meganet vme-manpack jammer
TRANSCRIPT
-
8/9/2019 Meganet VME-ManPack Jammer
1/15
VME-MANPACK SYSTEM
MMEEGGAANNEETTCCOORRPPOORRAATTIIOONNSSEECCUURREEIINNFFOORRMMAATTIIOONNIISSPPOOWWEERR
World Trade Center
350 S. Figueroa St # 450
-
8/9/2019 Meganet VME-ManPack Jammer
2/15
2 February 7, 2008
The VME-ManPack jamming system is Dual band (cellular GSM900/HGSM1800).
a. GSM900 bandFrequency Band 925 960 MHz
RF Output Power 80 Watt
Frequency Band Spectrum Measurement Graph:
Harmonics Spectrum Measurement Graph:
-
8/9/2019 Meganet VME-ManPack Jammer
3/15
3 February 7, 2008
Antenna specification
Antenna type Omnidirectional, dipole
Antenna gain 5dBi
Antenna frequency band 925 - 960MHz
VSWR 1:1.5
Antenna Pattern:
-
8/9/2019 Meganet VME-ManPack Jammer
4/15
4 February 7, 2008
HGSM1800 band
Frequency Band 1805 1880 MHz
RF Output Power 80 Watt
Frequency Band Spectrum Measurement Graph:
Harmonics Spectrum Measurement Graph:
-
8/9/2019 Meganet VME-ManPack Jammer
5/15
5 February 7, 2008
Antenna specification
Antenna type Omnidirectional, dipole
Antenna gain 5dBi
Antenna frequency band 1805 - 1880MHzVSWR 1:1.5
Antenna Pattern:
-
8/9/2019 Meganet VME-ManPack Jammer
6/15
6 February 7, 2008
The VME-ManPack system is the RF active transmitting system with no receiver channel.
Frequency coverage @ RF Output power:
925 - 960MHz @ 80Watt (GSM900 channel)
1805 - 1880MHz @ 80Watt (HGSM1800 channel)
No limitation of the threat number for simultaneous jamming.
The system can jam simultaneously all threats in the coverage area within the frequency bands.
Barrage jamming technology, frequency modulated high density white noise, continuous within each
frequency band.
Spectrum and harmonics measurement.
RF Band Pass Filter technology using.
Harmonics limits: For second harmonic min -30dB attenuation
For third harmonic min -40dB attenuation
For four and upper min -50dB attenuation.
Fully operational. Ready for immediate deployment.
Manufacturer tuned jamming system with no programmable function.
No Windows based secondary data transfer device is present.
No programmable/reprogrammable/updatable functions for the system.
System specification:
Total System Dimensions (with antennas) 1440x324x152 mmSystem Dimensions (without antennas) 498x324x120 mm
Full System weight (with 6 rechargeable batteries and two antennas) approx. 17kg
System Weight (without batteries and antennas) approx. 7kg
System dimensions without antenna installation:
-
8/9/2019 Meganet VME-ManPack Jammer
7/15
7 February 7, 2008
-
8/9/2019 Meganet VME-ManPack Jammer
8/15
8 February 7, 2008
System exterior diagram without antenna installation
-
8/9/2019 Meganet VME-ManPack Jammer
9/15
9 February 7, 2008
System Accessories:
a. Batteries
Battery type UBI 2590 (Li-Ion rechargeable)
Battery number per system 6
Battery Charger typeBattery Specifications
Maximum Voltage: 16.4 or 32.8 Volts
Typical Voltage: 14.4 or 28.8 Volts
Final Voltage: 12 or 24 Volts
Capacity: 28.8 V Mode: 6 Ah @ 500 mA @ 23 C14.4 V Mode: 12 Ah @ 1.0 A @ 23 C
Max. Discharge: 28.8 V Mode: 6 A continuous14.4 V Mode: 12 A continuous
Pulse Capacity: 28.8 V Mode: 18 A / 5 seconds14.4 V Mode: 36 A / 5 seconds
Varies according to pulse characteristics, temperature, cell history, and the application. ConsultUltralife.
