MOTOR CIRCUIT PROTECTORS
Modern design to meet the increasing industrial challenges
www.eecontrols.ca
2 Motor Circuit Protectors - MN Series
Motor Protective Circuit BreakerSummary
Motor Protective Circuit Breakers MN32 06
Motor Protective Circuit Breaker MN65 08
Motor Protective Circuit Breakers - Accessories 09
Motor Protective Circuit Breakers - Technical Data 14
Motor Protective Circuit Breaker - Dimensions 20
Motor Protective Circuit Breakers - Overview 04
www.eecontrols.ca
3Motor Circuit Protectors - MN Series
Motor Protective Circuit Breakers of MN line, the best solution for operating and protection of your electric motor.
CharacteristicsType Conventional starter Compact starter
Number of components 3 components (fuse1) + contactor+ termal O/L relay) 1 component (motor circuit breaker termomagnetic)
Short-circuit protection Yes Yes
Switching Yes Yes
Motor overload protection Yes Yes
Reset after short-circuit No Yes
Reset after overload Yes Yes
Overall dimension Larger Smaller
Mounting time Long Short
Scale cover No Yes (with accessory)
Safety disconnect for maintenance Fuse removal Padlock on handle/button in OFF position
Operational status signalling No Yes
Protection degree Smaller Bigger
Number of connections Bigger Smaller
Maximum operation per hour 15 operations/hour 15 operations/hour
Operation mode Remote Manual
3 Functions in a Single Product!
Switching
Overload protection
Short-circuit protection
I >
Electrical DiagramElectrical Diagram
Short-circuit protection
Switching
Overload protection
Note: 1) Fuse installed on fuse holders IP00.
www.eecontrols.ca
4 Motor Circuit Protectors - MN Series
Motor Protective Circuit Breakers MN Series - Overview
EEC's new generation of Manual Motor Protectors provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter: Motor Disconnect, Branch Circuit Protection, Motor Controller and Motor Overload Protection. EEC's MN series meets all of these requirements, and the UL/CSA requirements for Self-Protected Motor Controllers to be used in Type-E & F applications. With worldwide approvals the EEC's MN serie s can be used in a variety of applications all over the world.
Combination starters are the most common type of packaged motor controllers. They are called combination because of their construction and combined functions required by the US National Electric Code (NEC) and Canadian Electrical Code (CSA) Motor Disconnect, Motor Branch Circuit Protection, Motor Controller and Motor Overload Protection. UL & CSA (hamonized) currently recognizes six different types of combination starters that meet the requirements of a motor branch circuit.
Constructions Types A through D are traditionalstarters that use either a listed disconnect switch andfuses or a listed circuit breakers as the disconnectmeans and for short circuit protection. Each type usesa separate UL 508 & CSA 22.2 #14 listed motor controller and overload relay. Recently revisions on UL508 & CSA 22.2 #14 introduced the Type "E" and Type "F" starters.
Type "E" starter is a self-protected combination motor controller that combines in a single device all the required functions of a combination starter and eliminates any additional requirements for upstream fuses or circuit breakers. These starters clear faults within their rating without sustaining damage to themselves or the rest of the system, being able to get back into operation. There are two arrangements for aType E starter: manual (as stand-alone) and associatedwith a contactor. Both are submitted to the same testssequences.
Type "F" starter consists of a listed manual Type "E" combined with a UL508 & CSA 22.2 #14 listed contactor. The differencebetween the two types is related to the absence of self-protected characteristic; hence, Type "F" has softened tests sequences allowing damages on the contactor after a fault.
Tests performed in order to fulfill the Type "E" requirements are considered the hardest in UL & CSA, including short-circuit and endurance tests on the same sample. As a comparison, UL Type "E" exceeds the requirements for Type "F" and IEC60947-4-1 Coordination type 2.
EEC's self-protected combination Type "E" combinesall of these functions within a single product for a manual operation or within a set of two products (with a listed contactor) for a remote operation. They are preferred for a wide range of applications where traditional full voltage combination starters have been required. Some examples are: Pumps, Industrial Washing Machines, Compressors, Blowers, Cutting Machines, Conveyors, Lumber Processing and many others.
The Manual Type "E" Starter is a stand-alone product that ranges from fractional up to 60Hp @ 575V motors (0.16 to 65A) with up to 65KA @ 480V and 25KA @ 600V interrupting shortcircuit capability (MN65). Together with a complete line of accessories, the MN series are a compact and reliable solution for starting and protecting motors.
In addition to its popular line of UL/CSA enclosed starters,EEC is now introducing a new line of combination starters, with optional ratings from NEMA 1, 4, 4X, 12 & 13. EEC's enclosed Type "E" & "F" Starter featuring as standard a handle for disconnect means - MN Series are "Suitable as a Motor Disconnect" - through the door and a contactor for remote operation. Provisions for control circuit transformer, operators, pilot lights and a variety of accessories are available to meet each applications requirements.
www.eecontrols.ca
5Motor Circuit Protectors - MN Series
Introducing our latest in technology and design, EEC's MN Series Motor Circuit Protectors save panel space and can be used in most applications in motor control.It combines short-circuit and motor overload protections in just one component. These devices include a three-position rotary ON-TRIP-OFF handle, which can be padlocked in the OFF position.
