presentation 30.07
TRANSCRIPT
![Page 1: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/1.jpg)
![Page 2: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/2.jpg)
II01 SPACE PLANNING SYSTEM
ironicoiconico
![Page 3: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/3.jpg)
II01 space planning system INDICE
![Page 4: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/4.jpg)
II01 space planning system METAPROGETTAZIONE
“L’idea da cui è scaturito il sistema II01 è creare un sistema flessibile e funzionante recuperare e dare nuova vita a spazi altrimenti inutilizzati.”
![Page 5: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/5.jpg)
II01 space planning system METAPROGETTAZIONE
“L’idea da cui è scaturito il sistema II01 è creare un sistema flessibile e funzionante recuperare e dare nuova vita a spazi altrimenti inutilizzati.”
![Page 6: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/6.jpg)
II01 space planning system METAPROGETTAZIONE
![Page 7: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/7.jpg)
II01 space planning system METAPROGETTAZIONE
RIFERIMENTI
![Page 8: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/8.jpg)
II01 space planning system METAPROGETTAZIONE
Pollmeier, BauBuche
MICROLAMELLARE IN FAGGIO
fy,k = 70 N / mm2
ρk = 680 kg/m3
Consonni Legnami Snc, CO
METODI DI PRODUZIONE :!
� INNOVATIVI - CNC
� TRADIZIONALI
+ 100% resistenza
+ 50% peso
![Page 9: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/9.jpg)
II01 space planning system METAPROGETTAZIONE
SISTEMA SPAZIALE MODULARE
![Page 10: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/10.jpg)
II01 space planning system METAPROGETTAZIONE
Funzionale 1
Distributivo 1
Interferenze 1
![Page 11: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/11.jpg)
II01 space planning system METAPROGETTAZIONE
Funzionale 2
Distributivo 2
Interferenze 2
![Page 12: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/12.jpg)
II01 space planning system IL KIT COSTRUTTIVO
![Page 13: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/13.jpg)
II01 space planning system IL KIT COSTRUTTIVO
![Page 14: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/14.jpg)
II01 space planning system ANALISI STRUTTURALE
ATTACCO ALLA BASE
COMPRESSIONE SLU: NEd ≤ NRd 40,60 kN ≤ 107,23 kN
INSTABILITÀ: NEd ≤ PCrit 40,60 kN ≤ 1578,13 kN
35,19 kN
77,76 kN
1600 kN
166,75 kN
![Page 15: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/15.jpg)
II01 space planning system ANALISI STRUTTURALE
ELEMENTI A CROCE
COLLARINO x 4
4,18 kN
10,80 kN
TAGLIO SLU: τvd ≤ fvd
194,68 N/mm² ≤ 195,20 N/mm²
![Page 16: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/16.jpg)
II01 space planning system ANALISI STRUTTURALE
TRAVE
FRECCIA SLE: unet,fin ≤ ulim 1,39 cm ≤ 1,80 cm
INSTABILITÀ SLU PERMANENTI: LAMELLARE 0,24 ≤ 1 BAUBUCHE 0,22 ≤ 1
INSTABILITÀ SLU MEDIA DURATA LAMELLARE 1,10 > 1 BAUBUCHE 0,65 ≤ 1
3,07 kN/m
10,80 kN/m
![Page 17: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/17.jpg)
II01 space planning system ANALISI STRUTTURALE
TRAVETTO
2,70 kN/m
0,49 kN/m
FRECCIA SLE: unet,fin ≤ ulim LAMELLARE 1,90 cm > 1,80 cm BAUBUCHE 1,59 cm ≤ 1,80 cm
![Page 18: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/18.jpg)
II01 space planning system ANALISI STRUTTURALE
PILASTRO
COMPRESSIONE SLU: ςc,0,d ≤ fc,0,d 2,03 MPa ≤ 20,48 MPa
INSTABILITÀ SLU PERMANENTE: 0,2 ≤ 1
INSTABILITÀ SLU MEDIA DURATA: 0,53 ≤ 1
35,19 kN
77,76 kN
![Page 19: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/19.jpg)
II01 space planning system ANALISI STRUTTURALE
PILASTRO
VERIFICA SLU A TAGLIO: VEd ≤ Fv,Rd
PERMANENTE: 3,81 kN ≤ 45,75 kN
