microwave link presentation
DESCRIPTION
Microwave Link Presentation in TelecomTRANSCRIPT
-
Microwave Transmission Microwave Range Microwave range starts from .3Ghz to 300Ghz MOST PRACTICAL RANGE FROM 1 GHz TO 100 GHz ALCATEL MW RANGE 7-8-13-15-18-23-25-28-38 GHz ADVANTAGES OF MW1- COST EFFECTIVE. 2- SINGLE POINT MAINTENANCE.3- QUICK DEPLOYMENT ACROSS RIVERS AND MOUNTAINS.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
TYPES OF LINKS
TYPES OF THE LINKS ACCORDING TO CAPACITY
PDH PHYLESIOCHRONOUS DIGITAL HIRARCHY 4E1,16E1,64E1 Alcatel PDH(CM-PAK PROJECT). 4E1,8E1,16E1,32E1.SDH SYHCRONOUS DIGITAL HIRARCHY STM-1,STM-4,STM16,STM-64. PRACTICALLY (Pakistan) USED STM-1 & XPIC(2STM-1)
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
PDHAUDIO FREQUENCY =3.4 Khz INTELIGIBILITY NOT DISTURBEDSAMPLING RATE = 8Khz sample/sec TO AVOID ALISINGBITS PER SAMPLE = 8 bits/sample ENOUGH QUANTIZATION LEVEL TO DESCRIBE THE SIGNALDATA RATE = (8bits/sample )(8khz samples/sec)= 64kbpsE0 = 64kbpsE1 = (32 )(64Kbps) = 2.048 Mbps (32 CHANNELS, FIRST USED FOR SYNCHRONISATION & 16TH SIGNALING)E2 = (4)*E1 = 4 (2.048) = 8.448 MbpsE3 = (4)*E2 = 4(8.448) = 34.36 MbpsE4 = (4)*E3 = 4( 34.36) = 139.264 Mbps.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
SDH
DATA RATE EQUILENT PDHSTM-1 155.52 Mbps 63E1 STM-4 4*155.52 = 622.08 Mbps 252E1STM-16 4*622.08 = 2.488 Gbps 1008E1STM-64 4*2.488 = 9.953 Gbps 4032E1
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
TYPES OF LINKS
1.2 TYPES OF THE LINKS ACCORDING TO CONFIGURATION
1+0 1+11+1 HST (EQUIPMENT PROTECTION)1+1 SD (EQUIPMENT + PATH PROTECTION +BEST METHOD TO MINIMIZE MULTIPATH INTERFERENCE.) 1+1 FD (CHANNEL PROTECTION)TWIN PATH (NODAL SOLUTION)
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
LINK BUDGET IF filter lossRF filter loss
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
MW DISH GAINSDISH GAIN DEPENDS UPON FREQUENCY AND SIZE AND DISH TYPE
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RADIO MODEL
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
OUT PUT POWERTHE KEY IS SYSTEM GAIN
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
EMISSION DESIGNATAR
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
EMISSION DESIGNATAREmission designator
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
FREQUENCY CHANNELS
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
SYSTEM CHARACTERISTICS 4E1 FREQUENCY
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
SYSTEM CHARACTERISTICS 16E1 FREQUENCY
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
CAPACITY, MODULATION & BAND WIDTHAS THE CAPACITY INCREASES WE HAVE TO INCREASE BANDWIDTH OR MODULATION SCHEME, ITS DEPENDS UPON OUR CHOICE HOW TO SELECT BEST CHOICE.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
MODULATION & BANDWIDTHMODULATOR128QAM64QAM16QAM8PSK4PSK2PSKF0+10+20+30+40+50-10-20-30-40-50FREQUENCY (MHz)100MB/ssupposed that100Mb/s data is carried by different levelof the modulator
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
LINK BUDGET EIRP ( EFFECTIVE ISOTROPIC RADIATED POWER)EIRP IS ACTUAL RF POWER MEASURED AS MEASURED IN THE MAIN LOOB.
