GETTING STARTED GUIDE NI USB-7856R R Series for USB Multifunction RIO with Kintex-7 160T FPGA Français Deutsch 日本語 한국어 简体中文 ni.com/manuals This document explains how to install and configure National Instruments USB-7856R. Safety Guidelines Caution Do not operate the NI USB-7856R in a manner not specified in this user manual. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instruments for repair. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) as stated in the product specifications. These requirements and limits are designed to provide reasonable protection against harmful interference when the product is operated in its intended operational electromagnetic environment. This product is intended for use in residential, commercial, and industrial locations. However, harmful interference may occur in some installations or when the product is connected to a peripheral device or a test object. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, you must install the included snap-on ferrite bead onto the DC power cord of the power supply as described in this document. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories.

Upload: others

Post on 11-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

GETTING STARTED GUIDE

NI USB-7856RR Series for USB Multifunction RIO with Kintex-7 160T FPGA

Français Deutsch 日本語 한국어 简体中文

ni.com/manuals

This document explains how to install and configure National Instruments USB-7856R.

Safety GuidelinesCaution Do not operate the NI USB-7856R in a manner not specified in this usermanual. Product misuse can result in a hazard. You can compromise the safetyprotection built into the product if the product is damaged in any way. If the productis damaged, return it to National Instruments for repair.

Electromagnetic Compatibility GuidelinesThis product was tested and complies with the regulatory requirements and limits forelectromagnetic compatibility (EMC) as stated in the product specifications. Theserequirements and limits are designed to provide reasonable protection against harmfulinterference when the product is operated in its intended operational electromagneticenvironment.

This product is intended for use in residential, commercial, and industrial locations. However,harmful interference may occur in some installations or when the product is connected to aperipheral device or a test object. To minimize interference with radio and television receptionand prevent unacceptable performance degradation, install and use this product in strictaccordance with the instructions in the product documentation.

Furthermore, any changes or modifications to the product not expressly approved by NationalInstruments could void your authority to operate it under your local regulatory rules.

Caution To ensure the specified EMC performance, you must install the includedsnap-on ferrite bead onto the DC power cord of the power supply as described in thisdocument.

Caution To ensure the specified EMC performance, operate this product only withshielded cables and accessories.

Page 2: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

Unpacking the KitCaution To prevent electrostatic discharge from damaging the device, groundyourself using a grounding strap or by holding a grounded object, such as yourcomputer chassis.

1. Touch the antistatic package to a metal part of the computer chassis.2. Remove the device from the package and inspect the device for loose components or any

other sign of damage.

Caution Never touch the exposed pins of connectors.

Notify NI if the device appears damaged in any way. Do not install a damaged device.3. Unpack any other items and documentation from the kit.

Store the device in the antistatic package when the device is not in use.

Verifying the Kit ContentsVerify the following components are in your kit.

Figure 1. Kit Contents for the NI USB-7856R

3

6

2

5

1

4

1. NI USB-7856R Module2. USB Cable3. Ferrite Bead

4. NI-RIO Media5. Power Supply6. Getting Started Guide

2 | NI USB-7856R Getting Started Guide | ni.com

Page 3: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

Installing SoftwareYou must be an Administrator to install NI software and devices on your computer. Beforeconnecting the hardware, install the software in the following order.1. Install the driver software using either the media included in your kit or by downloading

the latest version from ni.com/downloads.2. Follow the instructions in the installation prompts.

a) Windows 8/7/Vista users may see access and security messages during installation.Accept the prompts to complete the installation.

3. When the installer completes, a dialog box asks if you want to restart, shut down, orrestart later. Select Restart.

Installing the Hardware

Connecting the USB CableUSB modules can be connected directly to the host PC, to a powered USB hub, or to an NIPXI or PXI Express chassis featuring a USB port.1. Connect the USB cable to the NI USB-7856R using the cable device port.2. Connect the other end of the USB cable to the host PC, powered hub, or chassis.3. Use the jackscrew on the locking USB cable to securely attach the cable to the NI

USB-7856R.

Powering the ModuleCaution To ensure the specified EMC performance, install the included snap-onferrite bead onto the DC power cord of the power supply in accordance with theinstructions provided.

1. Install the ferrite bead by opening the housing and looping the power supply once throughthe center of the bead. Ensure the ferrite bead is as close to the end of the cable aspractical.

2. Close the ferrite bead until the locking tabs engage securely.

NI USB-7856R Getting Started Guide | © National Instruments | 3

Page 4: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

Figure 2. Installing the Ferrite Bead

x1

2

1

9-30 V

C V

20 W MAX

1. Power Supply2. Ferrite

3. Connect the power supply to the NI USB-7856R.4. Connect the other end of the power supply to a user-supplied power cord.5. Connect the user-supplied power cord to the appropriate power source.6. Turn the power switch on the NI USB-7856R to the on position.

USB Device Security Cable SlotThe security cable slot allows you to attach an optional laptop lock to your NI USB-7856R.

Note The security cable is designed to act as a deterrent, but might not prevent thedevice from being mishandled or stolen. For more information, refer to thedocumentation that accompanied the security cable.