MN32 up to 32 A MN65 up to 65 A
Gene
ral t
echn
ical
dat
a
Maximum rated current Imax(Iu) 32 A 65 A
Number of poles 3 3
Short-circuit release 13 x lu max 13 x lu max 13 x lu max 13 x lu max
Rated operational voltage Ue 600 V 600 V 600V 600 V
Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Utilization categoryIEC 60 947-2 (circuit breaker) A A A A
IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 AC-3
UL/CSA Approved Yes Yes Yes Yes
UL 508 Type "F" Certified Yes No Yes No
UL 508 Type "E" Certified Yes No Yes No
Tripping test Yes Yes Yes Yes
Overload protection Yes No Yes No
Phase failure sensitivity Yes No Yes No
Tripping indication Yes Yes Yes Yes
Tripping Class 10 - 10 -
Mechanical life Number of operations 100,000 100,000 50,000 50,000
Electrical life Number of operations 100,000 100,000 25,000 25,000
Temperature compensation -20...+60 °C - -20...+60 °C -
Type of protection ThermomagneticMagnetic*
ThermomagneticMagnetic*
* - Special Order Only * - Special Order Only
Setting overload release
Ir(A)
Reference code
Terminal type Screw
0.1...0.16 MN32H001 MC32H001 - -0.16...0.25 MN32H002 MC32H002 - -0.25...0.4 MN32H004 MC32H004 - -0.4...0.63 MN32H006 MC32H006 - -0.63...1 MN32H010 MC32H010 - -1...1.6 MN32H016 MC32H016 - -
1.6...2.5 MN32H025 MC32H025 - -2.5...4 MN32H040 MC32H040 - -4...6.3 MN32H063 MC32H063 - -6.3...10 MN32H100 MC32H100 - -10...16 MN32H160 MC32H160 - -16...20 MN32H200 MC32H200 - -20...25 MN32H250 MC32H250 - -25...32 MN32H320 MC32H320 - -32...40 - - MN65H400 MC65H40040...50 - - MN65H500 MC65H50050...65 - - MN65H650 MC65H650
Motor Protective Circuit Breakers MN Series - Overview
www.eecontrols.ca
6 Motor Circuit Protectors - MN Series
Motor Protective Circuit Breaker MN32 - Overview
1 - Motor protective circuit breaker 2 - Feeder terminal3 - Three-phase busbars4 - Push-in-lugs5 - Side auxiliary contact block 6 - Undervoltage release URMP or shunt release7 - Front auxiliary contact block8 - Door coupling rotary handle RMMP9 - Connector - For LSN4, LSN5, LSN7, LSN1110 - Contactors - LSN4, LSN5, LSN7, LSN1111 - Door coupling rotary handle
12 - Front plate13 - Standard insulated enclosure14 - Large insulated enclosure15 - Trip signalling block16 - Connector - For LSN15, LSN1817 - Contactors - LSN15, LSN1818 - Connector - For BA09, BA16, BA2519 - Mini-contactor - BA09, BA16, BA220 - Feeder terminal for “Type E” motor starter according to UL21 - Current limiter Unit (Special Order)
1212
11
11
1818
1616
19191010 1717
99
11
77
88
1515
55
1166
3344
44
2020
2121
1414
1111
11
1313
22
www.eecontrols.ca
7Motor Circuit Protectors - MN Series
Motor Protective Circuit Breaker MN32 - Selection Table
J • Suitable for manual motor controller, group installation, Tap conductor and combination starters - Type "E" & Type "F"
J • Built-in protection: disconnect means, short-circuit protection, motor control and overload protection
J • Short-circuit interrupting capacity up to 50kA @ 480Vac & 25kA @ 600Vac J • Fixed short-circuit release 13 x Iu J • Phase loss sensitivity J • Ambient temperature compensation -20…+60ºC ( -4…+140ºF)
Single-phase motor 50/60 Hz Three-phase motor 50/60 Hz Rated current
Iu(A)
Setting overload release
Ir(A)
Instantaneous magnetic trip
Irm(A)
Reference code
Weight
Lbs
120 V
hp
230 V
hp
208 V
hp
230 V
hp
480 V
hp
600 V
hp
- - - - - - 0.16 0.1...0.16 2.0 MN32H001
0.8
- - - - - - 0.25 0.16...0.25 3.2 MN32H002
- - - - - - 0.4 0.25...0.4 5.2 MN32H004
- - - - - 1/4 0.63 0.4...0.63 8.1 MN32H006
- - - - 1/2 1/2 1 0.63...1 13 MN32H010
- 1/10 1/4 1/3 3/4 1 1.6 1...1.6 20.8 MN32H016
