MANUAL FOR
HYDRAULIC SYSTEM
LES 24.03.10-01 PSZL 12,5-220-5,5-45
BH2781
1/14
Declaration of incorporation of machinery
component The Machinery Directive 2006/42/EC Annex II B
The above machine has been manufactured in accordance with the Machinery Directive i.e. Council Directive 2006/42/EC of 17 May 2006 on the harmonisation of the laws of the Member States relating to machinery. The following health and safety requirements in Appendix 1 have been complied with – VSSK: 1.5.3.
Manufactured in accordance with the following EC Directives: *The Low Voltage Directive, i.e. Council Directive 2006/95/EC of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits. The EMC Directive, i.e. Council Directive 2004/108/EC of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility. The machinery component must not be used until the finished machine into which it is to be incorporated has been tested for compatibility and found to comply with all relevant health and safety requirements as set out in 2006/42/EC and other relevant directives. Titel: Managing Director Name: Ole Krabbe Date: 20 January 2012 Signature:
AVN ENERGY
Dalager 5 DK-2605 Brøndby Fax +45 43 24 55 05 E-Mail [email protected] Bergsøesvej 14 DK-8600 Silkeborg Fax +45 86 80 55 88 Internetadresse www.avn.dk
Representative Company name: AVN Hydraulik A/S Address: Dalager 5 Postal code/city: DK-2605 Brøndby Country: Denmark Telephone: +45 70 20 04 11 Fax: +45 43 24 55 05
Person authorised to hand over the technical dossier:
Ole Krabbe
Dalager 5 DK-2605 Brøndby Denmark
Machine: Pump station Type: PSZL 12,5-220-5,5-45 Serial no: 55.1211147 Year: 2012
Tlf. 70 20 04 11
2/14
Dalager 5 DK-2605 Brøndby Fax +45 4324 5505 E-mail: [email protected]
Bergsøesvej 14 DK-8600 Silkeborg Fax +45 8680 5588 Web: www.avn.dk +45 70 20 04 11
How to Start Up and Maintain the Hydraulic System
rev. 0
Thank you for choosing the AVN Hydraulic System! In order to obtain the maximum function and working life of the system, the following instructions for starting up and maintenance should be followed. If a complete system has been delivered from AVN Hydraulik A/S, it has been tested and the pres-sure has been set to the maximum (see the code at the type plate). *********************************************************************************************************
Starting Up: Connect the pumping station to the rest of the system and check all the connections for correct
tightening. Fill up with recommended hydraulic oil until the check glass is full. Screw out the adjusting screw of the relief valve completely. Start the pumping station shortly (start/stop) in order to control the direction of rotation of the elec-
tric motor (indicator is attached). Start the pumping station and create a back pressure in the system. Screw in the adjusting screw of the relief valve slowly; the pressure is now rising in the system.
Adjust only to the working pressure required and check for leakage. If there are any other relief valves in the system, they should not be adjusted until the main relief
valve has been adjusted. If there are any piston pumps connected to the system, they must be filled up with oil before start. The pumping station is now ready for use. *********************************************************************************************************
Maintenance: Check your system regularly to prevent any unforeseen breakdowns. Check for leakage or any
unusual noises and check the operating temperature. Change the filter cartridge regularly; the first time after 40-50 operating hours and then after every
500 operating hours. Change the hydraulic oil according to the instructions from your supplier. The oil should also be
checked for remaining operating hours at least once a year. *********************************************************************************************************
Mounting and Service: AVN Hydraulik A/S can offer a complete package of mounting and starting up the system. AVN Hydraulik A/S is at your disposal with service regarding breakdowns or any other problems
with the system.
3/14
4/14
Kongskilde Maskinfabrik A/SSkælskørvej 64Sorø
BOM Item No.
DIAGRAMDATEPAGE
PSZL 12,5-220-5,5-45 incl. 1 stk 4/3-vejs ventil
AVN Hydraulik A/S
BH2781
LES 24.03.10-01 B20-01-12
1
QUANTITYDESCRIPTIONITEM NO.POSITIONUNIT OFMEASURE
VERSION NO.
