o r ta s o t 02 t es trpo n 03 c hứngc ỉg reengua d  04 c … · 2020-03-24 · staron solid...

29

Upload: others

Post on 05-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

ĐÁ NHÂN TẠO STARON

01 Giới thiệu02 Test report03 Chứng chỉ Greenguard 04 Chứng chỉ NSF05 Chứng chỉ IQNET06 Chứng chỉ khác07 07 MSDS08 Bảo hành

Page 2: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

ĐÁ NHÂN TẠO CAO CẤP

STARON

Staron là thương hiệu đá nhân tạo solid surface

của Lotte Advanced Materials đến từ Hàn

Quốc. Được mệnh danh là dòng đá nhân tạo

cao cấp tại Hàn Quốc, Staron hứa hẹn là vật liệu

tối ưu thế hệ mới trong thiết kế nội thất.

Staron solid surface được phát triển từ năm

1992 với sự đa dạng về màu sắc đáp ứng được

bất kỳ nhu cầu thiết kế nào. Với nhiều ưu điểm

vượt trội, đá nhân tạo Staron được sử dụng rộng

rãi trong các ứng dụng nội và ngoại thất ở các

khu dân cư và thương mại.

Staron đa dạng màu sắc với nhiều dòng sản

phẩm: Supreme, Solid, Sanded, Aspen, Pebble,

Quarry, Crystal, Metallic, Tempest, Evermoin.

STARON

SOLID SURFACE

Staron is a solid surface brand of Lotte

Advanced Materials from Korea. Dubbed as

a high-end artificial stone line in Korea, Staron

is promised to be the optimal new generation

material in interior design.

Staron solid surface has been developed since

1992 with a variety of colors to meet any design

needs. With many outstanding advantages,

Staron artificial stone is widely used in interior

and exterior applications in residential and

commercial areas.

Staron has a variety of colors with many

product lines: Supreme, Solid, Sanded, Aspen,

Pebble, Quarry, Crystal, Metallic, Tempest,

Evermoin.

Mẫu

(Pattern)

Độ dày

(Thickness)

Rộng

(Width)

Dài

(Length)

SOLID

SANDED

ASPEN

6mm 760mm 2,500mm

12mm 760mm 3,680mm

PEBBLE

METALLIC

QUARY

TEMPEST

SUPREME

12mm 760mm 3,680mm

Page 3: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea
Page 4: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

Test Completion Date : 2017.07.11.

Receipt Date : 2017.07.03.

Address : 56, Gosan-ro, Uiwang-si, Gyeonggi-do, Korea 16073

Company name: Lotte Advanced Materials Co., Ltd.

Representative : Lee Ja Hyung

Report No : TAK-016406

98, Gyoyukwon-ro, Gwacheon-si, Gyeonggi-do, 13810, Rep. of KOREA TEL 82-2-2164-0011 FAX 82-2-2634-1008

Sample name : Artificial Marble (STARON)

Test Results

TEST ITEM UNIT SAMPLE RESULT TEST METHOD

ASTM D792-13(Method A)1.78--Specific Gravity((23/23) ℃)

ASTM D570-98(2010)e10.03-%Water Absorption(24 h Immersion)

ASTM D2583-13a67--Barcol Hardness

ASTM D785-08(2015)(Procedure A)

93--Rockwell Hardness(HRM)

ASTM D256-10e1(Method A)

18-J/mIzod Impact Strength

ASTM D638-14(*)36.4-MPaTensile Strength

ASTM D790-15e2(**)53.5-MPaFlexural Strength

ASTM D790-15e2(**)10.5-GPaFlexural Modulus of Elasticity

JIS K 6911 : 19956.5×10-1/℃Thermal Expansion

ASTM D648-16(Method B)109-℃Deflection Temperature Under Load(1.82 MPa)

JIS K 6902 : 2007(Method B)No Defects--Heat Resistance(Appearance)

JIS K 6902 : 2007(Method B)No Defects--Heat Water Resistance(Appearance)

By The Client(***)No Defects--Dropping Impact Test

- Next Page -

Technical Manager: You SeokTel: 1577-0091(ARS ①→④)

Tested by JungyuseokE-mail: [email protected]

Jungyuseok You Seok

Korea Testing & Research Institute

2017.07.11.

21 of

President

전자문서본(Electronic Copy)

QR Code for forgery

Electronic copy is for your reference only.

Page:

Page 5: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

Test Completion Date : 2017.07.11.

Receipt Date : 2017.07.03.

Address : 56, Gosan-ro, Uiwang-si, Gyeonggi-do, Korea 16073

Company name: Lotte Advanced Materials Co., Ltd.

Representative : Lee Ja Hyung

Report No : TAK-016406

98, Gyoyukwon-ro, Gwacheon-si, Gyeonggi-do, 13810, Rep. of KOREA TEL 82-2-2164-0011 FAX 82-2-2634-1008

Sample name : Artificial Marble (STARON)

Test Results

TEST ITEM UNIT SAMPLE RESULT TEST METHOD

* Speed of Testing: 5 mm/min, Specimen Type: Type I** Speed of Testing: 5.0 mm/min, Support Span: 190 mm*** Fall height : 2 m, 112 g(bearing ball), Test specimen : Concrete, Appearance : Crack

- Usage of Report: QUALITY CONTROL

NOTE : 1. The test results of this test report are only limited in to the samples and sample names provided by the client and do not guarantee the quality of all products of the client. You can check website (www.ktr.or.kr) or QR code to verify the authenticity of the certificate.2. This test report shall be used only within the purpose of its defined usage and shall not be used for public relation, advertisement and lawsuit.3. This test report is only valid when printed on KTR original report paper with hologram and when re-issued by KTR. The copy and the electronic file of the test report are only for reference.

Technical Manager: You SeokTel: 1577-0091(ARS ①→④)

Tested by JungyuseokE-mail: [email protected]

Jungyuseok You Seok

Korea Testing & Research Institute

2017.07.11.

22 of

President

전자문서본(Electronic Copy)

QR Code for forgery

Electronic copy is for your reference only.

Page:

A4(210 Χ 297)KTR-QP-T09-F01-05(01)

Page 6: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea
Page 7: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

LOTTE ADVANCEDMATERIALS CO., LTDStaron® solid surface sheetsRestrictions:

Certified

Status

09/18/2007 - 09/18/2019

Certificate Period

4109-410

Certificate Number

UL 2818 - 2013 Standard for Chemical Emissions for Building Materials, Finishes and Furnishings

CERTIFICATEOF COMPLIANCE

Building materials are determined compliant in accordance with an Office environment with an air change of 0.68 hr¯¹ and a loading of 3.20 m².

Products tested in accordance with UL 2821 test method to show compliance to emission limits in UL 2818, Section 7.1.

GREENGUARD Certification Criteria for Building Products and Interior Finishes

Criteria CAS NumberMaximum Allowable

Predicted Concentration Units

TVOC(A) - 0.50 mg/m³

Formaldehyde 50-00-0 61.3 (50 ppb) µg/m³

Total Aldehydes (B) - 0.10 ppm

Particle Matter less than 10 µm (C) - 50 µg/m³

4-Phenylcyclohexene 4994-16-5 6.5 µg/m³

Individual VOCs (D) - 1/10th TLV -

(A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentra�ons for GREENGUARD (0.50 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.1.

(B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.

(C) Par�cle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems.

(D) Allowable levels for chemicals not listed are derived from 1/10th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinna�, OH 45211-4438).

LOTTE ADVANCED MATERIALS CO., LTDStaron® solid surface Sinks and BowlsRestrictions:

Certified

Status

09/18/2007 - 09/18/2019

Certificate Period

4112-410

Certificate Number

UL 2818 - 2013 Standard for Chemical Emissions for Building Materials, Finishes and Furnishings

CERTIFICATEOF COMPLIANCE

Building materials are determined compliant in accordance with an Office environment with an air change of 0.68 hr¯¹ and a loading of 3.20 m².

