manual instalare centrala termica westen quasar d

26
IT caldaia murale a gas ad alto rendimento manuale per l’uso destinato all’utente ed all’installatore GB High performance gas-fired wall-mounted boilers Operating and installation instructions ES Caldera mural de gas de alto rendimiento Manual para el usuario y el instalador RU Высокопроизводительные настенные газовые котлы Руководство по установке и эксплуатации HU Magas hozamú fali gázkazán Felhasználói és szerelıi kézikönyv RO Centrale murale pe gaz cu randament ridicat InstrucŃiuni pentru instalator i pentru utilizator GR Επιτοιχιος λεβητας αεριου υψηλης αποδοσης ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ ΓΙΑ ΤΟ ΧΡΗΣΤΗ ΚΑΙ ΤΟΝ ΕΓΚΑΤΑΣΤΑΤΗ

Upload: anon953298498

Post on 26-Oct-2015

2.414 views

Category:

Documents


124 download

TRANSCRIPT

  • IT caldaia murale a gas ad alto rendimento manuale per luso destinato allutente ed allinstallatore

    GB High performance gas-fired wall-mounted boilers Operating and installation instructions

    ES Caldera mural de gas de alto rendimiento Manual para el usuario y el instalador

    RU

    HU Magas hozam fali gzkazn Felhasznli s szereli kziknyv

    RO Centrale murale pe gaz cu randament ridicat Instruciuni pentru instalator i pentru utilizator

    GR

  • INSTRUCIUNI DESTINATE UTILIZATORULUI

    926.275.1 - RO136

    Stimate Client, Compania noastr consider c noua central termic achiziionat va rspunde tuturor exigenelor dumneavoastr. Achiziionarea unui produs wESTEN garanteaz ndeplinirea tuturor ateptrilor dumneavoastr: o bun funcionare i o utilizare simpl i raional. V recomandm s nu lsai deoparte aceste instruciuni nainte de a le fi citit: acestea conin informaii utile pentru o exploatare corect i eficient a centralei dumneavoastr. Fragmentele de ambalaj (pungi din plastic, polistiren etc.) nu trebuie s fie lsate la ndemna copiilor, ntruct constituie poteniale surse de pericol.

    wESTEN declar c aceste modele de centrale poart marca CE , n conformitate cu cerinele eseniale ale urmtoarelor Directive: - Directiva privitoare la gaz 90/396/CEE - Directiva privitoare la Randament 92/42/CEE - Directiva privitoare la Compatibilitatea Electromagnetic 2004/108/CEE - Directiva privitoare la joas tensiune 2006/95/CE

    CUPRINS

    INSTRUCIUNI DESTINATE UTILIZATORULUI

    1. Avertismente anterioare instalrii 137 2. Avertismente anterioare punerii n funciune 137 3. Punerea n funciune a centralei termice 138 4. Reglarea temperaturii ambiante i a temperaturii apei menajere 139

    5. Descrierea tastei (Var - Iarn - Numai nclzire - Oprit) 139 6. Umplerea instalaiei 140 7. Oprirea centralei termice 140 8. nlocuirea gazului 140 9. Oprirea de durat a instalaiei. Protecia mpotriva ngheului (circuitul de nclzire) 141 10. Indicatoare. Intrarea n funciune a dispozitivelor de siguran 141 11. Instruciuni de ntreinere curent 141

    INSTRUCIUNI DESTINATE INSTALATORULUI

    12. Avertismente generale 142 13. Avertismente anterioare instalrii 142 14. Montarea centralei 143 15. Dimensiuni central termic 143 16. Instalarea conductelor de evacuare-admisie 144 17. Conectarea la reeaua electric 148 18. Conectarea termostatului ambiental 148 19. Modaliti de nlocuire a gazului 149 20. Vizualizarea parametrilor pe afiaj (funcie info) 151 21. Setarea parametrilor 152 22. Dispozitive de reglare i siguran 153 23. Poziionarea electrodului de aprindere i detectare a flcrii 154 24. Controlul parametrilor de combustie 154 25. Caracteristici debit/nlime de pompare 154 26. Conectarea sondei externe 155 27. ntreinere anual 155 28. Diagram funcional circuite 156-157 29. Diagram cuplare conectori 158-159 30. Caracteristici tehnice 160

    wESTEN, unul dintre liderii europeni n fabricarea centralelor termice i a sistemelor de nclzire de nalt tehnologie, a obinut certificarea CSQ pentru sistemele de management al calitii (ISO 9001), de management de mediu (ISO 14001) i de management al sntii i securitii ocupaionale (OHSAS 18001). Aceasta nseamn c BAXI S.p.A. are ca obiective strategice protecia mediului, fiabilitatea produselor sale i protecia securitii i a sntii angajailor. Prin organizarea sa, ntreprinderea este angajat s implementeze i s mbunteasc aceste aspecte, pentru a satisface n cel mai bun mod posibil nevoile clienilor.

  • INSTRUCIUNI DESTINATE UTILIZATORULUI

    926.275.1 - RO137

    1. AVERTISMENTE ANTERIOARE INSTALRII

    Aceast central este destinat nclzirii apei la o temperatur inferioar celei de fierbere la presiune atmosferic. Aceasta trebuie s fie racordat la o instalaie de nclzire i la o reea de distribuie a apei calde menajere, compatibil cu prestaiile i puterea sa. nainte de racordarea centralei, efectuat de personal calificat profesional, este necesar efectuarea urmtoarelor operaiuni:

    a) O verificare pentru a v asigura c centrala este proiectat pentru funcionarea cu tipul de gaz disponibil. Acest lucru este indicat pe

    inscripia de pe ambalaj i pe placa tipologic a aparatului. b) Efectuarea unui control al coului de fum pentru a verifica dac acesta are un tiraj corespunztor, s nu prezinte trangulri i s nu

    fie introduse n horn conducte de evacuare de la alte aparate, cu excepia cazului n care acesta este realizat pentru a servi mai multor utilizri, potrivit Normelor specifice i dispoziiilor n vigoare.

    c) Efectuarea unui control pentru a v asigura c, n cazul racordurilor la hornuri preexistente, acestea au fost curate perfect ntruct

    reziduurile, desprinzndu-se de pe perei n timpul funcionrii, ar putea mpiedica circulaia fumului. d) Pe lng acestea este indispensabil, n scopul pstrrii unei funcionri corecte i a garaniei aparatului, s respectai urmtoarele

    indicaii:

    1. Circuit de ap menajer:

    1.1. Dac duritatea apei depete valoarea de 20 F (1 F = 10 mg de carbonat de calciu la litru de ap) se recomand instalarea unui dozator de polifosfai sau a unui sistem cu efect identic, care s corespund normativelor n vigoare.

    1.2. Este necesar efectuarea unei splri minuioase a instalaiei dup instalarea aparatului i nainte de utilizarea sa. 1.3. Materialele utilizate pentru circuitul de ap menajer sunt conforme cu Directiva 98/83/CE.