- 1/6 1/2 1/2 1.5 1.5 2.5 1.6...2.5 32.5 MN32H025
1/8 1/3 3/4 1 2 3 4 2.5...4 52 MN32H040
1/4 3/4 1.5 1.5 3 5 6.3 4...6.3 81.9 MN32H063
1/2 1.5 3 3 5 7.5 10 6.3...10 130 MN32H100
1 3 5 5 10 15 16 10...16 208 MN32H160
1.5 3 5 7.5 15 15 20 16...20 260 MN32H200
2 3 7.5 7.5 15 20 25 20...25 325 MN32H250
- 5 10 10 20 25 32 25...32 416 MN32H320
Motor Protective Circuit Breaker MN32H - Thermomagnetic
Motor Protective Circuit Breaker MC32H - Magnetic
Single-phase motor 50/60 Hz Three-phase motor 50/60 Hz Rated current
Iu(A)
Instantaneous magnetic trip
Irm(A)
Reference code
Weight
Lbs
120 V
hp
230 V
hp
208 V
hp
230 V
hp
480 V
hp
600 V
hp
- - - - - - 0.16 2.0 MC32H001
0.8
- - - - - - 0.25 3.2 MC32H002
- - - - - - 0.4 5.2 MC32H004
- - - - - 1/4 0.63 8.1 MC32H006
- - - - 1/2 1/2 1 13 MC32H010
- 1/10 1/4 1/3 3/4 1 1.6 20.8 MC32H016
- 1/6 1/2 1/2 1.5 1.5 2.5 32.5 MC32H025
1/8 1/3 3/4 1 2 3 4 52 MC32H040
1/4 3/4 1.5 1.5 3 5 6.3 81.9 MC32H063
1/2 1.5 3 3 5 7.5 10 130 MC32H100
1 3 5 5 10 15 16 208 MC32H160
1.5 3 5 7.5 15 15 20 260 MC32H200
2 3 7.5 7.5 15 20 25 325 MC32H250
- 5 10 10 20 25 32 416 MC32H320
Note: 1) Some motors characteristics may vary according to each manufacturer.
www.eecontrols.ca
8 Motor Circuit Protectors - MN Series
Motor Protective Circuit Breaker MN65 - Overview
1
5
6
2
2
3
4
7
8
9
10
1 - Motor protective circuit breaker2 - Push-in-lugs3 - Side auxiliary contact block4 - Undervoltage release or shunt release5 - Frontal auxiliary contact block
6 - Trip signalling block7 - Door coupling rotary handle - NEMA 3R/128 - Door coupling rotary handle - NEMA 4/4X9 - Scale cover10 - Feeder terminal for “Type E” motor starter according to UL/CSA
Motor Protective Circuit Breaker MN65 - Selection Table J • Suitable for manual motor controller, group installation, Tap conductor and
combination starters - Type "E" & Type "F" J • Built-in protection: disconnect means, short-circuit protection, motor control
and overload protection J • Short-circuit interrupting capacity up to 35kA @ 480Vac & 10kA @ 600Vac J • Fixed short-circuit release 13 x Iu J • Phase loss sensitivity J • Ambient temperature compensation -20…+60ºC ( -4…+140ºF)
Single-phase motor 50/60 Hz Three-phase motor 50/60 Hz Rated current
Iu(A)
Setting overload release
Ir(A)
Instantaneous magnetic trip
Irm(A)
Reference code
Weight
Lbs
120 V
hp
230 V
hp
208 V
hp
230 V
hp
480 V
hp
600 V
hp
3 7.5 - 15 25 30 40 32...40 520 MN65H400
2.36- 10 15 15 30 40 50 40...50 650 MN65H500
5 10 20 20 50 60 65 50...65 845 MN65H650
Motor Protective Circuit Breaker MN65H - Thermomagnetic
Motor Protective Circuit Breaker MC65H - Magnetic
Single-phase motor 50/60 Hz Three-phase motor 50/60 Hz Rated current
Iu(A)
Instantaneous magnetic trip
Irm(A)Reference code
Weight
Lbs
120 V
hp
230 V
hp
208 V
hp
230 V
hp
480 V
hp
600 V
hp
3 7.5 - 15 25 30 40 520 MC65H400
2.36- 10 15 15 30 40 50 650 MC65H500
5 10 20 20 50 60 65 845 MC65H650
www.eecontrols.ca
9Motor Circuit Protectors - MN Series
For use with Illustrative pictureAuxiliary contacts
Reference codeWeight
LbsNO NC
MN32 / MC32MN65 / MC65
1 1 MNA11S
0.012 - MNA20S
- 2 MNA02S
For use with Illustrative pictureAuxiliary contacts
Reference codeWeight
LbsNO NC
MN32 / MC32MN65 / MC65
1 1 MNA11T 0.06
Front Auxiliary Contact Block - MNA11T
Left Side Auxiliary Contact Block
Motor Protective Circuit Breakers - Accessories
For use with Illustrative picture Description Reference codeWeight
Lbs
MN32 / MC32MN65 / MC65
- Equipped with 2 auxiliary contacts (1NO + 1NC) for overload trip signalling and 2 other auxiliary contacts (1NO + 1NC) for short-circuit trip signalling.
