  • Kyoto Kagaku Co., Ltd has developed an extensive history and tradition in providing high quality phantoms to the field of radiology. Kyoto Kagaku Co., Ltd continues with its challenge in offering innovative, state-of-the-art solutions for this rapidly developing industry.

    Founded during post-war Japan in 1948, Kyoto Kagaku Co., Ltd originates from the Shimadzu Corporation. Early days of the company began with the production of scientific specimens, anatomical models and skeletons. Its first radiology phantom was developed in the early 1960’s with the collaboration of Shimadzu. Original human tissue substitute materials for diagnostic energy range and therapeutic energy range were also invented. Tissue substitute materials with ultrasound compatibility were a recent development that opened doors to a variety of QA and training phantoms in the field of sonography.

    Through anatomical research and model crafting breakthroughs such as our long sought human tissue substitutes, Kyoto Kagaku strives to perfect the production of anthropomorphic phantoms for medical imaging. Kyoto Kagaku will continue to uphold high standards in developing products that effectively contribute to patient safety and training of healthcare professionals.

    Radiology/Ultrasound Phantoms ―Tradition and Innovation―

    First participation in RSNA (Radiological Society of North America)

    Development of TOUGH serious, human tissue substitute for radiotherapy range in cooperating with the National Institute of Radiological Sciences

    Development of Synthetic Bones

    Multi-Slice CT Phantom

    First Whole Body PhantomFirst ultrasound Examination Phantom

    Chest Phantom N1 "LUNGMAN"

    Dental Head Phantom

    Shimadzu anatomical human model with muscles wins the Gold prize at the International exhibition in Alaska-Yukon Pacific Ocean1909

    The educational scientific division of Shimadzu Corp is established.1895

    The educational scientific specimens division begins to manufacture of anatomical models1925

    Kyoto Kagaku is established.1948

    First resinous skeleton models1954

    First resinous anatomical models1955

    Development of Stomach Phantom in partnership with Shimadzu Corp.1967Development of XUR* with the Japan Atomic Energy Research Institute (JAERI) *XUR: human tissue substitute material see page 371982

    1986

    1988

    1994

    2001

    2004

    2005

    Whole Body Phantom PBU-502007

    Ultrasound Examination Phantom ABDFAN2008Awarded "Grand Prize" of Good Company Award2009

    FAST/ER FAN2010

    2012

    Pediatric Whole Body Phantom PBU-702013See Page 04-11!2014

    see page 20

    01

  • Concept behind Kyoto Kagaku phantoms ―for community and the world―Case example: DEVELOPING THE FRACTURE INFANT PHANTOM

    Bone fractures- is there sign of abuse?

    Child maltreatment

    The Phantom

    Signs of callus

    Spiral fracture Back, scapula and rib fracturesSigns of fractures on the scapulae and ribs are to be inspected not only by their form, but also their location. Rib fractures close to the vertebrae may be potential indicators of the child being thrown.

    Skull fracturesA linear skull fracture may be another indication of child maltreatment. A common cause of injury is blunt force trauma, in which the energy from a blow is transferred over a wide surface area of the skull. At times, fractures display better on x-ray scans than CT imaging and it is crucial to prevent such fractures from being overlooked.

    Supracondylar humerus fractureA supracondylar humerus fracture occurs on the distal humerus above the epicondyles and is a fracture commonly observed in children. Pediatric cases account for approxi-mately 20% of all lateral condyle fractures.

    Lateral

    Typical fractures of an abusive attack have been replicated on the left side of the infant model's body and limbs, including the ulnae and radii. Smaller fractures can be seen around the phantom's wrist.

    Calluses on their own are not definite proofs of abuse cases. However, a number of callus examples can be a result of abusive treatment. For this particular model, calluses have been simulated in the wound healing phase 5 of remodeling to the original bone contour.

    Certain causes of non-accidental pediatric injuries, such as spiral fractures, include maltreatment stimulated by anger or distress.

    : product video is available : publication reference on the product is on page 35

    Information on this brochure is of at the time of printing and specifications may change without prior notice. For the latest information and further details, check our website www.kyotokagaku.com, follow us on Facebook www.facebook.com/kyotokagaku or contact us at [email protected].

    Children around the world are victims to domestic violence and abuse, yet the problem is often overlooked. Noticing the signs of an abusive fracture of a child is the first step to putting an end to these maltreat-ments. This phantom has been designed and developed to cultivate such observation skills in future X-ray radiologists and technicians.

    Legend

    02

  • New Products

    TABLE OF CONTENTS

    PH-50 Newborn Whole Body PhantomPH-1C Pediatric Chest Phantom

    GGO Tumor Phantom

    PH-49 CT Colonography Phantom NCCS

    PH-51 Lumbar Spine Fluoroscopy Training Phantom

    M43E Ultrasound Compatible Lumbar Puncture/Epidural Simulator

    US-10 Female Pelvic Ultrasound Phantom

    US-11 Scrotal Ultrasound Phantom

    US-13

    04

    05

    06

    07

    08

    08

    09

    10

    11Infant Hip Sonography Training Phantom

    Dynamic PhantomsPH-48 Dynamic Heart and Lung PhantomPH-39 Dynamic Thorax PhantomPH-6B

    19

    19

    19Dynamic Cardiac CT Phantom MD-CT

    Diagnostic RadiologyPH-2 Whole Body Phantom "PBU-50"

    PH-2B CT Whole Body Phantom "PBU-60"41350 -000-11 Fractured Hand/Forearm Phantom

    Body plates for PH-2/2B

    PH-2C Pediatric Whole Body Phantom "PBU-70"

    Bone Fracture Pediatric Phantom "PBU-70B"

    PH-1 Multipurpose Chest Phantom N1 "LUNGMAN"

    PH-8 Lung Cancer Screening CT Phantom LSCT001

    PH-4 CT Torso Phantom CTU-41

    PH-3 Angiographic CT Head Phantom ACS

    PH-47 Dental Radiography Head Phantom

    PH-5 CT Abdomen Phantom

    PH-19 Rotation Stomach Phantom TMP-R

    PH-46 CT Prostate Phantom

    PH-18 Stomach Phantom BMU-1

    12

    12

    13

    13

    14

    14

    15

    16

    17

    17

    17

    18

    18

    18

    18

    16Optional and replacement parts

    -Chest Plates-Storage Case-Simulated Tumors-Custom Order Simulated Tumors-Components for Radioisotope

    Dosimetry and RadiotherapyPH-40 Tough Water Phantom WD

    PH-41 Tough Bone Phantom BE-T, BE-H, BE-NPH-42 Tough Lung Phantom LPPH-37

    20

    20

    20

    20Therapy Body Phantom THRA-1

    CT Image Quality Control / AECPH-9 Multi Slice CT Phantom MHT

    PH-45 3D Digital Image Phantom ODA

    PH-7 CT-AEC Phantoms

    PH-13 Digital Mammographic Phantom NCCE

    PH-12 Mammographic Step Phantom AGH-D210F

    PH-22 CT QA Phantom CT-200B

    PH-21 CT QA Phantom JCT

    CT Lung Phantom

    PH-9-2 Ladder Phantom

    PH-10 BMD Chart Phantom UHA

    PH-16 Contrast Detail Phantom

    PH-17 Water Body Phantom WAC

    PH-15 Tissue Substitute Phantoms XUR

    PH-14

    23

    23

    23

    24

    24

    24

    24

    24

    24

    25

    25

    25

    25

    25Acrylic Phantom XAC

    Ultrasound PhantomsUS-5 FAST/Acute Abdomen Phantom "FAST/ER FAN"

    US-8 Pediatric FAST/Acute Abdomen Phantom

    US-7α Fetus Ultrasound Examination Phantom "SPACE FAN-ST"

    US-6 Breast Ultrasound Examination Phantom "BREAST FAN"

    US-3 Abdominal Intraoperative & LaparoscopicUltrasound Phantom "IOUS FAN"

    US-1B Ultrasound Examination Training Phantom "ABDFAN"US-1 Ultrasound Examination Training Phantom "ECHOZY"US-9 Ultrasound Guided Breast Biopsy Phantom

    US-2 Ultrasound Quality Assurance Phantoms11347 -210 Introductory Ultrasound Training Block "REAL VESSEL"

    US-4

    26

    26

    27

    27

    28

    28

    28

    29

    29

    29

    29

    30-34

    35

    Breast Ultrasound QA Phantom

    Multilingual IndexFrançais / Deutsch / Español / Português / / 中文 / 한국 / 日本語

    Publication References

    MRI / Nuclear Medicine

    PH-33 MRI Head Phantom NH

    PH-34 MRI/NM Head Phantom BHC

    PH-24 Myocardial Phantom

    PH-25 Myocardial Phantom HL-D

    PH-29 ECT Hot Cold Phantom SP-6

    PH-28 SPECT QA Phantom JSP

    PH-30 SPECT QA Phantom JS-10

    Brain Phantom IB-20 advanced

    PH-32 MRI Quality Assurance Phantom JMR

    PH-31

    21

    21

    22

    22

    22

    22

    22

    21

    21

    21MRI Quality Assurance Phantom MHR

    CT Whole Body Phantom with Pathologies 13

  • The world's first full body phantom for neonatal radiography.Newborn Whole Body Phantom is the world's first full body phantom for neonatal radiography with correct anatomical structure and movable limbs. Neonatal radiography is an important tool in NICU (Neonatal Intensive Care Unit). Patient positioning and immobilization are essential features. This phantom provides opportunities for hands-on training and experiments to minimize radiation exposure to newborn babies.

    Newborn Whole Body Phantom

    New Products 04

    PH-50

    1. Limbs rotate 360 degrees at shoulders and hip joints.2. Left hand is clenched and right hand is open.3. Life size whole body newborn baby.4. Original human tissue substitute.5. No metal parts or liquid structures.6. Meconium aspiration syndrome can be made per custom order.

    Features

    -Immobilization - Manual immobilization - Immobilization with fixtures

    -Autopsy imaging

    -Radiography - Upright AP (anteroposterior) - Supine AP - Upright lateral - Supine lateral

    Training Skills

    - Skull, spine, ribs, pelvis, scapulae, clavicles, humeri, radius, ulnae, bones of hands, femora, fibulae, tibiae and bones of feet- Lungs and mediastinum

    Anatomies

    Set Includes:1 newborn whole body phantom1 storage case1 set of sample X-ray images1 instruction manual

    SpecificationsSize:phantom size: 42 cm (represent a baby of 50 cm tall)/16.5 inphantom weight: 2.8 kg /6.2 lb

  • Pediatric Chest PhantomImaging and dosimetry for radiosensitive 5-year-old.Chest X-ray is one of the most common examinations in pediatric radiography. This Pediatric Chest Phantom is designed to find out optimal parameters and protocols to minimize radiation exposure to children. The phantom has two kinds of interchangeable lung inserts. The lung vascular insert can be used to study image quality in relation to CT/X-ray protocols. The lung density insert allows users to evaluate dosage distribution in the lung field.

    PH-1C

    New Products

    1.

    2. 3.

    4.

    5.

    6.

    Two types of interchangeable lung inserts are available. ‒lung vascular insert and lung density insert.Pencil-shaped ion chamber for CTDI can be set in the mediastinum.TLD or RPL dosimeters can be set in the thyroid block and the lung density insert.Lung vascular inserts with pulmonary vessels provide life-like radiographs.Detachable internal structure allows insertion of variety of pathologies and targets.Simulates a life-size chest of 5- year-old.

    FeaturesRib, clavicle, spine, mediastinum, scapula, sternum and *pulmonary vessel

    *lung vascular insert only

    Anatomies

    Two types of lung inserts

    Pediatric Chest X-rayPediatric Chest CTDosimetry

    Applications

    Specifications

    05

    TLD or RPL dosimeters can be set in the thyroid block.

