maintenance guide socket layout ………………………………..p2 socket identification...
TRANSCRIPT
MAINTENANCE GUIDE
SOCKET LAYOUT ………………………………..p2
SOCKET IDENTIFICATION …………………..p3
SOCKET ASSEMBLED ………………………….p4 ~p7
CONTACTS REMOVAL …………………………p8
UPPER ELASTOMER REPLACEMENT …….p9
LOWER ELASTOMER REPLACEMENT ……p10
CLEAN …………………………………………….p11~12
REPLACEMENT FREQUENCY ……………….p13
Teecons
Patent: US79550921
SOCKET LAYOUT Teecons
2
SOCKET IDENTIFICATIONTeecons
3
SOCKET ASSEMBLED
STEP 1: INSERT LOWER ELASTOMERTO BOTTOM SIDE OF CONTACTS HOUSING
STEP 2: REVERSE CONTACTS HOUSING AND PLACE ON SUPPORTER
Teecons
4
STEP 3: INSERT CONTACTS TO SLOT OF CONTACTS HOUSING AND PUSH INTO LOWER ELASTOMER
Teecons
5
STEP 4: INSERT UPPER ELASTOMER TO GUIDE PLATE
STEP 5: ASSEMBLE GUIDE PLATE AND CONTACTS HOUSING
Teecons 6
STEP 6: GROUND MODULE INSTALLATION (OPTIONAL)
Teecons
LIGHT PRESS INSERTION
7
CONTACTS REMOVAL Teecons
8
UPPER ELASTOMER REPLACEMENT
ELASTOMER REMOVAL
ELASTOMER INSERTION
Teecons
9
LOWER ELASTOMER REPLACEMENT
ELASTOMER REMOVAL
ELASTOMER INSERTION
Teecons
10
CLEAN
CLEAN TOOL (OPTIONAL)
CLEAN BLOCK
HANDLE
Teecons
11
CLEAN PROCEDURE
ON-LINE CLEAN
CLEAN FREQUENCY -- 10K
UP/DOWN -- 10 TIMES
Teecons
12
REPLACEMENT FREQUENCY
(RECOMMENDATIONS)
1 CONTACTS 500K
2 CONTACTS HOUSING 1.5kk
3 UPPER ELASTOMER 200K
4 LOWER ELASTOMER 800K
5 GUIDE PLATE 500K
6 GND MODULE 1kk
Teecons