- To reset the circuit breaker after a short-circuit, the flag must be manually reset after the cause of the failure has been solved.
- Lateral auxiliary contacts can be assembled together with the trip signalling block.
- Left side assembly only.
MNTSB 0.29
Trip Signalling Block
Undervoltage Release
For use with Illustrative picture Voltage1) Reference codeWeight
Lbs
MN32 / MC32MN65 / MC65
Note: - Operating voltage > 0.85 x Ue
- Non operating voltage 0.35...0.7 x Ue
24 V 50/60 Hz110 V 50 Hz / 120 V 60 Hz
208 V 50 Hz / 200-240 V 60 Hz230-240 V 50 Hz / 277 V 60 Hz
325 V 50 Hz / 380 V 60 Hz400-415 V 50 Hz / 480 V 60 Hz
500 V 50 Hz / 600 V 60 Hz
MNAUVTGMNAUVTAMNAUVTCMNAUVTHMNAUVTDMNAUVTEMNAUVTF
0.29
Notes: 1) Other voltages avaliable upon request
www.eecontrols.ca
10 Motor Circuit Protectors - MN Series
Motor Protective Circuit Breakers - Accessories
Notes: 1) Other voltages avaliable upon request
For use with Illustrative picture Voltage1) Reference codeWeight
Lbs
MN32 / MC32MN65 / MC65
Note: - Operating voltage > 0.7 x Ue
20-24 V 50/60 Hz100-127 V 50/60 Hz200-240 V 50/60 Hz365-440 V 50/60 Hz
MNASHTGMNASHTAMNASHTCMNASHTE
0.29
Shunt Release
Block Modules for Motor Protective Circuit Breaker Assembly + Contactors
For use with Illustrative picture Description ContactorsReference
codeWeight
Lbs
MN32 / MC32
- For direct connection (electrical and mechanical) of motor circuit breakers to contactors.
Note: - Not applicable to LSN contactors with DC coils, but suitable for use with BA contactors with DC coils
BA09...BA16 MNADBA1
0.06
BA25 MNADBA2
LSN4...LSN11LSN15,LSN18
MNADLS1MNADLS2
Door Coupling Rotary Handle
For use with Illustrative picture DescriptionHandle color
Reference codeWeight
Lbs
MN32 / MC32
- Degree of protection IP55; - Shows circuit breaker position “I”(ON) or “O”(OFF);- Panel door can only be opened in OFF position;- Adjustable shaft length. There are shaft size: 330-355 mm. - To assembled the handle on the circuit breaker the shaft must have a length of at least 80 mm;- Up to 3 padlocks can be used in the OFF position. This blocks
circuit breaker operation and opens panel door;- Handle can be mounted on panels with a thickness of 1 to 5 mm;- Handle can be assembled even with circuit breaker turned in
90º position.
Black / Grey
MNAHS1N1
0.56
Red/Yellow
MNAHR1N1
MN65 / MC65
Black / Grey
MNAHS2N1
Red/Yellow
MNAHR2N1
MN32 / MC32- Panel door can be opened in ON position (thermometry);- Degree of protection: IP65/Nema 4X;- Shows circuit breaker position “I”(ON) or “O”(OFF);- Adjustable shaft length. There are shaft size: 330-355 mm. - To assembled the handle on the circuit breaker the shaft must have a length of at least 80 mm;- Up to 3 padlocks can be used in the OFF position. This blocks
circuit breaker operation and opens panel door;- Handle can be mounted on panels with a thickness of 1 to 5 mm
Black / Grey
MNAHS1N4X
Red/Yellow
MNAHR1N4X
MN65 / MC65
Black / Grey
MNAHS2N4X
Red/Yellow
MNAHR2N4X
www.eecontrols.ca
11Motor Circuit Protectors - MN Series
Front Plate
For use with Illustrative picture DescriptionHandle color
Reference codeWeight
Lbs
MN32 / MC32
- For motor protective circuit breaker assembly in panel door or side
- Degree of protection: IP55 - MN32 fits directly into base - Rotary handle in enclosure- Handle can be locked with up to 3 padlocks at OFF position - Signalling lamps can be installed on enclosure
Black / Grey
MNE55FB 0.44
Red / Yellow MNE55FY 0.44
For use with Illustrative picture Description Terminals Handle color Reference codeWeight
Lbs
MN32 / MC32
- Empty plastic enclosure- Degree of protection IP55- 2 inputs/outputs for cable gland ØPG16 on top/bottom, and 2 inputs/outputs ØM20 in the back- Rotary handle on the cover- Handle can be locked with up to 3 padlocks in the “OFF” position- Color: cover (gray RAL 7035) and base (black RAL 7021).