EIRP = 24 dbm 1.7 dbm + 46.4 dbm = 68.70 dbmRECEIVER SENSITIVITY (RX THRESHOLD) IS THE WEAKEST RF SIGNAL THAT A RADIO NEEDS RECEIVE TO DEMODULATE & DECODE A PACKET OF DATA WITHOUT ERRORS. IT DEPENDS UPON BER THRESHOLD , FREQUENCY BAND , MODULATION SCHEME &. CAPACITY. IN THIS LINK BUDGET IT IS -85dBm.THERMAL FADE MARGIN (SYSTEM OPERATING MARGIN OR FADE MARGIN) FADE MARGIN= RX SIGNAL RECEIVER SENSITIVITY = -28.35 dbm-(-85dbm) = 56.65 dbm.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
LINK BUDGETFREE SPACE LOSS The Free Space Loss is predictable and given by the formula. FSL = 92.4 + 20Log D + 20Log FFSL = Free Space Loss (dB)F = Frequency of transmission (GHz)D = Distance between antennas (km). FSL = 23.52 +24.30+ 92.4 = 140.29RX SIGNAL (dBm) RX Signal = EIRP - FSL + RX Antenna Gain Coax Cable Loss RX Signal = 68.70dBm -140.29 + 46.4 dBi 1.7dBm = -26.86dbm BY INCLUDING REGIONAL EFFECTS (PATH DEPENDENT LOSSES) RSL = -26.86 -1.46 = 28.32 dBm.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
LINK BUDGETWhat Is the Minimum SOM(FADE MARGIN) Needed?Regarding the minimum SOM needed, there is no absolute answer to this question, but the higher it is, the better. Most agree that 20 dB or more is quite adequate. Some think as low as 14 dB is still good.POLARIZATION ORIENTATION OF ELECTRIC COMPANENT OF EM WAVE WITH RESPECT TO GROUND TYPES USED IN MW LINKS HORIZONTAL VERTICAL CHOICE CRITERIA : VERTICAL POLARIZATION IS PREFFERED BECAUSE IT IS LESS PRONE TO NOISE & FADING, BUT TO AVOID INTERFERENCE WE ALSO USE HORIZONTAL POLARIZATION.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IDU LEDs & FUNCTIONS.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
LEDs FUNCTIONSON GREEN WHEN POWERED ON ODUW ( OUT DOOR UNIT WORKING) GREEN WHEN CARRYING TRAFFICRDI (REMOTE DEFECT INDICATION) RED WHEN THERE IS ANY MINOR OR MAJOR ALARM ON FAR ENDLDI (LOCAL DEFECT INDICATION) RED WHEN THERE IS ANY MINOR OR MAJOR ALARM ON NEAR ENDMIN (MINOR) RED MINOR ALARMSMAJ (MAJOR) RED MAJOR ALARMS
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
LEDs FUNCTIONSEOW (ENGINEERING ORDER WIRE) EOW IS COMMUNICATION PATH FOR VOICE OR DATA THIS IS TRI STSTE LED 1- GREEN ENGINEERING ORDER WIRE FREE. 2- YELLOW ENGINEERING ORDER WIRE BUSY. 3- YELLOW BLINKING RECEVING A CALLATTD (ATTENDED) YELLOW IT IS ON WHEN ACKNOWLEDGEMENT BUTTON HAS BEEN PUSHED
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IDUMAIN IDU
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IDU ACKNOWLEDGEMENT (PUSH BUTTON) THIS PUSH BUTTON IS USED FOR CALL .IT TURNS OFF LEDs MAJ/MIN AND TURN ON YELLOW LED.LAMP TEST (PUSH BUTTON) IT IS USED TO VERIFY THAT LEDS ARE WORKING PROPERLY OR NOT. RESET (PUSH BUTTON) IT IS USED FOR THE RESET .
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IDUTPH ( TELEPHONE PORT RJ-11) EOW TELEPHONE RJ11 PORT.OS (OPERATING SYSTEM)10/100 base-T RJ-45 PORT ETHERNET CRAFT TERMIAL ACCESS. TWO LEDs ON IT 1- GREEN ETHERNET LINK IS UP 2- ORANGE BLINKING TX OR RX ACTIVITY IND (DEBUG) FOR FACTORY USE ONLY OS & IND BOTH ARE 10/100 base-T INTERFACE(100MBPS OR 10MBPS OVER TWISTED PAIR CABLEECT (EQUIPMENT CRAFT TEMINAL) RS-232 INTERFACE 9 PIN D TYPE FEMALE CONNECTOR
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IDU8E1/DS1 ( 37 PIN D-SUB FEMALE CONNECTOR) 1-8E1/DS1 TRIBUTRIES ACCESS.ESC (ENGINEERING SERVICE CHANNEL) 15 PIN FEMALE CONNECTORALM (ALARM HOUSEKEEPING)NMS-G703 USED TO ACCESS NE WITH ADJACENT NE. NMS-V11 USED TO ACCESS NE WITH ADJACENT NE.