    2. Circuit de nclzire

    2.1. instalaie nou nainte de instalarea centralei, instalaia trebuie s fie curat corespunztor, n scopul ndeprtrii reziduurilor rmase de la filetri, sudri i eventuali solveni, utiliznd produse adecvate disponibile pe pia, fr acid i nealcaline, care s nu atace metalele, prile din plastic i cauciuc. Produsele recomandate pentru curare sunt: SENTINEL X300 sau X400 i FERNOX Regenerator pentru instalaiile de nclzire. Pentru utilizarea acestor produse urmai cu atenie istruciunile oferite odat cu produsele.

    2.2. instalaie existent: nainte de instalarea centralei instalaia trebuie s fie complet golit i curat corespunztor de murdrie i impuriti utiliznd produsele adecvate disponibile pe pia menionate la punctul 2.1. Pentru protejarea instalaiei de incrustaii este necesar utilizarea produselor inhibitoare cum ar fi SENTINEL X100 i FERNOX Protector pentru instalaiile de nclzire. Pentru utilizarea acestor produse urmai cu atenie instruciunile oferite odat cu produsele. Amintim faptul c prezena unor depuneri n instalaia de nclzire cauzeaz probleme funcionale centralei (ex. supranclzire i zgomote la nivelul schimbtorului de cldur).

    Nerespectarea acestor avertismente atrage dup sine pierderea garaniei aparatului

    2. AVERTISMENTE ANTERIOARE PUNERII N FUNCIUNE

    Prima aprindere trebuie s fie efectuat de Serviciul de Asisten Tehnic autorizat care va trebui s verifice urmtoarele: a) Ca datele de pe placa tipologic a aparatelor s corespund cu cele ale reelelor de alimentare (cu energie electric, ap, gaz). b) Ca instalarea s fie conform normativelor n vigoare din care citm un fragment n manualul tehnic destinat instalatorului. c) Ca racordarea electric s fi fost efectuat regulamentar la o reea cu mpmntare. Lista cu Centrele de Asisten Tehnic autorizate poate fi gsit n foaia anexat. Nerespectarea celor de mai sus atrage dup sine pier- derea garaniei. nainte de punerea n funciune, ndeprtai pelicula protectoare de pe central. Nu utilizai n acest scop instrumente sau materiale abrazive ntruct ar putea deteriora suprafeele vopsite.

    Este interzis utilizarea acestui aparat de ctre persoane (inclusiv copii) cu capaciti fizice, senzoriale i mintale reduse sau de per- soane fr experien i fr cunotine necesare, cu excepia cazurilor n care acestea sunt controlate i instruite privitor la folosirea aparatului de ctre o persoan responsabil de sigurana lor.

  • INSTRUCIUNI DESTINATE UTILIZATORULUI

    926.275.1 - RO138

    3. PUNEREA N FUNCIUNE A CENTRALEI

    0805_2302 / C

    G_2072

    Pentru o aprindere corect, procedai ca mai jos: 1) alimentai centrala cu energie electric; 2) deschidei robinetul de gaz; 3) Apsai tasta ( ) pentru a alege regimul de funcionare Var ( ), Iarn ( ) sau Numai nclzire ( );

    4) Apsai tastele (+/-) pentru reglarea temperaturii circuitului de nclzire ( ) i de ap cald menajer ( ), astfel nct s se aprind arztorul principal.

    Cnd centrala este pornit, pe afiaj apare simbolul ( ). n poziia Var ( ), arztorul principal se va aprinde numai n caz de preluare de ap cald menajer.

    ATENIE La prima aprindere, pn cnd nu se evacueaz aerul existent n conducta de gaz, este posibil ca arztorul s nu se aprind i prin urmare, centrala se blocheaz. n acest caz v recomandm s repetai operaiunile de aprindere, pn cnd gazul ajunge la arztor, apaand tasta ( ) pentru cel puin 2 secunde.

    LEGEND SIMBOLURI

    LEGEND TASTE

    Funcionare n regim de nclzire

    Prezen flacr (arztor aprins)

    Pierdere flacr (lips aprindere)

    Funcionare n regim de ap menajer

    Anomalie generic

    Pornire/Oprire/Var/Iarn

    (+/-) : Reglare a temperaturii apei din circuitul de nclzire

    (+/-) : Reglare a temperaturii apei din circuitul de ap menajer Reset

    Informaii

    RESET

    Lips ap (presiune joas n instalaie)

    Indicator numeric (temperatur, cod. anomalie etc.)

    Figura 1

  • INSTRUCIUNI DESTINATE UTILIZATORULUI

    926.275.1 - RO139

    4. REGLAREA TEMPERATURII AMBIANTE I A TEMPERATURII APEI MENAJERE

    Instalaia trebuie s fie dotat cu termostat ambiental pentru controlul temperaturii n ncperi. Reglarea temperaturii ambiante ( ) i a temperaturi din circuitul de ap menajer ( ) se efectueaz prin apsarea tastelor corespunztoare +/- (figura 1).

    Cnd arztorul e aprins, pe afiaj apare simbolul ( ), aa cum se arat n seciunea 3.1.

    NCLZIRE n timpul funcionrii n modul nclzire, pe afiajul ilustrat n figura 1 apare simbolul ( ) care clipete i temperatura din turul instalaiei de nclzire (C).

    AP CALD MENAJER n timpul funcionrii n modul Ap cald menajera, pe afiajul ilustrat n figura 1 apare simbolul ( ) care clipete i temperatura de ieire a apei calde menajere (C).

    5. DESCRIEREA TASTEI (Var - Iarn - Numai nclzire -

    Oprit) Prin apsarea acestei taste se pot programa urmtoarele moduri de funcionare a centralei:

    VAR IARN NUMAI NCLZIRE OPRIT

    n modul VAR pe afiaj apare simbolul ( ). pe afiaj apare simbolul (*). Centrala satisface doar necesitile de ap cald menajer, nclzirea NU este activ (funcia anti-nghe este activ).

    n modul IARN pe afiaj apar simbolurile ( ) ( ). Centrala satisface att necesitile de ap cald menajer ct i cele de nclzire (funcia anti-nghe este activ).

    n modul NUMAI NCLZIRE pe afiaj apare simbolul ( ). Centrala satisface doar necesitile de nclzire (funcia anti-nghe este activ).

    n cazul selectrii modului OPRIT pe afiaj nu apare nici unul dintre simbolurile ( ) ( ). n aceast modalitate este activ doar funcia anti-nghe n ncpere, orice solicitare de nclzire a apei menajere sau a ncperii nu va fi satisfcut,

  • INSTRUCIUNI DESTINATE UTILIZATORULUI

    926.275.1 - RO140

    6. UMPLEREA INSTALAIEI

    0902_0603 /

    CG_2115

    24 F - 24 ATENIE

    Deconectai centrala de la reeaua electric cu ajutorul ntreruptorului bipolar.

    IMPORTANT: Verificai periodic ca presiu- nea, indicat pe manometru atunci cnd instalaia este rece, s fie de 0,7 - 1,5 bari. n caz de suprapre- siune, deschidei robinetul de evacuare al centralei, iar n caz de presiune joas, deschidei robinetul de ncrcare al centralei (figura 3). Se recomand ca deschiderea acestor robinete s fie efectuat foarte lent, pentru a nlesni evacuarea aerului.