With neutral and ground terminals
Black / grey MNE55HB 0.93
Red / Yellow MNE55HR 0.93
Standard Insulated Enclosure - Surface Mount
Motor Protective Circuit Breakers - Accessories
For use with Illustrative picture Lamp color Voltage Reference codeWeight
Lbs
All models
Red
24 V 50/60 Hz / V dc MNILRG
0.012
110...130 V 50/60 Hz MNILRA
210...230 V 50/60 Hz MNILRC
400...575 V 50/60 Hz MNILRF
Green
24 V 50/60 Hz / V dc MNILGG
110...130 V 50/60 Hz MNILGA
210...230 V 50/60 Hz MNILGC
400...575 V 50/60 Hz MNILGF
White
24 V 50/60 Hz / V dc MNILWG
110...130 V 50/60 Hz MNILWA
210...230 V 50/60 Hz MNILWC
400...560 V 50/60 H75 MNILWF
Pilot Lights
www.eecontrols.ca
12 Motor Circuit Protectors - MN Series
For use with Illustrative picture Description Contactors Reference codeWeight
Lbs
MN32 / MC32
Used for direct on line starters
45 mm width
BA09...BA25LSN4…LSN11
MNAPKD 0.06
MN32 / MC32
Used for reversing starters
90 mm width
2 x BA09...BA252 x LSN4…LSN11
MNAPKR 0.06
MN32 / MC32
Used for wye-delta motor starters
90 mm width
2 x BA09...BA252 x LSN4…LSN11
MNAPKW 0.06
Motor Protective Circuit Breaker Mounting Adapter + Contactor
Motor Protective Circuit Breakers - Accessories
For use with Illustrative picture Description Reference codeWeight
Lbs
MN32 / MC32
- Block module for “ Type E“ Combination motor Controller” only required in use with MN32B - Bus Links
- Rated insulation voltage: 690 V ac; - Ie: 63 A.- Terminals: 8-20 AWG.
MNAEAD1 0.1
MN65 / MC65
- Block module for “ Type E“ Combination motor Controller” only required in use with bus links or wire jumpers
- Rated insulation voltage: 690 V ac;- Ie: 63 A;- Terminals: 4-8 AWG.
MNAEAD2 0.4
Three-Phase Feeder Terminal
For use with Illustrative picture Description Reference codeWeight
Lbs
MN32MC32
For protecting electrical circuits where extra high shortcircuitbreaking capacity is required: - 100kA @ 480VAC & 50KA @ 600V
Note: This accessory must be used together with a MNmotor protector.
MNACLT 0.69
Current Limiter
www.eecontrols.ca
13Motor Circuit Protectors - MN Series
Three-Phase Busbars for Circuit Breakers Without Side Fitted Auxiliary Contacts
For use with Illustrative picture DescriptionNumbers of circuit
protectorReference code
Weight Lbs
MN32 / MC32
- For parallel blocking of side-by-side mounted circuit breakers. without side auxiliary contacts -
- Enables the use of frontal auxiliary contact block
- Ue: 600 V ac- Ie: 63 A
2 MN32BN02 0.01
3 MN32BN03 0.16
4 MN32BN04 0.23
5 MN32BN05 0.27
Three-Phase Busbars for Motor Protection Circuit Breakers with Side Fitted Auxiliary Contacts
For use with Illustrative picture DescriptionNumbers of circuit
protectorReference code
Weight Lbs
MN32 / MC32
- For parallel blocking of side-by-side mounted circuit breakers
- Enables the use of side auxiliary contact block mounted on each motor protective circuit breaker
- Ue: 600 V ac - Ie: 63 A.
2 MN32BD02 0.01
3 MN32BD03 0.16
4 MN32BD04 0.23
5 MN32BD05 0.27
Motor Protective Circuit Breakers - Accessories
Scale Cover / Terminal Adjustable Dial
Panel Screw Mounting Adaptor Kits - Direct Mount vs. Din-rail Mount (Din-rail Integrated with MN Series)
For use with Illustrative picture Description Reference codeWeight
Lbs
MN32 / MC32MN65 / MC65
Protects the current adjustment dial against direct contact while enabling the adjusted current to be viewed.
MNADCP 0.01
For use with Illustrative picture Description Reference codeWeight
Lbs
MN32 / MC32MN65 / MC65
For direct assembly of motor protective circuit breaker onto any surface using screws.
MNASPAK 0.01
www.eecontrols.ca
14 Motor Circuit Protectors - MN Series
The MN32 and MN65 motor protective circuit breakers can also be used for operating continuous current loads. For such operation it is necessary to connect 2 or 3 poles in series.See recommended circuits and their voltage limits in the table on the right.
Time constant t = 5ms
Short-circuit breaking capacity Icu = 10 kA for all configurations.
Circuits Max. V dc Notes
150 V dcSystem notgrounded
2 pole series connected
300 V dcSystem
grounded2 pole series connected
450 V dcSystem
grounded 3 pole series connected
DC Operation
Reference code MN32 MC32 MN65 MC65
Maximum rated current Imax(Iu) 32 A 32 A 65 A 65 A
Number of poles 3 3 3 3
Instantaneous short-circuit 13 x Iemax. 13 x Iemax. 13 x Iemax. 13 x Iemax.