    Set Includes:1 five-year-old chest torso main body: synthetic bones are embedded thyroid block diaphragm block1 lung vasculature insert: mediastinum with pulmonary vessels1 lung density insert: mediastinum, lung fields (L・R)1 set of sample images1 instruction manual

    Size:phantom size: 32 x 17 x 38 cm/12.6 x 6.7 x 15 inweight: 6 kg/3.2 lb

    wo types of lunung inserts

    TLD or RPL dosimeters can be set in the thyroid blo

  • Both mixed and pure GGO are provided in variety of sizes and HU numbers.for PH-1 LUNGMAN (p.15) and CT Lung Phantom (p.24)

    Subsolid Nodules Phantom is a set of simulated lesions designed for study and training in Grand-Glass Opacity (GGO) detection and interpretation. Both mixed and pure GGO are provided in variety of sizes and HU numbers. The set also includes 3-D GGO modeled on clinical CT data. The simulated lesions can be attached to the pulmonary vessels of the Chest Phantom N1 “LUNGMAN” or in the CT Lung Phantom.

    GGO Tumor Phantom can be used with PH-1 Chest Phantom see page 15

    Subsolid Nodules Phantom

    New Products 06

    GGO field Solid field TypeItem No. Diameter1234567

    -650

    1.5 cm/0.59 in

    2.0 cm/0.79 in

    -50050

    0

    0.5 cm/0.20 in

    0.3 cm/0.12 in

    0.7 cm/0.28 in0.9 cm/0.35 in

    0.5 cm/0.20 in

    Concentric

    HU

    Mixed GGO with single concentric solid field (No.1-7)

    Diameter HU

    Mixed GGO with single eccentric solid field (No.8-10)

    GGO field Solid field TypeItem No. Diameter8

    9

    10

    -650

    -50

    0

    50

    EccentricHU Diameter HU

    1.5 cm/0.59 in 0.5 cm/0.20 in

    Mixed GGO with double eccentric solid fields (No.11, 12)

    Eccentric

    GGO field Solid field TypeItem No.Diameter

    11

    12

    -650 00.5 cm/0.20 in

    0.5 cm/0.20 in0.7 cm/0.28 in

    0.3 cm/0.12 in

    HU Diameter HU

    2.0 cm/0.79 in

    3D GGO Pure GGO (No. a-h)

    GGO fieldItem No. Diameterabcdefg

    -750-650-550-450-350-250-150

    h -50

    HUGGO fieldItem No. Diameter

    3D-GGO -5901.5 x 1.5 cm/0.59 x 0.59 in

    HU

    1.5 cm/0.59 in

  • CT Colonography Phantom NCCS

    Innovative study tool for safe and effective CT Colon screeningVirtual Colonoscopy with CT colonography is an invasive and demanding examination for patients and people who undergo screening for polyps. CT Colonography Phantom NCCS provides ideal tools to evaluate preparation, including tagging and cleansing, protocol for CT scanning, and software for interpretation.

    PH-49

    New Products

    1.

    2.

    3.4.

    Cylindrical colon units with targets that represent polyps can be set at the position of ascending colon, descending colon and rectum in the life-size lower torso phantom.Four types of colon units are included for evaluation. Each unit has six targets lining in sequence on the inner wall of the unit. Depressed types are to evaluate tumor detection sensitivity, and projection types can be used to evaluate volume measurement accuracy. Depressed I: circle targets with fixed diameter Depressed II: circle targets with fixed height Projection I: half-ellipsoid sphere targets with fixed diameter Projection II: half-ellipsoid sphere targets with fixed ratioContrast agent can be poured into the colon units for tagging.Pencil shaped ion chambers can be inserted in the center of the phantom for CTDI measurement.

    FeaturesSpine, pelvis, femursAnatomies

    -Virtual colonography-Visualization and detection of targets-Study on optimal dose for low dose CT colonography-Evaluation of accuracy of measurement (size, volume)-Study on optimal density of contrast media

    Applications

    Set Includes:1 lower torso phantom (with three holes for colon units and one hole for ion chamber)3 plugs for colon unit hole1 plug for ion chamber hole4 types of colon units (depressed I, depressed II, projection I and projection II)1 acrylic container

    Specifications

    07

    Product Supervision: National Cancer Center (Japan)

    Depressed type -2 variations-

    Projection type -2 variations-

    Virtual Endoscope View Virtual Endoscope View

    Air Image View Virtual Gross Pathology View

    Depressed I: fixed diameter

    Depressed II: fixed height

    a: Outer diameter

    0.7 cm/0.27 in 0.35 cm/0.13 in

    0.7 cm/0.27 in 0.35 cm/0.13 in

    0.025 cm/0.01 in

    0.015 cm/0.005 in

    1.0 cm/0.39 in

    0.25 cm/0.1 in

    0.15 cm/0.06 in

    0.15 cm/0.06 in

    0.1 cm/0.03 in

    0.1 cm/0.03 in

    0.1 cm/0.03 in

    0.1 cm/0.03 in

    0.05 cm/0.02 in

    0.05 cm/0.02 in

    0.5 cm/0.20 in

    0.5 cm/0.2 in

    0.3 cm/0.11in

    0.2 cm/0.07 in

    0.2 cm/0.07 in

    b: Inner diameter c: Height

    a: Outer diameter

    b: Inner diameter c: Height

    Projection I: fixed diameter

    Projection II: fixed ratio

    0.7cm/0.27 in

    1.0 cm/0.4 inch

    0.05 cm/0.02 in

    0.5 cm/0.20 in

    0.7 cm/0.27 in

    1 cm/0.4 inch

    0.1 cm/0.03 in

    0.5 cm/0.2 in

    0.3 cm/0.11in

    0.2 cm/0.07 in

    0.7 cm/0.27 in

    1.0 cm/0.39 in

    0.1 cm/0.03 in

    0.5 cm/0.20 in

    0.3 cm/0.11in

    0.2 cm/0.07 in

    0.1 cm/0.03 in

    0.3 cm/0.11in

    0.2 cm/0.07 in

    a: Diameter

    a: Diameter b: Height

    a

    b

    b

    a

    A i

  • Ideal training tool for hands-on workshop Ultrasonic anatomy and needle access trainingLumbar Spine Fluoroscopy Training Phantom allows various training methods of fluoroscopy guided procedures in pain relief of the lumbar area. The phantom has two types of interchangeable and replaceable inserts with radio-opaque lumbar spine.

    Ultrasound compatible puncture block is anatomically correct and offers realistic image of ultrasound. Both epidural space and subarachnoid space are accessible for training.

    PH-51 M43ELumbar Spine Fluoroscopy Training Phantom Ultrasound Compatible Lumbar Puncture

    /Epidural Simulator

    New Products

    1.

    2. 3.

    1. 2. 3.4.

    Two types of replaceable training block : vertebroplasty block and anesthesia blockLumbar spine L2-L5 can be visualized under X-ray.True-to-life resistance to the needle

    Features

    Anatomies

    -Recognition of fluoroscopic anatomy and landmarks-Vertebroplasty-Fluoroscopy guided epidural anesthesia: needle placement in facet joint injection, root block and discogram.

    Lumbar spine (L2-L5), spinal canal, epidural space (anesthesia block only)

    Training Skills

    08

    Product Supervision:Dr. David Wilson MBBS, BSc, MFSEM, FRCP, FRCR Consultant Radiologist St Luke's Hospital Oxford Senior Clinical Lecturer University of Oxford

    AnesthesiaBlock

    VertebroplastyBlock

    Set Includes:1 lumbar torso1 vertebroplasty block1 anesthesia block1 skin cover 1 syringe1 irrigation bag1 instruction manual1 storage case

    Replacement Parts:41913-000-01 anesthesia block41913-000-02 vertebroplasty block11348-150 skin cover

    SpecificationsSpecifications

    “I have tested the final product with various different manufacturing kits and would have no hesitation in recommending these phantoms to clinicians who wish to teach any of the technical vertebroplasty procedures." DR DAVID J WILSON MBBS BSc MFSEM FRCP FRCRCONSULTANT MUSCULOSKELETAL INTERVENTIONAL RADIOLOGIST

    Replacement Parts:11348-190ultrasound lumbar puncture /epidural block11348-230ultrasound lumbar region skin cover

    Size:33 x 21 x 30 cm13 x 8.3 x 11.8 in

    Ultrasonic landmarks of lumbar spine can be visualized.Skin cover allows marking with a pen.Both upright and lateral positions are possible for training.Translucent blocks allow users to see the needle pathway under direct vision.

    Ultrasound-guided lumbar punctureUltrasound-guided epidural anesthesiaCSF collection and CSF pressure measurement

    Features

    Lumbar spine (L2-L5) including spinous process and transverse processSpinal canal, epidural space

    Anatomies

    Training Skills

    Set Includes:1 lumbar region model1 ultrasound lumbar puncture /epidural block1 lumbar region skin cover2 lumbar region support bases (upright position / lateral position)1 irrigator bag1 tube1 support base1 syringe1 storage case

  • Pathological Phantom Ectopic Pregnancy Phantom

    Female Pelvic Ultrasound PhantomTwo interchangeable inserts to cover basic gyn ultrasound.

    US-10

    New Products

    ・Ectopic pregnancy phantom - ectopic pregnancy in a fallopian tube, bleeding at Douglas pouch

    - Handling and manipulation of transvaginal and transabdominal transducers- Interpretation of sonogram- Visualization and localization of anatomies and pathologies

    Training Skills

    Specifications

    09

    Charlotte Henningsen, MS, RT(R), RDMS, RVT, FSDMS, FAIUM Chair & Professor - Sonography Department Adventist University of Health Sciences

    Set Includes:1 lower torso manikin1 ultrasound pathology unit1 ultrasound ectopic unit1 storage case

    Size:34 x 33 x 24 cm13.4 x 13 x 9.5 in

    Uterine Fibroid

    Ovary

    Endometrial CancerUrinary Bladder

    Uterus

    Pelvis

    Vagina

    DermoidCyst

    Fallopian Tube

    RectumBleeding

    Douglas Cavum

    PathologiesAnatomies

    Urinary Bladder

    Uterus

    Pelvis

    Vagina

    Fallopian Tube

    RectumBleeding

    Ectopic Pregnancy

    Douglas Cavum

    Ovary

    PathologiesAnatomies

    1.2.

    3.4.

    Both transvaginal and transabdominal scanning are possible.Two types of interchangeable phantom inserts with different pathologies.Realistic view of female external genital.Excellent ultrasound image quality.

    Transvaginal Scanning Transabdominal Scanning

    Features

    ning Transabdominal Sca

    ・ Pathological phantom - endometrial cancer, uterine fibroid, dermoid cyst of ovary, bleeding at Douglas pouch

    Anatomies and Pathologies

    The pelvic phantom is unique in that it allows for transabdominal and transvaginal scanning. Though transvaginal scanning is the gold standard for gyn and 1st trimester pregnancy, it is still important to recognize the anatomy from the transabdominal aspect, as patients may present with anatomy and/or pathology that is outside the transvaginal field of view. The transabdominal technique is still a valuable part of assessing the female pelvis. This phantom also provides imaging of normal and abnormal anatomy so that normal protocol can be practiced while still learning to recognize life threatening pathology, such as an ectopic pregnancy. Other pathology such as endometrial cancer and ovarian cysts can also be identified. In a learning environment, this phantom provides a balance of normal and abnormal that will assist in developing the critical thinking skills necessary to successfully evaluate the female pelvis.

  • Repeated training to acquire skills in safe and painless examinationUltrasound evaluation of the scrotum is an effective, safe, and painless imaging method to assess male reproductive organs for tumors, inflammation, and trauma, as well as potential causes of infertility. The ultrasound phantom provides sonographers, residents in training, and physicians, with the opportunity for hands-on training with a scrotal phantom using an ultrasound scanner. Interchangeable normal and cancerous phantom inserts provide examples of anatomy and pathology of the male genitalia to simulate a real-time experience.

