    High Frequency X-Ray Technology

    Precis ion Performance Power

  • 8/9/2019 ODYSSEY HF Series Generator Brochure

    2/6

    The ODYSSEY HFSeriesTMintegrates revolutionary design with superb functionality,resulting in the most advanced radiographic generator ever developed.

    Designed for both digital and conventional imaging and operating at a near-constant

    potential of up to 120 kHz. The ODYSSEY HFSeriesTM

    provides ULTRA HighFrequency imaging for highly efficient X-ray production. Radiographic imaging isoptimized through the ODYSSEY HFs simple programmability, which permits a

    wide variety of routine, specialized and custom procedures.

    ULTRA HIGH FREQUENCY TECHNOLOGY ...120 kHzThrough the integration of the ODYSSEY HFs sophisticatedproprietary technology, hospitals and high-volume radiologyfacilities can meet the traditional objectives of imaging.The ODYSSEY HFSeriesTMmaximizes operating efficiencyand enhances patient throughput.

    Utilization of advanced transformer design technology has enabled theemergence of ULTRA-High Frequency power. Precise voltage controland extremely efficient high voltage switching come together to providesuperb accuracy, repeatability, and system reliability.

    With a near-constant potential output of up to 120 kHz of power, theODYSSEY HF delivers highly refined images and provides the shortestexposure times, while minimizing patient dose.

    The ODYSSEY HFSeriesTMof generators provide power levels of 80 kWthrough 32 kW and outputs of up to 150 kVp, meeting the needs of anyimaging environment.

    TYPICAL KVP OUTPUT WAVEFORM

    10KVP/DIVISION

    2 MSEC / DIVISION

    HIGHER MR/MAS

    SHORTER

    EXPOSURE TIMES

    REDUCED PATIENTDOSE

    LONGER TUBE LIFE

    SUPERIOR IMAGINGQUALITY

    kVp = 100mA = 650time = 10 msec

    OPERATOR CONTROL PANELThe ODYSSEY HF Series sophisticatedoperator control panel utilizes a highesolution LCD window.

    This menu-driven display is simple to use,nd allows the operator to focus on patient

    needs. In addition, time and date arelways displayed for operator convenience.

  • 8/9/2019 ODYSSEY HF Series Generator Brochure

    3/6

    ANATOMICAL PROGRAMED RADIOGRAPHY (APR)The APR mode allows the operator to simply select the desiredexamination from any of the 100 exam views, covering the 10 anatomical

    regions. APR mode will automatically select and set the typical techniquefactors including: kVp, mA, time (mAs), focal spot, film speed, SID andimaging receptor, while allowing the operator complete control to modifyany parameter prior to exam. The operator may also input the actual patient thickness (in individual cms), thus providing the optimalselection of technique parameters for that exam. Each individual exam provides up to 50 different technique selections, for up to 5000unique anatomical program settings.

    GENERATOR OPERATING MODESThe ODYSSEY HFSeriesTMprovides a wide selection of operating modes(3 point, 2 point or 1 point) providing different levels of user intervention.Technologists may assign their own custom selected techniques or maychoose varying levels of automated control (APR) for precise imagingparameters. In all operating modes, the user always has the capability tooverride any technique parameter individually, providing uncompromisedflexibility and control.

    APR/AEC MODEWhen used in conjunction with AEC (Automatic ExposureControl), the APR mode enhances uniformity of images, virtuallyeliminating the need for retakes. It automatically selects the required

    AEC chamber field format, sets a back-up time and terminates theexposure at the precise interval required for a perfect image.

    APR/PATIENT TYPE MODEWhen APR is used without AEC, the system allows theoperator to quickly modify the mAs (time) to accommodatfor various patient densities. This mode provides quickautomatic adjustment of mAs in increments of +/- 25%and +/- 50%, from the average patient type.

    SELECT ANATOMICAL REGION.

    STEP - 1

    In addition, the MAS/ TIMEbutton enables you to togglebetween viewing either MASor SEC (time).