Rated operational voltage Ue 690 V1) 690 V1) 690 V 690 V
Rated operational frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Insulation voltage Ui 690 V 690 V 690 V 690 V
Rated impulse withstand voltage Uimp 6 kV 6 kV 6 kV 6 kV
UL/CSA Approved Yes Yes Yes Yes
UL 508 Type "F" Certified Yes No Yes No
UL 508 Type "E" Certified Yes No Yes No
Tripping test Yes Yes Yes Yes
Overload protection Yes No Yes No
Phase failure sensitivity Yes No Yes No
Tripping indication Yes Yes Yes Yes
Tripping class 10 - 10 -
Maximum operating frequency
Operations/hour 15 15 15 15
Altitude (m) 2,000 2,000 2,000 2,000
Degree of protection IP20 IP20 IP20 IP20
Mechanical life span Number of operations 100,000 100,000 50,000 50,000
Electrical life span Number of operations 100,000 100,000 25,000 25,000
Ambient temperatures allowed
Transport and storage -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C
Operation1) -20...+70 °C -20...+70 °C -20...+70 °C -20...+70 °C
Temperature compensation -20...+60 °C - -20...+60 °C -
Resistance to impact (g) 15 15 15 15
Standards
IEC/EN 60 947-1, DIN VDE 0660 (part 100) Yes Yes Yes Yes
IEC/EN 60 947-2, DIN VDE 0660 (part 101) Yes Yes Yes Yes
IEC/EN 60 947-4-1, DIN VDE 0660 (part 102) Yes Yes Yes Yes
Terminal capacity
Type of terminal Flat Flat Box Box
Tightening torqueN.m 2...2.5 2...2.5 4...6 4...6
lb.in 18...22 18...22 35...55 35...55
Type of screws Philips (Nº2) Philips (Nº2) Allen (4 mm) Allen (4 mm)
Dimensions
Width (mm) 45 45 54 54
Height (mm) 97 97 125 125
Note: 1) Reduce current for temperatures exceeding +60 °C (87% to 70 °C).
Motor Protective Circuit Breakers - Technical Data
www.eecontrols.ca
15Motor Circuit Protectors - MN Series
Main Terminal Capacity
Note: 1) 8 AWG for flexible cable only.
Reference code Type Number of conductors Cross-section
MN32 / MC32 Rigid or flexible cable 1 or 21...2.5 mm2
2.5...6 mm2
14...8 AWG1)
MN65 / MC65
Type 1 conductor connection on top only Cross-section
Rigid cable 1...35 mm2
Cable without terminal 1.5...35 mm2
Cable with terminal 1...35 mm2
Flexible cable1.5...35 mm2
17...2 AWG
Type 1 conductor connection on top only Cross-section
Rigid cable 2.5...35 mm2
Cable without terminal 6...35 mm2
Cable with terminal 2.5...35 mm2
Flexible cable6...35 mm2
13...2 AWG
Type 1 conductor connection on top only Cross-section
Rigid cable
Conductor on top (A)
1...35 mm2
Cable without terminal 1.5...35 mm2
Cable with terminal 1...35 mm2
Flexible cable1.5...35 mm2
17...2 AWG
Type Cross-section
Rigid cable
Conductor on bottom (B)
2.5...35 mm2
Cable without terminal 6...35 mm2
Cable with terminal 2.5...35 mm2
Flexible cable6...35 mm2
13...2 AWG
Mounting Configurations for MN Motor Protective Circuit BreakerLive or grounded parts distance to the circuit breaker
Description Ue
Minimum distance between the circuit breaker and live or grounded parts (mm)
A B C
MN32 / MC32 Up to 600 V 9 30 95
MN65 / MC65 Up to 600 V 10 50 150
*- According to IEC 60447 & UL/CSA standards, the “On - I” indicator must be to the right, or up.