    US-11Scrotal Ultrasound Phantom

    New Products

    1. 2. 3.

    Two types of interchangeable scrotums: normal and pathologyExcellent ultrasound image qualityCompatible with any ultrasound system

    Features

    - Patient positioning and preparation for examination- Scrotal ultrasound screening- Visualization of testicular cancer

    Training Skills

    10

    Specifications

    ・ Normal phantom - scrotum, testicle, epididymis and penis

    Normal Phantom

    Pathological Phantom

    ・ Pathological phantom -scrotum, testicle, epididymis and penis -testicular cancer (each one in left and right testis, 10mm dia.)

    Anatomies and Pathologies

    Scrotal

    Testicle

    Epididymis

    Penis

    Scrotal

    Testicle

    Testicular cancer

    RightLeft

    Epididymis

    Penis

    Normal

    Testicular Cancer Set Includes:1 pelvic body1 normal scrotum1 pathological scrotum1 storage case

    Size:34 x 33 x 24 cm13.4 x 13 x 9.5 in

  • Infant Hip Sonography Training PhantomBest tool to teach Graf's method

    US-13

    -Setting and preparation for hip sonography-Changing the position of the infant-Communication and interaction with the infant's guardian -Correct positioning and use of the transducer-Recognition of ultrasonic landmarks for hip sonography -Visualization of standard, anterior and posterior planes-Interpretation and morphological classification of the sonogram

    Training Skills

    Specifications

    11

    1.

    2. 3.

    4.5.

    World exclusive training model for hip sonography on a full body manikin of 6-week-old infantBilateral hips for examinationKey landmarks that can be recognized under ultrasound include: chondro-osseous junction (bony part of femoral neck), femoral head, synovial fold, joint capsule, labrum, hyaline cartilage preformed acetabular roof, bony part of acetabular roof, bony rim (check list I), lower limb of os ilium, correct plane, labrum (check list II).Facilitate anatomical understanding The full body manikin with movable arms allows training in supporting and changing the position of the infant.

    Features Anatomies

    This is the world's first training phantom with ultrasound anatomy of a 6-week-old infant and it expands training opportunities for pediatricians, radiologists and orthopedists. Before working on real infants, trainees can repetitively practice on this phantom to become familiar with the examination procedures and key points. Using real ultrasound devices, trainees can learn key ultrasound landmarks to identify standard plane for Graf's classification. This is a foundation to acquire skills in handling and positioning of the baby as well as correct positioning of the transducer. The life-size full body manikin has movable arms that allows for realistic training in supporting and changing the position of the infant while interacting with his/her guardian.Product Supervision: Univ. Prof., Prof. hc. Reinhard Graf, M.D.

    labrum

    cartilage acetabular roofbony rim

    (plane)

    lower limb

    ilium

    great trochanterfemoralhead

    Set Includes:1 ultrasound infant phantom1 instruction manual

    The photo is of a prototype.Pecora: examination cushion for hip sonography *not included in the set

    New Products

  • PBU-60

    An essential asset for every radiography programWhole Body Phantom PBU-50 and CT Whole Body Phantom PBU-60 are full size anthropomorphic phantoms with movable and detachable joints for positioning. Each phantom can be separated into 10 individual parts, allowing a wider application in training and research. Neither phantom has metal parts or liquid structure.

    PH-2Whole Body Phantom "PBU-50"

    PH-2BCT Whole Body Phantom "PBU-60"

    12

    Specifications

    Anatomies

    PBU-50

    Main joints have close-to human articulation

    PBU-60

    PBU-50

    Set Includes:1 whole body phantom (separable into 10 parts) *bones and internal organs listed above are embedded.1 head supporter1 flat head screwdriver1 set of sample X-ray images

    packing size: 85 x 60 x 44 cm x 2 boxes33.5 x 24 x 17.3 in x 2 boxes packing weight:80 kg/176 lb

    phantom height:165 cm/65 in

    phantom weight:50 kg/110 lb

    Optional Parts:41363-0102 storage cases

    Internal organs PBU-50 PBU-60 HU number at 80KeV Internal organs PBU-50 PBU-60 HU number at 80KeVBrainCerebrumMesencephalonCerebellumCerebral ventriclesEye ballsArteries with contrastmedium (left half only)LungsPulmonary vesselsTracheaHeartLiver

    ○○○○○○

    ○○○

    ○○

    ○○

    ○○

    4040401020

    250

    -10008

    trachea wall: 8 / inside: -1000PBU-50: 8 / PBU-60: 40

    70

    Portal and hepatic veins ○ 40PancreasKidneysGallbladderSpleenSeminal vesicleAortaCavaUreterUrinary bladderProstateRectumSigmoid Colon

    ○○○○

    ○○○○○○○○

    303020

    254070

    ureteral wall: 30 / inside: 101050

    rectum wall: 70 / inside: -800colon wall: 70 / inside: -800

    50

    Bony structure PBU-50 PBU-60Synthetic skullCervical vertebraeVertebraeClaviclesRibsSternumScapulaCoxal bonesFemurs

    ○○○○○○○○○

    ○○○○○○○○○

    Elbows: Shoulders:

    PBU-50 is ideal patient for radiographer student with close-to-human absorption rate and articulation.

    PBU-60 has full internal organs with proper HU numbers.

    Knees: Hip Joints: bend up to approx. 90 degrees.rotate fu l l 360 degrees in the

    sagittal plane, approx. 180 degrees to side-ways.

    bend up to approx. 90 degrees.An adjustable head supporter comeswith the set, facilitating various headposition setting.

    rotate forward up to approx. 90 degrees, then abduct up to 45 degrees each.

    Diagnostic Radiology

    P.35

  • Fractured Hand/Forearm Phantom CT Whole Body Phantom with PathologiesOptional Parts for PH-2/2B

    Optional Parts for PH-2/2B

    Optional Parts for PH-2/2B

    X-ray phantom for trauma evaluation

    Body plates to simulatea body of BMI30

    41350-000-11

    Body plates for PH-2/2B

    Customized PH-2B

    Bone fractures:ulna, radius, first metacarpal, middle phalanx of the index finger, distal phalanx of the first finger (compressed fracture),fifth metacarpal

    The body plate provides the phantom with a variety of body shapes.

    Specifications

    13

    Left hand/forearm phantom with bone fractures for radiography. The phantom is interchangeable with either PBU-60 or PBU-50's left hand/forearm.

    Set Includes:1 fractured hand/forearm phantom

    Pathological findings in the phantom expand possibilities in trainingapplication.

    Spondylolisthesis

    Subarachnoid bleedingBrain tumor

    Pulmonary tumor

    Pancreatitis

    Kidney stone

    Hepatic tumor

    Gall stone

    Appendicitis

    a b

    c

    d

    e

    fg

    ih

    b

    d

    e

    fg

    h

    a

    c

    Diagnostic Radiology

    41363-010 2 carrying cases

  • This Phantom is easy to handle positioning, and provides complete bone images for every joint.

    Improve your skills in detecting bone fractures in children.

    PH-2CPediatric Whole Body Phantom "PBU-70"

    Bone Fracture Pediatric Phantom "PBU-70B"

    Specifications

    14

    Pediatric Whole Body Phantom is modeled after a 5-year-old child of 105cm (43") in height. This is a life-size, full body anthropomorphic phantom with a state-of-the-art synthetic skeleton, lungs, liver, mediastinum and kidneys. Its movable and detachable joints allow various positioning.

    Training in pediatric radiography can be enriched with clear and subtle bone fractures. Typical fractures resulting from child abuse are also included.

    See also page 2

    - Plain X-ray photography and basic CT scanning- Basic patient positioning for X-ray and CT

    Training Skills1.

    2.

    3.4.

    Main joints have life-like articulation, allowing various positioning for plain X-ray.Tra ining and research appl icat ions can be enr iched by disassembling the phantom into 10 individual parts (head, limbs and trunk). The phantom has no metal parts or liquid structures.No defect in bone images of joints.

    Features

    - Full synthetic skeleton- Main pulmonary vessels, mediastinum, liver, kidneys

    Anatomies

    Set Includes:1 pediatric whole body phantom: life-size, 5-year-old consists of 10 parts1 head supporter1 hand fixture belt1 set of sample X-ray images

    Optional Parts:41303-060storage case for PH-2C

    Size:phantom height: 110 cm/43.3 in phantom weight: 20 kg/44 lb

    Spiral Fracture of the Distal Tibia Forearm Shaft Fractures

    All fractures are prepared on the left side of the phantom.

    * Specify with or without adult teeth at the time of order.

    Fifth Costal BoneFifth Costal Bone

    ScapulaScapula

    Supracondylar Fracture of the Humerus

    Supracondylar Fracture of the Humerus

    Spiral Fracture of the Distal TibiaSpiral Fracture of the Distal Tibia

    Fracture Callus of the FemurFracture Callus of the FemurForearm Shaft FracturesForearm Shaft Fractures

    Skull FractureSkull Fracture

    Diagnostic Radiology

    P.35

  • Plain radiographyRadiograph trainingInterpretation trainingAssessment of tube voltages, films and other devices

    Computed tomographyCT scan trainingInterpretation trainingAssessment of computer-aided detection systems PLAIN X-RAYCT

    "LUNGMAN" Training Skills

    Review the plain X-ray

    Attach the simulated tumors

    Comparison

    Simulated tumors in five-size and three-HU-number variations can be attached to arbitrary position in the lung field.

    – 800

    – 630

    +100

    Improve interpretation skills

    Simulated tumors (HU# 100)

    Comparison between Plain X-ray and CT, as well as between these images and the direct observation of the phantom, helps trainees to have three dimensional understanding and to improve X-ray interpretation skills.

    Multipurpose Chest Phantom N1 "LUNGMAN"PH-1

    Specifications

    15

    Broad range of possible applications in research and training.

    1.

    2.

    3.

    4.

    5.

    6.

    7.

    Applicable for both plain radiography and CT scanning.Simulated tumors and other targets can be attached at any points in the lung field.Wide variety of uses in interpretation training, anatomical education, evaluation and assessment of devices and other research.Accurate anatomy and high quality substitute materialsArms-abducted position of the torso suits the CT scanning. The pulmonary vessels are spatially traceable. Assessment of computer-a ided detection systems is possible.

    Features

    The phantom provides life-like radiographs very close to actual clinical images. The three-dimensional structure allows both PA and LATERAL images to be obtained. The phantom bones and vessels show life-like contrast gradations on the image along with tube voltages.PH-1 is used in a study by the FDA to create a database of CT scans with different scanners and protocols, as a resource for assessment of lung nodule size estimation method.

    Kiyoshi Murata, Ph.D. Professor Norihisa Nitta, Ph.D.Shiga University of Medical Science

    Production supervision:

    Set Includes:1male chest torso main body: synthetic bones are embedded mediastinum: heart, trachea pulmonary vessels (right and left) abdomen (diaphragm) block: no internal structure15 simulated tumors (15 variations 1 piece each) 3 varieties of Hounsfield number: approx. -800, -630, +100 5 sizes for each type:   diameters 0.3, 0.5, 0.8, 1.0, 1.2 cm  diameters 0.12, 0.2, 0.32, 0.39, 0.47 inSize:phantom size: 43 x 20 x 48 cm, chest girth 94 cm 17 x 8 x 18 in, chest girth 37 inphantom weight: 18 kg/39.6 lbpacking size: 65 x 55 x 29 cm, 25 kg 26 x 22 x 11 in, 55.1 lb

    Diagnostic Radiology

    P.35

  • Chest phantom for standardization studies in low dose lung cancer CT screening.