MEDIA DURATA: 13,53 kN ≤ 13,68 kN
![Page 20: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/20.jpg)
II01 space planning system ANALISI STRUTTURALE
SOLAIO
0,54 kN
3,00 kN
FRECCIA SLE: unet,fin ≤ ulim 1,07 mm ≤ 4,50 mm
![Page 21: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/21.jpg)
II01 space planning system ANALISI STRUTTURALE
SCALA
FRECCIA SLE: unet,fin ≤ ulim 0,33 cm ≤ 1,90 cm
TAGLIO APPOGGI: Vvite ≥ VEd 1,09kN ≥ 0,72 kN
0,68 kN/m
0,72 kN
![Page 22: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/22.jpg)
II01 space planning system
PARTIZIONE TRASPARENTE
IL KIT COSTRUTTIVO
20 kg
![Page 23: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/23.jpg)
II01 space planning system
PARTIZIONE OPACA
IL KIT COSTRUTTIVO
47 kg
![Page 24: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/24.jpg)
II01 space planning system
KIT PORTA
IL KIT COSTRUTTIVO
![Page 25: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/25.jpg)
II01 space planning system
INGRESSO
IL KIT COSTRUTTIVO
![Page 26: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/26.jpg)
II01 space planning system ANALISI FEM
ANALISI DELLE SOLLECITAZIONI – SAP2000
MATERIALE + SEZIONE + CARICHI
" VERTICALI: PESO PROPRIO + ESERCIZIO
" ORIZZONTALI: SISMA
PILASTRI :
Pmax = 253 kN
Mmax = 28,7 kNm
TRAVE
Vmax = 35 kN
Mmax = 28,7 kNm
![Page 27: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/27.jpg)
II01 space planning system ANALISI FEM
ANALISI DEGLI ELEMENTI – SAP2000
σmax ≤ ( 0,9 σmat ) / 1,45 = 43,5 N/mm2
σ= 126,0 N/mm2
σ= 90,0 N/mm2
σ= 36,4 N/mm2
✗
✗
✔
![Page 28: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/28.jpg)
II01 space planning system ANALISI FEM
ANALISI DEL GIUNTO SEMPLICE - COMSOL
σ= 71,0 N/mm2
σmax ≤ ( 0,9 σmat ) / 1,45 = 43,5 N/mm2
✗
![Page 29: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/29.jpg)
II01 space planning system ANALISI FEM
ANALISI DEL GIUNTO RINFORZATO - COMSOL
σ= 27,8 N/mm2
σmax ≤ ( 0,9 σmat ) / 1,45 = 43,5 N/mm2
σ= 1,0 N/mm2 ✔ ✔
![Page 30: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/30.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
CASO DI STUDIO :
� Via Sbodio, Ventura – Lambrate, Milano
� Superficie 1200 m2
� Hint = 8 m
� Finestratura a nastro
![Page 31: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/31.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
λ [W/mK] ρ [kg/m3] c [J/kgK] Calcestruzzo pannelli 1,600 2300 1000 Calcestruzzo tegoli 1,800 2500 1000 Calcestruzzo pavimento industriale
1,400 2000 1000
EPS portone 0,035 35 1480 Acciaio portone 47,0 7800 480 Alluminio copertura 236,0 2700 877
Uw [W/m2K] g+ Vetro singolo 4 mm con telaio
5,7 0,85
INPUT :
� Milano
� Assenza apporti interni
� Bassa tenuta all’aria
� Prestazioni involucro MODELLO BESTenergy
![Page 32: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/32.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
Date/Time Zone Air Relative Humidity
[%] (Monthly) Zone Mean Air Temperature
[C] (Monthly) January 57,53 6,28 February 45,12 7,84 March 46,89 12,91 April 51,69 15,45 May 53,62 21,02 June 59,56 25,29 July 49,62 28,34 August 55,80 26,18 September 64,89 21,19 October 75,36 15,33 November 64,16 10,29 December 51,53 6,97
Date/Time Zone Mean Air Temperature
[C] (Monthly) January 1,70 February 4,20 March 9,20 April 14,00 May 17,90 June 22,50 July 25,10 August 24,10 September 20,40 October 14,00 November 7,90 December 3,10
BESTenergy
Normativa
![Page 33: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/33.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
U = 0,81 W/m2K U = 0,40÷0,42 W/m2K
OPACA VERTICALE
OPACA ORIZZONTALE