    MANUAL MODEManual mode allows the operator to easily select all techniqueparameters (mA, kVp, mAs/time).

    AUTOMATIC EXPOSURE CONTROL (AEC) MODEThe AEC mode providesexceptional uniformity andimage consistency.

    AEC automatically terminatesthe exposure at the precisemAs required. To allow theoperator full control, there is

    an 11-step selection of AEC density (in 15% increments). The systemalso provides a selection of up to seven different film speed settings.

    Precision Perf

  • 8/9/2019 ODYSSEY HF Series Generator Brochure

    4/6

    TECHNOLOGICALLY SUPERIOR BY DESIGN...The ODYSSEY HFSeriesTMof generators incorporate the latest inadvanced electronic design and software architecture, including:

    Self-Testing/Self-Diagnostic X-Ray Tube Protection Circuit Exposure Counter/X-Ray Tube Counter Anode Heat Unit Calculator/Monitor

    Error Messaging Multiple Security Code Feature Automatic Line Voltage Compensation APR Technique and Text Editing International Language Ability Auto Calibrate Function Extensive Memory for History Details RS-232 Connection Port Automatic shut-off timer

    (variable time settings) Connect to Techvision remote control

    READY FOR EXPOSURE.

    STEP - 3

    SELECT ANATOMICAL VIEW.

    STEP - 2

    rmance Power

    Q-WARETMUTILITY SOFTWAREQ-WARETMis a laptop-based service support tool thatprovides an advanced level of APR text and technique editing,simplified calibration as well as other set-up functions.

    ation

    tails

    tro

    ort tool thatd technique editing,p functions.

    SELF-DIAGNOSTICSThe ODYSSEY HFs integrated self-diagnostics andcalibration program surveys system performance at therate of 500 times per second. This specialized qualitycontrol program is designed to detect operator andsystem errors for enhanced operation.

  • 8/9/2019 ODYSSEY HF Series Generator Brochure

    5/6

    Quantum Q-Rad Systems are the ideal choice forbusy imaging center, orthopedic facility or hospThe advanced features and unique design aspects osystem allow the technologist to fully concentrate opatient during the examination.

    Q-RadSystems

    Upgrade To Digital RadiographQUANTUM:LEADING THE WAY IN

    DIGITAL IMAGINGQuantums Q-Rad-DIGITAL:DRX-Series" are fully integratedDigital Radiographic Systems, featuringCarestream DRX technology.

    mart-System innovations; such asTechVision, Operator Touch-ControlCenter, and the flexibility of Wirelessr Wired DR solutions are availablen either Ceiling or Floor mountedonfigurations.

    All systems provide advanced operationalnd ergonomic features, with virtuallynlimited positioning capabilities.

    Speed With PrecisionDigital detector technology allowsmages to be previewed within secondsfter the exposure. The results can beutomatically sent to other viewingtations, printers and archive servers

    n the facilities network.

    *All Quantum Radiographic Systemsare fully upgradable to integrated DR technology,providing for a very secure investment.

    DRX SERIES

  • 8/9/2019 ODYSSEY HF Series Generator Brochure

    6/6

    Generator Specifications

    STORED ENERGY (SE) GENERATORSQuantums advanced STORED ENERGY (SE)technology permits powerful operation using

    only a standard low amperage wall outlet oralternate power source. The SEs power cells arevirtually maintenance-free and provide years ofusage. These units are ideal in facilities whereincoming power is unavailable and for mobileimaging applications.

    Quantum Medical Imaging | Division of Carest2002 Orville Drive N

    Ronkonkoma, NY 11779Tel (631) 567-Fax (631) 567-

    www.quantummedic2013 Quantum Medical Imaging | Division of Carestream/n: QMI-Odyssey (07/13)

    12.25"(311mm)

    17.91" (455mm)

    ODYSSEY HFSeriesTM

    GENERATOR OPTIONS:Automatic Exposure Control (AEC) Electronics: (QG-AEC)High (Dual) Speed Starter: (Q-HSS); internal designPedestal Mount for Operator Control Console: (QG-PDL)Wall Mount for Operator Control Console: (QG-WM)Remote Exposure Hand Switch: (R80-HS)Digital Imaging Interface: (QG-DIG); consult factory