    Chest Plates41337-010

    Storage Case41363-020

    Simulated Tumors

    Components for Radioisotope

    41337-070Custom ordersimulated tumors

    Optional and replacement parts PH-8Lung Cancer Screening CT PhantomLSCT001

    Specifications

    16

    LSCT001 is a unique phantom dedicated for optimizing lung cancer CT screening conditions for early cancer detection, as well as setting standard conditions across multiple systems or facilities for mass screening. Anthropomorphic structure of the phantom provides life-like images allowing operators visual evaluation. Quantitative evaluation on radiation dose and density curve of the image can be done simultaneously with a single scanning.

    1.

    2.

    3.

    Original human tissue substitute material creates life-like artifact under CT scanning.Simulated GGO type tumors with different sizes and HU numbers are prepared in the vicinity of three main sections of bilateral lungs.Dosimeter holder on the central axis of the phantom allows housing a pencil type ion chamber. 8-step cylindrical linearity phantom to control density curve as a scale can be attached to the chest phantom base.

    Features

    for PH-1

    (standard set)

    ‒ 800

    ‒ 630

    +100

    41337-03041337-040

    41337-050 41337-060

    41337-020

    41337-020 Lungs of urethane41337-030 Liver RI container41337-040 Gallbladder RI container41337-050 Pulmonary nodule RI container41337-060 Mediastinum with left myocardium RI container

    LSCT 001 with ion chamber

    Apical portion

    Bifurcation

    Base of Lungs

    Apical portion

    Bifurcation

    Base of Lungs

    Dosimeter Hole

    Set Includes:1 chest phantom: life size torso with arm up position internal structures: bones simulated tumors at three lung areas apical portion of the lungs bifurcation of the trachea base of lungs dosimeter hole (1.3 cm / 0.5 in dia., on the central axis of the phantom)1 8-step linearity phantom 8 steps of 3 cm / 1.2 in dia. density samples are embedded1 adjustment base

    Size: chest phantom chest girth 93 cm/36.6 in height 45 cm/17.7 in weight 18 kg/40 lb linearity phantom diameter 20 cm/7.9 in height 10 cm/3.9 in

    Diagnostic Radiology

    fusionCT

    PET

    The set of RI container inserts can be set in the chest phantom in place of standard inserts allowing wider research applications including PET/CT fusion evaluation.The lungs of urethane foam can be worked easily to accommodate simulated nodules or other inserts.

    P.35

  • CT Torso Phantom CTU-41PH-4

    Kyoto Kagaku's best-selling CT head phantom.

    PH-3Angiographic CT Head Phantom ACS

    Removable jaws and tongue allow a variety of application for training and research.

    PH-47Dental Radiography Head Phantom

    17

    A one-piece anthropomorphic torso phantom with anatomical structures allows various CT approaches including helical scanning.

    Left anterior cerebral artery, left middle cerebral artery, cerebrum, mesencephalon, cerebellum, ventricles, eye balls, synthetic skull and cervical vertebrae (C1-C7).

    1.

    2.

    Contrast-enhanced left cerebral arteries are three dimensionally embedded in the brain. Diameters of arteries range from 0.5 to 4.0 mm / 0.02 in to 0.16 in.

    Features

    AnatomiesSynthetic bones with cartilage: artificial skull, vertebrae, clavicles, ribs, sternum, scapula, coxal bones, femursBrain with cerebral ventriclesEye ballsLungs with pulmonary vessels Trachea (up to the third bifurcations)Liver with portal and hepatic veinsKidneys, gallbladder, pancreas, spleen, aorta, cava, ureter, urinary bladder, prostate, rectum, sigmoid colon and ascites

    Optional Parts: 41363-030 storage case

    Set Includes:1 CT Torso Phantom: life size, male

    Virtual Bronchoscopic View

    Specifications

    Size:phantom height: 100 cm/39.4 inphantom weight: 45 kg/99 lbpacking size:  106 x 58 x 62 cm 42 x 23 x 24 inpacking weight: 52 kg/114 lb

    41309-100

    Anatomies

    CT Type

    41309-200Angio Type

    Set Includes:1 head phantom1 storage case

    Specifications

    Size:Packing size:49 x 33 x 35 cm19.3 x 13 x 13.8 inpacking weight:9.5 kg/21 lb

    Production Supervision:Akitoshi Katsumata, D.D.S., Ph.D.ProfessorAsahi University, School of Dentistry

    1.

    2.

    3.

    4.

    Each tooth is individually modeled and has a three-layer structure of enamel, dentin and pulp cavity.Each hard tissue (enamel, dentin, cortical bone and cancellous bone) has a particular HU number and X-ray absorption rate.Jaws and tongue are detachable to allow access to the oral cavity, pharyngeal cavity and maxillary sinus. Censors, simulated lesions, or residue can be set in these cavities.Carotid arteries are prepared as lumens to accommodate simulated calcifications.

    Features

    Set Includes:1 main head unit 1 upper jaw (alveolar bone)1 lower jaw (alveolar bone)

    1 tongue 1 fixation base (including screws)1 tripod 1 storage case

    - Synthetic skull with nasal cavity, maxillary sinus, mandible alveolar, and maxillary alveolar; cervical vertebrae and hyoid bone, teeth with enamel, dentin and pulp cavity.- Tongue, oral cavity, pharyngeal cavity and carotid arteries

    Anatomies

    Specifications

    Diagnostic Radiology

    P.35

  • CT and ultrasound fusion experiments are possible with combination of the US-1 Echozy.

    PH-5CT Abdomen Phantom

    Rotational phantom to simulate double contrast gastrography.

    PH-19Rotation Stomach Phantom TMP-R

    Stomach phantom for double contrast gastrography.

    PH-18Stomach Phantom BMU-1

    Resourceful model for therapy planning for prostate cancer.

    PH-46CT Prostate Phantom

    18

    1. 2. 3. 4. 5.

    Rotation system to simulate the movement of patient.Life-size distended stomach with lesions modeled from real specimens.Barium can be poured in the stomach for imaging.Pathology includes early cancer and gastric ulcer.Sample model of lesions are included.

    Set Includes:1 abdomen phantom

    Set Includes:1 prostate phantom

    Size:phantom size: 25 x 18 x 28 cm 9.8 x 7.1 x 11 in

    Optional Parts:41363-050 storage case

    Set includes:1 stomach phantom1 rotation unit1 controller

    1 phantom holder1 model of lesions1 storage case

    SpecificationsSet includes:1 stomach phantom1 storage case

    Size:phantom size: 30 x 20 x 33 cm 11.8 x 7.9 x 13 inphantom weight: 16 kg 35.3 lb

    Specifications

    sagittal coronal

    axial

    lungs (no internal structure)heart (no internal structure)liverportal veingallbladder

    hepatic veinhepatic arterykidneyspancreasspleen

    aortaIVCspinal columnribs

    Anatomies

    Features1. 2. 3.

    Life-size distended stomach with lesions modeled from real specimens.Barium can be poured in the stomach for imaging.Pathology includes early cancer and gastric ulcer.

    Features

    Specifications

    Organs:prostate, urinal bladder with simulated internal fluid, seminal vesicles and rectum.Bones: L4, L5, pelvis and femurs (partial).

    Anatomies

    Size:35 cm H/13.8 in H

    Specifications

    Diagnostic Radiology

  • Dynamic Heart and Lung PhantomPH-48

    Anthropomorphic chest phantom for respiratory gating.

    PH-39Dynamic Thorax Phantom

    For evaluation and research in ECG gating cardiac and thoracic CT.

    PH-6BDynamic Cardiac CT Phantom MD-CT

    19

    The motion of diaphragm and tumor, and the realistic heart motions provide various solutions for clinical research.

    1.

    2.

    3.

    4.

    1. 2.

    3.

    4.5.

    The phantom represents movement of the heart, lungs and pulmonary nodule.The pulmonary nodule and diaphragm moves independently with the respiratory cycle. -Three dimensional movement of the pulmonary nodule (linearly and rotationally) -Motion disc represents respiratory movement of abdomen.The elastic heart represents systolic and diastolic motion. The coronary arteries including stenotic examples are shown. -The phantom can be connected to ECG for ECG gating.Simple operation with wireless tablet

    Features1. 2. 3.4.

    TLD can be inserted to simulate the nodule.Six preset respiratory patterns are prepared.Respiratory patterns can be modified and saved.Up to three different respiratory patterns can be run in sequence.

    Features

    Set Includes:1 drive unit1 nodule rotation unit1 diaphragm block1 chest phantom3 types of heart unit1 set of simulated tumors (15 types)1 tablet PC

    Specifications

    Synthetic bones of the chestHeart with coronary artery, diaphragm

    Anatomies

    heart rate: 30-120 times/minejection volume: 60, 70, 80, 90, 100mlef rate: 30%, 35%, 40%, 45%, 50%, 55%, 60%respiratory rate: 6-24 cycles/minlinear movement of nodule unit: 8-64mm / 0-1.5 inrotation range of nodule unit: 50-70 degrees

    Controllable Parameters:

    Controllable Parameters:

    Respiratory gating chest CTTumor tracking in radiotherapyECG gating cardiac CT

    Applications

    Pulmonary nodule, stenosis of coronary arteriesPathologies

    ECG-gated

    Non ECG-gated

    Set Includes:1 drive unit1 chest phantom1 mediastinum phantom with right pulmonary vessels1 nodule rotation unit1 diaphragm block1 set of simulated nodules1 controller1 storage case

    respiratory rate: 6-24 cycles/min.movement of diaphragm: 0-38 mm/0-1.5 inlinearly movement of nodule unit: 38-64mm/1.5-2.5 inrotation of nodule unit: 50-70 degrees

    Respiratory gating CT, dosimetry and radiation therapy. Evaluation Applications

    Specifications

    Dynamic Phantoms

    Beam pitch and image quality

    The heart phantom is made of human tissue substitute.Simulated coronary arteries including stenosis can be attached to the wall of the phantom heart.The phantom generates pulses that are synchronized with the cardiac movement for ECG gating.Controllable parameters include pulse rate, ejection volume and ejection fraction.Operation with the touch panel controller is simple and easy.

    Measurement of the left ventricle ejection fraction (EF)Image quality evaluation of coronary arteries

    Heart phantom: materials: polyurethane based resin HU value: approx.40 volume: ESV=approx.47.5ml

    Motion parameters: pulse rate: 30-120 beats/min ejection volume: 60-100 ml ejection fraction: 30-60%

    Set Includes:1 drive unit3 heart phantoms1 protective cover1 set of simulated coronary arteries 1 controller1 storage case

    Features

    Evaluation Applications

    Specifications

    P.35

  • Dosimetry and Radiotherapy

    A stable, high quality and shatter-free phantom for radiotherapy.

    PH-40/41/42Tough Phantom Series Therapy Body Phantom THRA-1

    PH-40Tough Water PhantomWD

    PH-41Tough Bone PhantomBE-T, BE-H, BE-N

    PH-42Tough Lung PhantomLP

    THRA-1 is an anthropomorphic, cross sectional dosimetry for therapeutic energy range.

