orion telecom networks inc. - 2007slide 1 vcl100mc-16 updated : january, 2007 vcl100mc-16 next...
TRANSCRIPT
Orion Telecom Networks Inc. - 2007 Slide 1
VCL100MC-16 VCL100MC-16
Updated : January, 2007
VCL100MC-16VCL100MC-16Next GenerationNext Generation
STM-1/4/16 PlatformSTM-1/4/16 Platform16810, Avenue of Fountains, Suite # 108,
Fountain Hills, AZ 85268, U.S.A.
Phone: +1 (480) 816-8672Fax: +1 (480) 816-0115
E-mail: [email protected] Site: http://www.oriontelecom.com
Orion Telecom Networks Inc. - 2007 Slide 2
VCL100MC-16 VCL100MC-16
VCL100MC-16 Next generation STM-1/4/16 Platform Extensive Support for Data traffic
• FE & GigE transport over VC12s/VC3s/VC4s • Ethernet Switching/VLAN switching
High Density Platform• 567xE1 from a single chassis• 8 STM-1 rings subtended from 1 STM-16 ADM• 2 STM-4 rings subtended from 1 STM-16 ADM
High capacity• 7.5Gig fully non blocking XC at VC12 granularity
Managed by the same NMS as other VCL100 platforms (VCL-NMS)
Orion Telecom Networks Inc. - 2007 Slide 3
VCL100MC-16 VCL100MC-16
VCL100MC-16: Line Diagram
1
P
S
M
4
T
R
I
B
5
T
R
I
B
6
T
R
I
B
7
A
G
G
8
X
C
C
9
X
C
C
10
A
G
G
11
T
R
I
B
12
T
R
I
B
13
T
R
I
B
14
T
R
I
B
15
P
S
M
2
T
R
I
B
3
T
R
I
B
17 FAN
16 MFC
Orion Telecom Networks Inc. - 2007 Slide 4
VCL100MC-16 VCL100MC-16
XCC provides following functionalities• Cross Connect matrix
Fully non-blocking VC-12/VC-3/VC-4 7.5Gig (48x48 STM-1/OC-3 equivalent) 12.5Gig (80x80 STM-1/OC-3 equivalent) will be available in future Unidirectional, Bidirectional, Multicast and Broadcast
• Control Sub-system Architected to support dense cross connect configurations High processing capability to handle control plane loads in large DXC locations
• Can handle multiple subtended rings
• Timing Sub-system Timing can be derived from
• External inputs – 2MHz or 2Mbps• STM-1/4/16 or OC-3/12/48 and E1 Interfaces• Internal Stratum-3 clock
SSM support on S1 byte
Common Modules:Cross Connect and Controller Card (XCC)
Orion Telecom Networks Inc. - 2007 Slide 5
VCL100MC-16 VCL100MC-16
PSM: takes - 48 V DC as input and provides - 5 V & - 12 V DC to other subsystems. It has the following features:
• - 36 V DC to - 60 V DC operation
• Reverse Polarity protection
• Automatic shutdown when power exceeds - 60 V or falls below -36 V
• No impact on operation for power interruption < 4ms
• Inrush limiting as per ETSI EN 300 132-2
• Redundancy of Power Supply
• Fuse protection in case of overloads/failures.
Power Supply Module
Orion Telecom Networks Inc. - 2007 Slide 6
VCL100MC-16 VCL100MC-16
MFC – provides the following:
• NMS (10/100Base-Tx)
• Craft (RS-232)
• F1 user channel and Modem interface (RS232)
• Engineering OrderWire
• Audio-visual indication of alarms through Hooter and LEDs
• Seven External Alarm inputs and four Potential free contacts for alarm outputs
Multi-function Card (MFC)
Orion Telecom Networks Inc. - 2007 Slide 7
VCL100MC-16 VCL100MC-16
Traffic Modules Optical Cards:
• 1xSTM-16• SFP Based
• 2xSTM-4 / 8xSTM-1 card SFP Based. Individual STM-1/4 ports can use different SFPs A contiguous block of four STM-1s can be upgraded to a single STM-4 Mix and match STM-1 o/e up to one STM-16
Data Cards:• 8x10/100BaseT Ethernet Transport Card ( STM-1 backhaul)• 4x10/100BaseT and 4 x 100BaseFX Ethernet Transport Card ( STM-1 • backhaul)• 2xGigabit Ethernet Transport Card (STM8 backhaul)• 8xFE + 2xGigE Ethernet Switching Card (STM4 backhaul)• 8xFE + 2xGigE Ethernet Switching Card (STM8 backhaul)*
PDH Cards:• 63xE1• 3xE3/DS3
Orion Telecom Networks Inc. - 2007 Slide 8
VCL100MC-16 VCL100MC-16
Higher Tributary Density:• VCL100MC-16 can drop up to 567xE1s from the • chassis using 63xE1s tributary cards
Subtended Rings: • VCL100MC-16 can function as a stand-alone cross connect subtending
8xSTM-1/OC-3 rings OR 2xSTM-4/OC-12 rings OR And 1xSTM-16/OC-48 rings
All configurations with full VC-12/VT1.5 cross connects possible between the
rings
Hardware Features
2xSTM-4/OC-12 rings
STM-1/OC-
3 Ring
Orion Telecom Networks Inc. - 2007 Slide 9
VCL100MC-16 VCL100MC-16
VCL100MC-16 Bandwidth Distribution
7.5G XC• Slot 6 and 11 are serial slots with
maximum uplink of STM-8 each• Slots 2-5 and 12-14 are parallel slots
with maximum uplink of STM-1 each• Total uplink from all tributary slots
(slots 2-6 and slots 11-14) can be STM-16
12.5G XC (in future)• Slots 2-5 and 13-14 can be serial
slots with maximum uplink of STM-4 each and slots 6,11,12 can be serial slots with maximum uplink of STM-8 each
• All trib slots can be parallel slots with maximum uplink of STM-1 each
• Total uplink from all tributary (slots 2-6 and slots 11-14) can be 3 x STM-16
Slot No.