Energy: 173 Wh
Energy Density: 120 Wh/kg, 200 Wh/I
Weight: 1440 Grams
Cycle Life: > 300 cycles @ C/5 to 80% of initial capacity
Memory: No Memory Effect
Operating Temp.: -20 C to 60 C
Storage Temp.: -20 C to 60 C
Self Discharge: < 5 % per Month
Exterior/Housing: Hard plastic, black (Noryl N190X-701)
Terminals/Connector: SC-C-179495 (see note 2)State of ChargeIndicator:
LCD display
Safety: To prevent injury or burns do not disassemble, short circuit or dispose of in fire.Material Safety Datasheet - MSDS041.
Transportation: Excepted - U.S.; Class 9 - Int'l. See note 1.
Harmonized Tariff Code: 8507.80.00.00
Battery Dimensions:
-
8/9/2019 Meganet VME-ManPack Jammer
10/15
10 February 7, 2008
Charging:
Charge each section at constant voltage of 16.4 (16.8 max) Volts in a temperature range of 5 to 38C, limiting currentto 3.0 A max, for 3 hours. Both sections can be charged in parallel, however, charge time will increase to 6 hours. Referalso to Safety Guide UBI-5112.
SYSTEM WITHOUT BATTERIES SYSTEM WITH
BATTERIES
-
8/9/2019 Meganet VME-ManPack Jammer
11/15
11 February 7, 2008
b. Battery Charger
Battery charger type CH0002, CH0003 or CH0004
-
8/9/2019 Meganet VME-ManPack Jammer
12/15
12 February 7, 2008
c. Antennas
Antenna type Dipole, Omnidirectional
Frequency Bands GSM900 (925-960 MHz) or HGSM1800 (1805-1880
MHz)
Total antenna number per system 2 (GSM900 and HGSM1800)
Antenna dimensions (with holder) 1000x62x35 mmAntenna dimensions (without holder) 1000xD32 mm
Antenna weight 300 g
-
8/9/2019 Meganet VME-ManPack Jammer
13/15
13 February 7, 2008
External DC input (+28VDC) through DC input connector on the top of the system case.
Total power consumption for the system is 600VA (21A @ +28VDC)
External power supply (+28VDC @ 750Watt)
Power supply spec:
Input voltage 90-260 VAC
Power consumption 800VA
Output voltage +28VDC
Output power 750Watt
Dimensions 30x22.5x13.2 cm (Pelican military 1400 case)
Weight 5 kg
System status indication:
- Transmitting status led per each channel:
RF output power feedback, PA output module failure
Antenna VSWR failure
- Battery status buzzer
Discharging/empty battery status
No Remote Control included
Operating training Approx 2-3 hours.
Maintenance training
Organizational level one day
Intermediate level two days
Depot level one week
-
8/9/2019 Meganet VME-ManPack Jammer
14/15
14 February 7, 2008
Automatic, continuous BIT implemented in the system:
- PA module RF output power test (Transmitting status led red light)
- Antenna VSWR test (Transmitting status led red light)
Power-on BIT:
- Discharging/status battery test (Battery status buzzer - beeper)
System BIT level.
System operating delay:
Power-on from a cold start less then 1ms
Stand-by state less then 1msRestart/warm start immediately
No system capability to user-initiated zeroize (zeroing).
Average estimated time for preventive maintenance 6 hours
(System cleaning, cooling system cleaning, battery charging)
No special skills or tools required.
Mean Time Between Failures (MTBF) of the system 10000 hours
-
8/9/2019 Meganet VME-ManPack Jammer
15/15
15 February 7, 2008
Operational temperature range -20C+50C
Storage Temperature -50C+65C
Lower temperature failures:
- Battery discharging
- Operating time reducing
Upper temperature failures:
- RF output power reducing
- Frequency band moving
- Battery discharging
- Operating time reducing
- System overheating and burning
Components temperature limiting:
- Batteries -20C+60C
- Antennas -20C+50C- PA module -20C+50C
- Cooling system fans -20C+50C
weight and dimensions
65x40x30 cm and 110x20x10 cm (3 kg and 0.5 kg)