    Figura 2

    A - Robinet de ncrcare B - Robinet de evacuare

    Centrala este dotat cu un presostat hidraulic care, n caz de lips a apei, nu permite funcionarea centralei.

    NOT: Dac se constat scderi frecvente de presiune solicitai intervenia Serviciului de Asisten Tehnic autorizat.

    7. OPRIREA CENTRALEI TERMICE

    Pentru oprirea centralei este necesar deconectarea aparatului de la reeaua de energie electric. n modul OPRIT (seciunea 5) centrala rmne oprit (afiajul indic OFF), dar circuitele electrice rmn sub tensiune i este activ funcia antinghe (seciunea 9).

    8. 8. 8. NLOCUIRE GAZ

    Centralele pot funciona fie cu gaz metan, fie cu gaz GPL. n cazul n care se dovedete a fi necesar transformarea, adresai-v Serviciului de Asisten Tehnic autorizat.

  • INSTRUCIUNI DESTINATE UTILIZATORULUI

    926.275.1 - RO141

    9. OPRIREA DE DURAT A INSTALAIEI. PROTECIE MPOTRIVA NGHEULUI

    Anomalii a 3 RESETABILE

    0607_1205

    Se recomand evitarea golirii ntregii instalaii de nclzire, ntruct schimburile de ap au ca efect i depunerile de calcar, inutile i duntoare, n interiorul centralei i al corpurilor de nclzire. Dac pe timp de iarn, instalaia termic nu este utilizat i n cazul pericolului de nghe, se recomand amestecarea apei din instalaie cu soluii anticongelante adecvate, destinate acestei ntrebuinri specifice (ex. glicol propilenic asociat cu inhibitori ai incrustaiilor i coroziunilor). Unitatea electronic a centralei este prevazut cu o funcie antinghe care, la o temperatur a apei din turul instalaiei, mai mic de 5 C, face ca arztorul s funcioneze, pn la atingerea n tur a unei valori de 30 C. Aceast funcie este operaional dac: * centrala este alimentat cu energie electric; * exist gaz; * presiunea instalaiei este cea prescris; * centrala nu este blocat.

    10. INDICATOARE. INTRAREA N FUNCIUNE A DISPOZITIVELOR DE SIGURAN

    Anomaliile sunt vizualizate pe afiaj identificate de un cod de eroare (ex. E 01):

    Pentru RESETAREA centralei, apaati pentru cel puin 2 secunde tasta R. n caz de intrare n funciune repetat a acestui dispozitiv, adresai-v centrului de asisten tehnic autorizat.

    NOT: Este posibil s efectuai 5 ncercri consecutive de reiniializare dup care centrala se blocheaz. Pentru efectuarea unei noi ncercri de reiniializare, este necesar s oprii centrala pentru cteva secunde.

    Figur

    COD VIZUALIZAT ANOMALIE REZOLVARE

    E01 Blocare lips aprindere Apaati pentru cel puin 2 secunde tasta R. n caz de intrare n funciune repetat a acestui dispozitiv, adresai-v centrului de asisten tehnic autorizat.

    E02 Blocare n urma intrrii n funciune a termostatului de siguran

    Apaati pentru cel puin 2 secunde tasta R. n caz de intrare n funciune repetat a acestui dispozitiv, adresai-v centrului de asisten tehnic autorizat.

    E03 Intrare n funciune a termostatului de gaze arse/presostatului gaze arse

    Adresai-v centrului de asisten tehnic autorizat.

    E04 Blocare datorat stingerii flcrii dup 6 ori consecutive

    Apaati pentru cel puin 2 secunde tasta R. n caz de intrare n funciune repetat a acestui dispozitiv, adresai-v centrului de asisten tehnic autorizat.

    E05 Defeciune sond tur Adresai-v centrului de asisten tehnic autorizat. E06 Defeciune sond circuit de ap menajer Adresai-v centrului de asisten tehnic autorizat. E10 Lips consens al presostatului hidraulic Verificai ca presiunea instalaiei s fie cea prescris. Consultai seciunea 6. Dac

    anomalia persist, adresai-v centrului de asisten tehnic autorizat. E25/E26 Intrare n funciune a dispozitivului de

    siguran, probabil din cauza blocrii pompei. Adresai-v centrului de asisten tehnic autorizat.

    E32 Alarm calcar Adresai-v centrului de asisten tehnic autorizat. E35 Flacr parazit (eroare flacr) Apaati pentru cel puin 2 secunde tasta R. n caz de intrare n funciune repetat a

    acestui dispozitiv, adresai-v centrului de asisten tehnic autorizat. E96 Oprire cauzat de ntrerupere a alimentrii Resetarea este automat. Dac anomalia persist, adresai-v centrului de asisten

    tehnic autorizat.

    NOT: n caz de anomalie, retroiluminarea afiajului clipete simultan cu codul de eroare indicat.

    11. INSTRUCIUNI DE NTREINERE CURENT

    Pentru a asigura centralei o eficien absolut de funcionare i siguran este necesar, la sfritul fiecrui sezon, s solicitai Serviciului de Asisten Tehnic autorizat, verificarea centralei. O ntreinere atent va contribui ntotdeauna la economisirea cheltuielilor de exploatare a centralei. Curarea extern a aparatului nu trebuie s fie efectuat cu substane abrazive, agresive i/sau uor inflamabile (ex. benzin, alcool etc.) i, n orice caz, trebuie s fie efectuat cnd aparatul este oprit (vezi capitolul 7 oprirea centralei termice).

  • 12. AVERTISMENTE GENERALE

    INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO142

    Notele i instruciunile technice care urmeaz sunt adresate instalatorilor, pentru a le da acestora posibilitatea efecturii unei instalri perfecte. Instruciunile referitoare la pornirea i utilizarea centralei sunt coninute n partea destinat utilizatorului. Instalarea, ntreinerea i exploatarea instalaiilor de uz casnic cu gaz trebuie efectuate de ctre personal calificat, potrivit normelor in vigoare.

    Pe lng acestea, trebuie amintite urmtoarele: Centrala poate fi utilizat cu orice tip de plac convectoare, radiator, termoconvector, alimentate cu dou tuburi sau cu unul singur.

    Seciunile circuitului vor fi, n orice caz, calculate dup metodele obinuite, innd cont de caracteristica debit nlime de pompare disponibil la plac i menionat n seciunea 25.

    Fragmentele de ambalaj (pungi din plastic, polistiren, etc.) nu trebuie lsate la ndemna copiilor, ntruct constituie poteniale surse de pericol.

    Prima pornire trebuie s fie efectuat de Serviciul de Asisten Tehnic autorizat, indicat n foaia anexat. Nerespectarea celor de mai sus atrage dup sine pierderea garaniei.

    ATENIE: POMPA SUPLIMENTARA n cazul utilizrii unei pompe suplimentare pe circuitul de nclzire, poziionai-o pe returul centralei. Aceasta va asigura funcionarea corect a presostatului de ap.