Products tested in accordance with UL 2821 test method to show compliance to emission limits in UL 2818, Section 7.1.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

GREENGUARD Certification Criteria for Building Products and Interior Finishes

Criteria CAS NumberMaximum Allowable

Predicted Concentration Units

TVOC(A) - 0.50 mg/m³

Formaldehyde 50-00-0 61.3 (50 ppb) µg/m³

Total Aldehydes (B) - 0.10 ppm

Particle Matter less than 10 µm (C) - 50 µg/m³

4-Phenylcyclohexene 4994-16-5 6.5 µg/m³

Individual VOCs (D) - 1/10th TLV -

(A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentra�ons for GREENGUARD (0.50 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.1.

(B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.

(C) Par�cle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems.

(D) Allowable levels for chemicals not listed are derived from 1/10th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinna�, OH 45211-4438).

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

LOTTE ADVANCED MATERIALS CO., LTDStaron® Tempest™Restrictions:

Certified

Status

09/18/2007 - 09/18/2019

Certificate Period

4110-410

Certificate Number

UL 2818 - 2013 Standard for Chemical Emissions for Building Materials, Finishes and Furnishings

CERTIFICATEOF COMPLIANCE

Building materials are determined compliant in accordance with an Office environment with an air change of 0.68 hr¯¹ and a loading of 3.20 m².

Products tested in accordance with UL 2821 test method to show compliance to emission limits in UL 2818, Section 7.1.

GREENGUARD Certification Criteria for Building Products and Interior Finishes

Criteria CAS NumberMaximum Allowable

Predicted Concentration Units

TVOC(A) - 0.50 mg/m³

Formaldehyde 50-00-0 61.3 (50 ppb) µg/m³

Total Aldehydes (B) - 0.10 ppm

Particle Matter less than 10 µm (C) - 50 µg/m³

4-Phenylcyclohexene 4994-16-5 6.5 µg/m³

Individual VOCs (D) - 1/10th TLV -

(A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentra�ons for GREENGUARD (0.50 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.1.

(B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.

(C) Par�cle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems.

(D) Allowable levels for chemicals not listed are derived from 1/10th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinna�, OH 45211-4438).

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

Page 8: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

Restrictions:

LOTTE ADVANCED MATERIALS CO., LTDStaron® solid surface sheets

4109-420

Certificate Number

09/18/2007 - 09/18/2019

Certificate Period

Certified

Status

UL 2818 - 2013 Gold Standard for Chemical Emissions for Building Materials, Finishes and Furnishings

CERTIFICATEOF COMPLIANCE

Building products and interior finishes are determined compliant in accordance with California Department of Public Health (CDPH) Standard Method V1.2-2017 using an Office and Classroom Environment.

Product tested in accordance with UL 2821 test method to show compliance to emission limits on UL 2818. Section 7.1 and 7.2.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

Restrictions:

LOTTE ADVANCED MATERIALS CO., LTDStaron® solid surface Sinks and Bowls

4112-420

Certificate Number

09/18/2007 - 09/18/2019

Certificate Period

Certified

Status

UL 2818 - 2013 Gold Standard for Chemical Emissions for Building Materials, Finishes and Furnishings

CERTIFICATEOF COMPLIANCE

Building products and interior finishes are determined compliant in accordance with California Department of Public Health (CDPH) Standard Method V1.2-2017 using an Office and Classroom Environment.

Product tested in accordance with UL 2821 test method to show compliance to emission limits on UL 2818. Section 7.1 and 7.2.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

Restrictions:

LOTTE ADVANCED MATERIALS CO., LTDStaron® Tempest™

4110-420

Certificate Number

09/18/2007 - 09/18/2019

Certificate Period

Certified

Status

UL 2818 - 2013 Gold Standard for Chemical Emissions for Building Materials, Finishes and Furnishings

CERTIFICATEOF COMPLIANCE

Building products and interior finishes are determined compliant in accordance with California Department of Public Health (CDPH) Standard Method V1.2-2017 using an Office and Classroom Environment.

Product tested in accordance with UL 2821 test method to show compliance to emission limits on UL 2818. Section 7.1 and 7.2.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

GREENGUARD Gold Certification Criteria for Building Products and Interior Finishes

Criteria CAS NumberMaximum Allowable

Predicted Concentration Units

TVOC (A) - 0.22 mg/m³

Formaldehyde 50-00-0 9 (7.3 ppb) µg/m³

Total Aldehydes (B) - 0.043 ppm

4-Phenylcyclohexene 4994-16-5 6.5 µg/m³

Particle Matter less than 10 µm (C) - 20 µg/m³

1-Methyl-2-pyrrolidinone (D) 872-50-4 160 µg/m³

Individual VOCs (E) -1/2 CREL

or1/100th TLV

-

(A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentra�ons for GREENGUARD Gold (0.22 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.2.

(B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.

(C) Par�cle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems.

(D) Based on the CA Prop 65 Maximum Allowable Dose Level for inhala�on of 3,200 μg/day and an inhala�on rate of 20 m³/day

(E) Allowable levels for chemicals not listed are derived from the lower of 1/2 the California Office of Environmental Health Hazard Assessment (OEHHA) Chronic Reference Exposure Level (CREL) as required per the CDPH/EHLB/Standard Method v1.2 and BIFMA level credit 7.6.2 and 1/100th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinna�, OH 45211-4438).

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

GREENGUARD Gold Certification Criteria for Building Products and Interior Finishes

Criteria CAS NumberMaximum Allowable

Predicted Concentration Units

TVOC (A) - 0.22 mg/m³

Formaldehyde 50-00-0 9 (7.3 ppb) µg/m³

Total Aldehydes (B) - 0.043 ppm

4-Phenylcyclohexene 4994-16-5 6.5 µg/m³

Particle Matter less than 10 µm (C) - 20 µg/m³

1-Methyl-2-pyrrolidinone (D) 872-50-4 160 µg/m³

Individual VOCs (E) -1/2 CREL

or1/100th TLV

-

(A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentra�ons for GREENGUARD Gold (0.22 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.2.

(B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.

(C) Par�cle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems.

(D) Based on the CA Prop 65 Maximum Allowable Dose Level for inhala�on of 3,200 μg/day and an inhala�on rate of 20 m³/day

(E) Allowable levels for chemicals not listed are derived from the lower of 1/2 the California Office of Environmental Health Hazard Assessment (OEHHA) Chronic Reference Exposure Level (CREL) as required per the CDPH/EHLB/Standard Method v1.2 and BIFMA level credit 7.6.2 and 1/100th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinna�, OH 45211-4438).

UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

GREENGUARD Gold Certification Criteria for Building Products and Interior Finishes

Criteria CAS NumberMaximum Allowable

Predicted Concentration Units

TVOC (A) - 0.22 mg/m³

Formaldehyde 50-00-0 9 (7.3 ppb) µg/m³

Total Aldehydes (B) - 0.043 ppm

4-Phenylcyclohexene 4994-16-5 6.5 µg/m³

Particle Matter less than 10 µm (C) - 20 µg/m³

1-Methyl-2-pyrrolidinone (D) 872-50-4 160 µg/m³

Individual VOCs (E) -1/2 CREL

or1/100th TLV

-

(A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentra�ons for GREENGUARD Gold (0.22 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.2.

(B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.

(C) Par�cle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems.

(D) Based on the CA Prop 65 Maximum Allowable Dose Level for inhala�on of 3,200 μg/day and an inhala�on rate of 20 m³/day

(E) Allowable levels for chemicals not listed are derived from the lower of 1/2 the California Office of Environmental Health Hazard Assessment (OEHHA) Chronic Reference Exposure Level (CREL) as required per the CDPH/EHLB/Standard Method v1.2 and BIFMA level credit 7.6.2 and 1/100th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinna�, OH 45211-4438).

