body ThermoplasticO-rings EPDMInjector 7 sizes available: 14, 16, 18, 21, 24, 30, 36Working Pressure 25 psi – 100 psi (1.72 bar – 6.9 bar)Water Temperature 35° – 100°F (2° – 38°C), 120°F (49°C) Ambient

OptionsTop Mount or Side Mount Configuration

Electrical Specifications Controller Operating Voltage 12 Volt – AC (Requires a transformer supplied by GE)

Input Supply Frequency 50 or 60 Hz (Controller configuration dependent)

Motor Input Voltage 12 Volt – AC

Control System Power Consumption 3 Watts average

Transformer Specifications – All Controllers All Controllers require the use of a Pentair Water supplied transformer.

Transformer Output Voltage 12 Volt – AC 400mA

Transformer Input Options 115 Volt – AC 50/60 Hz; 230 Volt – AC 50/60 Hz; 100 Volt – AC 50/60 Hz

Transformer Plug Options Indoor North American Plug Australian Plug

Outdoor North American United Kingdom Plug (UL Listed for outdoor use) Mainland Europe Plug Japanese Plug

Taiwan/Korea Plug

Additional transformers may be available – call for more information.

Specifications

Page 4: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no

Injector Performance – Magnum

COMMERCIAL CONTROL VALVES

Magnum® Control Valve

3.00

2.50

2.00

1.50

1.00

0.50

0.00

m3/hr gpm

14.0

12.0

10.0

8.0

6.0

4.0

2.0

0.0

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.50

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

10.0

8.0

6.0

4.0

2.0

0.0

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

5.00

4.00

3.00

2.00

1.00

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.50

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

Injector 1000441For 14-inch Tanks

Injector 1000443For 18-inch Tanks

Injector 1000445For 24-inch Tanks

Injector 1000446For 30-inch Tanks

Injector 1000447For 36-inch Tanks

Injector 1000444For 21-inch Tanks

Injector 1000442For 16-inch Tanks

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

Page 5: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no

NOTE: Brine draw and rinse rates on empty tank.

3.00

2.50

2.00

1.50

1.00

0.50

0.00

m3/hr gpm

14.0

12.0

10.0

8.0

6.0

4.0

2.0

0.0

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.50

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

10.0

8.0

6.0

4.0

2.0

0.0

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

5.00

4.00

3.00

2.00

1.00

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.50

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

Injector 1000441For 14-inch Tanks

Injector 1000443For 18-inch Tanks

Injector 1000445For 24-inch Tanks

Injector 1000446For 30-inch Tanks

Injector 1000447For 36-inch Tanks

Injector 1000444For 21-inch Tanks

Injector 1000442For 16-inch Tanks

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

3.00

2.50

2.00

1.50

1.00

0.50

0.00

m3/hr gpm

14.0

12.0

10.0

8.0

6.0

4.0

2.0

0.0

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.50

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

10.0

8.0

6.0

4.0

2.0

0.0

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

1.00

0.80

0.60

0.40

0.20

0.00

m3/hr gpm

5.00

4.00

3.00

2.00

1.00

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00

m3/hr gpm

3.50

3.00

2.50

2.00

1.50

1.00

0.50

0.00

bar

PSI 202 3.5 5 6 7.5

40 60 80 100 120

Injector 1000441For 14-inch Tanks

Injector 1000443For 18-inch Tanks

Injector 1000445For 24-inch Tanks

Injector 1000446For 30-inch Tanks

Injector 1000447For 36-inch Tanks

Injector 1000444For 21-inch Tanks

Injector 1000442For 16-inch Tanks

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

Page 6: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no

P

R

E

S

S

U

R

E

D

R

O

P

F L O W R A T E

MAGNUM C

v BAC

KWAS

H F

LOW

MAGNUM Cv SERVIC

E FLO

W

10 3020 40 50 60 10080 90700

m3/h

gpm

0 2 4 6 8 10 12 14 16 18 20 22

240

220

200

180

160

140

120

100

80

60

40

20

0

bar psi

35

30

25

20

15

10

 5

  0

Valve Flow Rate Characteristics

Flow Sensor OptionsInternal Turbine UnitNormal Operating Range 2 - 80 gpm (0.45 - 18.1 m3/hr)

Peak Operating Range 1 - 100 gpm (0.22 - 22.7 m3/hr)

Normal Accuracy Range ±3%

External Flow Meter – 2.0 InchNormal Operating Range* 5.0 - 225 gpm (0.50 - 51.0 m3/hr)

Normal Accuracy Range ±3%

Connections 2-inch: connections NPT or BSPT, Female, CPVC

*Recommended maximum continuous duty flow rate of 2-inch turbine is 70% of maximum flow rate.

Tank Adapter OptionsThreaded Stainless Steel 4-inch 8 UN

Flanged Stainless Steel 6-inch

Magnum Cv C&I Valve (1-1/2 inch inlet)

COMMERCIAL CONTROL VALVES

Magnum® Control Valve

Page 7: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no

1-1/2-inch Magnum Cv 2-inch Magnum IT

3.993 (10.14 cm)

6.493 (16.5 cm)

7.500 (19.05 cm)

22.796 (57.90 cm)

2.817 (7.15 cm)

4.018 (10.20 cm)

8.680 (22.04 cm)

9.000 (22.86 cm)13.481 (34.24 cm)

19.500 (49.53 cm)

7.000 (17.78 cm)

14.000 (35.56 cm)

15.539 (39.47 cm)

1.113 (2.82 cm)

11.471 (29.13 cm)

15.53 91.113

11.376

4.42 9

13.4819.000

9.750

7.000 6.500

16.250

8.710

3.9982.817

27.224

13.993 4.429

DRAIN

AUX.

4.500

4.500

Magnum Valve Outline Dimensions

3.993 (10.14 cm)

6.493 (16.5 cm)

7.500 (19.05 cm)

22.796 (57.90 cm)

2.817 (7.15 cm)

4.018 (10.20 cm)

8.680 (22.04 cm)

9.000 (22.86 cm)13.481 (34.24 cm)

19.500 (49.53 cm)

7.000 (17.78 cm)

14.000 (35.56 cm)

15.539 (39.47 cm)

1.113 (2.82 cm)

11.471 (29.13 cm)

15.53 91.113

11.376

4.42 9

13.4819.000

9.750

7.000 6.500

16.250

8.710

3.9982.817

27.224

13.993 4.429

DRAIN

AUX.

4.500

4.500

Page 8: Magnum Control Valve - Lenntech · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup – no