planmeca oy 22.1.2015 planmeca compact i classic ki page … · planmeca oy 22.1.2015planmeca...
TRANSCRIPT
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 1(17)
Planmeca Compact i Classic *
Dental unit with unit-integrated chair
Planmeca Compact i Classic is the ideal choice for the needs of general
dentistry. It provides a cost-effective dental unit with all necessary
functionalities. The patient chair is without a chair base and it is
integrated to the cuspidor by a side lifting mechanism.
Planmeca Compact i Classic has a traditional membrane keyboard with
basic unit, instrument and infection control functions. Keyboard is also
available for the assistant suction arm to provide easy and ergonomic
use. The instrument locations are interchangeable due to an instrument
hose quick connection system.
* Planmeca Compact i Classic v2 (all markets excluding Japan and China)
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 2(17)
1. APPROVALS
1. Type testing / CB-certification according to standards
a) IEC 60601-1:2005
b) ISO 6875
c) ISO 7494-1 & ISO 7494-2 & ISO 10993-1 & ISO 9168
2. EMC-testing according to standard IEC 60601-1-2
3. CSA-certification according to standards:
CAN/CSA-C22.2 No. 60601-1:2008
4. FDA market clearance - 510(k) premarket notification
5. CE marked according to MDD
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 3(17)
2. SUPPORT COLUMN AND INSTRUMENT CONSOLE
2.1 Support column
Allows firm mounting of delivery arm, SingLED operating light and LCD
monitor
The support column and the different mounting arms can be rotated
simultaneously according to the user’s preferences
The support column rotates gradually, 60 ̊ at a time, by simply lifting
2.2 Over-the-patient console arm
Available as 520 mm long
Effortless to position, light movements, needle bearing mounted; also
for left-handed use
Spring balanced for easy lock-free height adjustment, adjustable
friction
Due to wide swivelling range (over 380 degrees) easy to move to
assistant's side for instrument cleaning or patient entry/exit
The rotation can be adjusted gradually, 8 ̊ at a time
In case the space is limited, the delivery arm limitation is reasonable
Smooth hygienic construction, no seams, all cast-metal construction.
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 4(17)
2.2.1 OP Balanced instruments
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 5(17)
Integrated user interface with membrane keyboard on the left hand
side of the console reachable by the assistant side as well
Small and compact to work with
Open handle both on the doctor's and on the assistant's side, allows
using disposable sleeves.
Ergonomic, seamless and hygienic surfaces, aluminium instrument
console with powder painted epoxy surfaces
Easily cleanable, removable balanced instrument (doriot) arms.
Mid-flexing balanced instrument arms provide long, friction-free
movements for instrument hoses. The hoses are easily connected to
the balanced instrument arms without any tools. The tension of the
instrument arms can be adjusted without tools according to instrument
weight.
Autoclavable hygiene membrane for the console.
Autoclavable silicone tray mats available for tray tables
Optical recognition for instrument activation.
Quick connect tray table is attached under the instrument console and
can be de-attached easily without tools
Tray table can be attached to tray arm from each side thanks to
magnetic connector
Tray table mounting arm swivels 360 ̊
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 6(17)
2.2.2 OP hanging tube instruments
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 7(17)
Integrated user interface with membrane keyboard on the right hand
side of the console.
Small and compact to work with.
Instrument tray table on top of the instrument console (1-, 2- or NA -
size) or large integrated tray at the side of the console.
Autoclavable silicone tray mats available for tray tables
Handle on the left hand side (integrated tray) or on both sides (top
tray table) of the console.
Ergonomic, seamless and hygienic surfaces.
Adjustable angle of instrument holders.
Quick-disconnect instrument holders for better asepsis.
Optical recognition for instrument activation.
3. INSTRUMENT SELECTION
5 instrument locations (4 + syringe).
Number of available instruments: 9 for instrument console, 3 for
assistant side.
All instruments can be interchanged by the user without tools. Only
the syringe has a fixed location on the left-hand place.
Any instrument combination is possible.
Instrument selection can easily be expanded to more than five due to
instrument hose quick-connection system and the possibility to store
up to 8 pre-programmed instrument settings.
3.1 List of available instruments
Turbine instrument hose with 4-hole standard connection and fibre
optic light; also a sonic scaler can be connected.
2 micromotors with ISO connection and with LED light, one of the
motors is brushless
Air motor hose
Ergo 6-way syringe
Ergo 3-way syringe
Intraoral camera
Piezo scaler
LED polymerisation light
Assistant Ergo 6-way syringe
Assistant Ergo 3-way syringe
Assistant LED polymerisation light
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 8(17)
3.2 Instrument features
All instrument hoses have quick connection for easy instrument
changing and cleaning.