Page 9: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea
Page 10: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

P lace and date:

For the issuing office: Seoul 19 June, 2018 DNV GL- Business Assurance

18F, Kyobo Bldg., 1, Jongro, JongnoguSeoul, Korea

In-Kyoon AhnManagement Representative

Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. DNV GL Business Assurance Korea Ltd is accredited by Korea Accreditation Board (KAB) as a Quality Management System certification body (Accreditation number: KAB-QC-10). ACCREDITED UNIT: DNV GL Business Assurance Korea Ltd, 18F Kyobo Bldg., 1 Jong-ro, Jongno-gu, Seoul, Republic of Korea. TEL:+82 2 724 8413. dnvgl.co.kr/assurance

C ertificate No: 76730-2010-AQ-KOR-KAB

Initial certification date: 25 May, 2010

V alid: 18 June, 2018 - 18 June, 2021

This is to certify that the management system of

Lotte Advanced Materials Co., Ltd. 334-27, Yeosusandan-ro, Yeosu-si, Jeollanam-do, Korea and the sites as mentioned in the appendix accompanying this certificate has been found to conform to the Quality Management System standard: ISO 9001:2015, KS Q ISO 9001:2015

This certificate is valid for the following scope: Design, Development and Manufacture of ABS(ACRYLONITRILE BUTADIENE STYRENE), EP(ENGINEERING PLASTIC), PS(POLYSTRENE), SAN(STYRENE ACRYLONITRILE), EPS(EXPANDABLE POLYSTYRENE), SS(SOLID SURFACE), S&B(SINK & BOWL), PC(POLYCARBONATE) and QS(QUARTZ SURFACE).

C ertificate No: 76730-2010-AQ-KOR-KAB P lace and date: Seoul 19 June, 2018

Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. DNV GL Business Assurance Korea Ltd is accredited by Korea Accreditation Board (KAB) as a Quality Management System certifica tion body (Accreditation number: KAB-QC-10). ACCREDITED UNIT: DNV GL Business Assurance Korea Ltd, 18F Kyobo Bldg., 1 Jong-ro, Jongno-gu, Seoul, Republic of Korea. TEL:+82 2 724 8413. dnvgl.co.kr/assurance

Page 2 of 2

Appendix to Certificate Lotte Advanced Materials Co., Ltd. Locations included in the certification are as follows:

Site Name Site Address Site ScopeLotte Advanced Materials Co., Ltd. Yeosu Plant

334-27, Yeosusandan-ro, Yeosu-si, Jeollanam-do, Korea

Manufacture of ABS(ACRYLONITRILE BUTADIENE STYRENE), EP(ENGINEERING PLASTIC), PS(POLYSTRENE), SAN(STYRENE ACRYLONITRILE), EPS(EXPANDABLE POLYSTYRENE), SS(SOLID SURFACE), S&B(SINK & BOWL), PC(POLYCARBONATE) and QS(QUARTZ SURFACE).

Lotte Advanced Materials Co., Ltd. Uiwang HQ & R&D Center

56, Gosan-ro, Uiwang-si, Gyeonggi-do, Korea

Design, Development of ABS(ACRYLONITRILE BUTADIENE STYRENE), EP(ENGINEERING PLASTIC), PS(POLYSTRENE), SAN(STYRENE ACRYLONITRILE), EPS(EXPANDABLE POLYSTYRENE), SS(SOLID SURFACE), S&B(SINK & BOWL), PC(POLYCARBONATE) and QS(QUARTZ SURFACE).

Page 11: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea
Page 12: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

Copyright ⓒ LOTTE ADVANCED MATERIALS CO., LTD. All rights reserved. www.staron.com.au

TECHNICAL BULLETIN

SN-101-2016

Performance Properties - American Standard

STARON®

The information contained herein is provided by LOTTE ADVANCED MATERIALS and its subsidiaries and affiliates (collectively

referred to as “LOTTE ADVANCED MATERIALS”) for information purposes only and should be used by individuals with technical

experience and knowledge in the area. LOTTE ADVANCED MATERIALS does not make any representation or warranties of the

usefulness or expected result of the information, and does not assume any responsibility whatsoever related to the use of the

information. Exclusion of the implied warranties may not apply in certain jurisdictions.

PROPERTIES TYPICAL RESULTS TEST PROCEDURE

Tensile strength 6,000 psi ASTM D 638

Tensile modulus 600,000 psi ASTM D 638

Flexural strength 10,000 psi ASTM D 790

Flexural modulus 1,000,000 psi ASTM D 790

Elongation 0.50% ASTM D 638

Hardness 92 Rockwell “M” Scale

65 Barcol Impressor

ASTM D 785

ASTM D 2583

Thermal expansion 2.0 x 10-5 in/in F˚ ASTM D 696

Gloss (60 Gardner) Between 5 - 20 NEMA LD-3

Color stability No change-200hrs NEMA LD-3

Stain resistance Pass Rating 41 ANSI Z 124

Abrasion resistance Pass ANSI Z 124

Boiling water surface resistance No effect NEMA LD-3

High temperature resistance No effect NEMA LD-3

IZOD Impact resistance (notched) 0.28 ft.lbf/in ASTM D 256

Ball drop 1/2”

(12.3 mm) sheet 144” w/ 1/2 lb ball, No failure NEMA LD-3

Fungi and Bacterial resistance No growth ASTM G 21, G22

Specific gravity

Solid colors

Patterened colors

1.72

1.69

ASTM D 792

Water absorption 0.04%, (1/2”, 24hrs)

0.11%, (1/8”, 24hrs) ASTM D 570

Flammability

Flame spread

Smoke density

Class A / Class 1

10

10

UBC 8-1

ASTM E 84

ASTM E 84

Radiant heat resistance No visual effect NEMA LD-3

Toxicity 84.4g (Solid Color)

81.8g (Patterned Color)

Pittsburgh Test Protocol

(LC50 Test)

This Technical Bulletin is intended to provide guidelines for optimal fabrication, installation, and performance of LOTTE ADVANCED MATERIALS

products mentioned. Though the information contained herein is deemed reliable, none of the contents--including but not limited to the instructions,

techniques, graphics, and recommendations--is to be understood as implying legal liability of fitness for a specific purpose, any other type of warranty, or

being complete or absolute in its range and nature of information.

Depending on the user's particular application, all necessary measures must be taken to verify and test the adequacy for such needs or application. Any

information or recommendation herein is strictly for purposes of reference and as such, LOTTE ADVANCED MATERIALS assumes no responsibility for

its suitability or accuracy or the use of such information for products other than LOTTE ADVANCED MATERIALS Staron® solid surfaces & Radianz®

quartz surfaces.

Page 13: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

Copyright ⓒ LOTTE ADVANCED MATERIALS CO., LTD. All rights reserved. www.staron.com.au

TECHNICAL BULLETIN

SN-101-2016

Performance Properties - American Standard

TEMPEST®

The information contained herein is provided by LOTTE ADVANCED MATERIALS and its subsidiaries and affiliates (collectively

referred to as “LOTTE ADVANCED MATERIALS”) for information purposes only and should be used by individuals with technical

experience and knowledge in the area. LOTTE ADVANCED MATERIALS does not make any representation or warranties of the

usefulness or expected result of the information, and does not assume any responsibility whatsoever related to the use of the

information. Exclusion of the implied warranties may not apply in certain jurisdictions.

PROPERTIES TYPICAL RESULTS TEST PROCEDURE

Tensile strength 3,500 psi ASTM D 638

Tensile modulus 786,000 psi ASTM D 638

Flexural strength 6,500 psi ASTM D 790

Flexural modulus 950,000 psi ASTM D 790

Elongation 0.50% ASTM D 638

Hardness 88 Rockwell “M” Scale

54 Barcol Impressor

ASTM D 785

ASTM D 2583

Thermal expansion 2.3 x 10-5 in/in F˚

3.6 x 10-5 m/m °C ASTM D 696

Gloss (60 Gardner) Between 10 - 75 NEMA LD-3

Color stability Pass NEMA LD-3

Stain resistance Pass ANSI Z 124

Cleanability & Wear Pass ANSI Z 124

Boiling water surface resistance No effect NEMA LD-3

High temperature resistance No effect NEMA LD-3

IZOD Impact resistance (notched) 0.28 ft.lbf/in ASTM D 256

Ball drop 1/2”

(12.3 mm) sheet

1/2 lb ball

No failure, 93+ NEMA LD-3

Fungi and Bacterial resistance No growth ASTM G 21, G22

Specific gravity 1.6 ASTM D 792

Water absorption 0.04%, (1/2”, 24hrs) ASTM D 570

Flammability Class A / Class 1 ASTM E 84 / UBC 8-1

Food Equipment Materials Approved NSF/ANSI 51 (Food Zone)

This Technical Bulletin is intended to provide guidelines for optimal fabrication, installation, and performance of LOTTE ADVANCED MATERIALS

products mentioned. Though the information contained herein is deemed reliable, none of the contents--including but not limited to the instructions,

techniques, graphics, and recommendations--is to be understood as implying legal liability of fitness for a specific purpose, any other type of warranty, or

being complete or absolute in its range and nature of information.