    ATENIE n caz de racordare a unei centrale instantanee (mixt) la o instalaie cu panouri solare, temperatura maxim a apei menajere la intrarea n central nu trebuie s depeasc 60 C.

    13. AVERTISMENTE ANTERIOARE INSTALRII

    Aceast central este destinat nclzirii apei la o temperatur inferioar celei de fierbere la presiune atmosferic. Centrala trebuie s fie racordat la o instalaie de nclzire i la o reea de distribuie a apei calde menajere, compatibil cu prestaiile i puterea sa. nainte de racordarea centralei este indispensabil s efectuai urmtoarele:

    a) O verificare pentru a v asigura c centrala este proiectat pentru funcionarea cu tipul de gaz disponibil. Acest lucru este indicat pe

    inscripiile de pe ambalaj i pe placa tipologic a aparatului. b) Efectuarea unui control al coului de fum pentru a verifica dac acesta are un tiraj corespunztor, s nu prezinte trangulri i s nu

    fie introduse n horn conducte de evacuare de la alte aparate, cu excepia cazului n care acesta este realizat pentru a servi mai multor utilizri, potrivit Normelor specifice i dispoziiilor n vigoare.

    c) Efectuarea unui control pentru a v asigura c, n cazul racordurilor la hornuri preexistente, acestea au fost curate perfect ntruct reziduurile, desprinzndu-se de pe perei n timpul funcionrii, ar putea mpiedica circulaia fumului.

    Pe lng acestea este indispensabil, n scopul pstrrii unei funcionri corecte i garaniei aparatului, s respectai urmtoarele indicaii:

    1. Circuit de ap menajer:

    1.1. Dac duritatea apei depete valoarea de 20 F (1 F = 10 mg de carbonat de calciu la litru de ap) se recomand instalarea unui dozator de polifosfai sau a unui sistem cu efect identic, care s corespund normativelor n vigoare.

    1.2. E necesar efectuarea unei splri minuioase a instalaiei dup instalarea aparatului i nainte de utilizarea sa. 1.3. Materialele utilizate pentru circuitul de ap menajer sunt conforme cu Directiva 98/83/CE.

    2. Circuit de nclzire

    2.1. instalaie nou: nainte de instalarea centralei, instalaia trebuie s fie curat corespunztor, n scopul ndeprtrii reziduurilor rmase de la filetri, sudri i eventuali solveni, utiliznd produse adecvate disponibile pe pia, fr acizi i nealcaline, care s nu atace metalele, prile din plastic i cauciuc. Produsele recomandate pentru curare sunt: SENTINEL X300 sau X400 i FERNOX Regenerator pentru instalaiile de nclzire. Pentru utilizarea acestor produse urmai cu atenie instruciunile furnizate odat cu produsele.

    2.2. instalaie existent: nainte de montarea centralei, instalaia trebuie s fie complet golit i curat de murdrie i impuriti, utiliznd produsele adecvate disponibile pe pia menionate la punctul 2.1. Pentru protejarea instalaiei de incrustaii este necesar utilizarea produselor inhibitoare cum ar fi SENTINEL X100 i FERNOX Protector pentru instalaiile de nclzire. Pentru utilizarea acestor produse urmai cu atenie instruciunile furnizate odat cu produsele. Amintim faptul c prezena unor depuneri n instalaia de nclzire cauzeaz probleme funcionale centralei (ex. supranclzire i zgomote la nivelul schimbtorului de cldur).

    Nerespectarea celor de mai sus atrage dup sine pierderea garaniei aparatului.

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO143

    13. IN1S4T. AMLOLNATZAIORNEAE DCENLLTARACLAELIDAIA

    CG_2009 / 0903_0201

    0902_0604 / CG_2011

    CG_2009 / 0903_0202

    24 F - 24

    Alegei locul de amplasare a centralei, apoi aplicai ablonul pe perete. Racordai evile la orificiile de alimentare cu gaz i ap prevzute pe latura inferioar a ablonului. Se recomand s instalai pe circuitul de nclzire dou robinete de interceptare (tur i retur) G3/4, disponibile la cerere, care permit, n caz de intervenii nsemnate, efectuarea lucrrilor fr necesitatea de a goli n ntregime instalaia de nclzire. Dac montai centrala pe o instalaie existent sau dac o nlocuii, v recomandm s montai un vas de decantare pe eava de retur a instalaiei, n partea de jos, pentru a colecta depunerile i reziduu- rile care pot rmne i care pot fi puse n circulaie n instalaie, chiar i dup splare. Cnd centrala e fixat pe perete, racordai conductele de evacuare gaze arse i admisie aer (accesorii furnizate de productor) conform instruciunilor din seciunile urmtoare. n cazul montrii centralei cu tiraj natural, model 24, efectuai racordarea la horn cu ajutorul unui tub metalic rezistent n timp la solicitrile mecanice, la temperaturile nalte, la aciunea produilor de com- bustie i la condens.

    Figura 4

    15. DIM14E.NDSIIMUENNI SCIEONNTIRCAALLDATEIARMIC

    24 24 F Figura 5

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO144

    16. INSTALAREA CONDUCTELOR DE EVACUARE ADMISIE

    on de fixare

    CG_2117 / 0902_1801

    0503_0905/CG1638

    Instalarea centralei poate fi efectuat cu uurin i flexibilitate, datorit accesoriilor livrate i descrise n continuare. La origine, centrala este conceput pentru racordarea la o conduct de evacuare - admisie de tip coaxial, vertical sau orizontal. Cu ajutorul accesoriului de dublare este posibil utilizarea i a con- ductelor separate.

    Uti lizai p entr u insta l are numai ac c es orii l e liv r ate d e productor!

    MSURI DE PRECAUIE: Pentru a garanta o siguran sporit n funcionare, conductele de evacuare a gazelor arse trebuie s fie bine fixate de perete cu ajutorul unor coliere de fixare.

    Figura 6 ... CONDUCT DE EVACUARE - ADMISIE COAXIAL (CONCENTRIC)

    Acest tip de conduct permite evacuarea produselor de ardere i admisia aerului comburant att n exteriorul edificiului, ct i n hor- nurile de tip LAS. Cotul coaxial de 90 permite racordarea centralei la conducta de evacuare-admisie n orice direcie, deoarece se poate roti la 360. n plus, poate fi utilizat i ca un cot suplimentar, alturi de o conduct coaxial sau de un cot de 45.

    Man

    n caz de evacuare la exterior, conducta de evacuare-admisie trebuie s ias din perete cu cel puin 18 mm, pentru a permite poziionarea i sigilarea iglei de protecie din aluminiu, n vederea evitrii infiltraiilor de ap. Asigurai o pant minim n jos, spre exterior, de 1 cm pentru fiecare metru de lungime al conductei.

    Un cot de 90 reduce lungimea total a conductei cu 1 metru.

    Un cot de 45 reduce lungimea total a conductei cu 0,5 metri.

    Primul cot de 90 nu este inclus n calculul lungimii maxime

    di- sponibile.

    Figura 7

    Modelul Centralei

    Lungime (m)

    Evacuare REDUCIE

    A

    0 1 Da 24 F 1 5 Nu

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO145

    L max = 5 m L max = 5 m

    0503_0908/CG1641

    0503_0907/CG1640

    0512_2001

    16.1 EXEMPLE DE INSTALARE CU CONDUCTE ORIZONTALE

    L max = 4 m L max = 4 m

    16.2 EXEMPLE DE INSTALARE CU HORNURI DE TIP LAS

    L max = 5 m

    16.3 EXEMPLE DE INSTALARE CU CONDUCTE VERTICALE Instalarea poate fi efectuat att n cazul acoperiului nclinat ct i n cazul acoperiului plan, montnd un co i igla corespunztoare cu dispozitivul de protecie (accesoriile suplimentare sunt furnizate la cerere).

    L max = 4 m L max = 4 m L max = 2 m L max = 3 m

    Pentru instruciuni mai detaliate privind montarea accesoriilor, consultai datele tehnice care nsoesc accesoriile respective.

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO146

    entru conducta de

    evacuare

    non de fixare

    Racord de reglare admisie aer

    CG_2114 / 0902_2801

    CONDUCTE DE EVACUARE-ADMISIE SEPARATE Acest tip de conduct permite evacuarea produselor de ardere att n exteriorul cldirii, ct i n hornuri de evacuare separate. Admisia de aer comburant poate fi efectuat ntr-o zon diferit fa de cea n care e situat conducta de evacuare. Kit-ul separator conine un adaptor pentru conducta de evacuare (100/80) i un adaptor pentru conducta de admisie aer. Pentru adaptorul pentru conducta de admisie aer montai uruburile i garniturile nlturate n prealabil de pe capac.

    CO2%

    Model

    (L1+L2)

    Poziie Registru

    Evacuare REDUCIE

    A G20 G31

    0 4 A 4 14 B

    24 F

    14 23 C

    Nu

    6,4

    7,1

    Primul cot de 90 nu este inclus n calculul lungimii maxime disponibile. Cotul de 90 permite racordarea centralei la conducta de evacuare-admisie indiferent de direcie, deoarece poate fi rotit la 360. n plus, poate fi utilizat i ca un cot suplimentar, alturi de conduct sau de un cot de 45.

    Un cot de 90 reduce lungimea total a conductei cu 0,5 metri. Un cot de 45 reduce lungimea total a conductei cu 0,25 metri.

    ATENIE Conductele de evacuare gaze arse i admisie aer (C52) ale centralei trebuie s aib urmtoarea lungime maxim:

    - conducta de admisie: Lmax= 8m - conducta de evacuare: Lmax= 15m

    Reglarea registrului pentru sistemul se- parat

    Reglarea acestui registru e necesar pentru a optimiza performanele i parametrii de ardere. Racordul de admisie aer (care poate fi montat n partea dtreapt sau stng a condictei de evacuare) poate fi rotit pentru a regla aerul n exces, n funcie de lungimea total a conductelor de evacuare i de admisie pentru aerul comburant. Rotii acest registru n sens antiorar pentru a micora cantitatea de aer comburant n exces i viceversa pentru a o mri. Pentru a optimiza combustia se poate folosi un dispozitiv de analizare a produselor de ardere, pentru a msura coninutul de CO2 din gazele arse la puterea termic maxim, reglnd aerul treptat pentru a atinge valoarea de CO2 din tabelul de mai jos, dac la analiz se constat o valoare mai sczut. Pentru a monta n mod corect acest dispo- zitiv, consultai instruciunile care nsoesc accesoriul.

    Adaptor p

    Ma

    Figura 8

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO147

    0503_0911/CG1644

    0503_2201/CG1643

    0803_0603 / C

    G_2046

    16.4 DIMENSIUNI TOTALE CONDUCT DE EVACUARE DUBL

    16.5 EXEMPLE DE INSTALARE CU CONDUCTE DE EVACUARE ORIZONTALE SEPARATE IMPORTANT - Asigurai o pant minim n jos, spre exterior, de 1 cm pentru fiecare metru de lungime al conductei. Dac montai un kit de colectare a condensului, conducta de drenare trebuie s fie nclinat spre central.

    L max = 10 m L1 max = 8 m; L2 max = 15 m NB: Pentru tipul C52, conductele de admisie a aerului comburant i de evacuare a produselor de ardere nu trebuie poziionate pe perei opui ai cldirii.

    Dac lungimea conductei de evacuare e mai mare de 6 m, kit-ul de colectare a condensului (livrat ca accesoriu) trebuie s fie montat lng central.

    16.6 EXEMPLE DE INSTALARE CU CONDUCTE DE EVACUARE VERTICALE SEPARATE

    L max = 12 m L max = 11 m

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO148

    0712_1208 / C

    G_2008

    IMPORTANT: Dac instalai o singur conduct de evacuare, asigurai-v c e izolat corespunztor (de ex. cu vat de sticl) n punctele n care aceasta traverseaz pereii cldirii. Pentru instruciuni mai detaliate privind montarea accesoriilor, consultai datele tehnice care nsoesc accesoriile respective.

    17. CONECTAREA LA REEAUA ELECTRIC Sigurana electric a aparatului este asigurat numai cnd acesta este racordat corect la o instalaie de mpmntare eficient, racordarea fiind efectuat conform normelor de siguran n vigoare privitoare la instalaii. Centrala trebuie conectat electric la o reea de alimentare 230 V monofazic + mpmntare cu ajutorul cablului trifilar din dotare, respectndu-se polaritatea LINIE-NEUTRU. Conectarea trebuie efectuat prin intermediul unui ntreruptor bipolar cu o deschidere a contactelor de cel puin 3 mm. n cazul nlocuirii cablului de alimentare, a se utiliza un cablu de tip HAR H05 VV-F 3x0,75 mm2 cu diametru maxim de 8 mm.

    ... Accesul la panoul de borne de alimentare ntrerupei tensiunea n central cu ajutorul ntreruptorului bipolar; desfacei cele dou uruburi de fixare a panoului de comand la central; rotii panoul de comand; ndeprtai capacul pentru a avea acces la zona conexiunilor electrice (figura 9).

    Fuzibilul de tip rapid de 2 A este ncorporat n panoul de borne de alimentare (pentru control sau substituire, extragei suportul fuzibi-

    lului, de culoare neagr).

    IMPORTANT: respectai polaritatea n alimentare L (LINIE) - N

    (NEUTRU). (L) = Linie (maro) (N) = Neutru (albastru)

    = mpmntare (galben-verde) (1) (2) = Contact pentru termostat ambiental

    Figura 9

    18. CONECTAREA TERMOSTATULUI AMBIENTAL

    Accedei la de borne de alimentare (figura 9) conform descrierii de la capitolul precedent; ndeprtai puntea de curent existent pe bornele (1) i (2); introducei cablul cu dou fire prin orificiul special i conectai-l la aceste dou borne.

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO149

    0901_1101

    19. MODALITI DE NLOCUIRE A GAZULUI Personalul calificat (al Serviciului de Asisten Tehnic autorizat) poate adapta aceast central pentru funcionarea cu gaz natural (G. 20) sau cu gaz lichid (G. 31).

    Modalitile de calibrare a regulatorului de presiune sunt uor diferite, n funcie de tipul de valv de gaz utilizat (HONEYwELL sau SIT, vezi figura 10).

    Operaiile de efectuat sunt urmtoarele:

    A) nlocuirea injectoarelor arztorului principal; B) schimbarea tensiunii la modulator; B) o nou reglare de max. i min. a regulatorului de presiune.

    A) nlocuirea injectoarelor Scoatei cu grij arztorul principal din locaul su; nlocuii injectoarele arztorului i strngei-le bine pentru a evita scurgerile de gaz. Diametrele injectoarelor sunt specificate n tabelul

    2.

    B) Modificarea tensiunii modulatorului

    Reglai parametrul F02 n funcie de tipul de gaz utilizat, aa cum se descrie n capitolul 21;

    C) Reglarea dispozitivului de reglare a presiunii (Figura 10) Conectai priza de presiune pozitiv a unui manometru diferenial (dac e posibil, pe baz de ap) la priza de presiune (Pb) a valvei de

    gaz. Numai pentru modelele cu camer etan: conectai priza negativ a manometrului la un racord n T care s permit conectarea mpreun a prizei de compensare a centralei, a prizei de compensare a valvei de gaz (Pc) i a manometrului. (Aceeai msurtoare poate fi efectuat prin conectarea manometrului la priza de presiune (Pb) dup ce a fost scos panoul frontal al camerei etane.) O msurare a presiunii la arztoare efectuat prin metode diferite de cele descrise s-ar putea dovedi eronat, ntruct nu ar ine cont de presiunea joas creat de ventilator n camera etan.

    C1) Reglarea la putere nominal: deschidei robinetul de gaz i setai centrala n regimul Iarn; deschidei robinetul de admisie a apei menajere la un debit de cel putin 10 litri pe minut sau, n orice caz, asigurai-v c exist cerere

    maxim de cldur; ndeprtai capacul modulatorului; reglai urubul din alam (a) pn la obinerea valorilor de presiune indicate n tabelul 1; verificai ca presiunea dinamic de alimentare a centralei, msurat la priza de presiune (Pa) a valvei de gaz s fie cea corect (30 mbar

    pentru propan sau 20 mbar pentru gaz natural).

    C2) Reglarea la putere redus: deconectai cablul de alimentare al modulatorului i desfacei urubul (b) pn la atingerea valorii presiunii corespunztoare puterii reduse

    (vezi tabelul 1); reconectai cablul; montai capacul modulatorului i strngei-l.

    C3) Verificri finale Aplicai plcua suplimentar cu datele tehnice, care indic tipul de gaz i reglrile efectuate.

    VALV SIT - SIGMA 845 VALV HONEywELL - VK 4105 M

    Figura 10

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO150

    24 24 F G20 G31 G20 G31

    Putere nominal 2,78 m3/h 2,04 kg/h 2,73 m3/h 2,00 kg/h Putere redus 1,12 m3/h 0,82 kg/h 1,12 m3/h 0,82 kg/h p.c.i. 34,02 MJ/m3 46,34 MJ/kg 34,02 MJ/m3 46,34 MJ/kg

    Tabel injectoare arztor 24 24 F Gaz utilizat G20 G31 G20 G31

    diametru injector (mm) 1,18 0,74 1,35 0,85 Presiunea la arztor (mbar*) PUTERE REDUS

    2.3 6,3 2,3 5,4

    Presiunea la arztor (mbar*) PUTERE NOMINAL

    13,1 35,3 11,3 28,5

    nr. de injectoare 13 11 * 1 mbar = 10,197 mm H

    2O

    Tabelul 1

    Consum 15C-1013 mbar Tabelul 2

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO151

    0605_2204 / C

    G_1808

    20. VIZUALIZAREA PARAMETRILOR PE AFIAJ (FUNCIE INFO) Apsai timp de cel puin 5 secunde tasta i, pentru a vedea pe afiaul de pe panoul frontal al centralei unele informaii privind funcionarea centralei.

    NOT: cnd funcia INFO este activ, pe afiaj (figura 12) este vizualizat inscripia A00 care se alterneaz cu valoarea de temperatur din turul centralei:

    Figura 12

    Apaati tastele (+/-) pentru a vizualiza urmtoarele informaii: A00: valoarea (C) actual a temperaturii din circuitul de ap menajer; A01: valoarea (C) actual a temperaturii externe (cu sonda extern conectat); A02: valoarea (%) curentului la modulator (100% = 230 mA METAN - 100% = 310 mA GPL); A03: valoarea (%) domeniului de putere (MAX R); A04: valoarea (C) temperaturii de setpoint n circuitul de nclzire; A05: valoarea (C) actual a temperaturii din turul circuitului de nclzire; A06: valoarea (C) temperaturii de setpoint din circuitul de ap menajer; A07: valoarea (%) semnalului flcrii (0-100%); A08: valorea (l/min x 10) debitului de ap menajer A09: ultima eroare care s-a verificat la central.

    Aceast funcie rmne activ timp de 3 minute. Este posibil s ntrerupei anticipat funcia INFO prin apsarea timp de cel puin 5 secunde a tastei (i) sau prin deconectarea centralei de la reeaua electric.

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO152

    21. SETAREA PARAMETRILOR Pentru a seta parametrii de funcionare a centralei apsai simultan tastele ( ) i ( ) timp de cel puin 6 secunde. Cnd funcia este activ, pe afiaj apare inscripia F01 care se alterneaz cu valoarea parametrului selectat.

    Modificarea parametrilor

    Pentru a derula parametrii apsai tastele (+/ ); Pentru a modifica valoarea unui singur parametru apsai tastele (+/ ); Pentru memorarea valorii apsai tasta ( ), pe afiaj apare inscripia MEM. Pentru a iei din funcie fr memorare apsai tasta (i) , pe afiaj apare inscripia ESC.

    Valori setate din fabrica

    Descrierea parametrilor

    24 F 24 F01 Tipul de central

    10 = camer etan - 20 = camer deschis

    10

    20

    F02 Tipul de gaz 00 = METAN - 01 = GPL

    00 sau 01

    F03 Sistem hidraulic 02 F04/ F05 Setare releu programabil 1 i 2 (vezi instruciunile pentru Serviciul de Asisten)

    00 = nici o funcie asociat

    00

    F06 Valoarea maxim setpoint (C) nclzire 00 = 85C - 01 = 45C

    00

    F07 Configuraie intrare prioritate ap menajer 02 F08 Putere max. nclzire (0-100%) 100 F09 Putere max. ap cald menajer (0-100%) 100 F10 Putere min. nclzire (0-100%) 00 F11 Timp de ateptare nainte de o nou aprindere n modul nclzire

    (00-10 minute) - 00=10 secunde

    03

    F12 Diagnosticare (vezi instruciunile pentru Serviciul de Asisten) --

    F13 Tipul schimbtorului 00 = 275 mm 01 = 225 mm

    01

    00

    F14

    Test de verificare a corectitudinii poziiei sondei circuitului de ap menajer 00 = Dezactivat 01 = Activat permanent

    01

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO153

    22. DISPOZITIVE DE REGLARE I SIGURAN Centrala este fabricat astfel nct s respecte toate Normativele europene de referin i n particular este dotat cu:

    Presostat aer (modelele 24 F) Acest dispozitiv permite aprinderea arztorului numai n caz de eficien perfect a circuitului de evacuare a gazelor arse. n cazul prezenei uneia dintre aceste anomalii: extremitate de evacuare obturat; tub venturi obturat; ventilator blocat; conexiune tub venturi - presostat ntrerupt,

    centrala rmne n ateptare, iar pe afiaj apare codul de eroare E03 (vezi tabelul de la seciunea 10).

