philips instantfit led pl-c/t lamp - · pdf filethe philips instantfit led pl-c/t lamp is a...
TRANSCRIPT
Philips InstantFit LED PL-C/T Lamp
The Philips InstantFit LED PL-C/T lamp is a technology breakthrough out of our LED lamps portfolio. This product is compatible with programmed start ballasts and is the easiest way to replace fluorescent PL-C/T with LED solutions. The InstantFit lamp is a true plug-and-play LED solution that realizes an energy savings of up to 60%.
3
Compatibility
• Innovative driver design that enables a “plug-and-play” LED
solution to replace existing fluorescent lamps
• Quick and easy installation
Reliability
• Reliable operation between -20 oC and 45 oC ambient
temperature
• Tested to F50L70 requirements, rated life time is 40,000 hrs.
This is defined as the number of hours when 50% of a large
group of identical lamps drops below 70% of its initial lumens
• 50,000 switching cycles
User Comfort
• CRI 82
• Advanced optical design ensures a uniform light output and
superior optical efficiency
Energy Savings
• Energy savings of up to 60%*
Safety
• Over voltage and over temperature protection.
• Complies with UL and CSA safety requirements.
• Shatterproof polycarbonate (PC) material.
Environment
• No Mercury.
• Low Carbon Footprint.
Product Features
* Based on comparison between 2-lamp 8.5W InstantFit LED
PL-C/T (system power = 21W) vs. 2-lamp 26W PL-C System
(system power =52W), both lighting systems including lamps
and reference programmed start ballasts
4
Photometric Diagrams
1 x Philips LED InstantFit PL-C/T Lamp 8.5W 2700K/3000K/3500K 1 x 900 lm
1 x Philips LED InstantFit PL-C/T Lamp 8.5W 4000K 1 x 950 lm
Spectral Power Distribution
2700K
3000K
3500K
4000K
1 x Philips LED InstantFit PL-C/T Lamp 10.5W 2700K/3000K/3500K 1 x 1200 lm
1 x Philips LED InstantFit PL-C/T Lamp 10.5W 4000K 1 x 1300 lm
5
100%
99%
98%
97%
96%
95%
94%
93%
92%
Lum
en (
%)
T c (oC)
67 72 82 8777
Operating temperature T operating min -20°C max +45°C
Storage temperature T case min -40°C max +65°C
Maximum surface temperature for rated lifetime of tube at Tamb.=25°C T case +67°C (Horizontal)
+77°C (Vertical)
Temperature
TC Point
TC Point White Side
70 0.5
Diffusion Side
Dimension: mmHorizontal
6
TC Point TC Pointin the center
106.
5 0
.5
100%
99%
98%
97%
96%
95%
94%
93%
92%
Lum
en (
%)
T c (oC)
77 82 92 9787
Dimension: mmVertical
Dimensions (mm)Product A1
8.5PL-C/T LED/26H-2700 IF 4P 10/1 163.1 147.5 128.3 33.4 33.4
8.5PL-C/T LED/26H-3000 IF 4P 10/1 163.1 147.5 128.3 33.4 33.4
8.5PL-C/T LED/26H-3500 IF 4P 10/1 163.1 147.5 128.3 33.4 33.4
8.5PL-C/T LED/26H-4000 IF 4P 10/1 163.1 147.5 128.3 33.4 33.4
B1 C1A2 A3
Dimensions (mm)Product A1
10.5PL-C/T LED/26V-2700 IF 4P 10/1 49.6 125.5 109.9 99.9 49.6
10.5PL-C/T LED/26V-3000 IF 4P 10/1 49.6 125.5 109.9 99.9 49.6
10.5PL-C/T LED/26V-3500 IF 4P 10/1 49.6 125.5 109.9 99.9 49.6
10.5PL-C/T LED/26V-4000 IF 4P 10/1 49.6 125.5 109.9 99.9 49.6
B3 C1B1 B2
The product complies with UL, NSF, RoHS, CSA.
Approbation & Certificates
A1
A2
A3 B1
C1
A1
C1 B1B3 B2
7
Technical specification
* Minimum CRI is 80.** Tested to F50L70 requirements.
