DESCRIPTION
PSS Merlin . SELF CONTAINED BREATHING APPARATUS BODYGUARD II. Combines these safety features in one device: Digital Pressure reading ‘Time To Whistle’ based on actual consumption rate Integrated ADSU / PASS Manual Distress Signal Alarm Temperature Display - PowerPoint PPT PresentationTRANSCRIPT
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/1
PSS Merlin
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/2
Combines these safety features in one device:
● Digital Pressure reading
● ‘Time To Whistle’ based on actual consumption rate
● Integrated ADSU / PASS
● Manual Distress Signal Alarm
● Temperature Display
● Electronic acoustic and optical low pressure warnings
● 2nd Independent pneumatic low pressure warning
● Flexible parameter setting with Windows software
● Data logging
● Telemetry ready IR Communications port
SELF CONTAINED BREATHING APPARATUSBODYGUARD II
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/3
SELF CONTAINED BREATHING APPARATUSBODYGUARD II FEATURES
LH button to illuminate
Pneumatic Whistle
Manual Distress Button
RH button to display
temperature
Warning LEDs
LCD Display
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/4
Digital Cylinder Pressure
SELF CONTAINED BREATHING APPARATUSBODYGUARD II DISPLAY
Clock Icon indicates time
Time To Whistle(TTW)
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/5
SELF CONTAINED BREATHING APPARATUSBODYGUARD IR LINK II SOFTWARE – DATA LOG/PARAMETER MAINTENANCE
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/6
Select events to be displayed on graph
Graphs can also be produced for analysis with many new options
SELF CONTAINED BREATHING APPARATUSBODYGUARD IR LINK II SOFTWARE – ENHANCED DATALOG GRAPHIC
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/7
SELF CONTAINED BREATHING APPARATUSPSS MERLIN - TELEMETRY
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/8
Telemetry - What does it provide now?
Which means vital safety data displayed at the Control Board !
SELF CONTAINED BREATHING APPARATUSPSS MERLIN - TELEMETRY
1. Continuous transmission of Pressure, Time Remaining , Temperature , battery status, etc
2. Two way evacuation/withdrawal signalling with acknowledgements
3. ADSU alarms and manual distress signals
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/9
Each logged on Fire Fighter permanently displayed on ECB - No Scrolling!
Time to WhistleDisplay at Bodyguard
Display window
- customer preference e.g. TTW
SELF CONTAINED BREATHING APPARATUSPSS MERLIN – ECB DISPLAY
Evacuation button
‘On Line’ signal indicator
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/10
Time to WhistlePressure Temperature Time Elapsed
‘information’ button
Time of WhistleDisplay reverts to default selection after x secs
SELF CONTAINED BREATHING APPARATUSPSS MERLIN – “I“ BUTTON OPTIONS
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/11
Datalog Windows Software and data link cable
SELF CONTAINED BREATHING APPARATUSPSS MERLIN – TELEMETRY DATA LOGGING
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/12
Safety of Firefighters !
• Disciplined donning and pre-entry checks• Accountability of Firefighters via Entry Control Board• Pressure, time in, personal details on tally• Maintenance of Team and location data• Calculate initial Time To Whistle • Relieve teams prior to whistle • Control of Emergency rescue teams
Entry Control Officer with control board
SELF CONTAINED BREATHING APPARATUSPSS MERLIN – BA ENTRY CONTROL
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/13
Current information shortfall!
• 1. Time to whistle based on initial pressure• 2. Assumes fixed breathing rate of 40 Ltr /min• 3. No continual monitoring of pressure by ECO• 4. No awareness of distress signals • 5. No evacuation / withdrawal signal protocol• 6. No automatic comprehensive evidential record
Merlin Delivers
• Monitoring of TTW and Display Time of Whistle• Calculates Breathing Rate• Displays pressure on demand• Monitors Distress Signals• Evacuation Signals/ Monitor Withdrawal Signals• Electronic Data logging
SELF CONTAINED BREATHING APPARATUSPSS MERLIN – BA ENTRY CONTROL
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/14
Telemetry - What will it provide in the future?
SELF CONTAINED BREATHING APPARATUSPSS MERLIN - TELEMETRY
1. Physiological Monitoring of core body temperature, pulse, etc
2. Environmental monitoring of ambient
3. Alarms based on environmental and physiological measurements
4. Location?
5. Speech?
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/15
1.Time of whistle (Bodyguard)2.Time to whistle (Bodyguard)3.Pressure4.Temperature5.Elapsed time since log on
•Radio low battery status
•Time of whistle static (TB1/97 initial pressure + fixed breathing rate)
•Time of whistle dynamic (Bodyguard pressure + fixed breathing rate)
•Display flashing ‘x’ mins to whistle (factory default 10 mins)
Factory Settings
“I“ BUTTON DISPLAY OPTIONS
PSS MERLIN WORKSHOPCOMMISSIONING EXPLAINED
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/16
PSS MERLIN ENTRY CONTROL ACCESSORIES
ECB Bracket
3351803
Tripod
3351802
Entry Control Board
3351145/3351616
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/17
Manual Operation :
+
= TB 1/1997
PSS MERLIN ENTRY CONTROL ACCESSORIES
Digital Clock
3351903ECB Cover PVC
3351812
Chinagraph pencil
3351237
Duration Tables
3351845/46/47
DRÄGER SAFETY • TELEMETRYMAY 2007 • 1/18
Vehicle Clip Charger
3351681
4 Way Portable Unit Charger
3351815
ECB Workshop Charger Kit
3351819
ECB Vehicle Charger
3351810
Power Supply
3351804
PSS MERLIN BATTERY CHARGING FLEXIBILITY