Contamination prevention system for turbine prevents air suck-back to
instrument, connector and tubing.
Non-return valves in the multiplexers prevent cross contamination.
Smooth, wipe-clean, silicone instrument hoses, easy to detach.
Programmable instrument air and water flow controls. Air and water
pressure are controlled by software. If the pressure changes, software
takes care that instrument can not be used due to the heating, if e.g.
there is not enough water coming.
Instrument settings are individually programmable for 8 instruments
simultaneously and follow the specific hose if changed to another
location.
Advanced Instrument Safety Logic for 4-handed dentistry: The
instrument last activated by foot control will stay active until returned
to the holder, thus allowing service of the other instruments.
Automatic short and long instrument hose and waterline flushing
system. Integrated flushing holder as a standard.
4. USER INTERFACE
Standard control panel on the instrument console; optional assistant’s control panel attached to the suction arm.
Sealed hygienic panel(s) for controlling chair, spittoon, operating light, instrument, and programming functions.
Tactile positive control push buttons.
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 9(17)
LED display indicates the activation of unit and instrument functions.
Extensive self-diagnostic help and error code system continuously monitoring all the functions. The system helps the user to solve a problem alone or to give an accurate diagnose for a technician by phone.
Individual controls for:
Instrument cooling spray: on/off and adjustment of water and air (0-100 %)
Intensive and short unit water line + instrument flushing
Quick start for turbine
Intensity of the instrument fibre optic light
Micromotor rotation: normal/reverse
Automatic chip blow: on/off and adjustment of water and air (0-100 %)
Activation of polymerization light from any instrument button
Bowl rinse/glass fill and adjustment of time for both
Nurse call/door open and adjustment of time
Power on/off and speed/power indicator
Dental light: intensity adjustment and on/off
Chair positions: automatic and manual
Spittoon position for chair.
5. FOOT CONTROL
Electric foot control with handle operates all chair, unit and instrument
functions:
Instrument speed/power, proportional
Spray on/off
Chip blow activation to dry the cavities
Instrument power selection
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 10(17)
Control for chair: manual, automatic (4 + spittoon position) and
stop movements.
Bowl rinsing and glass filling
Freeze and save intraoral video camera images
Door open or nurse call
Micromotor reverse optional; normally it is disabled for safety
reasons.
No wearing electrical parts like microswitches, uses more reliable
capacitive system.
Small size and stable cast zinc construction
Symmetrical design: the instruments can be operated from mid
position to either direction
Alternatively vertical operation of the foot control pedal for instrument
control
Clear and resistant laser markings
Optional protective earth grounding terminal
IPX1 classification
6. TRAY TABLES
6.1 OP Balanced instruments console tray table
Quick connect tray table for 1-size tray (194 mm x 296 mm)
Quick connect tray table for 2-size tray (296 mm x 380 mm)
Quick connect tray table for NA size (9” x 12.9”)
6.2 OP Hanging tubes console tray table
Quick connect top tray table for 1-size tray (194 mm x 296 mm)
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 11(17)
Quick connect top tray table for 2-size tray (296 mm x 380 mm)
Quick connect top tray table for NA size (9” x 12.9”)
Integrated tray table for 2-size tray (280 x 370 mm)
7. CUSPIDOR
Integrated with chair.
All connections, tubes and filters for central water supply and drain
located inside the unit to improve surface hygiene.
Blue cuspidor bowl
Glass bowl can be easily removed and washed in a dishwasher.
Glass bowl swivels for easy reach by the patient. The chair can be
driven upwards when the bowl is turned over the chair, but as a safety
precaution the chair stops within a certain safety margin from the
bowl.
Sensor for cup allows filling of the cup only when the cup is in the
holder.
Integrated cup stand.
Cuspidor body of cast aluminium, galvanized steel, finished with baked
epoxy powder coating. Fully corrosion resistant. Top cover made of
PBT.
All screws, tube connectors and other fittings are corrosion resistant.
Safety switch inside the cuspidor prevents the up-down movements of
the chair if the door is open to protect the serviceman from accidents.
Automatic unit waterline flushing system.
Integrated flushing holder as standard
Coarse filter:
Filter in the suction line traps large amalgam particles.
Coarse filter insert is removable for cleaning and replacement.
Disposable trap filter of the bowl for added infection control.