Depending on the user's particular application, all necessary measures must be taken to verify and test the adequacy for such needs or application. Any

information or recommendation herein is strictly for purposes of reference and as such, LOTTE ADVANCED MATERIALS assumes no responsibility for

its suitability or accuracy or the use of such information for products other than LOTTE ADVANCED MATERIALS Staron® solid surfaces & Radianz®

quartz surfaces.

Page 14: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

1/6

○ Manufactrue

○ Supplier

- Not Classified

- The hazards of this product are associated with its fabrication. Such as sawing, routing and sanding can generate dust.

- Exposure to high concentration of dust or inhalation may cause respiratory irritation and sneeze. This information is according

to exposure limits of PMMA (Poly methyl matacrylate).

- Pictogram

none

- Signal word

none

- Hazard statement

none

- Precautionary statement

Prevention: Not Applicable, Respnse: Not Applicable, Storage: Not Applicable, Disposal: Not Applicable

- NFPA rating

Health : Not applicable, Flammability : Not applicable, Reactivity : Not applicable

2.2 Label elements

- FAX No. : +82-31-596-3882

2. HAZARD IDENTIFICATION

2.1 Classification of the substance or mixture

- Department : Technical Solution Team

- Telephone : +82-31-596-3861

- Emergency telephone : +82-31-596-3861

- Address : 56, Gosan-ro, Uiwang-si, Gyeonggi-do, Republic of Korea

- Telephone : +82-61-689-1151

- Emergency telephone : +82-61-689-1151

- FAX No. : +82-61-689-1759

- uses advised against

- Name of Supplier : LOTTE ADVANCED MATERIALS

: Do NOT use with strong acid or base chemicals

- Department : Development Team

Material Safety Data Sheet (MSDS)

STARON Solid Surface

Date of issue: 2010-10-04 Revision data : 2018-05-11 Version:

1. PRODUCT AND COMPANY IDENTIFICATION

1.1 Product Name

1.3 Detail of the supplier of the safety data sheet

- Name of Supplier : LOTTE ADVANCED MATERIALS

- Address : 334-27, Yeosusandan-ro, Yeosu-si, Jeollanam-do, Republic of Korea

- Staron solid surface

1.2 Product use

- Application : Kitchen top, counter top, interior wall, ect.

Page 15: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

2/6

- At room temperature, it does not have gas emissions. But under high temperature condition, small amount of acryl gas may be emitted.

Depending on time and temperature, the gas emission amount will be affected. The acryl gas may cause irritation or allergy on eye,

nose, skin and neck. Repeated and high concentrated exposure may cause headache, vomiting and bronchoalveolar inflammation.

Concentration

range(%)

40 - 45 %

55 - 60 %

< 1 %

< 1 %

7. HANDLING AND STORAGE

7.1. Precautions for safe handling

- When fabricating such as thermoforming, cutting and sanding, wear a proper protective gears.

7.2. Conditions for safe storage, including any incompatibilities

- Store in 15~23℃ temp. and dry condition inside or warehouse on flat ground.

- Large amount: Avoid generating dust in the air. Cleaning dust using vacuum cleaner and keep it into dry container.

6.2. Environmental precautions

- AIR: Avoid generation of dust and fine dust dispersed in the air

6.3. Methods and material for containment and cleaning up

- Small amount: Brush into dry container or bag.

-- Protective fire fighting clothing (including fire fighting helmet, coat, pants, boots and glove), Air supplied respirator.

6. ACCIDENTAL RELEASE MEASURES

6.1. Personal precautions, protective equipment and emergency procedures

- Proper personal protective equipment should be utilized when handling this material.

- Unsuitable extinguishing media : Not available

5.2 Special hazards arising from the substance or mixture

- Hazardous Product of Combustion: Carbon Oxides (CO, CO2), Various Hydrocarbons.

5.3 Advice for fire-fighters

5. FIRE FIGHTING MEASURES

5,1 Extinguishing Media

- Suitable extinguishing media : Dry chemical, carbon oxide, water spray and foam

4.3 Inhalation

- If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Follow instruction of doctor.

4.4 Ingestion

- If vomitting, rinse mouth and follow instruction of doctor.

4.2 Skin Conatact

- No hazard. Wash with soap and water.

Pigment Pigment Trade secret

Additives Additives

Aluminum Trihydrate ATH 21645-51-2

4. FIRST AID MEASURES

4.1 Eye Contact

- Rinse thoroughly with plenty of water for over 15 minute and call a doctor immidiately.

2.3. Other hazards

3. COMPOSITION/INFORMATION ON INGREDIENTS

Chemical Usual Name CAS No.

- Risk of Explosion or Fire: Staron solid surface has fire resistance but it has small risk of fire when it exposure to heat or fire.

Trade secret

ACRYLIC POLYMER PMMA 9011-14-7

Page 16: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

3/6

○ Respiratory protection

○ Eye Protection

○ Hand Protection

○ Skin protection

10. STABILITY AND REACTIVITY

10.1 Stability and Possibility of Hazardous Reaction

- Stability : Stable under room temperature and normal pressure

- Possibility of Hazardous Reaction: When cutting by saw or router, friction heat reach up to 300℃ temperature.

10.2 Conditions to avoid

- Avoid extreme heat

9.17 Decomposition No data

9.18 Viscosity Not applicable

9.19 Explosive properties No data

9.14 Relative density 1.6 ~ 1.8

9.15 Partition coefficient No data

9.16 Autoignition Temperature No data

9.11 Vapour pressure Not applicable

9.12 Water Solubility Not soluble in water

9.13 Vapour density Not applicable

9.8 Evaporation rate Not applicable

9.9 Flammability (solid, gas) Not applicable

9.10 Upper/lower flammability or explosive limits Not applicable

Not applicable

9.5 Boiling /Freezing point Not applicable

9.6 Boiling point/boiling range Not applicable

9.7 Flash point No data

- Physical state Solid (Sheet form)

- Color Various

9.2 Odor Minimal

9.3 Odor Threshold Not applicable

9.4 pH

8.1. Control parameters

- Occupational Exposure Limits : Not available

8.2 Appropriate engineering controls

- Not available

8.3 Individual protection measures, such as personal protective equipment

- Dust mask when exposure on high concentration of dust

* ACGIH = American Conference of Governmental Industrial Hygienists

- TWA : Not available

- STEL : Not available

- 0.3mg/㎥ OSHA TWA(Inhalable particles): Not available

8. EXPOSURE CONTROLS/PERSONAL PROTECTION

- 0.1mg/㎥ OSHA TWA(Respirable particles): Not available

- ACGIH : Not available

- Biological exposure limit : Not available

- Wear safely glasses

Methyl methacrylate monomer may be released. Dust may be flashed under ignition temp

- protectieve clothing

- Wear protective gloves

9. Physical and chemical properties

9.1 Appearance

Page 17: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

4/6

○ (Respratory system)

○ (ingestion)

○ (Eye, Skin)

○ Acute toxicity:

* Oral

* Dermal

* Inhalation

○ Skin corrosion/irritation

○ Eye corrosion/irritation

○ Respiratory sensitization

○ Skin Sensitization

○ Carcinogenic

○ Germ cell mutations

○ Reproductive toxicity

○ Specific target organ toxicity(single exposure)

○ Specific target organ toxicity(repeated exposure)

○ Aspiration hazard

[PMMA]

○ TLV-TWA =100ppm =410mg/m3 :ACGIH (1991-2

○ LD50/Oral/Rat =7,872mg/kg :RTECS, 47796

○ MMA contents may leave on cutting tool blade about 100ppm TLV. Ventilation will dilute the concentration.

