IN THE WORLD OF PARTICLES PAMAS COUNTS PAMAS AS3 Autosampler for fully automated Oil Contamination Analysis Fully automated Particle Analysing System for unattended batch sampling of several hundred samples per day Application: Contamination analysis of a continuously high number of oil samples • Fully automated analysis Up to 200 samples within 8 hours (i.e. up to 600 samples per day in case of conti- nuous operation Data transfer in universal file format (.xml) Handling viscosities up to 200 cStokes Excellent reproducibility Free programmable time saving flushing cycles Automatic preparation and filtration of flushing liquid Adaptable to any application High resolution sensor with 4 µm(c) sensitivity according to ISO 11171 Automated ultrasonic sample preparation before measurement integrated automatic dilution device REV 09/2018

Upload: others

Post on 19-Jul-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PAMAS AS3 Autosampler for fully automated Oil ... · PAMAS AS3 Autosampling system for almost every application The fully automated PAMAS AS3 autosampling system ana-lyses high quantities

In the world of partIcles pamas counts

PAMAS AS3Autosampler for fully automated Oil Contamination Analysis

Fully automated Particle Analysing System for unattended batch sampling of several hundred samples per day

Application:

Contamination analysis of a continuously high number of oil samples • Fullyautomatedanalysis

� Up to 200 samples within 8 hours (i.e.upto600samplesperdayincaseofconti-nuous operation

� Data transfer in universal file format (.xml)

� Handlingviscositiesupto200cStokes

� Excellentreproducibility

� Freeprogrammabletimesavingflushingcycles

� Automaticpreparationand filtrationofflushingliquid

� Adaptabletoanyapplication

� High resolution sensor with 4 µm(c) sensitivity accordingtoISO11171

� Automatedultrasonicsample preparation before measurement

� integratedautomaticdilutiondevice

REV09/2018

Page 2: PAMAS AS3 Autosampler for fully automated Oil ... · PAMAS AS3 Autosampling system for almost every application The fully automated PAMAS AS3 autosampling system ana-lyses high quantities

PAMAS HEAD OFFICEDieselstraße10,D-71277Rutesheim,Phone:+49715299630,Fax:+4971529963-32,Email:[email protected] USA1408SouthDenverAvenue,Tulsa,OK74119USA,Phone:+19187436762,Fax:+19187436917,Email:[email protected] BEnElUxMechelenCampus,Schaliënhoevedreef20T,B-2800Mechelen,Phone:+3215282010,Mobile:+32477424862,Email:[email protected] FrAnCERouteduTailleur210/136,F-40170Saint-Julien-en-Born,Mobile+33625332041,Email:[email protected] PAMAS lATIn AMErICACuritiba-Paraná,Brazil,Phone/Fax:+554130225445,Mobile:+5541999722173,Email:[email protected] InDIANo.203,Ifloor,OxfordHouse,#15RustamBaghMainRoad,Bangalore560017,India,Phone:+918041150039,Email:[email protected] HISPAnIACalleZubilletaNo.131°B,ES-48991Algorta,Mobile:+34677539699,Email:[email protected] PAMAS UKSci-TechDaresbury,KeckwickLane,Daresbury,CheshireWA44FS,Mobile:+447917713366,Email:[email protected]

®Registeredtrademarksarepropertiesoftheirindividualowners.Allspecificationsaresubjecttochangewithoutnotice.

P l e a s e v i s i t o u r w e b s i t e a t w w w . p a m a s . d e

PAMAS AS3 Autosampling systemfor almost every applicationThefullyautomatedPAMAS AS3 autosampling system ana-lyseshighquantitiesofsamples.Thisnewsystemisdesignedtoprovidesampleanalysisofseveralhundredsamplesperday,withunattendedoperation.Thesystemoffersamultitudeoffea-turesregardingsampleprepara-tion,samplehandling,flushingandsampledilution.

Sample preparationThePAMAS AS3 system inclu-desasamplepreparationprobethatbreaksallagglomeratesinthefluidbeforeanalysis.Theultrasonic probe prepares the subsequentsamplewhilstthecurrentsampleisbeinganalysed.Thesamplepreparationdeviceiscleanedbetweensamplestominimise cross contamination.Sample handlingThenewsystemhasaXYZstage,operating with samples on trays asthesearethemostwidelyusedmethodinhighquantitylabo-ratories.RFID(RadioFrequencyIdentification)orbarcodesystemscanbeusedoptionallytoauto-maticallyidentifythetrays.Thesystemisservomotordriven.Thisincreasesthespeedofoperationandreducesthenoiselevelbelowthat of stepper motors.

Seamless integration to lIM systemThesystemcanbelinkedtoanexistingLIM(LaboratoryInforma-tionManagement)system.IftheexistingLIMsystemcanforwardsampleIDsbasedontraynumberandx/ypositionwithinthetray,noindividualsampleidentificati-onprocedureisnecessary.IfthesamplescarryRFIDorbarcodelabels,samplescanbeidentifiedwithanattachedreader(optio-nal). AcloselinktotheLIMsystemhelpstorequestinformationaboutsamples.ItispossibletotransferspecialconditionoptionsforsamplesusingtheLIMsystem.

FlushingThePAMASAS3autosamplingsystemisequippedwithanintel-ligentflushingdevicewhichopti-mizesthesequenceofsamples.

Technical data

Particle counter: � Particlecountsin8channels � 32-bithighperformanceCPUwith sophisticatedprogrammabledigital domainsignalconditioningand 4096 internal channels Datatransfer:8bitASCIIcode throughRS232port(57600baud)Powersupplyviaalternatingcurrent(110V,115V,220V,240Vor50-60Hz)

Volumetric Sensor PAMAS HCB-lD-50/50:Calibrationrange:4-70μm(c)accordingtoISO11171

Software: � TheAutosamplingsoftwareisindivi-duallydevelopedforthecustomer‘sspecificapplicationandthuscanbespecifiallyadaptedtoindividuallabo-ratoryinfrastructuresandtoexistingLIMsystems.

� Withtheaidofthesoftware,thePAMASAS3Autosamplerreportsmeasuring results in full compliance withcommoncleanlinessstandardsincludinge.g.ISO4406,NAS1638andSAEAS4059.

Sample bottle volume: upto250ml

Viscosity: upto200cSt relative humidity:0-95%,noncondensing Size:varioussizemodelsavailable,e.g.195cmx114cmx182cm

Weight:268kg

Sample dilution Somesamplesmayeitherbetoodirtyortooviscousormaycontainundissolvedadditivesorundissolvedwater.Inthiscase,sampledilutionwithlowviscoussolvents helps to get reliable measuringresults.Thenewsystemhasanautomaticdilutionsystemthataddsaprogrammab-le amount of solvent online to the raw sample.

OptionsThePAMAS AS3 autosampling system can be built to match existingtrays.Largesystemswithseveralhundredsamplestoanaly-se,allowcontinuousunattendedoperation (three shifts within 24 hours).Thesystemoptionallycanbeequippedwithanintegrateddraintrapthatcollectsanyspil-lage.Adrainagesystemcanbeconnectedtofeedthespillagetoa central collection system.