Options:
Clean water system (= bottled water system)
8. SUCTION ARMS
Suction holder
Integrated activation switches: suction is automatically activated when
the tube is lifted from the holder.
Hygienic design, no need for calibration.
Suction tubes and nozzles
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 12(17)
Two suction tubes: vacuum-operated High Volume and Saliva Suction.
Tubes are removable, with quick connectors.
Adjustable suction power.
Patented High Volume Suction nozzle opens automatically when tilted
and closes automatically when straightened allowing temporary
stopping of suction during operation if necessary.
Small saliva ejector nozzle with on/off suction control switch.
Suction nozzles can be removed, disassembled and autoclaved at 135
°C (275 °F).
Options
Assistant 6-way syringe.
Assistant 3-way syringe.
Assistant LED polymerisation light.
8.1 Adjustable suction arm
Tilt-up, tilt-down suction holder.
Optional: second HVE or saliva hose, assistant syringe, LED
polymerisation light.
8.2 Adjustable suction arm with keyboard
Control panel with chair, unit, instrument, programming and display
functions.
Optional: second HVE or saliva hose, assistant syringe, LED
polymerisation light.
Open or closed use of the holders with clip-on roller.
9. SUCTION SYSTEM ALTERNATIVES
9.1 Wet suction system
Without separator, requires “wet”-type suction motor.
9.2 Planmeca VS/A – Compatible Suction System
Planmeca offers unit model which is compatible with a VS or VS/A
suction motor. VS suction motor includes an integrated automatic
water/air separator and VS/A motor additionally a centrifugal amalgam
separator (collects 97,5 % of amalgam).
9.3 Dry suction system Microvac
Compact, automatic separator Planmeca Microvac II.
Microvac II is an automatically self-cleaning and -rinsing separating
tank.
Allows non-stop suction.
The complete assembly is easy to service.
Installation of a dry suction motor (quoted separately) is required.
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 13(17)
9.4 Dry suction system Dürr CS1
Compact and small size
Brushless motor – maintenance free
Installation of a dry suction motor (quoted separately) is required
10. ARM ASSEMBLY ALTERNATIVES
Operating light adapter post (support column)
Attached vertically to the console arm or directly to cuspidor.
Allows installing Planmeca SingLED operating light.
Does not affect or limit the movements of the instrument console arm:
the console arm can be operated also when placed on the left-hand
side.
Mounting arm for LCD monitor
Attached horizontally to the support column
Swivels horizontally and allows adjusting monitor viewing angle
The support column and the LCD monitor arm can be rotated
simultaneously according to the user’s preferences
11. CONSTRUCTION, COATING AND COLOUR OF UNIT
Solid cast aluminium, corrosion free construction.
Electroplated or hot galvanized steel parts.
Baked epoxy powder finish on all external metal parts is scratch and
chip resistant and easy to clean.
Unit colouring: Pearl (RAL 9016)
11.1 Solenoids
All solenoids have acid-proof stainless steel plungers.
11.2 Installation
Junction area inside the cuspidor - no separate junction box needed.
Electric power supply with protection circuits.
Indicator light fuses and master on/off switch.
11.3 Filters
Filter for compressed air (25 µm) with automatic water condensate
separator.
Filter for water (25 µm).
5 µm filter in the water line before unit recommended (quoted
separately).
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 14(17)
12. DIGITAL COMMUNICATION POSSIBILITIES
Planmeca Compact i Classic can be connected to Planmeca Romexis
software. The Clinic Management module of Planmeca Romexis offers
valuable tools for dental unit users:
Personal user settings for unlimited number of users
Real-time remote monitoring of dental unit operation
Accurate information of all dental unit usage and possibility to
create different kind of reports based on the gathered information
for service, educational and business planning purposes
Remote mass updates for dental unit software
The following features of the Planmeca Compact i Classic dental unit can
be monitored and controlled through Clinic Management module:
Instruments:
Instrument type
o Micromotor, turbine, polymerisation light, scaler, syringe
Usage hours
Momentary power level
Power / scaling mode / time settings
Auto chip blow
o On/off
Spray
o On/off
o Level (water / air content)
Fibre light
o Light level setting
o On/off
o Bulb-on hours
Chair
Activation
Position
Auto position settings
Seat
Backrest
Motorized headrest (optional)
Operating light
On/off
Intensity
Suction System
Hose activation
Motor control
Separator alerts
Infection control features
Instrument flushing cycles
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 15(17)
Service Info
Error/Alert history
Service modes
System settings
13. TECHNICAL INFORMATION
The unit is pre-set at the factory to one of the three different mains
voltage settings. The possible voltage settings are:
* 100 VAC
* 115 VAC
* 220…240 VAC
The voltage setting for the complete unit can be altered by re-wiring a
voltage jumper on the main control PCB.