○ Fish

12. ECOLOGICAL INFORMATION

12.1. Ecotoxicity

- Not available

- Not available

11.3. TOXICALOGICAL EFFECTS

- No data

- Not available

- Not available

- Not available

- Not available

- Not available

- Acute exposure : High concentration may cause difficulty with physical breathing.

- Not available

- Chronic overexposure: Not available

- Chronic overexposure: Not available

- Not available

- Not available

- :High concentration may cause difficulty with breathing.

- Organic reaction with digestive organs may cause irritation.

- Particles may cause irritation.

11.2. Toxicity and irritation

- Acute exposure : Organic reaction with digestive organs may cause irritation.

- Acute exposure : Particles may cause irritation.

- Chronic overexposure: Not available

10.3 Materials to avoid

- Acids, base, solvent, heat, spark, flame

10.4 Hazardous decomposition products

- Carbon oxides, Methyl methacrylate monomer, smog.

11. TOXICOLOGICAL INFORMATION

11.1 Information on toxicological effects

Page 18: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

5/6

○ Invertebrate

○ Algae

- Persistence : No data

- Degradability : No data

- Biodegradablility: No data

- Bioaccumulation: No data

15.1. Occupation safety and health acts

- Not available

15.3. Safety control of dangerous substances Act

15.2. Chemical Safety Assessment

- Not applicable

14.5. Environmental hazards

- Not available

14.6 Special precautions for user related to transport or transportation measures

- Not available

15. REGULATORY INFORMATION

- Not applicable

14.2 UN proper shipping name

- Not applicable

14.3 Transport hazard class(es)

- Not applicable

14.4 Packing group

- All disposal methods must be in compliance with all Federal, State/Provincial and local laws and regulations

13.2 Requore attention

- The user of this product must properly characterize the waste/ container generated from the use of this product in accordance with all applicable

federal, state and/or lacal laws and regulations in oerder to determine the proper disposal of the waste in accordance with all applicable federal,

state and/ or local laws and regulations

- Dispose of waste in accordance with local regulation

14. TRANSPORTATION INFORMATION

14.1 UN number

12.4. Mobility in soil

- Not available

12.5 Other adverse effects

- Not available

13. DISPOSAL CONSIDERATIONS

13.1 Waste treatment methods

- No data

- No data

12.2 Persistence/degradability

12.3 Bioaccumulative potential

- Not available

Page 19: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

6/6

○ Persistent Organic Pollutants Control Act

○ EU

* Confirm classific result : Not classified

* Harzard words Not applied

* Prevention measure: Not applied

○ U.S regulations

* OSHA Hazard Communication Standard (29 CFR 1910.119)

* CERCLA 103 (40CFR302.4)

* EPCRA 302 (40CFR355.30)

* EPCRA 304 (40CFR355.40)

* EPCRA 313 (40CFR372.65)

○ Rotterdam convention material

○ Stockholm convention material

○ Montreal Protocol material

○ TSCA (US Toxic Substances Control Act): In compliance with TSCA Inventory requirements for commercial purposes

16.1 Sources of Data

16.4 Others

16.2 Creation Date

- 2010-10-04

16.3 Number of Revision and Latest Revisioni Date

-6th : 2018.05.11

- Not applicable

- Not applicable

- Not applicable

- Not applicable

- Not applicable

16. OTHER INFORMATION

- Not available

15.5. Foreign legal

- Not available

- Not applicable

- Not applicable

- Not applicable

- Not available

15.4. Wastes control Act

Page 20: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

BẢNG HƯỚNG DẪN AN TOÀN VẬT LIỆU (MSDS)

STARON Solid Surface

4 tháng 10 năm 2010 Ngày nâng cấp dữ liệu: 11 tháng 5 năm 2018

1. SẢN PHẨM VÀ THÔNG TIN NHÀ SẢN XUẤT

1.1 Tên sản phẩm

Đá Solid surface thương hiệu Staron 1.2 Sử dụng sản phẩm Ứng dụng: Mặt bếp, mặt bàn, tường nội thất, ect. Chống chỉ định: Không sử dụng với hóa chất axit hoặc hóa chất mạnh. 1.3 Chi tiết về nhà cung cấp bảng dữ liệu an toàn

o Thông tin nhà sản xuất - Tên : LOTTE ADVANCED MATERIALS - Địa chỉ : 334-27, Yeosusandan-ro, Yeosu-si, Jeollanam-do - Xuất xứ : Hàn Quốc - Bộ phận quản lý : Phòng Phát triển (Development Team) - Điện thoại : + 82-61-689-1151 - FAX : + 82-61-689-1759 o Thông tin nhà phân phối : - Tên : SAMSUNG INTERIOR - Địa chỉ : 19W Nguyễn Hữu Cảnh – Bình Thạnh - HCM - Bộ phận quản lý : Samsung Interior - Điện thoại : 028 3 7447 333 - 090 2580 097

2. CẢNH BÁO NGUY HIỂM

2.1 Phân loại chất hoặc hỗn hợp - Các mối nguy hiểm của sản phẩm này có liên quan đến việc gia công nó. Chẳng hạn như cưa, định tuyến

và chà nhám có thể tạo ra bụi.

- Tiếp xúc với nồng độ cao của bụi hoặc hít phải có thể gây kích ứng đường hô hấp và hắt hơi. Thông tin

này dựa trên bảng tính phơi nhiễm của PMMA (Poly methyl methacrylate).

2.2 Nhãn dán sản phẩm:

- Hình ảnh: Không - Từ ngữ cảnh báo: Không - Thông báo cảnh báo: Không - Thông báo phòng ngừa: Không - Phòng ngừa: Không - Phản ứng: Không - Bảo quản: Không - Xử lý: Không áp dụng - Xếp hạng NFPA - Ảnh hưởng sức khỏe: Không gây ảnh hưởng sức khỏe - Tính dễ cháy: Không - Độ phản ứng: Không

Page 21: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

2.3. Các mối nguy hiểm khác

- Tại nhiệt độ phòng, chất liệu không tạo ra khí thải. Nhưng trong điều kiện nhiệt độ cao, một lượng nhỏ khí acrylic có thể được phát ra.

- Tùy thuộc vào thời gian và nhiệt độ, lượng khí thải sẽ bị ảnh hưởng. Khí acrylic có thể gây kích ứng hoặc dị ứng trên mắt, mũi, da và cổ. Phơi nhiễm liên tục và tập trung cao có thể gây đau đầu, nôn mửa và viêm phế quản.

3. THÔNG TIN VỀ THÀNH PHẦN HÓA HỌC

Tên chất hóa học Tên thường dùng CAS No. Phạm vi nồng độ (%) ACRYLIC POLYMER PMMA 9011-14-7 40 - 45 % Aluminum Trihydrate ATH 21645-51-2 55 - 60 % Hạt màu Hạt màu Trade secret < 1 % Phụ gia Phụ gia Trade secret < 1 %

4. CÁC BIỆN PHÁP XỬ LÝ ĐẦU TIÊN KHI CÓ SỰ CỐ XẢY RA 4.1 Tiếp xúc với mắt

- Rửa kỹ với nước trong ít nhất 15 phút và gọi bác sĩ ngay lập tức.

4.2 Tiếp xúc da - Không nguy hiểm. Rửa bằng xà phòng và nước.

4.3 Hít phải - Nếu thở khó khăn, hãy đưa nạn nhân ra nơi thoáng khí và giữ yên ở tư thế thoải mái để thở. Làm theo

chỉ dẫn của bác sĩ.