B
A
www.eecontrols.ca
16 Motor Circuit Protectors - MN Series
Auxiliary Contact BlockReference code MNA11T MNA11S, MNA20S, MNA02S
For use with MN32, MC32, MN65, MC65
Utilization category 24 V ac 220-230 V ac 24 V ac 230 V ac 400 V ac 690 V ac
UL/CSA 2.5A 2.5A 6 A 6 A 3 A 1 A
AC-15 2.5 A 2.5 A 10 A 10 A 10 A 10 A
DC-1324 V dc 48 V dc 60 V dc 24 V dc 110 V dc 220 V dc 440 V dc
1 A 0.3 A 0.15 A 2 A 0.5 A 0.25 A 0.1 A
Type of terminal Flat
Type of screw Philips (Nº2)
Tightening torque 0.8…1.2 N.m (7…10 lb.in)
Rigid cable1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2). 2 x (18…14 AWG)
Flexible cable
Backup MCB (UL1077) 6A IEC / 5A UL/CSA
Backup fuses 10 A
Undervoltage and Shunt ReleaseReference code MNAUVT* MNASHT*
For use with MN32, MC32, MN65, MC65
Operating voltage (enables cir. breaker switch on)
0.85...1.1xUs 0.7...1.1xUs
Non-operating voltage (guarantees circuit breaker switch OFF)
0.7...0.35xUs N/A
Energization consumption 20.2 VA / 13 W 8.5 VA / 6 W
Consumption 7.2 VA / 2.4 W N/A
Max. opening time 20ms
Type of terminal Flat
Type of screws Philips (Nº2)
Tightening torque 0.8…1.2 N.m (7…10 lb.in)
Rigid cable 1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2) 2 x (18…14 AWG)
1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2) 2 x (18…14 AWG)Flexible cable
Backup MCB (UL1077) 6A IEC / 5A UL/CSA
Back-up fuses 10 A
www.eecontrols.ca
17Motor Circuit Protectors - MN Series
Single-phase motor 50/60 Hz Three-phase motor 50/60 Hz Setting overload release
Ir(A)
Short-Circuit
InterruptionCapacity
Short-Circuit
InterruptionCapacity
Reference code
Weight
Lbs
120 V
hp
230 V
hp
208 V
hp
230 V
hp
480 V
hp
600 V
hp
- - - - - - 0.1...0.16
50kA 25kA
MN32CH001-N4*
0.8
- - - - - - 0.16...0.25 MN32CH002-N4*
- - - - - - 0.25...0.4 MN32CH004-N4*
- - - - - 1/4 0.4...0.63 MN32CH006-N4*
- - - - 1/2 1/2 0.63...1 MN32CH010-N4*
- 1/10 1/4 1/3 3/4 1 1...1.6 MN32CH016-N4*
- 1/6 1/2 1/2 1.5 1.5 1.6...2.5 MN32CH025-N4*
1/8 1/3 3/4 1 2 3 2.5...4 MN32CH040-N4*
1/4 3/4 1.5 1.5 3 5 4...6.3 MN32CH063-N4*
1/2 1.5 3 3 5 7.5 6.3...10 MN32CH100-N5*
1 3 5 5 10 15 10...16 MN32CH160-N7*
1.5 3 5 7.5 15 15 16...20 MN32CH200-N11*
2 3 7.5 7.5 15 20 20...25 MN32CH250-N15*
- 5 10 10 20 25 25...32 MN32CH320-N15*
3 7.5 10 15 25 30 30...40
35kA 10kA
MN65CH400-N22*
- 10 15 15 30 40 40...50 MN65CH500-N30*
5 10 20 20 50 60 50...65 MN65CH650-N37*
J * - Replace with Coil Suffix: J A = 110-120VAC - 50/60Hz J C = 208-240VAC - 50/60Hz J D = 380VAC - 60Hz J E = 480VAC - 50/60Hz J F = 600VAC - 50/60Hz J G = 24VAC - 50/60Hz J H = 277VAC - 60Hz
Type “E” Coordination - LSN Series
Manual Self-Protected Combination Motor Controller - Type "E"
• No need of upstream protective devices such as UL489 MCCB or UL248 fuses• Built-in protections: disconnect means, short-circuit protection, motor control and overload protection• Short-circuit interrupting capacity up to 100kA@480Vac (50kA@600Vac)• Compact combination starter• Phase loss sensitivity• Ambient temperature compensation -4…+140ºF (-20…+60ºC)
Ordering example: the type can be found in the “Rated operational power” column alongside the selected rating 5.0hp @ 575V with a 120VAC desired type: MN32CH063-N4A = MN32H063 + MNADLS1 + LSN4-310-A (120VAC Coil - 50/60Hz).
www.eecontrols.ca
18 Motor Circuit Protectors - MN Series
Motor Protective Circuit Breakers - Rated Short-Circuit Breaking Capacity
MN32, MC32, MN65, MC65
Setting overload release
(A)
MN32/MC32 without MNACLT MN32/MC32 with MNACLT MN65/MC65
480V 600V 480V 600V 480V 600V
kA kA kA kA kA kA
0.10...0.16 65 25 100 50 - -
0.16...0.25 65 25 100 50 - -
0.25...0.4 65 25 100 50 - -
0.4...0.63 65 25 100 50 - -
0.63...1 65 25 100 50 - -
1...1.6 65 25 100 50 - -
1.6...2.5 65 25 100 50 - -
2.5...4 65 25 100 50 - -
4...6.3 65 25 100 50 - -
6.3...10 65 25 100 50 - -
8...12 65 25 100 50 - -
10...16 3) 65 25 100 50 - -
0.10...0.16 65 25 100 50 - -
0.16...0.25 65 25 100 50 - -
0.25...0.4 65 25 100 50 - -
0.4...0.63 65 25 100 50 - -
0.63...1 65 25 100 50 - -
1...1.6 65 25 100 50 - -
1.6...2.5 65 25 100 50 - -
2.5...4 65 25 100 50 - -
4...6.3 65 25 100 50 - -
6.3...10 65 25 100 50 - -
10...16 65 25 100 50 - -
16...20 50 25 100 50 - -
20...25 50 25 100 50 - -
25...32 50 25 100 50 - -
30...40 - - - - 35 10
40...50 - - - - 35 10
50...65 - - - - 35 10
www.eecontrols.ca
19Motor Circuit Protectors - MN Series
Motor Protective Circuit Breakers - Characteristics Curves
The tripping characteristic shows the motor circuit breaker trip time in relation to the rated current.The curves show average tolerance range values for an ambient temperature of 20 °C, starting in cold state. Thermal trip time when working in operating temperature is reduced to around 25% of the presented values. Under normal operating conditions, all 3 circuit breaker phases must be conducting.