![Page 34: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/34.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
TRASPARENTE VERTICALE
U = 2,0 W/m2K
![Page 35: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/35.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
INPUT :
� Zone termiche
� Prestazioni involucro
� Affollamento ambienti
� Permanenza utenti
� T° comfort interna
� Funzionamento impianti
MODELLO BESTenergy
![Page 36: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/36.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
Consumo energetico annuo invernale 15,69 kWh/m3anno
Consumo energetico annuo estivo 7,87 kWh/m3anno
Caso 1
Potenza di picco invernale 43,68 kW
Potenza di picco estiva 23,03 kW
Stagione invernaleLu-Ve 8.00-20.00 20°C Lu-Ve 20.00-8.00 - Sa-Do 0.00-24.00 -
Stagione estivaLu-Ve 8.00-20.00 26°C Lu-Ve 20.00-8.00 - Sa-Do 0.00-24.00 -
Consumo energetico annuo invernale 21,10 kWh/m3anno
Consumo energetico annuo estivo 7,87 kWh/m3anno
Caso 2
Potenza di picco invernale 32,39 kW
Potenza di picco estiva 23,03 kW
Stagione invernaleLu-Ve 8.00-20.00 20°C Lu-Ve 20.00-8.00 16°C Sa-Do 0.00-24.00 -
Stagione estivaLu-Ve 8.00-20.00 26°C Lu-Ve 20.00-8.00 - Sa-Do 0.00-24.00 -
![Page 37: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/37.jpg)
II01 space planning system ANALISI TERMICA ED ENERGETICA
Consumo energetico annuo invernale 15,69 kWh/m3anno
Consumo energetico annuo estivo 7,87 kWh/m3anno
Caso 1
Potenza di picco invernale 43,68 kW
Potenza di picco estiva 23,03 kW
Stagione invernaleLu-Ve 8.00-20.00 20°C Lu-Ve 20.00-8.00 - Sa-Do 0.00-24.00 -
Stagione estivaLu-Ve 8.00-20.00 26°C Lu-Ve 20.00-8.00 - Sa-Do 0.00-24.00 -
Consumo energetico annuo invernale 21,10 kWh/m3anno
Consumo energetico annuo estivo 7,87 kWh/m3anno
Caso 2
Potenza di picco invernale 32,39 kW
Potenza di picco estiva 23,03 kW
Stagione invernaleLu-Ve 8.00-20.00 20°C Lu-Ve 20.00-8.00 16°C Sa-Do 0.00-24.00 -
Stagione estivaLu-Ve 8.00-20.00 26°C Lu-Ve 20.00-8.00 - Sa-Do 0.00-24.00 -
![Page 38: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/38.jpg)
II01 space planning system ANALISI OTTICO-LUMINOSA
Milano – Cielo coperto
9.00-18.00 – h: 140cm
500 lux
Daylight autonomy: 45,0%
LIVELLO 1 – NASTRO
![Page 39: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/39.jpg)
II01 space planning system ANALISI OTTICO-LUMINOSA
Milano – Cielo coperto
9.00-18.00 – h: 140cm
500 lux
Daylight autonomy: 45,0%
LIVELLO 1 – SHED
![Page 40: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/40.jpg)
II01 space planning system ANALISI OTTICO-LUMINOSA
Milano – Cielo coperto
9.00-18.00 – h: 140cm
500 lux
Daylight autonomy: 18,4%
LIVELLO 2 – NASTRO
![Page 41: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/41.jpg)
II01 space planning system ANALISI OTTICO-LUMINOSA
Milano – Cielo coperto
9.00-18.00 – h: 140cm
500 lux
Daylight autonomy: 76,0%
LIVELLO 2 – SHED
![Page 42: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/42.jpg)
II01 space planning system
Rw = 46 dB L’n,w = 94 dB
OPACA VERTICALE
OPACA ORIZZONTALE
ANALISI TERMICA ED ENERGETICA
![Page 43: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/43.jpg)
II01 space planning system ANALISI ACUSTICA
Rw_tot = 72 dB
R’w_tot = 72 dB
D2m,nT,w_tot = 73 dB
TRASPARENTE VERTICALE
Rw,PCA = 18 dB
![Page 44: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/44.jpg)
II01 space planning system IMPIANTI
STRATEGIA IMPIANTISTICA :
� IMPIANTI A SOFFITTO
� IMPIANTI A VISTA
� CONFIGURAZIONI FLESSIBILI
� ADATTABILITÀ AL CASO DI STUDIO
![Page 45: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/45.jpg)
II01 space planning system IMPIANTI
IMPIANTO A TUTT’ARIA :