4.4 Nuốt phải - Nếu nôn, súc miệng và làm theo chỉ dẫn của bác sĩ.

5. BIỆN PHÁP XỬ LÝ KHI CHÁY NỔ

5.1 Phương tiện chữa cháy - Các phương tiện chữa cháy phù hợp: Hóa chất khô, oxit carbon, xịt nước và bọt - Phương tiện chữa cháy không phù hợp: Không áp dụng

5.2 Các mối nguy hiểm đặc biệt phát sinh từ các chất hoặc hỗn hợp

- Sản phẩm nguy hiểm của quá trình đốt cháy: Carbon Oxide (CO, CO2), Hydrocarbon khác nhau. - Nguy cơ nổ hoặc cháy: Đá Solid surface Staron có khả năng chống cháy nhưng nó có rủi ro cháy nhỏ khi

tiếp xúc với nhiệt hoặc lửa.

6. CÁC BIỆN PHÁP ĐƯỢC KHUYẾN NGHỊ

6.1. Phòng ngừa cá nhân, thiết bị bảo vệ và quy trình khẩn cấp - Thiết bị bảo vệ cá nhân: Sử dụng các sản phẩm chuyên dụng khi xử lý vật liệu này.

6.2. Phòng ngừa môi trường - Mục đích: Tránh phát sinh bụi và bụi mịn phát tán trong không khí

6.3. Phương pháp và vật liệu để ngăn chặn rò rỉ và phương pháp tẩy rửa làm sạch - Số lượng nhỏ: Thu vào hộp hoặc túi khô. - Số lượng lớn: Tránh tạo ra bụi trong không khí. Làm sạch bụi bằng máy hút bụi và giữ nó trong thùng

chứa

7. VẬN CHUYỂN VÀ BẢO QUẢN

7.1. Thận trọng để xử lý an toàn

Page 22: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

- Khi chế tạo như tạo hình, cắt và chà nhám, mặc một bánh răng bảo vệ thích hợp.

7.2. Điều kiện để cất giữ an toàn - Lưu trữ trong nhiệt độ 15 ~ 23 ° C và điều kiện khô bên trong hoặc kho trên mặt đất bằng phẳng.

8. KIỂM SOÁT TIẾP XÚC / BẢO VỆ CÁ NHÂN 8.1. Thông số điều khiển

- Giới hạn phơi nhiễm nghề nghiệp: Không áp dụng - TWA: Không áp dụng - STEL: Không áp dụng - 0,3mg / m3 OSHA TWA (Các hạt có thể hít vào): Không áp dụng - 0,1mg / m3 OSHA TWA (Các hạt có thể hô hấp): Không áp dụng - ACGIH: Không áp dụng - Giới hạn phơi nhiễm sinh học: Không có sẵn

* ACGIH = Hội nghị vệ sinh công nghiệp chính phủ Mỹ

8.2 Kiểm soát kỹ thuật phù hợp: - Không áp dụng

8.3 Các biện pháp bảo vệ cá nhân, như thiết bị bảo vệ cá nhân - Bảo vệ hô hấp: Mặt nạ chống bụi khi tiếp xúc với bụi nồng độ cao - Bảo vệ mắt: Đeo kính an toàn - Bảo vệ tay: Đeo găng tay bảo vệ - Bảo vệ da: Bảo vệ quần áo

9. Tính chất vật lí và hóa học

9.1 Hình thức

- Trạng thái vật lý Chất rắn (Dạng tấm) - Màu sắc Khác nhau

9.2 Mùi Tối thiểu 9.3 Ngưỡng mùi Không áp dụng 9.4 pH Không áp dụng 9.5 Điểm sôi / Điểm đóng băng Không áp dụng 9.6 Điểm sôi / Phạm vi sôi Không áp dụng 9.7 Điểm chớp cháy: Không áp dụng 9.8 Tốc độ bay hơi: Không áp dụng 9.9 Tính dễ cháy (rắn, khí): Không áp dụng 9.10 Giới hạn dễ cháy trên / dưới hoặc giới hạn nổ Không áp dụng 9.11 Áp suất hơi: Không áp dụng 9.12 Độ hòa tan trong nước Không tan trong nước 9.13 Mật độ hơi Không áp dụng 9.14 Mật độ tương đối 1.6 ~ 1.8 9.15 Hệ số phân vùng Không có dữ liệu 9.16 Nhiệt độ tự động Không có dữ liệu 9.17 Phân hủy Không có dữ liệu 9.18 Độ nhớt Không áp dụng 9.19 Thuộc tính nổ Không có dữ liệu

10. ĐỘ ỔN ĐỊNH VÀ PHẢN ỨNG

10.1 Tính ổn định và khả năng của phản ứng nguy hiểm - Ổn định: Ổn định dưới nhiệt độ phòng và áp suất bình thường - Khả năng phản ứng nguy hiểm: - Khi cắt bằng cưa hoặc thiết bị định tuyến, nhiệt ma sát đạt tới nhiệt độ 300°C.

Page 23: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

- Methyl methacrylate monomer có thể phát tán ra không khí. Bụi có thể bị lóe lên dưới nhiệt độ đánh lửa.

10.2 Điều kiện cần tránh - Tránh nhiệt độ quá cao

10.3 Vật liệu cần tránh - Axit, bazơ, dung môi, nhiệt, tia lửa, ngọn lửa

10.4 Sản phẩm phân hủy nguy hiểm - Oxit carbon, monomer Methyl methacrylate, sương mù.

11. THÔNG TIN ĐỘC TÍNH

11.1 Thông tin về tác dụng độc hại o Hệ hô hấp: Nồng độ cao có thể gây khó thở. o Tiêu hóa: Phản ứng hữu cơ với các cơ quan tiêu hóa có thể gây kích ứng. o Mắt, da: Các hạt có thể gây kích ứng.

11.2. Độc tính và kích ứng o Độc tính cấp tính:

* Đường uống - Cấp tính: Phản ứng hữu cơ với các cơ quan

tiêu hóa có thể gây kích ứng. - Phơi nhiễm mãn tính: Không áp dụng

*Tiếp xúc da

- Tiếp xúc cấp tính: Các hạt có thể gây kích ứng - Tiếp xúc quá mức mãn tính: Không áp dụng

* Hít phải

- Tiếp xúc cấp tính: Nồng độ cao có thể gây khó thở

- Tiếp xúc quá mức mãn tính: Không có sẵn

o Ăn mòn / kích ứng da - Không áp dụng

o Ăn mòn / kích ứng mắt

- Không áp dụng

o Nhạy cảm hô hấp

- Không áp dụng

o Nhạy cảm với da - Không áp dụng

o Gây ung thư

- Không áp dụng

o Đột biến tế bào mầm - Không áp dụng - o Độc tính sinh sản

- Không áp dụng

o Độc tính cơ quan đích cụ thể (phơi nhiễm đơn)

- Không áp dụng

o Độc tính cơ quan đích cụ thể (tiếp xúc nhiều lần)

- Không áp dụng

11.3 Độc lực [PMMA]

o TLV-TWA = 100ppm = 410mg / m3: ACGIH (1991-2) o LD50 / Uống / Chuột = 7,872mg / kg: RTECS, 47796 o Hàm lượng MMA có thể để lại trên lưỡi dao công cụ khoảng 100ppm TLV. Thông gió sẽ làm loãng nồng

độ.

12. TÁC ĐỘNG SINH THÁI

12.1. Độc tính sinh thái - Cá: Không có dữ liệu - Động vật không xương sống: Không có dữ liệu

Page 24: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

- Tảo: Không có dữ liệu

12.2 Độ bám dính / Phân hủy - Kiên trì: Không có dữ liệu - Phân hủy: Không có dữ liệu

12.3 Tiềm năng tích lũy sinh học - Khả năng phân hủy sinh học: Không có dữ liệu - Tích lũy sinh học: Không có dữ liệu

12.4. Tính di động trong đất - Không có sẵn

12.5 Tác dụng phụ khác: - Không áp dụng

13. TƯ VẤN TRANH CHẤP

13.1 Phương pháp xử lý chất thải - Tất cả các phương pháp xử lý phải tuân thủ tất cả các luật và quy định của Liên bang, Tiểu bang / Tỉnh

và địa phương nơi sử dụng.