    PH-37

    20

    Set Includes:1 torso phantom1 pair of breast phantom1 supporting frame1 storage case

    Size:phantom size: 90 cm/35.5 inslice thickness: 3 cm/1.2 in

    dosimeter holes: in lattice-like pattern of 3x3 cm/1.2 x 1.2 in

    Specifications

    Tough series phantoms can be ordered with cavities and plugs.Easy-to-work

    300 x 300 x 2 mm12 x 12 x 0.08 in300 x 300 x 3 mm12 x 12 x 0.12 in300 x 300 x 5 mm12 x 12 x 0.2 in300 x 300 x 10 mm12 x 12 x 0.4 in300 x 300 x 15 mm12 x 12 x 0.6 in300 x 300 x 20 mm12 x 12 x 0.8 in 300 x 300 x 25 mm12 x 12 x 1.0 in300 x 300 x 30 mm12 x 12 x 1.2 in300 x 300 x 40 mm12 x 12 x 1.6 in300 x 300 x 50 mm12 x 12 x 2.0 in400 x 400 x 2 mm16 x 16 x 0.08 in

    WD-3002

    WD-3003

    WD-3005

    WD-3010

    WD-3015

    WD-3020

    WD-3025

    WD-3030

    WD-3040

    WD-3050

    WD-4002

    400 x 400 x 3 mm16 x 16 x 0.12 in400 x 400 x 5 mm16 x 16 x 0.2 in400 x 400 x 10 mm16 x 16 x 0.4 in400 x 400 x 15 mm16 x 16 x 0.6 in400 x 400 x 20 mm16 x 16 x 0.8 in400 x 400 x 25 mm16 x 16 x 1.0 in400 x 400 x 30 mm16 x 16 x 1.2 in400 x 400 x 40 mm16 x 16 x 1.6 in400 x 400 x 50 mm16 x 16 x 2.0 in

    WD-4003

    WD-4005

    WD-4010

    WD-4015

    WD-4020

    WD-4025

    WD-4030

    WD-4040

    WD-4050

    Compact Bone200 x 200 x 5 mm / 8 x 8 x 0.2 inCompact Bone200 x 200 x 10 mm / 8 x 8 x 0.4 inCompact Bone200 x 200 x 20 mm / 8 x 8 x 0.8 inCortical Bone200 x 200 x 5 mm / 8 x 8 x 0.2 inCortical Bone 200 x 200 x 10 mm / 8 x 8 x 0.4 inCortical Bone200 x 200 x 20 mm / 8 x 8 x 0.8 inInner Bone 200 x 200 x 5 mm / 8 x 8 x 0.2 inInner Bone 200 x 200 x 10 mm / 8 x 8 x 0.4 inInner Bone 200 x 200 x 20 mm / 8 x 8 x 0.8 in

    BE-T-05

    BE-T-10

    BE-T-20

    BE-H-05

    BE-H-10

    BE-H-20

    BE-N-05

    BE-N-10

    BE-N-20

    Cortical Bone300 x 300 x 5 mm / 12 x 12 x 0.2 inCortical Bone300 x 300 x 10 mm / 12 x 12 x 0.4 inCortical Bone300 x 300 x 20 mm / 12 x 12 x 0.8 inInner Bone300 x 300 x 5 mm / 12 x 12 x 0.2 in Inner Bone300 x 300 x 10 mm / 12 x 12 x 0.4 inInner Bone300 x 300 x 20 mm / 12 x 12 x 0.8 in

    BE-H-05

    BE-H-10

    BE-H-20

    BE-N-05

    BE-N-10

    BE-N-20

    LP-3010 300 x 300 x 10 mm / 12 x 12 x 0.4 inLP-3020 300 x 300 x 20 mm / 12 x 12 x 0.8 inLP-3030 300 x 300 x 30 mm / 12 x 12 x 1.2 inLP-3050 300 x 300 x 50 mm / 12 x 12 x 2.0 in

    * Slice thickness and dosimeter holes can also be custom ordered.

    Stable QualityExcellent homogeneity is realized by high standard of production and quality inspection.

  • MRI / Nuclear Medicine21

    MRI Head Phantom NHPH-33

    Life-size head phantom to assess uniformity.

    Set Includes:1 head phantom1 nickel chloride solution1 storage case

    Specifications

    Conforming to JIS Z 4924

    MRI Quality Assurance Phantom JMRPH-32

    SN ratio, uniformity, slice thickness, spatial resolution, geometric distortion can be evaluated.

    Set Includes:1 phantom1 nickel chloride solution1 storage case

    Size:22 dia. x 13 cm / 8.7 dia. x 5.1 in

    Specifications

    Conforming to JIS Z 4924

    Set Includes:1 phantom unit A1 phantom unit B1 set of nickel chloride solution

    Size:22 dia. x 14cm / 8.7 dia. x 5.5 in

    Specifications

    This QA phantom for MRI allows to evaluate the slice thickness, spatial resolution, uniformity and geometric distortion as well as contrast. Complies with NEMA standards.

    PH-31MRI Quality Assurance Phantom MHR

    Simulate life-size head images in nuclear medicine and MRI.

    PH-34MRI/NM Head Phantom BHC

    Specifications

    Set Includes:1 head phantom2 simulated tumor (1 cm dia., 2 cm dia. each) (0.4 in dia., 0.79 in dia. each)1 nickel chloride solution1 storage case

    Size:33 cm height12.9 in height

    This brain phantom of the striatal region with replicated skull densities of a male and female is useful for uptake ratio calibrations and studying the I-123 DaTSCAN scatter correction techniques.

    Brain Phantom IB-20 advanced

    Size:inside dimensions13.5 x 18.5 cm/5.3 x 7.3 inheight8.8 cm/3.5 in

    Specifications

    scatter correction technique

  • MRI / Nuclear Medicine 22

    For the study of high radio accumulation interference in the liver with the myocardial SPECT images.

    PH-24Myocardial Phantom

    Size:32 x 22 x 31 cm12.6 x 8.7 x 12.2 in

    SpecificationsFeaturesAllows the study of RI liver intake and its effect on the myocardial SPECT.Cold defect can be set in the left cardiac muscle. Background can be set individually in lung field, mediastinum and right ventricle.

    1.

    2. 3.

    Volumetric measurement phantom for PET/SPECT

    PH-29ECT Hot Cold Phantom SP-6

    Size:21 dia. x 16 cm8.3 dia. x 6.3 in

    Set Includes:1 outer phantom5 sphere phantoms1 storage case

    SpecificationsFeaturesFive sphere containers with different sizes can be filled with RI solution.Volume of sphere phantoms are:50 mm/2 in (100%), 80%, 60%, 40% and 20%.

    1.

    2.

    For daily quality control in SPECT and PET imaging

    PH-28SPECT QA Phantom JSP

    Set Includes:1 outer phantom1 line source phantom1 cold spot phantom1 hot spot phantom

    Size:22dia. x 22 cm8.7dia. x 8.2 in

    1 dose linearity phantom1 geometric distortion phantom1 phantom holder1 storage case

    Specifications

    PH-30SPECT QA Phantom JS-10

    Set Includes:1 outer phantom1 slice thickness phantom1 spatial resolution phantom1 bar phantom

    1 hot/cold spot phantom1 scatter radiation phantom1 phantom holder1 storage case

    SpecificationsFive variations of myocardial volume.

    PH-25Myocardial Phantom HL-D

    Set Includes:1 chest phantom5 mediastinum inserts5 myocardial containers1 storage case

    SpecificationsFeaturesMyocardium, liver and gall bladder can be separately filled with RI solution.Close-to-human chest anatomy allows effective attenuation and scatter correction.Five variations of myocardial containers with different shape and volume

    1.

    2. 3.

    Conforming to JIS Z 4922

  • CT Image Quality Control / AEC

    Multi Slice CT Phantom MHTPH-9

    Digital imaging phantom compatible with various 3D imaging methods

    PH-453D Digital Image Phantom ODA

    23

    The phantom can be used for features of CT evaluation such as high and low contrast resolutions, feed direction and CTDI.

    CT-AEC PhantomsPH-7

    Four types of phantoms designed to evaluate CT-AEC performance

    Set Includes:1 low contrast phantom1 high contrast phantom1 elliptical absorber1 low contrast phantom with CTDI1 micro disc phantom1 angle adjustment holder

    Optional parts: 41334-110 sliding phantom holder

    Specifications

    Size:3D Sphere Phantom20 cm dia. / 7.9 in dia.

    3D Angio Phantom10 x 10 x 10 cm / 4.0 x 4.0 x 4.0 in

    3D Low Contrast Phantom10 x 10 x 10 cm / 4.0 x 4.0 x 4.0 in

    Specifications

    High Contrast PhantomLow Contrast Phantom

    Non-aqueous/ Easy Set-upenables liquid-free evaluation session.The phantom is designed to allow evaluation in volume scanning.

    1.

    2.

    Features

    Low contrast resolution evaluation in abdominal area

    High contrast resolution evaluation in lung area

    Elliptical AbsorberLow Contrast andCTDI Phantom

    SSPz evaluation in helical scanningMicro Disc Phantom

    Digital image evaluation phantom applicable to 3D imaging such as cone beam CT with FPD, tomosynthesis. Angiographic image and low contrast resolution can be evaluated on axial, coronal, sagittal and oblique sections as well as 3D DSA and CT. The phantom can be used either as a sphere phantom or a cylinder phantom.

    Production supervision: Professor Nobuhiro Oda, Kyoto College of Medical Science.

    3D Sphere Phantom

    3D Angio Phantom

    3D Low Contrast Phantom

    3D Angio Phantom or 3D Low Contrast Phantom.

    3D Sphere Phantom 3D Column Phantom

    3D Sphere Phantom 3D Angio Phantom

    3D Column Phantom3D Low Contrast Phantom

    Low contrast spherical targets with 5 sizes and 3 step HU numbers are three dimensionally placed in the cube.

    Assemble the cube phantom and the sphere phantom and then cover it with 3D column phantom.

    Sphere shape phantom is to house 3D Angio Phantom or 3D Low Contrast Phantom.

    Simulated vessels enclosing resin containing iodine with 4-step density are three dimensionally placed at 4 sites on the phantom.

    ① ②

    Image quality can be evaluated by noise and S.D. on the phantom section images.Four types of CT-AEC Phantoms:Cone Phantom: evaluates performance of AEC for different patient sizes and gradual size changes in size along the axis.Elliptical Cone Phantom: in combination with the Cone phantom, facilitates evaluation of XY AEC.Variable-XY Phantom: evaluates performance of XY AEC as cross section changes from circular to elliptical.Stepped Phantom: evaluates the performance of the AEC to sudden changes in patient's cross section.

    Cone (Apollo)Phantom

    Variable XYPhantom

    Stepped Cylinder Phantom

    Elliptical ConePhantom

    35 dia. x 32 cm13.8 dia. x 12.6 in

    X:Y= 1:1.5Sectional area equal to that of the cone phantom

    41339-010 Cone (Apollo Phantom) 41339-020 Elliptical Cone Phantom41339-030 Variable XY Phantom41339-040 Stepped Cylinder Phantom*each phantom can be ordered individually

    X-Y ratio varies continuously from 1.0 to 2.5.Sectional area is kept to be equal to 20 cm/8 in dia.

    Specifications

    Diameter difference≒ 5 cm/2 in

    P.35

  • CT Image Quality Control / AEC

    PH-13

    PH-12

    Digital Mammographic Phantom NCCE

    A QA phantom for mammography with 10 s teps of background densities.

    Mammographic Step Phantom AGH-D210F

    24

    12 features of evaluation to cover recommendation of Japanese Committee

    PH-22CT QA Phantom CT-200B

    Six features of daily evaluation are possible.

    PH-21CT QA Phantom JCT

    Set Includes:1 breast phantom1 storage caseSize:12.5 x 18.5 x 5.5 cm4.9 x 7.3 x 2.2 in

    Specifications

    Set Includes:1 CT QA phantom1 storage caseSize:20 dia. x 20 cm7.9 dia. x 7.9 in

    Specifications

    Set Includes:2 phantom units (10 steps)Size:11.5 x 7 x 1.5 cm each4.5 x 2.8 x 0.6 in each

    Specifications

    Set Includes:1 set of QA phantoms1 storage case

    Specifications

    FeaturesOuter shape of the phantom simulates a compressed breast of D shape.Features of evaluation include: contrast resolution, frequency enhancement, noise and contrast transfer function.Targets includes simulated microcalcifications, nylon fibrils, acrylic disks, an aluminum ring, Teflon disks, a Teflon ruler(slope) and a resolution test chart.

    Possible valuation:Noise, contrast scale, spatial resolution, slice thickness, high contrast resolution and low contrast resolution.

    A simulated tumor of 0.5 mm thickness and 200μm simulated calcifications are embedded in each phantom block of 30 x 15mm.Recommended by The Central Committee on Quality Control of Mammographic Screening of Japan.