Note The security cable slot on the USB device might not be compatible with alllaptop lock cables.

Refer to the documentation that accompanied the security cable for installationinstructions.

Verifying Hardware InstallationYou can verify that the system recognizes the USB device by using Measurement &Automation Explorer (MAX).1. Launch MAX by navigating to Start»All Programs»National Instruments»MAX or by

clicking the MAX desktop icon.2. Expand Devices and Interfaces.3. Verify that the device appears under USB Devices.

If the device does not appear, press <F5> to refresh the view in MAX. If the device doesnot appear after refreshing the view, visit ni.com/support for troubleshootinginformation.

4 | NI USB-7856R Getting Started Guide | ni.com

Page 5: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

Connecting SignalsThe following figure shows the I/O connector pin assignments and locations for the NIUSB-7856R.

Caution To ensure the specified EMC performance, operate this product onlywith shielded cables and accessories.

Note NI is not liable for connections that exceed any of the maximum ratingsof input or output signals on the NI USB-7856R and on the computer chassis.For the maximum input and output ratings for each signal, refer to the NIUSB-7856R Specifications, available at ni.com/manuals.

Figure 3. NI USB-7856R Connector Pin Assignments and Locations

DIO30

GND

DIO28

GND

DIO26

GND

DIO24

GND

DIO22

GND

DIO20

GND

DIO18

GND

DIO16

GND

DIO14

GND

DIO12

GND

DIO10

GND

DIO8

GND

DIO6

GND

DIO4

GND

DIO2

GND

DIO0

GND

GND

GND

DIO31

DIO29

GND

GND

DIO25

GND

DIO23

GND

DIO27

GND

DIO21

GND

DIO19

GND

DIO17

GND

DIO15

GND

DIO13

GND

DIO11

GND

DIO9

GND

DIO7

GND

DIO5

GND

DIO3

GND

DIO1

GND

GND

GND68 34

67 33

66 32

65 31

64 30

63 29

62 28

61 27

60 26

59 25

58 24

57 23

56 22

55 21

54 20

53 19

52 18

51 17

50 16

49 15

48 14

47 13

46 12

45 11

44 10

43 9

42 8

41 7

40 6

39 5

38 4

37 3

36 2

35 1 +5V

DIO0

DIO1

DIO2

DIO3

DIO4

DIO5

DIO6

DIO7

DIO9

DIO11

DIO13

DIO15

AO7

AO6

AO5

AO4

AO3

AO2

AO1

AO0

AISENSE

AI7+

AIGND6

AI6+

AI5+

AIGND4

AI4+

AI3+

AIGND2

AI2+

AI1+

AIGND0

AI0+

+5V

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DGND

DIO8

DIO10

DIO12

DIO14

AOGND7

AOGND6

AOGND5

AOGND4

AOGND3

AOGND2

AOGND1

AOGND0

NC

AI7–

AIGND7

AI6–

AI5–

AIGND5

AI4–

AI3–

AIGND3

AI2–

AI1–

AIGND1

AI0–68 34

67 33

66 32

65 31

64 30

63 29

62 28

61 27

60 26

59 25

58 24

57 23

56 22

55 21

54 20

53 19

52 18

51 17

50 16

49 15

48 14

47 13

46 12

45 11

44 10

43 9

42 8

41 7

40 6

39 5

38 4

37 3

36 2

35 1

CONNECTOR 0(DIO)

CONNECTOR 1(MIO)

TERMINAL 34

TERMINAL 68

TERMINAL 1

TERMINAL 35

TERMINAL 34

TERMINAL 68

TERMINAL 1

TERMINAL 35

The +5 V terminals on the I/O connector supply +5 V referenced to GND. Use these terminalsto power external circuitry. The NI USB-7856R is protected from overvoltage and overcurrent

NI USB-7856R Getting Started Guide | © National Instruments | 5

Page 6: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

conditions. Refer to the NI USB-7856R User Manual, available at ni.com/manuals, formore information.

Where to Go NextRefer to the following figure for information about other product tasks and associatedresources for those tasks.

Where to Go for SupportThe National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.

6 | NI USB-7856R Getting Started Guide | ni.com

Page 7: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

National Instruments corporate headquarters is located at 11500 North Mopac Expressway,Austin, Texas, 78759-3504. National Instruments also has offices located around the world tohelp address your support needs. For telephone support in the United States, create yourservice request at ni.com/support and follow the calling instructions or dial 512 795 8248. Fortelephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office Web sites, which provide up-to-date contact information,support phone numbers, email addresses, and current events.

NI USB-7856R Getting Started Guide | © National Instruments | 7

Page 8: NI USB-7856 Getting Started Guide - National Instruments · USB Device Security Cable Slot The security cable slot allows you to attach an optional laptop lock to your NI USB-7856R

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks.Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patentscovering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, thepatents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information aboutend-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the ExportCompliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy andhow to obtain relevant HTS codes, ECCNs, and other import/export data.

© 2013 National Instruments. All rights reserved.

374973B-01 Nov13