![Page 1: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/1.jpg)
R&D Department
Battery Monitoring SystemAlarmBox + Extension Modules
![Page 2: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/2.jpg)
AlarmBox
![Page 3: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/3.jpg)
AlarmBox-version1• ชดปมควบคม
• Light On - เปดไฟสาหรบถายภาพในท�มด
• Light Off - ปดไฟ
• Snapshot - บนทกภาพและสงไปยง server
• Up - ปรบมมกลองข �น
• Down - ปรบมมกลองลง
• Left - ปรบมมกลองไปทางซาย
• Right - ปรบมมกลองไปทางขวา
• Center - ปรบมมกลองกลบมายงจดเร�มตน
• สถานะเซนเซอร
• time - แสดงวน เวลา จากอปกรณ
• vbat - แสดงแรงดนแบตเตอร�ภายในอปกรณ
• temp - แสดงอณภมท�วดไดจากเซนเซอรท�อปกรณ
• ncno1-16 - แสดงคาท�อานไดจากวงจรรบสญญาณ NCNO ซ�งจะรบคาจากเซนเซอรตางๆในสถานฐาน
• currentloop1-2 - แสดงคากระแสท�วดไดจากวงจรรบสญญาณ 4-20 mA
• Powerline - แสดงคาจากการตรวจสอบสถานะไฟฟา
220V
![Page 4: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/4.jpg)
Block Diagram
ARM Cortex-M0
ARM9 LAN/HUB
USB Camera
3G Modem
NCNOInput
4-20 mAReceiver
Fan Driver
Temp Sensor
PIR
![Page 5: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/5.jpg)
Web Server
Live View
ชดป มควบคม
สถานะเซนเซอร
![Page 6: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/6.jpg)
![Page 7: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/7.jpg)
![Page 8: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/8.jpg)
![Page 9: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/9.jpg)
![Page 10: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/10.jpg)
AlarmBox-version2-RTC
-MQTT protocol
-4 Analogue Channels input
-Size smaller
-16 Dry Contacts input/ 4 Digital outputs
-Wifi Camera
-Multi Sim
-IP Camera on Streaming
-Mod Bus over RS485
![Page 11: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/11.jpg)
ท�มา : แผนยทธศาสตร การไฟฟาสวนภมภาค พ.ศ. 2557-2566http://www.oic.go.th/FILEWEB/CABINFOCENTER4/DRAWER001/GENERAL/DATA0000/00000083.PDFรายงานดชนความเช�อถอไดของระบบไฟฟา การไฟฟานครหลวงhttp://www.mea.or.th/profile/index.php?l=th&tid=5&mid=307&pid=122
สถตไฟฟาดบ
การไฟฟาสวนภมภาคป 2555
การไฟฟานครหลวงป 2557
(ความถ�ในการเกดไฟดบเฉล�ยตอ 1 ราย ตอป)7.8 คร �ง 1.6 คร �ง
(ระยะเวลาในการเกดไฟดบรวมตอ ตอป) 281 คร �ง 48 คร �ง
(ระยะเวลาท�ไฟดบตอคร �งเฉล�ย) 36 นาท 29 นาท
![Page 12: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/12.jpg)
ขอเสยของแบตเตอร�
การเร�มเส�อมสภาพของแบตเตอร�แตละกอนเกดข �นในเวลาท�ไมแนนอน
การเส�อมสภาพเม�อเกดข �น 1 กอน จะทาใหกอนอ�นๆในระบบเส�อมสภาพเรวข �นดวย
การเส�อมสภาพเกดข �นไดทกเม�อ อาจจะเร�มต �งแตวนท�ผลตเสรจ
![Page 13: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/13.jpg)
Good Battery
Bad Battery
การเส�อมของแบตเตอร� แบบความตานทานภายในสง
ลกษณะอาการ ขณะ Discharge แรงดนจะตกลงอยางรวดเรว และกระแสไฟฟาท�ง String จะตกลงไปดวย
![Page 14: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/14.jpg)