    Termostat gaze arse (model 24) Acest dispozitiv, al crui senzor este poziionat n partea stng a hotei de evacuare a gazelor arse, ntrerupe fluxul de gaz ctre arztorul principal n cazul conductei de evacuare a gazelor arse obturate sau n lipsa tirajului. n aceast situaie, centrala se blocheaz, iar pe afiaj apare codul de eroare 03E (seciunea 10). Pentru o repornire imediat a centralei, eliminai cauza intrrii n funciune a dispozitivului i apaati tasta ( ) timp de cel puin 2 secunde.

    Este interzis dezactivarea acestui dispozitiv de siguran

    Termostat de siguran Acest dispozitiv, al crui senzor este plasat pe turul circuitului de nclzire, ntrerupe fluxul de gaz ctre arztor n caz de supranclzire a apei din circuitul primar. n aceste condiii, centrala se blocheaz i numai dup nlturarea cauzei intrrii n funciune a dispozitivului este posibil repornirea prin apsarea tastei ( ) timp de cel puin 2 secunde.

    Este interzis dezactivarea acestui dispozitiv de siguran

    Detector cu ionizare n flacr

    Electrodul de detectare a flcrii, situat n partea dreapt a arztorului, garanteaz sigurana n cazul lipsei de gaz sau de aprindere incomplet a arztorului. n aceste condiii centrala se blocheaz dup 3 ncercri de aprindere. Pentru a restabili condiiile normale de funcionare apsai tasta ( ), timp de cel puin 2 secunde.

    Presostat hidraulic Acest dispozitiv permite aprinderea arztorului principal numai dac presiunea n instalaie este mai mare de 0,5 bari.

    Postcirculaie pomp pentru circuitul de nclzire Funcionarea suplimentar a pompei, obinut electronic, dureaz 180 de secunde i se activeaz cnd centrala funcioneaz n modul nclzire, dup stingerea arztorului n urma intrrii n funciune a termostatului ambiental.

    Postcirculaie pomp pentru circuitul de ap cald menajer Funcionarea suplimentar a pompei, obinut electronic, dureaz 30 de secunde i se activeaz cnd centrala funcioneaz n modul Ap cald menajer, dup stingerea arztorului n urma intrrii n funciune a sondei.

    Dispozitiv antinghe (circuit de nclzire) Unitatea electronic a centralei este prevzut cu o funcie antinghe n circuitul de nclzire care, la o temperatur a apei din turul instalaiei mai mic de 5C, face s funcioneze arztorul pn la atingerea n tur a unei valori de 30C. Aceast funcie este operaional dac centrala este alimentat cu energie electric, dac exist gaz i dac presiunea n instalaie este cea prescris.

    Lipsa circulaiei apei n circuitul primar (posibil blocare a pompei Dac apa din circuitul primar nu circul sau circul insuficient, centrala se blocheaz, iar pe afiaj apare codul de eroare 25E (seciunea 10).

    Antiblocare pomp Dac lipsete cererea de cldur timp de 24 de ore consecutive, pompa intr n funciune automat pentru 10 secunde. Aceast funcie este activ dac centrala este alimentat cu energie electric.

    Valv de siguran hidraulic (circuit de nclzire) Acest dispozitiv, reglat la 3 bari, e utilizat pentru circuitul de nclzire.

    Se recomand s racordai valva de siguran la o conduct de evacuare cu sifon. Este interzis utilizarea valvei pentru golirea circuitului de nclzire.

    NOT: apa cald menajer e asigurat chiar dac sonda NTC a circuitului de ap menajer e deteriorat. n acest caz, controlul temperaturii este efectuat cu ajutorul sondei de pe tur.

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO154

    23. POZIIONAREA ELECTRODULUI DE APRINDERE I DETECTARE A FLCRII

    D EBI

    T mH 2

    O

    9912070100

    0902_0606

    Figura 13

    24. VERIFICAREA PARAMETRILOR DE COMBUSTIE Pentru msurarea randamentului de combustie i a calitii produilor de combustie, centrala este dotat cu dou prize. O priz este conectat la circuitul de evacuare a gazelor arse i permite determinarea calitii produilor de combustie i a randamentului de combustie. Cealalt este conectat la circuitul de admisie a aerului i permite verificarea unei eventuale recirculaii a produilor de combustie n cazul conductelor coaxiale. Prin priza conectat la circuitul gazelor arse pot fi msurai urmtorii parametri:

    temperatura produilor de combustie; concentraia de oxigen (O2) sau de dioxid de carbon (CO2); concentraia de monoxid de carbon (CO).

    Temperatura aerului comburant trebuie msurat la priza conectat la circuitul de admisie a aerului introducndu-se sonda corespunztoare la circa 3 cm.

    NOT: Pentru reglarea puterii nominale, vez capitolul 19 (C1) Pentru modelele de centrale cu tiraj natural, se va realiza un orificiu pe conducta de evacuare gaze arse, la o distan de la central egal cu dublul diametrului interior al conductei. Prin acest orificiu pot fi msurai urmtorii parametri:

    temperatura produilor de combustie; concentraia de oxigen (O2) sau de dioxid de carbon (CO2); concentraia de monoxid de carbon (CO). Temperatura aerului comburant se va msura aproape de punctul n care aerul intr n central. Orificiul, care va fi realizat de rspunztorul de punerea n funciune a instalaiei, trebuie s fie sigilat astfel nct conducta de evacuare a produilor de ardere s fie etan n timpul funcionrii normale.

    25. CARACTERISTICI DEBIT/NLIME DE POMPARE

    Pompa utilizat este o pomp cu o nlime mare de pompare, potrivit pentru instalaii de nclzire de orice tip, cu un singur sau cu dou tuburi. Valva automat de aerisire, ncorporat n pomp, permite evacuarea rapid a aerului din instalaia de nclzire.