    STORED ENERGY (SE) GENERATORS

    Model # QG-80 QG-65 QG-50

    QG-50-2

    QG-40

    QG-40-2

    QG-40-3

    QG-32

    QG-32-2

    QG-32-3

    QG-50-SE QG-40-SE QG-32-SE

    Catalog # QG-8000 QG-6500 QG-5000

    QG-5000-2

    QG-4000

    QG-4000-2

    QG-4000-3

    QG-3200

    QG-3200-2

    QG-3200-3

    QG-5000-SE QG-4000-SE QG-3200-S

    Power Rating (kW):DIN 80 kW 65 kW 50kW 40kW 32kW 50kW 40kW 32kW

    ULTRA High Frequency 120 kHz PLUS 120 kHz PLUS 120 kHz PLUS 120 kHz PLUS 120 kHz PLUS 120 kHz PLUS 120 kHz PLUS 120 kHz PL

    kVp Range (1 kVp steps) 40 - 150 kVp 40 - 150 kVp 40 - 125 kVp 40 - 125 kVp 40 - 125 kVp 40 - 125 kVp 40 - 125 kVp 40 - 125 kV

    40-150 kVp output standard standard option option option n/a n/a n/a

    mA Range 25 - 800 mA 25 - 800 mA 25 - 630 mA 25 - 500 mA 25 - 500 mA 25 - 600 mA 25 - 500 mA 25 - 400 m

    Timer Range

    (seconds)0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3 sec. 0.001 - 6.3

    mAs Range 0.1 - 800 mAs 0.1 - 800 mAs 0.1 - 800 mAs 0.1 - 600 mAs 0.1 - 600 mAs 0.1 - 500 mAs 0.1 - 500 mAs 0.1 - 400 m

    APR Programs

    (Pre-programmed and Custom)

    100 APR Views

    (5000 Techniques)

    100 APR Views

    (5000 Techniques)

    100 APR Views

    (5000 Techniques)

    100 APR Views

    (5000 Techniques)

    100 APR Views

    (5000 Techniques)

    100 APR Views

    (5000 Techniques)

    100 APR Views

    (5000 Techniques)

    100 APR View

    (5000 Techniqu

    Operational Modes

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option)

    4. APR/Patient Type

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option)

    4. APR/Patient Type

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option)

    4. APR/Patient Type

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option)

    4. APR/Patient Type

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option)

    4. APR/Patient Type

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option)

    4. APR/Patient Type

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option)

    4. APR/Patient Type

    1. kVp/mA/time

    2. kVp/mAs

    3.kVp with AEC (option

    4. APR/Patient Ty

    Input Line: 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz) 50/60 Hz 50/60 Hz 50/60 Hz

    Single Phase Line:

    208-260 VAC; +/- 5%n/a n/a n/a Standard Standard

    All STORED ENERGY (SE) GENERATORS

    require a standard power input (50/60 Hz) of either

    105-130 VAC, 10 Amp +/- 10% or

    220-240 VAC, 10 Amp +/- 10%

    **Three Phase Line: -3

    380-480 VAC; +/-10%Standard Standard Standard Option Option

    Three Phase Line: -2

    208 VAC; +/- 5%n/a n/a Option Option Option

    Output power ranges may be limited by x-ray tube selection/AEC limits/incoming power line.**High (Dual) Speed Starter (Only Available with the Three Phase Line: -3 380 - 480 VAC; +/-10%)

    Specifications subject to change without prior n

    20.66"(525mm)*

    24" (610mm)

    1(432

    34.72"(882mm)

    * Recommend 3" (76mm)clearance from wall for cabli

    36.5"(927mm)

    The Odyssey HFs control panel can be positioned on a custom pedestal, fastened to awall for space saving, desktop mounted, or positioned on top of the generator cabinet.

    3.13"(79.5mm)

    11.29"(287mm)

    6.5"(165mm)