PCS.1Cover for S114/1152410911PCS.1Steel tank ZL unit2410921
45L S114 without cover
PCS.1Tandhjulspumpe Grp. 217811922SPA-8D-10N
PCS.1RETURNFILTER FIR 100/021326503PCS.1Flange & coupling AC motor2411024
F67 5,5-7,5KW IEC 132 GR2
PCS.1IE2 motorer10037305HMA2132S4 5,5kW 230/400 B5 IE2
PCS.101Y/ZL MANIFOLD 50-220 BAR2411056PCS.1Gauge valve2114007
FT 290, 1/4"
PCS.1GAUGE Ø63 0-250BAR 1/4"1845008PCS.3ARON SOLENOID VALVE AD 3E 01C 17009PCS.7Emergency override knob3259
E1 for AD3 serie 3 D15 DC
PCS.1Filler / breather cap11150010FEF1H10SL
PCS.1LEVEL CONTROL HMCHI-OT=20018552811PCS.1Relief valve CETOP31970012
AM 3 VM A C2 150 bar
PCS.1ARON SOLENOID VAL. AD 3E 02E M120013PCS.1Pressostat max 350bar43050114
HED8OA-2X/350K14
PCS.1Filter element with bypass1348203ACR 100/02, P171531
5/14
Dalager 5 DK-2605 Brøndby Fax +45 4324 5500 E-mail: [email protected]
Suensonsvej 14 DK-8600 Silkeborg Fax +45 8722 8105 Web: www.avn.dk +45 70 20 04 11
”ZL” - Steel tank S112 - S113 - S114 - S115 - S176 - S187
CODE Tank capacity
(litres) Useable capacity
(litres) CODE
Tank capacity (litres)
Useable capacity (litres)
S112 20 12 S113 30 22
CODE Tank capacity
(litres) Useable capacity
(litres) CODE
Tank capacity (litres)
Useable capacity (litres)
S114 45 30 S115 60 42
CODE Tank capacity
(litres) Useable capacity
(litres) CODE
Tank capacity (litres)
Useable capacity (litres)
S176 90 75 S187 120 100
rev. 0
10.26.1
Page
6/14
Dalager 5 DK-2605 Brøndby Fax +45 4324 5505 E-mail: [email protected] Suensonsvej 14 DK-8600 Silkeborg Fax +45 8722 8100 Web: www.avn.dk � +45 70 20 04 11
Gear pumps group 2
lotti Strozzi – Galtech
Shaft type 10
Example of ordering code
Pump type
Displacement (see tabel)
Connections type: G – N – T
Shaft type: 10 – 16
D = Clockwise rotation S = Anticlockwise rotation
Cast-iron flange and cover (also available in aluminium)
For other designs, please ask our sales department.
Type Displacement cm³/rpm
l/min at 1.400 rpm
Working pressure bar Max. speed rpm/min.
Dimensions mm
Continuous Max. A B
2 SP G4 4,0 5,6 280 320 4.000 44,4 93,0 3,400
2 SP G6 6,0 8,4 280 320 4.000 46,0 96,3 3,550
2 SP G8 8,5 11,9 280 320 3.500 48,1 100,5 3,700
2 SP G11 11,0 15,4 280 320 3.500 50,2 104,6 3,800
2 SP G14 14,0 19,6 270 290 3.500 52,7 109,6 3,900
2 SP G19 19,5 27,3 210 230 3.300 57,3 118,8 4,200
Mass kg
2 SP G22 22,5 31,5 190 210 2.800 59,8 123,8 4,350
2 SP G26 26,0 36,4 170 190 2.500 62,7 129,6 4,500
2 SP G16 16,5 23,1 230 250 3.500 54,8 113,8 4,050
rev. 0
9.3
Page
7/14
AVN HYDRAULIK A-S
Return in tank filters FIR 100/02
AVN no. 132650
Dalager 1 DK-2605 Brøndby Fax +45 43 24 55 00 E-mail [email protected] Page Suensonsvej 14 DK-8600 Silkeborg Fax +45 87 22 81 00 Internetadresse www.avn.dk 11.132650.1 ℡ +45 70 20 04 11
8/14
AVN HYDRAULIK A-S
Dalager 5 DK-2605 Brøndby Fax +45 4324 5505 E-mail: [email protected] Suensonsvej 14 DK-8600 Silkeborg Fax +45 8722 8100 Web: www.avn.dk � +45 70 20 04 11
F67 Flange / coupling AVN no.: 241102
rev. 0
10.241102.1
Page
Kode Pump size
F67 2 / 2 RO
Motor size 132
9/14
Dalager 5 DK-2605 Brøndby Fax +45 4324 5505 E-mail: [email protected] Suensonsvej 14 DK-8600 Silkeborg Fax +45 8722 8100 Web: www.avn.dk +45 70 20 04 11
Electric motor
Technial data for 50 Hz – 4 pin
Type Power (kW)
Speed r.p.m.