Mains frequency 50 or 60 Hz (cycles) independent of the
mains voltage setting
Power consumption The idle power consumption is less than 300
VA.
Maximum power consumption is 1200 VA.
Water inlet pressure 3 bar to 9 bar (43 psi to 130 psi)
Air inlet pressure 5,5 bar to 9 bar (80 psi to 130 psi)
Suction line pipe ø min. 50 mm (2”)
Drain line pipe ø min. 50 mm (2”)
Weight About 130 kg
All Planmeca products are manufactured according to Quality
Standard ISO 9001:
ISO 9001 Quality System Standard, Certificate No. 95-HEL-AQ-166
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 16(17)
14. PLANMECA COMPACT PATIENT CHAIR
14.1 Chair integrated to the unit
Designed for dental care of both adults and children.
Wide, stable support for back and arms.
Slim upper backrest for better access
Side-lifting mechanism together with a thin backrest provides
exceptional access for operator and assistant.
Headrest-to-cuspidor distance 750…620 mm (depending on headrest
slide position). Allows for easy manoeuvring from the left side of the
patient.
Compensating movement of backrest provides ideal comfort for the
patient. Swivel point of backrest has been positioned high to hip level
to enable tilting without movement between the human back and the
seat. Backrest surface is following the body surface during the
movements.
Double articulating prosthetic headrest allows optimum patient
positioning, with hygienic design.
Anatomical seat angulation.
Integrated elbow support.
Chair can be driven to the horizontal position.
Multiprocessor controlled.
Pre-programmed working positions with memory, 4 positions and a
spittoon position.
Trendelenburg position
Automatic glass filling, bowl rinsing and operating light off -function
when S (spittoon)-position is activated. By pressing S-key the second
time the bowl will be rinsed again, the chair returns to the previous
position and operating light comes on automatically if it was on before.
Automatic and manual chair functions from both the unit keyboard and
foot control. Automatic/manual function separated by time delay.
Powered by two low-noise electric motors, one for the seat and the
other for the backrest.
Lifting capacity 135 kg (297 lbs).
Dimensions: seat length 112 cm (44 1/10”), seat width 55 cm (21
1/2”).
Seat height: min 350 mm (13 3/4”), max 810 mm (32”).
Backrest height 57 cm (22 1/2”), backrest width 62 cm (24 2/5”).
Backrest casting 20 mm / 0,80 inch and total backrest thickness with
the upholstery 50 mm / 2 inches
Setting of the chair backrest up to 65°.
Headrest slide range 130 mm (5”).
PLANMECA OY Planmeca Compact i Classic 22.1.2015
KI Page 17(17)
Powder paint finish is scratch and chip resistant and not affected by
surface disinfectants.
Solid cast aluminium construction and painted inner surfaces
guarantee a sturdy, corrosion free design, stainless steel screws.
Electroplated or hot galvanized steel parts.
Standard colour RAL 9016 white.
Armrests and surgical IV armrest available as an option.
14.2 Safety features
Backrest is free to move upwards so that the operator's knees cannot
be trapped when the chair is lowered.
Electronically controlled overload protection.
Chair movement can be stopped in an emergency by operating any
function on the foot control or any chair control key on the control
panel.
Safety switching under the chair base.
Legrest can freely move upwards if obstructed.
Chair movements are disabled if instruments are operated.
The chair can be driven upwards when the bowl is turned over the
chair, but as a safety precaution the chair stops within a certain safety
margin from the bowl.
14.3 Upholsteries
Comfy upholstery: comfortable and firm foam covered with seamless
artificial leather.
Ultra Relax upholstery: viscoelastic memory cell foam covered with
Ultraleather. Adjusts to different body shapes.
14.4 Headrest
Oval and rectangular headrest cushions.
The double articulated headrest enables the positioning of the patient’s
head and provides good visibility into the oral cavity.
Pressing one single release allows two independent adjustments for
upper and lower jaw visibility.
The headrest cushion provides good support for the patient and holds
the head firmly in position.
14.5 Armrests
Optional right and left armrests.
Right side armrest is movable to allow easy patient entrance and exit.
Covered with the upholstery material and available in all colours.
Surgical IV armrest as an option.