13.2 Yêu cầu sự chú ý - Người sử dụng sản phẩm này phải mô tả đúng chất thải / thùng chứa được tạo ra từ việc sử dụng sản

phẩm này theo tất cả các luật và quy định hiện hành của liên bang, tiểu bang và / hoặc địa phương để xác định việc xử lý chất thải phù hợp theo tất cả các quy định hiện hành luật và quy định của liên bang, tiểu bang và / hoặc địa phương

- Xử lý chất thải theo quy định của địa phương

14. THÔNG TIN VẬN TẢI 14.1 Số UN

- Không áp dụng

14.2 Tên vận chuyển thích hợp của Liên Hợp Quốc - Không áp dụng

14.3 Lớp nguy hiểm vận chuyển - Không áp dụng

14.4 Nhóm đóng gói - Không áp dụng

14.5. Mối nguy hiểm môi trường - Không có

14.6 Các biện pháp phòng ngừa đặc biệt cho người dùng liên quan đến các biện pháp vận chuyển hoặc vận chuyển

- Không có

15. THÔNG TIN QUY ĐỊNH 15.1. An toàn và sức khỏe nghề nghiệp

- Không áp dụng

15.2. Đánh giá an toàn hóa chất - Không áp dụng

15.3. Kiểm soát an toàn các chất nguy hiểm Đạo luật - Không áp dụng

Page 25: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

15.4. Đạo luật kiểm soát chất thải: - Không áp dụng

15.5. Pháp luật nước ngoài ○ Đạo luật kiểm soát chất ô nhiễm hữu cơ lâu dài: Không có sẵn ○ EU

- Xác nhận kết quả phân loại: Không được phân loại - Từ ngữ cảnh báo: Không áp dụng - Biện pháp phòng ngừa: Không áp dụng

○ Đạo luật Mỹ

- OSHA Hazard Communication Standard (29 CFR 1910.119) - Không áp dụng - CERCLA 103 (40CFR302.4) - Không áp dụng - EPCRA 302 (40CFR355.30) - Không áp dụng - EPCRA 304 (40CFR355.40) - Không áp dụng - EPCRA 313 (40CFR372.65) - Không áp dụng

○ Tài liệu tham khảo Hội Nghị Rotterdam

- Không áp dụng ○ Tài liệu tham khảo Hội Nghị Stockholm

- Không áp dụng ○ Tài liệu Nghị định thư Montreal

- Không áp dụng ○ TSCA (Đạo luật kiểm soát chất độc hại của Hoa Kỳ):

- Tuân thủ các yêu cầu TSCA Hàng tồn kho cho mục đích thương mại

16. THÔNG TIN KHÁC 16.1 Nguồn dữ liệu

16.2 Ngày khởi tạo: 4 tháng 10 năm 2010

16.3 Số lần sửa đổi và ngày sửa đổi mới nhất 11 tháng 5 năm 2018

16.4 Thông tin khác

Page 26: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

www.staron.comCopyright ⓒ Lotte Chemical Corp. All rights reserved.

WARRANTY

RESIDENTIAL10-YEAR LIMITED

WARRANTY

Permanently installed Staron Solid Surfaces sheets and shapes Lotte Chemical Corp. to the original owner. Staron

Solid Surfaces must be fabricated and installed by Staron certified Fabricator/Installer, used and maintained in

accordance with instructions provided by Lotte Chemical Corp.. Lotte Chemical Corp. at its sole option will repair or

replace, without charge, such Product if it fails due to a manufacture defect during the first ten (10) years after the date of

initial installation. This includes necessary real cost charges needed to repair or replace the Product. Although Lotte

Chemical Corp. shall make its best effort to repair or replace with the best possible color match to the original as possible,

Lotte Chemical Corp. cannot guarantee the exact color in the event of repair or replacement. All instructions for filling a

claim under this limited warranty are available from your dealer and fabrication/installation source or by contacting Lotte

Chemical Corp. directly.

This limited warranty is transferable during the 10-year period following initial installation only when the new owner notifies

Lotte Chemical Corp. in writing.

This warranty excludes the following:

Lotte Chemical Corp.’s obligation hereunder is limited solely to the repair or replacement including necessary reasonable

real cost charges of the Products purchased hereunder. Except as to what is stated in this limited warranty herein, Lotte

Chemical Corp. makes no warranties, express or implied, in respect to the Product, including, but not limited to, any

implied warranty of merchantability or fitness for a particular purpose, and all such warranties hereby are expressly

disclaimed. Lotte Chemical Corp. does not warrant that the Product will meet the end users’ requirements. Lotte Chemical

Corp. shall not be liable for incidental, consequential, indirect, special, punitive, or exemplary damages of any kind,

including lost good will, lost profits, lost business, or other indirect economic damages, and further including injury to

property, whether such claim is based on theories of contract, negligence, tort (including strict liability) or otherwise, as a

result of breach of any warranty regardless of whether Lotte Chemical Corp. was advised, had other reason to know, or in

fact knew of the possibility of such damages.

SOME COUNTRIES, STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION STATED

ABOVE, SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY

GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS, WHICH WILL VARY FROM

COUNTRY TO COUNTRY, STATE TO STATE OR PROVINCE TO PROVINCE

Effective as September, 2015

01. Minor conditions such as stains, scratches, water spots and

burns;

02. Failure to comply with Lotte Chemical Corp.’s instructions

including

fabrication, installation, care, maintenance, etc;

03. Any products moved from their original place of installation;

04 Seam appearance of any adhesive, caulk or other accessory

items;

05. Color variation from the sample;

06. Color variation within different lots;

07. Exact color match as a result of Product replacement or

repair is not guaranteed;

08. Failure caused by other substructure support;

09. Misuse, abuse (including impact damage and contact with

chemical reagents not intended for use with Product);

10. Improper fabrication, installation, handling or maintenance;

11. Damage caused by excessive heat; or by an act of nature;

12. Workmanship of Fabricators or Installers;

13. Damages from other than manufacturing defect;

14. Any Product installed or located outdoors, such as outdoor

kitchens, BBQ work surfaces, or in heated areas such as

saunas, steam rooms, and shower pans;

15. In-Carton products including components made from

Staron® ;

16. Any Product installed in recreational vehicles;

17. Any Product fabricated and installed in commercial

applications;

18. Fabrication, Installation, Modification or Repairs made by

other than Staron® CFI (Certified Fabricator Installer);

19. Same color and veined intensity between sheets in

SUPREME collection. ((Veining may vary from sheet tosheet and also within a sheet. Special consideration has to be taken into any joint and coved up-stands.)

Page 27: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

www.staron.comCopyright ⓒ Lotte Chemical Corp. All rights reserved.

WARRANTY

RESIDENTIAL 10-YEAR LIMITED

WARRANTY

This warranty cannot be modified, amended, or in any way altered except by an instrument in writing signed by

an authorized officer of Lotte Chemical Corp..