Characteristic I2t at 460 V - MN32 / MC32
Presumed short-circuit current (kA) [RMS]
Characteristic I2t at 460 V - MN65 / MC65
1
10
100
1000
0,1 1 10 100
I².t x
10³
(A².s
)
Prospektiver kurzchlusstrom (kA) [RMS]
Durchlasswerte I2t at 415V - MPW65/65i
65
50
40
Presumed short-circuit current (kA) [RMS]
I2.t
x 1
03 (A
2.s
)
www.eecontrols.ca
20 Motor Circuit Protectors - MN Series
MN32 / MC32 + BA09…BA16
MN32 / MC32 + AccessoriesMounting Position
MC32MN32
165
MNADBA1
BA09...BA16
98
45
MNTSBMNAUVTMNASHT
MNA**S
ON
L
OFF
D
DIN35mm
90
45 1818
MNA11S
MNASHTMNAUVT
Ø4.
8
118
105
98 30
97MNTSB
9
www.eecontrols.ca
21Motor Circuit Protectors - MN Series
MN32 / MC32 + LSN4...LSN7
MN32 / MC32 + LSN11
MN32 / MC32 + BA25
ON
L
OFF
D
176
165
MNADBA2
BA25
MC32MN32
9845
MNADLS1
LSN4LSN5LSN7
9845 98 4.80
MNASPAK
4.50
35
1018
3
18319
3
4.80
4.50
35
10
MNASPAK
30
9845
MNADLS1
LSN11
183
183
193
MC32MN32
Din rail-35 mm(DIN EM50022)
MC32MN32
www.eecontrols.ca
22 Motor Circuit Protectors - MN Series
MN32 / MC32 + LSN15
Front Plate - MNE55F
Insulated Enclosure - MNE55H (IP55)
Current Limiter - MNACLT
167
M25M25
92129
157
109
155
Ø4.
5
Maximum trickness ≤ 5
105
85 89
A<5
55
DIN35mm
7230
MN32MC32
MNADLS2
200
LSN15
98
45
118
105
Ø4.8
55
105
www.eecontrols.ca
23Motor Circuit Protectors - MN Series
Accessories:
Door Coupling Rotary Handle - MNAHS1N1
MN65 + MNAEAD2
Ref. code MN32BN02 MN32BN03 MN32BN04 MN32BN05
A 85 130 175 220
Ref. code MN32BD02 MN32BD03 MN32BD04 MN32BD05
B 94 149 202 256
143
133
118
LST25
98
to
A
B 133.
512
7.5
118
123
143
133
118
MN32BNMN32BD
MN32MC32
MN32MC32
MNAEAD1
MNAEAD2
MN65MC65
33.6
63
54 32
44
156.63
72
9 18
12.2
118
97
5.5
6.9 45119.4
Panel door drillings97
149 302
Door panel thichness1.0 to 5.0 mm
Shaft (330 mm)
105
30
169177
4098
98
25
51
54
44 24
28
28
2540
13
20
14.4
45
Ø4.8
Ø4R20
Ø16
45°
www.eecontrols.ca
24 Motor Circuit Protectors - MN Series
Door Coupling Rotary Handle - MNAHS1N4X
Door Coupling Rotary Handle - MNAHS2N1
Door Coupling Rotary Handle - MNAHS2N4X
MN65 / MC65 + Accessories Mounting Position
≤
DIN35mm
Drilling the panel door
11.5
0
7.20
430
Shaft (330 mm)
154 276
50.70
97A
99
157
213 302
51519.22
Shaft (330 mm)
Panel door drillings
Ø16Ø4R2
0
45°
52,60
A < 5.0 mm
3.50
125
54
10
≤
Shaft (330 mm)
50.70
MRX
54
A
B
213
489
27648.50
24.25
48.5
0
24.2
5
Ø22.50
Ø4
23.5
0
3.20
A < 5.0 mm
MPW65MPW65i
33
125
10
30
Ø4.80
144
125
ACBS URMPSRMP
TSB
5418 18
9
MNA11SMNASHTMNAUVT
MNTSB
Panel door drillings
3.50
48.50
24.2
5
48.5
0
24.25
Ø22.50Ø4
23.5
0
3.20
www.eecontrols.ca
25Motor Circuit Protectors - MN Series
Notes
www.eecontrols.ca
The values shown are subject to change without prior notice. The information contained is reference values.
ED: 01 | Rev: 01 | Date: 08/2020.
LOW VOLTAGE CONTROL
Orangeville - ON - Canada
(519) 941-6845
For more EEC products visit our website