Amp. 400V
Cos. φ
ή % Mz/Mn lz/ln
B3 B5 4AP63-4 0,18 1.350 0,57 0,75 60 1,8 3,2 4,5 5 4AP71-4s 0,25 1.380 0,77 0,73 64 1,9 3,4 5,5 6,2 4AP71-4 0,37 1.370 1,05 0,77 68 1,9 3,1 6,5 7,2 4AP80-4s 0,55 1.380 1,42 0,76 74 1,8 4,2 9 10,3 4AP80-4 0,75 1.380 1,9 0,73 72 1,8 3,8 10 11,3 4AP90S-4 1,1 1.410 2,7 0,8 74 2 4,6 13 14,2 4AP90L-4 1,5 1.410 3,4 0,82 77 2,3 4,8 15,5 16,7
Weight (kg)
Technial data for 7AA default engine modification, 50 Hz, IP 55 – 4 pin
Type Power (kW)
Speed r.p.m.
Amp. 400V
Cos. φ
ή % Mz/Mn lz/ln
B3 B5 7AA 100L 04K 2,2 1.420 4,9 0,82 80 2,6 5,5 21,5 24 7AA 100L 04 3 1.420 6,5 0,83 81,5 2,7 6,2 24,5 27 7AA 112M 04 4 1.440 8,3 0,83 84 2,8 6,5 31 33
7AA 132M 04 7,5 1.455 15,1 0,82 87,5 2,7 7,2 49 52,5 7AA 132M 04V 10 1.440 21 0,81 85 3,3 7 62 65,5 7AA 160M 04 11 1.460 21,5 0,84 88,5 2,2 6,3 68 74 7AA 160L 04 15 1.460 28,5 0,84 90,5 2,8 7,3 93,5 99,5
Weight (kg)
7AA 132S 04 5,5 1.455 11,4 0,81 86 2,4 6,3 42,5 46
rev. 1
3.10.1 Side
10/14
AVN HYDRAULIK A-S
Pressure-Gauges Ø63 0-250 Bar – N
Dalager 5 DK-2605 Brøndby Fax +45 43 24 55 05 E-mail [email protected] Page Suensonsvej 14 DK-8600 Silkeborg Fax +45 87 22 81 00 Internetadresse www.avn.dk 12.184500.1 ���� +45 70 20 04 11
11/14
Dalager 5 DK-2605 Brøndby Fax +45 4324 5505 E-mail: [email protected] Suensonsvej 14 DK-8600 Silkeborg Fax +45 8722 8100 Web: www.avn.dk +45 70 20 04 11
Directional controlvalve AD3 CETOP 3/NG6
ARON
Order code:
AD Directional valve
3 CETOP 3 / NG6
* Type og operator (see table 1)
** Spool type (see table 5)
* Mounting type (see table 2)
* Voltage (see table 3)
** Variants
2 Serial no.
Data: Valve type Spool valve
Max. flow 60 l/min
Max. Pressure port P/A/B 320 bar
Max. Pressure port T 160 bar
rev. 1.0
7.1.1 Page
12/14
Dalager 5 DK-2605 Brøndby Fax +45 4324 5505 E-mail: [email protected]
Suensonsvej 14 DK-8600 Silkeborg Fax +45 8722 8100 Web: www.avn.dk +45 70 20 04 11
Directional controlvalve AD3
Spool Symbol Transient position
20
21
Two solenoids ”D” mounting spool
Spool Symbol Transient position
01
02
03
04
Two solenoids ”C” mounting spool
Spool Symbol Transient position
01
02
03
04
16
One solenoid ”E” mounting spool
Table 5
Only the most common types is shown. In case you need information concerning other types, please do not hesitate to contact our sales department or visit our website.
Table 2 – Mounting
* = with lock
C
D*
E
Table 1 – Type of operator
E = Electrical M = Mechanical D = Direct mechanical O = Hydraulic P = Pneumatic L = Lever operation
Table 3 – Voltage
AC – Voltage Rated power
A = 24V / 50 Hz 57 VA
J = 115V / 50 Hz - 120V / 60 Hz 52 VA
Y = 230V / 50 Hz - 240V / 60 Hz 55 VA
DC – Voltage Rated power
L = 12 VDC 30 W
M = 24 VDC 30 W
ARON
rev. 1.0
7.1.2
Page
13/14
AVN HYDRAULIK A-S
Breather / oil filter CAP FEF 1