pisd-w201c 100w dimmable power (36v output)
DESCRIPTION
PISD-W201C 100W Dimmable Power (36V Output). 36V / 2.7A / 97.2W. ▶ Mechanical Outline (Metal Case) - 228 x 68 x 38mm. Features. ▶ Suitable for LED Street Outdoor Application ▶ Universal AC input / Full Range (AC90V ~ AC305V) ▶ 0 -10 Dimming can be selected - PowerPoint PPT PresentationTRANSCRIPT
www.lginnotek.com
Datasheet is subject to change without notice.
Outdoor
Revised 21 January 2013 (REV. 4.0)
Parameter Min Typ. Max Unit Remark
Input Voltage 90 - 305 VAC
Input Current 0.3 - 1.2 A
Input Frequency 47 - 63 Hz
Power Factor 0.9 - - PF
Inrush Current - - 100 Apk Based on IEC60555
PISD-W201C100W Dimmable Power (36V Output)
Features ▶ Suitable for LED Street Outdoor Application
▶ Universal AC input / Full Range (AC90V ~ AC305V)
▶ 0 -10 Dimming can be selected
▶ Constant and Adjustable Current / Voltage Control
▶ High Efficiency (Up to 92%)
▶ High PF (> 0.9) and Low THD (< 20%)
▶ Protection : OVP, OCP, SCP and OTP
▶ Class 2, KC, UL, FCC, CE, PSE Safety Certifications Approved
Input Specifications
Critical Specifications
Output Specifications
Parameter Min Typ. Max Unit Remark
Output Voltage 27 36 37 V
Output Current 2.0 - 2.7 A
Output Dimming Current Range 10 - 100 % 0-10 Dimming
Output Current Tolerance -5 - +5 %
Output Ripple Current - - 10 %
Start-up Time - - 1000 ms
36V / 2.7A / 97.2W
1
Input Voltage
OutputVoltage
Output Current
Output Power
Efficiency THDPower Factor
90 - 305VAC 36V 2.0 - 2.7A 97.2W Up to 92% < 20% > 0.9
▶ Mechanical Outline (Metal Case) - 228 x 68 x 38mm
※ Mass Production : Feb. 2013
※ Sample Availability : Available
www.lginnotek.com
Datasheet is subject to change without notice.
Outdoor
Revised 21 January 2013 (REV. 4.0) 2
Parameter Min Typ. Max Unit Remark
Output Over Voltage Protection 40 41.5 43 V Auto Recovery
Output Over Current Protection TBD A Auto Recovery
Output Short Circuit Protection - VAC Auto Recovery
Protection Functions
Reliability Specifications
Parameter Min Typ. Max Unit Remark
Life Time- 50 - kHr @ Ta=25℃
- - - kHr @ Ta=40℃
Failure Rate - - - %
- - - %
MTBF - - - kHr
Environmental Specifications
Parameter Min Typ. Max Unit Remark
Operating Temperature -40 - 70 ℃ Ambient temp.
Storage Temperature -40 - 80 ℃ Ambient temp.
Humidity
10 - 90 %Relative humidity for opera-tion
- - 95 %Relative humidity for stor-age
Standards
Parameter Condition Remark
Safety Standards
- KC - UL 8750, UL 1310, C22.2 No.223 - IEC/EN 61347-1, IEC/EN 61347-2-13
- Class 2
EMI / RFI Standards
- EN 55015:2006+A1+A2
- EN 61547:2009
- EN 61000-3-2:2006
- EN 61000-3-3:2008
- FCC part 15, Class B verification