Bandwidth Distribution for
12.5G XC Type of SlotSlot-2 1 0 4 TributarySlot-3 1 0 4 TributarySlot-4 1 0 4 TributarySlot-5 1 0 4 TributarySlot-6 4 8 8 TributarySlot-7 16 16 16 AggregateSlot-10 16 16 16 AggregateSlot-11 4 8 8 TributarySlot-12 1 0 8 TributarySlot-13 1 0 4 TributarySlot-14 1 0 4 Tributary
Bandwidth Distribution for
7.5G XC
Orion Telecom Networks Inc. - 2007 Slide 10
VCL100MC-16 VCL100MC-16
VCL100MC-16: Application Diagram
STM-16
STM-1 Ring
STM-1 Ring
STM-4Ring
Ethernet Services for Corporate Customers•Ethernet Private Line•Ethernet Virtual Private Line•Ethernet LAN
BTSEPABX
VCL100MC-16VCL100MC-16
VCL100MC-16
10/100 Base-T FE, GE
BTS
VCL100MC-16
Drop up to 567 E1/DS1 forWireline and Wireless Backhaul
VCL100MC-16
FE, GE
DSLAMAggregation
10/100 MbpsEthernet
Orion Telecom Networks Inc. - 2007 Slide 11
VCL100MC-16 VCL100MC-16
Network Protection
Support for all standard and emerging network
protection features such as • 1+1 MSP
• SNCP
• 2F MS-SPRing
• LCAS Protection for Ethernet
• RSTP Protection with Ethernet switching.
Orion Telecom Networks Inc. - 2007 Slide 12
VCL100MC-16 VCL100MC-16
Equipment Protection
VCL100MC-16 can offer redundancy to: • Power Supply Module (PSM)
• 1+1 hot standby and load-sharing modes
• Cross Connect (XCC)
• Control Sub-system
• Integrated within the Cross Connect (XCC)
Optical Cards (Using MSP or SNCP)
Timing sub-system & Interfaces
Orion Telecom Networks Inc. - 2007 Slide 13
VCL100MC-16 VCL100MC-16
Multi-service Support Supports FE & GigE Interfaces and Layer 2 switching
Complies to the latest ITU-T Recommendations on transport of EoS
• G.7041 (GFP)
• G.7042 (LCAS)
• G.707 (Virtual Concatenation) 10/100BaseT interfaces can be mapped to both LO (VC-12/VT1.5) and HO (VC-3/STS-1 and VC-4/STS-3) virtual containers
Gigabit Ethernet traffic is mapped to HO virtual containers
Layer 2 Switching complies to IEEE 802 standards
• IEEE 802.1D (Bridging)
• IEEE 802.1Q (VLAN) Also IEEE 802.1p (priority)
• IEEE 802.3x (Flow Control)
• IEEE 802.1w (Rapid STP), 802.1s (Multiple STP)
• IEEE 802.3ad (link aggregation)
• IEEE 802.1ag (Connectivity fault management)
• MEF 9 & MEF 14
Orion Telecom Networks Inc. - 2007 Slide 14
VCL100MC-16 VCL100MC-16
Software Features
Software intelligence is a key differentiator of VCL100MC-16 as also of all other VCL100 platforms
Some advanced features which are typically associated with high-end DWDM platforms are provided on VCL100MC-16• Auto topology discovery
G.7714
• Customer Network Management Provision for the customer to self-provision circuits over his part of the VCL100
network using standard web browser interfaces
• Northbound SNMP ensures seamless integration with third party EMS
Orion Telecom Networks Inc. - 2007 Slide 15
VCL100MC-16 VCL100MC-16
Management Connectivity
VCL100MC-16 has a wide range of management options to effectively inter-operate with other vendor equipments in mixed deployment scenarios.• DCC-R • DCC-M
• F2/F3 bytes
• E1/VC12 management channel
• Dial-in using modem port
• Ethernet Management.
DCC transparency• DCC-R, DCC-M, F1, F2/F3 can be passed through, permitting third party
nodes to co-exist in the same ring.
Orion Telecom Networks Inc. - 2007 Slide 16
VCL100MC-16 VCL100MC-16
Sweet-Spots for VCL100MC-16
Optimized for a variety of stand-alone ring Point-of-Interconnect (PoI) applications• Consolidation of the PoI infrastructure by integrating
Multi-rate Optical Interfaces (STM-1/4/16)
Can be positioned as a versatile gateway element
• Support for SDH interfaces
• Support for both AU3 and AU4 mapping modes
ADM applications with subtending rings
• Each ring can be protected using a different protection scheme Say, SNCP on one ring, MS-SPRing on another
• Support for large E1,E3/DS3 traffic add-drops
Wave feeder for DWDM networks due to support for 15xx nm interfaces
Orion Telecom Networks Inc. - 2007 Slide 17
VCL100MC-16 VCL100MC-16
Thank you for your attentionThank you for your attention
For more details visit us at our Website at
http://www.oriontelecom.com
16810, Avenue of Fountains, Suite # 108,Fountain Hills, AZ 85268, U.S.A.
Phone: +1 (480) 816-8672Fax: +1 (480) 816-0115
E-mail: [email protected] Site: http://www.oriontelecom.com