    Possible evaluation includes: uniformity, noise and contrast-scale, PSF, LSF, MTF, slice thickness, high contrast resolution, low contrast resolution, radiation dose, artifact, edge effect, absorbed dose and linearity.

    1.

    2.

    3.

    FeaturesSimulated airways and vessels are embedded in the lung tissue substitute.Layers of different materials allow study in axial variation such as slice thickness effect.Image distortion can be assessed.

    1.

    2.

    3.

    FeaturesOn each plate phantom of 5 mm thickness, five slits of 5 mm length are made to represent vessels.Nine variations of vessel width are prepared: 0.3, 0.4, b0.6, 0.7, 0.8, 1.0, 1.2, 1.5 mm.(0.012, 0.016, 0.024, 0.028, 0.032, 0.039, 0.047, 0.059 in)

    1.

    2.

    conforming to JIS Z 4923

    The phantom with simulated vessels to evaluate spatial resolution in CT.

    PH-9-2Ladder Phantom

    CT Lung Phantom

    Set Includes:1 CT lung phantom simulated airways 3-14 mm dia. simulated vessels 2-14 mm dia.1 storage caseSize:200 dia. x 300 mm/ 7.9 dia. x 11.9 in

    Specifications

    Set Includes:1 outer phantom9 ladder phantoms1 storage case

    Specifications

    11 features of CT evaluation are possible by using interchangeable measurement units. Conforming to second recommendation of Japanese Committee for Evaluating Performance of CT Scanners.

    Used by QIBA COPD/Asthma Committee, for longitudinal sites comparison study.

  • CT Image Quality Control / AEC

    BMD Chart Phantom UHAPH-10

    Water Body Phantom represents human chest and abdomen to serve as radiation absorber and scatterer.

    PH-17Water Body Phantom WAC

    25

    XUR is a series of human tissue substitute phantoms co-developed with Japan Atomic Energy Agency.

    PH-15Tissue Substitute Phantoms XUR

    Bone Mineral Density chart for microdensitometry (MD) method.

    Contrast Detail PhantomPH-16

    Image evaluation in plain X-ray

    Acrylic Phantom XACPH-14

    Slab phantoms for radiation absorption and scattering measurement.

    Specifications

    Features

    Set Includes:1 chart phantom1 storage case

    SpecificationsSet Includes:1 body phantom1 storage case

    Size:30 x 20 x 45 cm11.8 x 7.9 x 17.7 in

    Size:3 x 21 x 1.5 cm (consists of 21 blocks of 3 x 1 x 1.5 cm each.)1.2 x 8.3 x 0.6 in (consists of 21 blocks of 8.3 x 0.4 x 0.6 in each)

    1. 2.

    Specifications

    FeaturesFour types of phantoms with different sizes and target types. Rod 15: 15 x 15 rods of height range from 1.0 to 8.0 mm (0.4 to 3.1 in) Hole 15: 15 x 15 holes of depth range from 1.0 to 8.0 mm (0.4 to 3.1 in) Rod 10: 10 x 10 rods of height range from 1.0 to 5.5 mm (0.4 to 2.2 in) Hole 10: 10 x 10 holes of depth range from 1.0 to 5.5 mm (0.4 to 2.2 in)

    The phantoms developed based on Reference Man data of ICRP publication 23 and has close-to-human specific gravity and attenuation rate in diagnostic energy range.

    Size:Rod 15 and Hole 15: 24.5 x 24.5 cm each(9.6 x 9.6 in each)Rod 10 and Hole 10:17 x 17 cm each(6.7 x 6.7 in each)

    Confirming to JIS Z 4915

    41450-010 300 x 300 x 2mm/12 x 12 x 0.08 in41450-020 300 x 300 x 5mm/12 x 12 x 0.2 in41450-030 300 x 300 x 10mm/12 x 12 x 0.4 in41450-040 300 x 300 x 20mm/12 x 12 x 0.8 in41450-050 300 x 300 x 30mm/12 x 12 x 1.2 in41450-060 300 x 300 x 50mm/12 x 12 x 2.0 in

    XAC-01 41430-000 30 x 30 x 0.1 cm/11.8 x 11.8 x 0.04 in XAC-02 41431-000 30 x 30 x 0.2 cm/11.8 x 11.8 x 0.08 inXAC-03 41432-000 30 x 30 x 0.3 cm/11.8 x 11.8 x 0.12 inXAC-04 41433-000 30 x 30 x 0.4 cm/11.8 x 11.8 x 0.16 inXAC-05 41434-000 30 x 30 x 0.5 cm/11.8 x 11.8 x 0.2 inXAC-08 41435-000 30 x 30 x 0.8 cm/11.8 x 11.8 x 0.3 inXAC-1 41436-000 30 x 30 x 1 cm/11.8 x 11.8 x 0.4 inXAC-2 41437-000 30 x 30 x 2 cm/11.8 x 11.8 x 0.8 in XAC-3 41438-000 30 x 30 x 3 cm/11.8 x 11.8 x 1.2 inXAC-4 41439-000 30 x 30 x 4 cm/11.8 x 11.8 x 1.6 inXAC-5 41440-000 30 x 30 x 5 cm/11.8 x 11.8 x 2.0 inXAC-8 41441-000 30 x 30 x 8 cm/11.8 x 11.8 x 3.1 inXAC-10 41442-000 30 x 30 x 10 cm/11.8 x 11.8 x 3.9 in

    SZ-207 Soft TissueSZ-208 MuscleSZ-49 AdiposeSZ-160 CartilageSZ-220 Muscle and AdiposeMaterials: polyurethane

    *Specify the SZ type numbers and size codes at the time of your order.

    21 steps with different hydroxyapatite content.Steps range from 0 to 400 mg/cm , with 20mg/cm difference each.

    P.35, P.37

  • US-8FAST/Acute Abdomen Phantom "FAST/ER FAN"

    26

    US-5Pediatric FAST/Acute Abdomen Phantom

    Ultrasound Phantoms

    The world's first pediatric ultrasound torso phantomBest tool for workshop in emergency ultrasound.FAST/ER FAN provides simulated training in FAST (Focused Assessment with Sonography for Trauma); an ultrasound examination directed at identifying the presence of free intraperitoneal or pericardial fluid in traumatic patients.

    Pediatric FAST/Acute Abdomen Phantom provides opportunities of hands on training in ultrasound that is a crucial modality for radiosensitive children.

    An innovative phantom for repetitive training of FAST as an adjunct to the ATLS primary survey.Pathologies include cholecystitis, aortic aneurysm and lesion on the colon.

    1.

    2.

    Features

    -Internal hemorrhage at perihepatic, perisplenic, pelvis and pericardium area.

    -Diverticulitis, inflammation of the gallbladder, aneurysm and appendicitis.

    Pathologies

    Production supervision:Junji Machi, MD, PhDUniversity of Hawaiiat Manoa and Kuakini Medical Center

    Cardiac Tamponade Right Upper Abdominal Bleeding Left Upper Abdominal Bleeding

    Pelvic Bleeding

    Abdominal Aortic Aneurysm

    Pleural Bleeding Perihepatic Bleeding

    Set Includes:1 ultrasound phantom1 tutorial manual (DVD)

    Size: 61 x 30 x 30 cm 24.4 x 12 x 12 in

    Weight: 31 kg 68.2 lb

    Specifications

    Product SupervisionShunsuke Nosaka, MD, PhDDirector of RadiologyNational Medical Center for Children and Mothers

    - Internal hemorrhage at perihepatic, perisplenic, pelvis, and pericardium area- Bowel intussusception, appendicitis and biliary dilatation

    Pathologies

    The phantom includes life-size 2-year-old thoracoabdominal organs, a bone structure, free fluid to learn FAST procedures and pathologies that are commonly seen in pediatrics.With this phantom, trainees can acquire skills in basics of pediatric abdominal ultrasound.

    Size:41 x 15 x 15 cm16 x 6 x 6 in

    Set Includes:1 ultrasound phantom 1 storage case1 tutorial manual (DVD)

    Appendicitis

    Pleural Hemorrhage Hydronephrosis

    Bowel Intussusception

    Features

    Specifications

    1.

    2.

  • Fetus Ultrasound Examination Phantom"SPACE FAN-ST"

    US-7α

    Training in ultrasound breast cancer screening with detailed anatomy.

    US-6Breast Ultrasound Examination Phantom"BREAST FAN"

    27

    Fetus ultrasound phantom with a full skeletal structure.

    Ultrasound Phantoms

    Product SupervisionTokiko Endo, MD, PhDDirector of Department of Advanced Diagnosis, Clinical Research Center, National Hospital Organization Nagoya Medical CenterDirector of Department of Radiology, National Hospital Organization Nagoya Medical Center

    Training Skills

    Features

    BREASTFAN is a unique phantom for training in basic breast ultrasound examination. Simulated targets with different echogenicities are embedded in the mammary gland.

    SPACEFAN-ST provides high quality training for second trimester screening in pregnancy. A 23-week fetus is included with detailed anatomies which are essential for the assessment at the period.

    -Skills to scan full area of breast systematically-Visualization of key anatomical landmarks-Tracking galactophore-Visualization and differentiation of typical pathologies-Localization and measurement of cyst and tumors

    Anatomies Subcutaneous adipose, mammary gland, galactophore, Cooper's ligament, retromammary adipose, costae, clavicle, pectoralis major, lung and lymph nodes at axilla.

    PathologiesCyst, mammary ductal ectasia, malignant tumor, benign tumor

    Cyst Malignant Tumor

    1.

    2.

    State-of-the-art breast phantom with ultrasound anatomySkills required for ultrasound breast screening can be greatly advanced with practice.

    1.2.

    Set Includes:1 breast phantom1 storage case1 tutorial manual (DVD)

    phantom size:19 x 22 x 7 cm, 3.6 kg7.6 x 8.8 x 2.8 in, 7.9 lb

    packing size:35 x 36 x 12 cm, 6 kg14 x 14.4 x 4.7 in, 13.2 lb

    SpecificationsUVBrain with Septum Lucidum,

    Lateral Ventricles and Cerebellum

    Features

    Anatomies

    Specifications

    -Fetal size assessment: BPD, AD, AC and FL-Measurement of amniotic fluid volume-Determination of fetus presentation (cephalic or breech)-Assessment of each body part -Head: skull and brain -Spine and limbs -Cardiac chambers, blood vessels and lung-Assessment of umbilical cord and placenta position-Determination of sex (This phantom represents a male fetus)

    Training Skills

    Set Includes:1 mother body torso1 ultrasound pregnant uterus phantom1 fetus demonstration model1 storage case1 tutorial manual (DVD)

    Size:40 x 29 x 22 cm16 x 11.6 x 8.8 in

    Uterus: amniotic fluid, placenta, umbilical cord, and a 23-weeks fetus (26 cm/10.2 in)Fetus: skeletal structure, brain with septum lucidum, lateral ventricles and cerebellum, heart with four chambers, lungs, spleen, kidneys, aorta, UV, UA, and the external genital

    SPACEFAN-ST provides high quality training for routine second trimester screening. The oval shape phantom abdomen can be set in four different positions.

    The oval shape phantom abdomencan be set in four different positions.

  • US-3Abdominal Intraoperative & Laparoscopic Ultrasound Phantom"IOUS FAN"Innovative phantom simulating abdominal open intraoperative and laparoscopic ultrasound examination.

    Unique high-fidelity ultrasound phantoms that facilitate effective training in abdominal ultrasound scanning with your own clinical devices.

    28

    US-1BUltrasound Examination Training Phantom "ABDFAN"US-1Ultrasound Examination Training Phantom "ECHOZY"

    Ultrasound Phantoms

    Specifications

    1.2.

    3.

    1.

    2.

    Junji Machi, MD, PhDUniversity of Hawaii at Manoa and Kuakini Medical Center

    Production supervision:

    ABDFAN ECHOZY

    Dr. Hitoshi Asai, DirectorOsaka Kyoiku University, Health Administration CenterDr. Shigeru NakamuraNagayoshi General Hospital, Clinical Examination Department

    Production supervision:

    Training Phantom with no pathology

    Simulated lesions are embedded.