Effective as September, 2015

Warranty Service:

To request warranty service, contact your original fabricator/installer. You must present the original sales receipt or

produce proof of purchase and installation of Staron® Solid Surfaces, which clearly proves the Product purchase and

date of installation, in order to obtain service under this limited warranty. For more information about this warranty,

please contact to Lotte Chemical Corp. at the address below:

LOTTE Chemical Deutschland GMBHKölner Str. 12 65760 Eschborn, GermanyTEL +49 6196 77 272 75

LOTTE Chemical Thailand Co., Ltd.16th Floor, Empire Tower, Unit 1602-1603, 1 South Sathorn RD,Yannawa, Bangkok, Thailand. 10120Tel. +66-2-624-6737

LOTTE Chemical Deutschland GMBH-REPRESENTATIVE OFFICE(DUBAI)Office No 1702, Arenco Tower, Media City, Dubai, UAE. PO BOX 48969Email [email protected]. +971-4-245-1401~1405

LOTTE Chemical Shanghai Co., Ltd.Rm2701, Shanghai International Trade Center,2201 West Yan An Rd, Shanghai, China. 200336Tel. +86-21-62703000-856

Page 28: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

Các tấm đá Solid Surface thương hiệu Staron được lắp đặt và bảo hành bởi LOTTE CHEMICAL. Đá Solid Surface phải

được chế tạo và lắp đặt bởi LOTTE CHEMICAL. Đá Solid Surface được lắp đặt và bảo hành theo hướng dẫn của LOTTE

CHEMICAL. LOTTE CHEMICAL sẽ sửa chữa hoặc thay thế miễn phí các sản phẩm Staron nếu sản phẩm bị lỗi do lỗi sản

xuất trong mười (10) năm đầu tiên sau ngày lắp đặt. Điều này bao gồm chi phí thực tế cần thiết để sửa chữa hoặc

thay thế sản phẩm. Mặc dù LOTTE CHEMICAL sẽ nỗ lực hết sức để sửa chữa hoặc thay thế bằng màu phù hợp nhất

với màu gốc nhất có thể, nhưng LOTTE CHEMICAL không thể đảm bảo màu chính xác trong trường hợp sửa chữa

hoặc thay thế. Nếu khách hàng có yêu cầu bảo hành các sản phẩm Staron, xin liên hệ với đại lý Staron gần nhất, tại

đó bạn sẽ được hướng dẫn cách điền form và những lưu ý cần thiết hoặc liên hệ trực tiếp với LOTTE CHEMICAL.

Bảo hành này có thể được chuyển nhượng trong thời gian 10 năm sau ngày cài đặt ban đầu chỉ khi chủ sở hữu thông

báo bằng văn bản LOTTE CHEMICAL.

Bảo hành này không bao gồm những điều sau đây:

01. Các vấn đề nhỏ như vết bẩn, vết trầy xước, đốm nước và cháy xém.

02. Không tuân thủ hướng dẫn chế tạo, lắp đặt, chăm sóc, bảo trì, vv … của Lotte Chemical Corp

03. Sản phẩm bị di chuyển khỏi vị trí cài đặt ban đầu của chúng

04. Đường chỉ xuất hiện ở bất kỳ mối nối, khe rãnh hoặc các tiếp diện phụ khác của sản phẩm

05. Sự khác biệt màu với mẫu xem trước

06. Sự khác biệt màu sắc giữa các lô hàng khác nhau

07. Màu sắc chính xác phù hợp do việc thay thế hoặc sửa chữa sản phẩm sẽ không được đảm bảo

08. Thiệt hại do sự tác động từ công trình hạng mục khác

09. Sử dụng, lạm dụng (bao gồm cả thiệt hại do va chạm và tiếp xúc với thuốc thử hóa học không được sử

dụng với sản phẩm này)

10. Chế tạo, lắp đặt, xử lý hoặc bảo trì không đúng cách

11. Các thiệt hại gây ra bởi nhiệt độ quá cao; hoặc bằng một hành động bất khả kháng

12. Tay nghề của Người gia công hoặc Trình độ lắp đặt 13. Thiệt hại từ các lỗi khác ngoài sản xuất

14. Bất kỳ sản phẩm nào được lắp đặt ngoài trời, nhà bếp, bề mặt để nướng BBQ hoặc để sưởi ấm các khu

vực như phòng xông hơi, phòng tắm hơi và bệ tắm, bồn tắm

15. Các sản phẩm trong thùng carton bao gồm các thành phần được làm từ Staron Solid Surfaces

16. Bất kỳ sản phẩm nào được lắp đặt trong xe thùng

17. Bất kỳ Sản phẩm nào được chế tạo và lắp đặt trong các ứng dụng thương mại

18. Chế tạo, lắp đặt, sửa đổi hoặc sửa chữa được thực hiện bởi các hãng lắp đặt khác

19. Màu sắc và các đường vân sẽ thay đổi theo từng tấm đá (sự sai lệch do bất cẩn trong lắp đặt vân đá)

CHÍNH SÁCH BẢO HÀNH 10 NĂM CỦA STARON

Page 29: O R TA S O T 02 T es trpo N 03 C hứngc ỉG reengua d  04 C … · 2020-03-24 · STARON SOLID SURFACE Staron is a solid surface brand of Lotte Advanced Materials from Korea

Trong phạm vi giới hạn bảo hành của tài liệu này, LOTTE CHEMICAL không bảo hành, cho các trường hợp rõ ràng hay

ngụ ý đối với Sản phẩm, bao gồm nhưng không giới hạn, bất kỳ bảo hành nào về tính thương mại hoặc phù hợp cho

một mục đích cụ thể nào hoặc tất cả các bảo hành có tính chất tương tự sẽ bị từ chối rõ ràng bởi LOTTE CHEMICAL.

LOTTE CHEMICAL không đảm bảo rằng sản phẩm sẽ đáp ứng các yêu cầu của người dùng cuối.

LOTTE CHEMICAL sẽ không chịu trách nhiệm cho bất cứ sự cố/ hậu quả gián tiếp/ hậu quả đặc biệt/ trừng phạt hoặc

thiệt hại dưới bất kỳ hình thức nào liên quan đến việc mất thiện chí, phương hại đến lợi nhuận/ việc kinh doanh bị

mất hoặc thiệt hại kinh tế gián tiếp khác. Kể cả những hư hại đối với tài sản dù cho yêu cầu đó dựa trên hợp đồng.

Do sự sơ suất, thiếu trách nhiệm (bao gồm cả trách nhiệm pháp lý) hay nói cách khác bất kỳ vi phạm nào đến cách

thức bảo hành đều bị từ chối dù cho trong thực tế những sự thiệt hại đó đã được dự báo trước.

Một số quốc gia và vùng lãnh thổ không chấp nhận những giới hạn và loại trừ trên. do đó những giới hạn và loại trừ

trên có thể không được áp dụng. giới hạn bảo hành này gửi đến bạn những chỉ dẫn cụ thể hợp pháp. bạn cũng có

thể có những chỉ dẫn hợp lý khác mà những chỉ dẫn này phù hợp trên diện rộng được chấp nhận bởi nhiều quốc gia,

nhiều tỉnh thành.

Dịch vụ bảo hành:

Để yêu cầu dịch vụ bảo hành, liên hệ với nhà sản xuất/lắp đặt ban đầu của bạn. Bạn phải xuất trình hóa đơn bán hàng

ban đầu hoặc xuất trình bằng chứng mua và lắp đặt STARON Solid Surfaces, chứng minh rõ ràng thể hiện đã mua sản

phẩm và ngày lắp đặt, để có được dịch vụ theo bảo hành này.

Để biết thêm thông tin chi tiết, xin liên hệ:

LOTTE Chemical Deutschland GMBH KölnerStr. 12 65760 Eschborn, Germany TEL+49 6196 77 272 75 LOTTE Chemical Thailand Co., Ltd. 16th Floor, Empire Tower, Unit 1602-1603, 1 South SathornRD, Yannawa, Bangkok, Thailand. 10120 Tel. +66-2-624-6737 LOTTE Chemical Deutschland GMBH-REPRESENTATIVE OFFICE (DUBAI) Office No 1702, Arenco Tower, Media City, Dubai, UAE. POBOX 48969 [email protected] Tel. +971-4-245-1401~1405

LOTTE Chemical Shanghai Co., Ltd. Rm2701, Shanghai International Trade Center, 2201 West Yan An Rd, Shanghai, China. 200336 Tel. +86-21-62703000-856 CÔNG TY TNHH SAMSUNG INTERIOR TP.HCM: 19W Nguyễn Hữu Cảnh, P.19, Quận Bình Thạnh HÀ NỘI: 166 Nguyễn Xiển, Quận Thanh Xuân HOTLINE: 028 3 7447 333 - 090 2580 097

Bảo hành này không sửa, đổi đổi bằng bất kỳ cách nào, ngoại trừ khi có văn bản thông báo chính thức có chữ ký của

một đại diện được ủy quyền của Lotte Chemical Corp.

CHÍNH SÁCH BẢO HÀNH 10 NĂM CỦA STARON