SCSI (SMALL COMPUTER SERIAL INTERFACE) 1+1 INTERCONNECTION
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IDUPOWER OPTIONS (3 PIN CONNECTOR) THERE ARE THREE OPTIONS 1- 48 TO 60 VDC 20% (9.6) 2- 24 VDC 20% (4.8) 3- 48 TO 60 VDC 20% (9.6)
WHY WE USE NEGATIVE VOLTAGE ( e.g. -48VDC) ? TO MINIMIZE THE INTERNAL NOISE IN VOLTAGE THE ELECTRON FLOW IS EQUIPMENT TO GROUND SO NOISE POSSIBILITY IS LESS IN + VOLTAGE THE ELECTRON FLOW IS FROM GROUND TO EQUIPMENT SO NOISE POSSIBILITY IS HIGH
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
COMMISSIONINGSTARTING THE CRAFT TERMINAL SUPERVISION ---------> START
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
COMMISSIONINGSHOW EQUIPMENT
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
COMMISSIONINGUSER NAME = initialPassword = initialing
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
commissioning
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
commissioning
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
POWER CONTROL METHODSRTPC (RTPC STANDS FOR RADIO TRANSMITTING POWER CONTROL ATPC (AUTOMATIC TRANSMITTING POWER CONTROL) IN THIS CONFIGURATION WE SELECT THRESHOLD FOR THE POWER CONTROL ATPC MIN POWER 4 dbm ATPC MAX POWER 24dbm RX THRESHOLD LEVEL -50 to-100 dbm ATPC MAX VALUE DEPENDS UPON ACHIEVED RSL AND RX THRESHOLD LEVELMTPC (MANUAL TRANSMITTING POWER CONTROL) IN THIS POWER CONTROL METHOD THE TRANSMITTING POWER IS SET BY DEFAULT TO MAXIMUM VALUE,IF WE WANT TO REDUCE TX POWER WE HAVE TO INTRODUCE ATTENEUATION IN IT.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
ATPC SETTINGS
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
COMMISSIONING
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
SHIFTER & CFSHIFTER & CENTRAL FREQUENCY(CF)
FOR EASY IDENTIFICATION 1&2 ARE CONSIDRED TO BE LOW AND 1P & 2P ARE HIGH SHIFTER = HIGH FREQ LOW FREQUnis of the above entries mhz
Problem on a replaceable Unit Replace the UnitAlarm Replaceable Unit Type Mismatch Mismatch between the installed unit and its software configuration change the software according to unit specs or change the unit.Alarm Internal communication problem connection b/w odu & idu is lostAlarm Version Mismatch Mismatch between the CT software version and the equipment software version. Download the new software version.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
commissioning
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
STATUS CHECKING
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RSL CHECKING
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RSL CHECK
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IF FREQUENCYIF FREQUENCY (INTERMEDIATE FREQUENCE) BAND SPECIFIC ( AM,FM, VESTEGIAL ,MW etc) & EQUIPMENT SPECFIC (Alcatel, NEC, HARRIS etc) TWO MAJOR CLASSES IF TX FREQUENCY = 340 Mhz IF RX FREQUENCY = 140 Mhz & IF TX FREQUENCY = 850 Mhz IF RX FREQUENCY = 450 Mhz
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
IF CABLE CHARACTERISTICSIF TX FREQUENCY = 340 MhzIF RX FREQUENCY = 140 MhzCABLE IMPEDENCE = 50 OhmMAXIMUM LENGTH = 300mTNC CONNCETORS ARE USED AT EACH END.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
MW DISH PARTSREFLECTOR CONVERGE THE INCOMMING WAVES TO FEED HORN & DIVERGE THE OUTGOING WAVES TO REFLECTOR .FEEDHORN THIS IS FEED MECHANISM.SHROUDER ALLIGN THE MISS ALIGN WAVES TO MINIMISE DIFFEREACTION & REFLECTION TO MINIMIZE THE INTEFERENCE.RADOME TO PROTECT THE REFLECTOR & FEED HORN AGAINST DUST, WATER etc.ASSEMBLY TO ATTACHE THE DISH WITH POLE.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
HOW TO UPGRAD FLASH CARDCheck the flash card version. if the flash card is of version 2.0.2 or 2.0.3 then up gradation is required.CD of the required version.Insert the CD & make the path.After up gradation activate the upgraded version.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
HOW TO UPGRAD FLASH CARD
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Abnormal Condition List This option enables you to check if there is any loopback or TX Mute activation.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Abnormal Condition List This option enables you to check if there is any loopback or TX Mute activation.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
TX MUTE This option helps you to avoid interference during Alignment of new link in the congested environment. Also used during alignment of SD links and XPIC links.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
EVENT LOG Event log is very useful for the links which flactuates during night hours,at that time you are not on the site and you want to know the reason of fluctuations .