    Detailed hepatobiliary, pancreatic and other abdominal anatomy;eight Couinaud's hepatic segments can be localized.ABDFAN has various simulated lesions to provide wider training variety.

    Features

    Anatomies

    Training SkillsBasics of abdominal sonography: Cross sections and sonographic anatomy Sonographic demonstration of each individual organ Localization of hepatic Couinaud's segments

    - liver (segmental anatomy, portal and hepatic venous systems, ligamentum teres and ligamentum venosum)- biliary tract (gallbladder, cystic duct, intrahepatic and extrahepatic bile ducts)- pancreas (pancreatic duct)- spleen / kidneys - detailed vascular structures (aorta, vena cava, celiac artery and its branches, portal vein and its branches, superior mesenteric vessels, renal vessels, etc.)

    -hepatic lesions (cystic and solid)-gallbladder and bile duct stones-pancreatic tumors (one invading the portal vein)

    -splenic lesions-both kidney lesions-left adrenal tumor

    anterior view

    Simulated cysts 1 cm / 0.4 inHypoechoic 1 cm / 0.4 inSimulated tumors 1 cm / 0.4 in

    Simulated tumors with double edge 2 cm / 0.8 in

    posterior view

    Simulated lesions in liver, pancreas, kidney, spleen, gallbladder

    Pathologies *ABDFAN only

    Liver, Hepatic VeinPancreas

    GallstonePancreatic Head

    -Abdominal intraoperative ultrasound examination-Laparoscopic ultrasound examination

    Anatomies- liver (segmental anatomy, portal and hepatic venous systems, ligamentum teres and ligamentum venosum)- biliary tract (gallbladder, cystic duct, intrahepatic and extrahepatic bile ducts)- pancreas (pancreatic duct)- spleen / kidneys - detailed vascular structures (aorta, vena cava, celiac artery and its branches, portal vein and its branches, superior mesenteric vessels, renal vessels, etc.)

    Training Skills

    Features

    Product SupervisionJunji Machi, MD,PhDUniversity of Hawaii at Manoa and Kuakini Medical Center

    Soft phantom materials allow realistic probe manipulation.Various simulated lesions including biliary stones and cysts, solid tumors (hypoechoic, hyperechoic and target-appearance) in the liver, pancreas, spleen and kidneys.Detachable stomach and duodenum allows various scanning methods of the bile duct and pancreas.

    Laparoscopic Ultrasound

    Size:phantom size:30x38x17.5 cm, 5.8 kg12x15.2x7 in, 12.8 lb

    packing size:47x42x25 cm, 9 kg18.8x16.8x10 in, 19.8 lb

    Set Includes:1 upper abdomen ultrasound phantom1 stomach ultrasound phantom1 phantom container1 tutorial manual (DVD)

  • Ultrasound Guided Breast Biopsy PhantomUS-9

    Provides training in hands-eye coordination and basic skills in ultrasound-guided venous access.

    11347-210Introductory Ultrasound Training Block"REAL VESSEL"

    29

    Provides step by training in ultrasound guided breast biopsy.

    Ultrasound Quality Assurance PhantomsUS-2

    Durable and stable. Ensure highly detailed images to enable reliable breast cancer examinations.

    US-4Breast Ultrasound QA Phantom

    Ultrasound Phantoms

    Features

    Features

    Training Skills

    Specifications

    Common Specifications

    -Hand-eye coordination in ultrasound biopsy-Localization of targets under ultrasound guidance-Sampling of target

    1.

    2.

    3. 4.

    5.6.

    1.

    2.3. 4. 1.

    2.

    Size:16dia. x 8 cm6.3dia. x 3.15 in

    Set Includes:Duo Set: 11387-000 (transparent + opaque type) Transparent Set: 11387-100 (1 pair of transparent type) Opaque Set: 11387-200 (1 pair of opaque type)

    Fine Needle Aspiration Biopsy (FNAB), Core Needle Biopsy (CNB) and Mammotome Biopsy can be performed under ultrasound guidance. Tissue of the breast phantom represents softness and resistance of the mammary gland.Targets are colored to confirm successful sampling.Targets are embedded in three levels to allow training in needle access with different angles and depth.Transparent and opaque type phantoms provide various level of training.An inexpensive and disposable training tool that provides many numbers of trials.

    1. 2 simulated vessel lines: straight and curve.2. Lines have slope to represent vessels with different depth.3. Vessel wall yields under pressure of a needle tip.

    -Visualization and localization of the vessels.-Transducer manipulation.-Basics for ultrasound-guided vascular access.

    Set Includes:REAL VESSEL Introductory ultrasound training block (a set of 2)

    Features

    Training Skills

    Specifications

    Production supervision: Hiroshi Natori, Ph.D. Professor Sapporo Medical University

    Useful both for daily assessment and further research.The phantom is designed to allow scanning from all four side walls.

    N-365 Multipurpose Phantom

    String target Cyst target

    Close range resolution (dead zone)

    Axial resolution

    Lateral resolution

    Gray scale

    1 2 3 4 5 10 10 10 10 10 10 10 10

    10

    1

    1020

    20

    7012

    .512

    .512

    .512

    .512

    .512

    .5

    4515

    2020

    3050

    50

    50

    30

    20

    30

    15

    15

    10

    1 2 3 4

    - T1

    - T2

    - T1

    - T0

    - T1

    - T2

    - T3

    Set Includes:1 phantom each1 carrying case eachphantom size: 19 x 22 x 7 cm, 3.6 kg7.6 x 8.8 x 2.8 in, 7.9 lb

    packing size:35 x 36 x 24 cm, 6 kg14 x 14.4 x 9.6 in, 13.2 lbSonic velocity: 1432m/sec at 25 degrees C

    Acoustic impedance: 1.38 rayl at 25 degrees CAttenuation rate: 0.57 dB/cm MHz at 25 degrees C

    N-060 QA Phantom/N-255 Cyst Phantom/N-211 String PhantomVarieties:

    Set Includes:1 mass targets block1 dot targets block1 thermometer1 storage case

    Four kinds of targets, gray scale, cyst targets, dot targets and 45 degrees line target at 2 different depth, 10mm (0.4 in) and 20mm (0.8 in).Background of each phantom block is of different attenuation rate and speed of sound.Detailed spatial resolution as minute as 0.5mm (0.02 in) can be assessed.Comes with a thermometer to measure inner temperature of the phantom.

    Size:mass targets block phantom size: 18 x 7.5 x 11 cm, 1.3 kg7.2 x 3 x 4.4 in, 2.9 lbdot targets block phantom size: 13.5 x 7.5 x 11 cm, 1.0kg5.4 x 3 x 4.4 in, 2.2 lb

    Features

    Specifications

    Product supervision:Japan Association of Breast and Thyroid Sonology,Quality Assurance Committee Working Team.Recommendation from:Japan Radiology Society, Imaging CommitteeBreast Imaging Group

    P.35P.35

  • Gehirn Phantom IB-20 voran

    -Komponenten für Radioisotope

    MRI QA PhantomMR-QA-Phantom

    Multilingual index 30

    Produits nouveaux

    Français

    Deutsch

    PH-50 Fantôme anatomique du nourrissonPH-1C Fantôme Thorax Pédiatric

    GGO tumeur FantômePH-49 Fantôme CT ColonographiePH-51 Simulateur d'examen fluoroscopique lombaireM43E Simulateur de ponction lombaire pour UltrasonUS-10 Fantôme Ultrason Pelvien FémininUS-11 Fantôme Scrotal pour UltrasonUS-13

    040506070808091011Fantôme de Formation Ultrason Pédiatric de la Hanche

    Médecine Nucléaire/IRM

    PH-33 Fantôme IRM tête Réf.HNPH-34 Fantôme Tête pour IRM

    PH-24 Fantôme MyocardePH-25 Fantôme cardiaque Réf.HL-DPH-29 Fantôme ECT "HOT/COLD" Réf. SP-6PH-28 Fantôme SOECT QA Réf. JPCPH-30 Fantôme SPECT QA Réf. JS.10

    Cerveau Fantôme IB-20 avança

    PH-32 Fantôme IRM QA Réf.JMRPH-31

    2121

    2222222222

    21

    2121Fantôme IRM d'Assurance Qualité

    Contrôle Qualité-CT, Radiologie, MammographiePH-9 Fantôme CT Multi-CoupesPH-45 Fantôme d'Image NumériquePH-7 Fantômes CT pour le Contrôle de l'Exposition Automatique

    "CT-AEC Phantoms" PH-13 Fantôme de Mammo Numérique Réf.NCCEPH-12 Fantôme échelle de contrast Mammo Réf.AGH-D210FPH-22 Fantôme CT QA Réf.CT-200BPH-21 Fantôme CT QA Réf. JCT

    Fantôme CT PoumonPH-9-2 Fantôme de contrastPH-10 Fantôme de densitométrie osseuse Réf.UHAPH-16 Fantôme contrast/détailPH-17 Fantôme corps Réf.WACPH-15 Substitut de tissu Phantoms XURPH-14

    232323

    2424242424242525252525Fantôme de plaques acrylique Réf.XAC

    Radiologie PH-2 Fantôme anatomique EntierPH-2B Fantôme CT anatomique Entier41350 -000-11 Fantôme avec Fracture de l' Avant-Bras / Main

    Modèle PH-2/2B avec Pathologies et Lésions AditionnellesPH-2C Fantôme Pédiatric anatomique entier

    Fantôme Pédiaric avec Fracture OsseusePH-1 Fantôme Thorax Polyvalent "LUNGMAN"

    PH-8 Fantôme Pulmonaire CT de Dépistage de CancerPH-4 Fantôme Thorax CTPH-3 Fantôme Tête d'Angiographie CTPH-47 Fantôme Tête de Radiographie DentairePH-5 Fantôme Abdomen CTPH-19 Fantôme dynamique estomac Réf.TMP-RPH-46 Fantôme Prostate CT PH-18 Fantôme estomac Réf.BMU-1

    121213

    13141415

    1617171718181818

    16Pièces de rechange pour PH-1-Plaques Thorax -étui-Simulation de Tumeurs-Ordre personnalisé Simulation de Tumeurs-Composants pour Radioisotopes

    Plaques additionnelles pour PH-2/2B 13

    Fantômes DynamiquesPH-48 Fantôme Dynamique Cœur et PoumonPH-39 Fantôme Dynamique ThoraxPH-6B

    191919Fantôme Dynamique Cardiac de CT PH-6

    Dosimétrie et Radiothérapie PH-40

    Plaques TE avec cavités pour Chambre d'IonisationPH-41PH-42PH-37

    20

    20

    040506070808091011

    2121

    2222222222

    21

    2121

    121213

    13141415

    1617171718181818

    16

    13

    191919

    20

    20

    Fantôme de Radiothérapie

    Neue ProduktePH-50 Röntgen Phantom NeugeborenesPH-1C Pädiatrisches Thorax Phantom

    GGO Tumore PhantomPH-49 CT Colonographie PhantomPH-51 LWS Fluoroskopie Training PhantomM43E Ultraschall kompatibler LWS Punktion / Epidural Simulator US-10 Fantôme Ultrason Pelvien FémininUS-11 Scrotum Ultraschall PhantomUS-13 Kinderhüften Sonographie Training Phantom

    Dynamische PhantomePH-48 Dynamisches Herz/Lungen PhantomPH-39 Dynamisches Thorax PhantomPH-6B Dynamisches Cardiac-CT Phantom

    Diagnostische RadiologiePH-2 Ganzkörper PhantomPH-2B CT Ganzkörper Phantom41350 -000-11 Fantôme avec Fracture de l' Avant-Bras / Main