Product Model Product Description Bare Lamp Average Volts Inital Base CRI * Color Rated ** BeamNumber Wattage System Lumens Temp. Average Angle Wattage Life (W) (W) (V) (Lm) (K) (Hrs) ( o )
458364 9290011807 8.5PL-C/T LED/26H-2700 IF 4P 10/1 8.50 10.50 120-277 900 G24q/GX24q 82 2700 40000 120
458372 9290011808 8.5PL-C/T LED/26H-3000 IF 4P 10/1 8.50 10.50 120-277 900 G24q/GX24q 82 3000 40000 120
458380 9290011809 8.5PL-C/T LED/26H-3500 IF 4P 10/1 8.50 10.50 120-277 900 G24q/GX24q 82 3500 40000 120
458398 9290011810 8.5PL-C/T LED/26H-4000 IF 4P 10/1 8.50 10.50 120-277 950 G24q/GX24q 82 4000 40000 120
458406 9290011811 10.5PL-C/T LED/26V-2700 IF 4P 10/1 10.50 14.50 120-277 1200 G24q/GX24q 82 2700 40000 120
458414 9290011812 10.5PL-C/T LED/26V-3000 IF 4P 10/1 10.50 14.50 120-277 1200 G24q/GX24q 82 3000 40000 120
458422 9290011813 10.5PL-C/T LED/26V-3500 IF 4P 10/1 10.50 14.50 120-277 1200 G24q/GX24q 82 3500 40000 120
458430 9290011814 10.5PL-C/T LED/26V-4000 IF 4P 10/1 10.50 14.50 120-277 1300 G24q/GX24q 82 4000 40000 120
Installation Guide
Please refer to www.philips.com/instantfit for
the latest ballast compatibility guide.
5 - Horizontal 61 4a - Horizontal
4b - Vertical
2a - Horizontal 3 - Ballast Check
2b - Vertical
Wiring Diagram
BLUE
RED
BLUEBLACK
WHITELINE
GREEN
YELLOWBALLAST
RED
unded
WIRING: (2) LAMPS (1) LAMP
1. Switch off power to the luminaire. Remove diffuser (if provided).2. Remove the existing compact fluorescent lamps from the luminaire.3. Verify that the ballast installed in the luminaire is listed in the Philips compatibility guide (www.philips.com/instantfit). - Note: If the ballast is not on the compatibility guide, the ballast must be replaced with one that is listed on the compatibility guide. Please refer to the wiring diagram below.4. Install the Philips InstantFit LED lamps into the existing lamp holders and ensure that they are properly seated in the lamp holder.5. For Horizontal configuration only - Adjust the angle of the base of the lamp to direct the light towards the application. Please refer to the diagram below for rotational limits.6. Replace diffuser (if in step 1). Switch on power to the luminaire removed.
8
Application Notes
• Product is not dimmable.• Suitable for dry & damp locations.• Operating fixture ambient is -20°C and +45°C.• Always switch off power to the luminaire before commencing work.
OEM Guideline
100%90%80%70%60%50%40%30%20%10%
00 2000010000 4000030000 6000050000
Cum
ulat
e Fa
ilure
Rat
e
Hours
Failure rate vs. Lifetime @ Ta 25 OC
Horizontal
Lumen Maintenance vs. Lifetime
100%
95%
90%
85%
80%
75%
70%0 2000010000 30000 40000 50000
Lum
en M
aint
enan
ce
Hours
80%
70%
60%
50%
40%
30%
20%
10%
00 2000010000 4000030000 60000
TC=87 OC
TC=77 OC
TC=67 OC
50000
Tota
l Fai
lure
Rat
e
Hours
Failure Rate vs. Lifetime vs. Tcase
57 67 77 87
60000
50000
40000
30000
20000
10000
0
F10L70
F50L70
Life
time
TC (oC)
Lifetime vs. Tcase
100%90%80%70%60%50%40%30%20%10%
00 2000010000 4000030000 6000050000
Cum
ulat
e Fa
ilure
Rat
e
Hours
Failure rate vs. Lifetime @ Ta 25 OC
Vertical
80%
70%
60%
50%
40%
30%
20%
10%
00 2000010000 4000030000 60000
TC=97 OC
TC=87 OC
TC=77 OC
50000
Tota
l Fai
lure
Rat
e
Hours
Failure Rate vs. Lifetime vs. Tcase
© 2015 Philips LightingAll rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights.
07/2015www.philips.com
Lumen Maintenance vs. Lifetime
100%
95%
90%
85%
80%
75%
70%0 2000010000 30000 40000 50000
Lum
en M
aint
enan
ce
Hours
67 77 87 97
60000
50000
40000
30000
20000
10000
0
F10L70
F50L70
Life
time
TC (oC)
Lifetime vs. Tcase