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
EVENT LOG
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
EVENT LOG
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
Loop Back
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RF LOOP BACK BY RF LOOP BACK YOU CAN CHECK YOUR HARDWARE (IDU,ODU,IF CABLE,CONNECTORS),THAT THEY ARE WORKING PROPERLY
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
TRIBUTRY LOOP BACK BY TRIBUTRY LOOP BACK WE CAN PERFORM BIT ERROR RATE TEST .
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
SAVE CURRENT CONFIGURATION MIB MANAGEMENT MIB INCLUDES ALL THE SYSTEM INFORMATION EXCEPT ROUTING CONFIGURATION DATA,BECAUSE IT IS CONSIDERED TO BE UNIQUE FOR EACH LINK.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
BACK UP 17 BY using this option we can save NE configuration on CT( craft terminal) Write the suitable filename then click on confirm Backup to make the Back up on CT.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RESTORE & ACTIVATE SELECT ONE OF THE BACK UP PRESS Confirm Restore By pressing the Reset previous configuration will be cancelled & new is applied. To activate new configuration click MIB Click activate
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RESET BY SOFTWARE YOU CAN RESET NE FROM THIS OPTION.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
BIT ERROR RATE THRESHOLDBER = ERRORS/TOTAL NUMBER OF BITSEB (Error Block) A block in which one or more bits are in error.ES (Error Second) A second during which an error block (EB) occurs.SES (Severely Error Second) Any second which contains more than 30% error Blocks.BBE (Background block error) An error block which is not part of SES.UAS (Unavailable seconds) Unavailable time begins after 10 consecutive SES.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
PERFORMANCE
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
SES EXPLANATION
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
EQUIPMENT ALARM Alarm Replaceable Unit Problem Problem on a replaceable Unit Replace the UnitAlarm Replaceable Unit Type Mismatch Mismatch between the installed unit and its software configuration change the software according to unit specs or change the unit.Alarm Internal communication problem connection b/w odu & idu is lostAlarm Version Mismatch Mismatch between the CT software version and the equipment software version. Download the new software version.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RADIO ALARMCable LOS Problem on the IDU/ODU link cable or on the ODU itself. Check the cable (disconnected, loose connection, cut, short circuited, defective connector etc) If the alarm remains, change the ODU.Incompatible Frequency Frequency configuration setting incompatible with the ODU specs Adjust the frequency setting with the ODU frequency range or change the ODU.Incompatible PTx (ODU) Output power out of rangeTx fail (ODU) Transmitter failure Replace the ODU
Problem on a replaceable Unit Replace the UnitAlarm Replaceable Unit Type Mismatch Mismatch between the installed unit and its software configuration change the software according to unit specs or change the unit.Alarm Internal communication problem connection b/w odu & idu is lostAlarm Version Mismatch Mismatch between the CT software version and the equipment software version. Download the new software version.
Alcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-LucentAlcatel-Lucent
RADIO ALARMMod fail (ODU) modulator failure Replace the ODULoss of frame & Rx fail (ODU) Loss of incoming frame at the antenna level. Check the received level. Check the remote station Tx path first. Check the local station Rx path. Check the antennas alignment & connection to ODU. Replace defective hardware part if any.High / Low BER High / Low Bit Error Rate at Rx side. Check the received level. Check the remote transmit path and the local receive path (Soft configuration and hardware.Investigate any frequency interference. Replace defective hardware part if any.
Problem on a replaceable Unit Replace the UnitAlarm Replaceable Unit Type Mismatch Mismatch between the installed unit and its software configuration change the software according to unit specs or change the unit.Alarm Internal communication problem connection b/w odu & idu is lostAlarm Version Mismatch Mismatch between the CT software version and the equipment software version. Download the new software version.