    Diagrama 1 NLIME DE POMPARE l/h

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO155

    26. CONECTAREA SONDEI EXTERNE

    0505_3002

    Printre cablurile care ies din panou sunt dou cabluri de culoare ROIE dotate cu conectori de tip faston. Conectai sonda extern la capetele acestor dou cabluri. Cu sonda extern conectat, este posibil modificarea curbei kt (Diagrama 1), prin apsarea tastelor +/- .

    curbe kt TM

    TM = Interval temperaturi tur Te Te = temperatur exterioar Diagrama 2

    27. NTREINERE ANUAL

    n scopul asigurrii unei eficiene optime a centralei, este necesar efectuarea anual a urmtoarelor verificri: verificarea aspectului i etaneitii garniturilor circuitului de gaz i ale circuitului de combustie; verificarea strii i poziiei corecte a electrozilor de aprindere i detectare a flcrii; verificarea strii arztorului i a fixrii acestuia; verificarea eventualelor impuriti prezente n interiorul camerei de combustie. Pentru curare utilizai un aspirator; verificarea reglrii a valvei de gaz; verificarea presiunii din instalaia de nclzire; verificarea presiunii vasului de expansiune; verificarea faptului c ventilatorul funcioneaz corect; verificarea faptului c conductele de evacuare/admisie nu sunt obturate.

    ATENIE nainte de efectuarea oricrei intervenii asigurai-v c centrala este deconectat de la reeaua electric. Dup terminarea operaiilor de ntreinere readucei selectoarele i/sau parametrii de funcionare a centralei n poziiile origina- le.

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO156

    28. DIAGRAM FUNCIONAL CIRCUITE

    CG_2110 / 0902_0607

    24 F

    Figura 17

    Tur nclzire Ieire ap

    menajer

    Gaz Intrare ap

    menajer

    Retur nclzire

    Legend:

    1 Sond NTC circuit de ap menajer

    2 Robinet de evacuare central

    3 Robinet de ncrcare central

    4 Presostat hidraulic

    5 Valv de gaz

    6 Ramp gaz cu injectoare

    7 Schimbtor ap-gaze arse

    8 Hot gaze arse

    9 Ventilator

    10 Priz de presiune pozitiv

    11 Priz de presiune negativ

    12 Presostat aer

    13 Sond NTC circuit de nclzire

    14 Termostat de siguran

    15 Electrod de aprindere/detectare a flcrii

    16 Arztor

    17 Vas de expansiune

    18 Pomp cu separator de aer

    19 Manometru

    20 Valv de siguran

    21 By-pass automat

    22 Senzor prioritar ap menajer

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO157

    0809_0202 / C

    G_2082

    24

    Figura 18

    Tur nclzire Ieire ap

    menajer

    Gaz Intrare ap

    menajer

    Retur nclzire

    Legend:

    1 Sond NTC circuit de ap menajer

    2 Robinet de evacuare central

    3 Robinet de ncrcare central

    4 Presostat hidraulic

    5 Valv de gaz

    6 Ramp gaz cu injectoare

    7 Schimbtor ap-gaze arse

    8 Hot gaze arse

    9 Termostat gaze arse

    10 Sond NTC circuit de nclzire

    11 Termostat de siguran

    12 Electrod de aprindere/detectare a flcrii

    13 Arztor

    14 Vas de expansiune

    15 Pomp cu separator de aer

    16 Manometru

    17 Valv de siguran

    18 By-pass automat

    19 Senzor prioritar ap menajer

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO158

    ELECTROD DE APRINDERE/ DETECTARE A FLCRII

    TERMOSTAT

    POMP

    VENTILATOR SENzOR PRIORITA AP MENAJER

    SOND NTC CIRCUIT

    DE AP MENAJE

    SONDA EXTERN PRESOSTAT HIDRAULIC

    TERMOSTAT

    DE SIGURAN

    PRESOSTAT AER

    CG_2113 / 0902_0609

    29. DIAGRAM CUPLARE CONECTORI

    24 F

    R

    R

    TERM. AMB./CONTR. LA DISTAN

    SOND NTC CIR- CUIT DE NCLzIRE

    Culoare cabluri

    C = Albastru M = Maro N = Negru R = Rou G/V = Galben/Verde B = Alb V = Verde

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO159

    ELECTROD DE APRINDERE/ DETECTARE A FLCRII

    TERMOSTAT

    POMP

    SENzOR PRIORITA AP MENAJER

    SOND NTC CI DE AP MEN

    SONDA

    EXTERN PRESOSTAT HIDRAULIC

    TERMOSTAT

    DE SIGURAN

    TERMOSTAT GAzE ARSE

    CG_2116 / 0902_2002

    24

    R

    RCUIT AJER

    TERM. AMB./CONTR. LA DISTAN

    SOND NTC CIR- CUIT DE NCLzIRE

    Culoare cabluri

    C = Albastru M = Maro N = Negru R = Rou G/V = Galben/Verde B = Alb V = Verde

  • INSTRUCIUNI DESTINATE INSTALATORULUI

    926.275.1 - RO160

    30. CARACTERISTICI TEHNICE

    Model qUASAR D 24 F 24 Categorie II2H3P II2H3P Debit termic nominal kw 25,8 26,3 Debit termic redus kw 10,6 10,6 Putere termic nominal kw 24 24 kcal/h 20.600 20.600 Putere termic redus kw 9,3 9,3 kcal/h 8.000 8.000 Randament conform Directivei 92/42/CEE Presiune maxim a apei n circuitul termic bar 3 3 Capacitate vas de expansiune l 6 6 Presiune vas de expansiune bar 0,5 0,5

    Presiune maxim ap n circuitul de ap menajer

    bar

    8

    8

    Presiune minim dinamic ap n circuitul de ap menajer bar 0,15 0,15 Debit minim ap n circuitul de ap menajer l/min 2,0 2,0 Producie ap menajer cu t = 25 C l/min 13,7 13,7 Producie ap menajer cu t = 35 C l/min 9,8 9,8 Debit specific (*) l/min 11 11 Interval de temperatur circuit de nclzire C 30/76 30/76 Interval de temperatur circuit de ap menajer C 35/55 35/55 Tip C12-C32-C42-C52-C82-B22 B11BS Diametru conduct de evacuare concentric mm 60 - Diametru conduct de admisie concentric mm 100 - Diametru conduct de evacuare dublat mm 80 - Diametru conduct de admisie dublat mm 80 - Diametru conduct de evacuare mm - 120 Debit masic max. gaze arse kg/s 0,016 0,021 Debit masic min. gaze arse kg/s 0,016 0,018 Temperatur max. gaze arse C 149 120 Temperatur min. gaze arse C 119 86 Clas NOx 3 3 Tip de gaz G20 G20 G31 G31 Presiune de alimentare cu gaz metan mbar 20 20 Presiune de alimentare cu gaz propan mbar 37 37

    Frecven de alimentare cu energie electric Hz 50 50

    Putere electric nominal w 130 80 Greutate net kg 31 29 Dimensiuni nlime mm 730 730 lime mm 400 400 adncime mm 299 299 Grad de protecie contra umiditii i penetrrii apei (**) IP X5D IP X5D (*) Conform EN 625 (**) Conform EN 60529

    wESTEN, n efortul de a-i mbunti mereu produsele, i rezerv dreptul de a modifica datele coninute n acest document n orice moment i fr preaviz. Aceste instruciuni au doar scopul de a furniza clienilor informaii privitoare la produs i n nici un caz nu pot fi considerate un contract cu o ter parte.