    PH-2/2B mit zusätzlichen Läsionen und Pathologien PH-2C Pädiatrisches Ganzkörper Phantom

    Pädiatrisches Phantom mit KnochenbrüchenPH-1 Mehrzweck Thorax Phantom "LUNGMAN"

    PH-8 Lungenkrebs Screening CT PhantomPH-4 CT Torso PhantomPH-3 Angiographie CT Schädel PhantomPH-47 Dental Radiographie Schädel PhantomPH-5 CT Abdomen PhantomPH-19 Dynamisches Magen-PhantomPH-46 CT Prostata PhantomPH-18 Magen - Phantom BMU-1

    Ersatzteilliste PH-1-Chest Plates -Tragetasche-Simulierte Tumore-Kundenspezifischer Auftrag Simulierte Tumore

    Dosimetrie und TherapiePH-40

    TOUGH Phantom SeriePH-41PH-42PH-37 Therapie Körper Phantom

    Nuklearmedizin/MR

    PH-33 MR-Kopf-PhantomPH-34 Schädel Phantom for MRI

    PH-24 Myocard PhantomPH-25 Myocardial Phantom HL-DPH-29 ECT Hot Cold Phantom SP-6PH-28 SPECT QA Phantom JPCPH-30 SPECT QA Phantom JS-10

    PH-32PH-31

    Ersatzteilliste PH-2/2B

    Echographique US-5 Fantôme Abdominal "FAST/Acute" US-8 Fantôme Abdominal "FAST/Acute" Pédiatric US-7α Fantôme d'examen du Fœtus par UltrasonUS-6 Fantôme Ultrason d'Examen Mammaire "BREASTFAN"US-3 Fantôme Ultrason Abdominal Peropératoire & Coelioscopique

    "IOUSFAN"US-1B Fantôme de formation à l'Examen Echographique "ABDFAN" US-1 Fantôme de formation à l'Examen Echographique "ECHOZY"US-9 Fantôme de biopsie MammaireUS-2 Fantôme Ultrason d'Assurance Qualité Multi-Usages11347 -210 Bloc simulateur du système veineux par Ultrason "Real Vessel"US-4

    26262727

    28

    282829292929

    30-3435

    Fantôme Mammaire d'Assurance Qualité en Echographie

    Index multilinguePublication Références

  • Fantoma de cerebro IB-20

    Lista de componentes/partes de PH-2/2B

    31 Multilingual index

    Calidad de imagen de control- TC, de rayos X, mamografíaPH-9 Fantoma de TAC multicortePH-45 Fantoma de imagen digitalPH-7 Fantomas “CT-SEC”

    para control de exposición automática en TCPH-13 Fantoma en mamografía degitalPH-12 Paso fantoma de mamográficaPH-22 Fantoma para control de calidad en TCPH-21 Fantoma para control de calidad en TC

    Fantoma de pulmón de TCPH-9-2 Fantoma el escalónPH-10 Fantoma para tabla de la densidad mineral óseaPH-16 Fantoma el contraste detallePH-17 Fantoma de cuerpo de aguaPH-15 Fantoma substitudo de tejidosPH-14 Fantoma el acrílico

    Bildqualitätskontrolle- CT, Röntgen, MammographiePH-9 Mehrschicht-CT-PhantomPH-45 Digitale Bild PhantomPH-7 Automatic Exposure Control für CT

    "CT-AEC Phantom"PH-13 Digitale Mammographie Phantom NCCEPH-12 Mammographie Stufen Phantom AGH-D210FPH-22 CT QA Phantom CT-200BPH-21 CT QA Phantom JCT

    CT - LungenphantomPH-9-2 CT-Angio "Ladder" - PhantomPH-10 BMD Diagramm Phantom UHAPH-16 Kontrast-Detail PhantomPH-17 Gewässer PhantomWACPH-15 Gewebeersatz Phantoms XURPH-14 Acryl Phantom XAC

    Medicina Nuclear / MRI

    PH-33 Fantoma de MRI de cabezaPH-34 Fantoma de RM de cráneo

    PH-24 Fantoma de miocardioPH-25 Fantoma de miocardioPH-29 Fantoma caliente frío en ECTPH-28 Fantoma para control de calidad en SPECTPH-30 Fantoma para control de calidad en SPECT

    PH-32 Fantoma para control de calidad en MRIPH-31 Fantoma de control de calidad de RM

    Dosimetría y terapiaPH-40

    Series de fantomas robustosPH-41PH-42PH-37 Fantoma de cuerpo (entero) para tratamiento

    PortuguêsNovos produtosPH-50 Phantom de recém-nascido para Raio-X PH-1C Phantom de tórax pediátrico

    GGO tumores phantomPH-49 Phantom de colonografiaPH-51 Phantom de treinamento para fluoroscopia da coluna lombar M43E Simulador de ultrassom de punção compatível de lombar/epidural US-10 Phantom de ultrassom pélvico feminoUS-11 Phantom de ultrassom escrotalUS-13 Phantom de treinamento para ultrassonografia de quadril infantil

    RadiodiagnósticoPH-2 Phantom de corpo inteiroPH-2B Phantom de corpo inteiro41350 -000-11 Phantom de antebraço/Mão fraturada

    PH-2/2B com lesões e patologias adicionaisPH-2C Phantom pediátrico de corpo inteiro

    Phantom pediátrico de fratura de osso

    Peças para PH-2/2B

    EspañolNuevos ProductosPH-50 Fantoma de radiografía simple de neonatoPH-1C Fantoma de tórax pediátrico

    Fantoma de GGO TumeursPH-49 Fantoma de colonoscopia virtual/ TC colonoscopiaPH-51 Fantoma de entrenamiento en fluoroscopia de columna lumbarM43E Simulador de punción lumbar/epidural compatible con ecografíaUS-10 Fantoma de ecografía pélvica femeninaUS-11 Fantoma de ecografía escrotalUS-13 Fantoma de entrenamiento en ecografía de cadera pediátrica

    RadiodiagnósticoPH-2 Fantoma de cuerpo entero PH-2B Fantoma de TC de cuerpo entero41350 -000-11 Fantoma de fractura de mano/antebrazo

    PH-2/2B: Con lesiones y patologías adicionalesPH-2C Fantoma pediátrico de cuerpo entero

    Fantoma de fractura pediátricaPH-1 Fantoma multiproposito de tórax “LUNGMAN”

    PH-8 Fantoma para screening de cáncer de pulmón por TCPH-4 Fantoma de torso de TC/ TC de tóraxPH-3 Fantoma de angiografía cerebral por TCPH-47 Fantoma de ortopantomografíaPH-5 Fantoma de TC de abdomenPH-19 Fantoma de estómago rotaciónPH-46 Fantoma de TC de próstata PH-18 Fantoma de estómago

    Lista de componentes/partes de PH-1-Láminas de tórax-Tumores simulados-Simulation de Tumeurs-Orden de encargo simulation de tumeus-Componentes para radioisótopos

    Fantomas dinámicosPH-48 Fantoma dinámico de corazón y pulmón.PH-39 Fantoma dinámico de tóraxPH-6B Fantoma dinámico de cardioTC

    EcografíaUS-5 Fantoma de ecografía FAST/Abdomen agudoUS-8 Fantoma de ecografía FAST/Abdomen agudo pediátricoUS-7α Fantoma para la realización de ecografía fetal "SPACEFAN-ST"US-6 Fantoma de ecografía de mamaUS-3 Fantoma de ecografía abdominal intraoperatoria y

    Laparoscópica "IOUSFAN"US-1B Fantoma para entrenamiento en ecografía “ABDFAN” US-1 Fantoma para entrenamiento en ecografía “ECHOZY”US-9 Fantoma de Biopsia de Mama Guiada por ecografíaUS-2 Fantoma multipropósito para control de calidad en ecografía11347 -210 Bloque para entrenamiento de canalización vascular ecoguiada “REAL VESSEL”US-4 Fantoma para Control de Calidad en Ecografía de Mama

    Índice multilingüeReferencias publicación

    UltraschallUS-5 FAST / Akut Abdomen PhantomUS-8 US-8 Pädiatrisches FAST/Akut Abdomen PhantomUS-7α Fötus Ultraschall PhantomUS-6 Brust Ultraschall PhantomUS-3 Abdomen Intraoperativ & Laparoskopie

    Ultraschall Phantom "IOUSFAN"US-1B Ultraschall Training Phantom "ABDFAN" US-1 Ultraschall Training Phantom "ECHOZY"US-9 Ultraschall geführte Brust Biopsie PhantomUS-2 Ultraschall QA Phantom, Multi-purpose Phantom11347 -210 Ultraschall Einführung Training Block "REAL VESSEL"US-4 Brust Ultraschall QA Phantom

    Mehrsprachige IndexFundstelle

    232323

    2424242424242525252525

    2727272728

    282829292929

    30-3435

    040506070808091011

    121213

    13141415

    1617171718181818

    16

    13

    26262727

    28

    282829292929

    30-3435

    040506070808091011

    121213

    131414

    13191919

    20

    20

    2121

    2222222222

    21

    2121

    232323

    2424242424242525252525

  • Phantom de cabeça para MRIPhantom avançado de cérebro IB-20

    Multilingual index 32

    Imagem de controle de qualidade- CT, Raio X, mamografiaPH-9 Phantom de multi fatia CTPH-45 Phantom de imagem digital PH-7 Controle automático de exposição para CT

    "Espectro CT-AEC"PH-13 Phantom de digital mammographicPH-12 Phantom de passo mamográficoPH-22 Phantom de CT com garantia de qualidadePH-21 Phantom de CT com garantia de qualidade

    Phantom de pulmão de CTPH-9-2 Escada phantomPH-10 Phantom de osso gráfico densidade mineralPH-16 Detalhe contraste phantomPH-17 Phantom de corpo águaPH-15 Phantom substituto tecidoPH-14 Acrílico phantom

    Medicina Nuclear/MRI

    PH-33 Phantom de cabeça MRIPH-34

    PH-24 Phantom de miocárdio PH-25 Phantom de miocárdioPH-29 Phantom de ECT Hot FriaPH-28 Phantom de SPECT com garantia de qualidadePH-30 Phantom de SPECT com garantia de qualidade

    PH-32 Phantom de MRI com garantia de qualidadePH-31 Phantom de garantia de qualidade MRI

    PH-1 Phantom universal de tórax "Lungman"

    PH-8 Phantom de diagnóstico de câncer de pulmão CTPH-4 Phantom de torso CTPH-3 Phantom angiográfico de cabeça CTPH-47 Phantom de cabeça para radiografia dentalPH-5 Phantom de abdômen CTPH-19 Phantom de estômago rotaçãoPH-46 Phantom de próstata CT PH-18 Phantom de estômago

    Peças para PH-1-Placas do tórax -Bolsa de Transporte-Tumores simulados-Ordem feita sob encomenda simulados Tumores-Componentes para radioisótopo

    PH-9PH-45PH-7

    PH-13PH-12PH-22PH-21

    PH-9-2PH-10PH-16PH-17PH-15PH-14

    PH-33PH-34

    PH-24PH-25PH-29PH-28PH-30

    PH-32PH-31

    PH-40PH-41PH-42PH-37

    PH-50PH-1C

    PH-49PH-51M43EUS-10US-11US-13

    PH-2PH-2B41350 -000-11

    PH-2C

    PH-1

    PH-8PH-4PH-3PH-47PH-5PH-19PH-46PH-18

    PH-48PH-39PH-6B

    Terapia e dosimetriaPH-40

    Série de Phantoms rígidosPH-41PH-42PH-37 Phantomde corpo para terapia

    Phantoms dinâmicosPH-48 Phantom dinâmico de pulmão e coraçãoPH-39 Phantom de tórax dinâmicoPH-6B Phantom cardíaco dinâmico CT

    Echographique US-5 Phantom de abdômen fast/acuteUS-8 Phantom de abdômen pediátrico fast/acuteUS-7α