� BENESSERE TERMO-IGROMETRICO + IAQ
� PORTATA MASSIMA 11770 m3/h – INVERNALE
� DIMENSIONAMENTO MACCHINARIO
� DIMENSIONAMENTO CANALIZZAZIONI
� CANALI TESSILI LEGGERI IN PE
![Page 46: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/46.jpg)
II01 space planning system IMPIANTI
IMPIANTO ELETTRICO :
� PRESE INDUSTRIALI A SOFFITTO
� LUCI A SOFFITTO
� CALCOLO DEL CONSUMO
CASO DI STUDIO:
110 kWh/m2anno
25 €/m2anno
� DISTRIBUTIVO ELETTRICO
![Page 47: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/47.jpg)
II01 space planning system IMPIANTI
DISTRIBUTIVO ELETTRICO
![Page 48: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/48.jpg)
II01 space planning system IMPIANTI
IMPIANTO IDRICO SANITARIO :
� IMPIANTO DI POMPAGGIO
A CIRCOLAZIONE FORZATA
� DISTRIBUTIVO IDRICO
� DIMENSIONAMENTO
BOILER
![Page 49: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/49.jpg)
II01 space planning system ANALISI ECONOMICA
INDAGINE DI MERCATO " COSTRUZIONE DEL PREZZARIO " ANALISI COMPOSIZIONE DEI PREZZI " PROSPETTIVA VENDITA " PROSPETTIVA AFFITTO
![Page 50: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/50.jpg)
II01 space planning system ANALISI ECONOMICA
CENTRI + 200.000 abitanti " ZONE ACCESSIBILI " ALTEZZA INTERNA 8 – 10 m " SUPERFICI 700 – 1500 m2
" FINESTRATURE A NASTRO - SHED
![Page 51: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/51.jpg)
II01 space planning system ANALISI ECONOMICA
EUR price list
July 2015
![Page 52: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/52.jpg)
II01 space planning system ANALISI ECONOMICA
PR
EZ
ZO
PE
R M
OD
ULO
– n
o I
VA
NUMERO MODULI SIMPLEX
661,39
572,63
542,08
487,13
412,83
1 2 3 4 9
396,46
351,83
12 31
ANALISI COMPOSIZIONE DEI PREZZI
NUMERO MODULI DUPLEX
![Page 53: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/53.jpg)
II01 space planning system ANALISI ECONOMICA
moduli numero moduli
utenti per modulo
affitto postazione
PRIVATE OFFICE 2 1 800 € COWORKING 8 4 400 € GROUP OFFICE 7 4 500 € OTHER SPACES 16 - -
configurazione numero moduli
utenti configurazione
ricavi affitti
CASO DI STUDIO 31 54 24.400 €
analisi dei costi - acquisto
AFFITTO CAPANNONE 3.500 €/mese TRASPORTO 6.000 € MONTAGGIO 7.500 € COSTO SISTEMA 153.400 € ARREDO 65.000 € IMPIANTI 6.000 €/mese COSTI GESTIONE 3.500 €/mese RICAVI AFFITTI 24.400 €/mese ENTRATA MENSILE 14.400 € PERIODO RITORNO 16 mesi
PROSPETTIVA ACQUISTO
![Page 54: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/54.jpg)
II01 space planning system ANALISI ECONOMICA
configurazione costo produzione arredo impianti affitto/mese modulo ritorno
CASO STUDIO 122.699 € 54.492 € 3.000 € 14.000 € 452 € 13
analisi dei costi - affitto
AFFITTO CAPANNONE 3.500 €/mese COSTO SISTEMA 14.000 €/mese ELETTRICITÀ 750 €/mese ACQUA 150 €/mese COSTI GESTIONE 2.000 €/mese RICAVI AFFITTI 24.400 €/mese ENTRATA MENSILE 4.000 €/mese
PROSPETTIVA AFFITTO
![Page 55: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/55.jpg)
II01 space planning system VISUALIZZAZIONE
![Page 56: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/56.jpg)
II01 space planning system VISUALIZZAZIONE
![Page 57: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/57.jpg)
II01 space planning system VISUALIZZAZIONE
![Page 58: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/58.jpg)
II01 space planning system VISUALIZZAZIONE
![Page 59: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/59.jpg)
II01 space planning system VISUALIZZAZIONE
![Page 60: Presentation 30.07](https://reader030.vdocuments.pub/reader030/viewer/2022020123/55cd9d43bb61eb112e8b45b3/html5/thumbnails/60.jpg)
II01 space planning system ironicoiconico
Thank you.