การเส�อมของแบตเตอร� แบบมกระแสร� วไหล
UPS
ItI1
I2
Normal Charging
LOAD
LN
UPS
ItI1
I2
Normal Discharging
LOAD
LN
UPS
ItI1
I2
Fail Charging
LOAD
LN
UPS
ItI1
I2
Fail Discharging
LOAD
LN
ลกษณะอาการ
unbalance chargingและ unbalance discharging
![Page 15: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/15.jpg)
ความเส�ยง
ถาในระบบ Battery ม 1 กอนใน String เกดเส�อมสภาพ และตรวจสอบไมพบ
เม�อเวลาผานไป Battery กอนท�เสยน �น จะทาใหกอนอ�นคอยๆเส�อมสภาพไปดวย
ทายท�สดทาใหระบบแบตเตอร�ไมสามารถจายไฟฟาไดขณะท�การไฟฟาหยดจายไฟ
ผลท�เกดตามมา
การลงทนในระบบไฟสารองของศนยคอมพวเตอรจะสญเปลา
สญเสยทางธรกจเน�องจากระบบคอมพวเตอรหยดใหบรการ
![Page 16: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/16.jpg)
วธปองกน
1. ทาการตวจสภาพของแบตเตอร�เปนประจา โดย
เจาหนาท�ทาการทดสอบการจายไฟฟาของ แบตเตอร�ทกสปดาห
จางผ เช�ยวชาญจากภายนอกตรวจสภาพ รายเดอน
2. จดซ �อระบบ battery monitoring ท�สามารถตรวจสอบแบบ real time และดวยเทคโนโลยท�เหมาะสม
![Page 17: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/17.jpg)
ความเส�ยง
ถาในระบบ Battery ม 1 กอนใน String เกดเส�อมสภาพ และตรวจสอบไมพบ
เม�อเวลาผานไป Battery กอนท�เสยน �น จะทาใหกอนอ�นคอยๆเส�อมสภาพไปดวย
ทายท�สดทาใหระบบแบตเตอร�ไมสามารถจายไฟฟาไดขณะท�การไฟฟาหยดจายไฟ
ผลท�เกดตามมา
การลงทนในระบบไฟสารองของศนยคอมพวเตอรจะสญเปลา
สญเสยทางธรกจเน�องจากระบบคอมพวเตอรหยดใหบรการ
![Page 18: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/18.jpg)
วธปองกน
1. ทาการตวจสภาพของแบตเตอร�เปนประจา โดย
เจาหนาท�ทาการทดสอบการจายไฟฟาของ แบตเตอร�ทกสปดาห
จางผ เช�ยวชาญจากภายนอกตรวจสภาพ รายเดอน
2. จดซ �อระบบ battery monitoring ท�สามารถตรวจสอบแบบ real time และดวยเทคโนโลยท�เหมาะสม
![Page 19: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/19.jpg)
CAT Intranet
CAT Metronet
Server
Feature ท�แตกตาง
BatMon
3G
![Page 20: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/20.jpg)
CAT Intranet
CAT Metronet
Server
Feature ท�แตกตาง
BatMon
![Page 21: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/21.jpg)
System Capabilities
- +12V
- +12V
- +12V
- +12V
1. String voltage measurement ตรวจสอบวาอปกรณชารจทางานอยางถกตองและไดต �งระดบแรงดนไวเหมาะสมกบแบตเตอร�
![Page 22: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/22.jpg)
System Capabilities
- +12V
- +12V
- +12V
- +12V
2. Cell voltage measurement ตรวจสอบวาแบตเตอร�แตละลกมแรงดนชารจท�เหมาะสมหรอไม และแบตเตอร�เส�อมหรอไม
![Page 23: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/23.jpg)
System Capabilities
- +12V
- +12V
- +12V
- +12V
3. String current measurement ตรวจสอบวาแบตเตอร�กาลงถกอดประจหรอคายประจอย สามารถใชแสดงสถานะของแบตเตอร�ได เชน แบตเตอร�ถก
ประจเตมหรอยง และสามารถทานายวาแบตเตอร� cell ใดกาลงจะเสย
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
LOAD
string
Current sensor
![Page 24: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/24.jpg)
System Capabilities
4. Temperature measurement เพ�อแสดงถงอณหภมหองท�ตดต �งแบตเตอร�วาเหมาะสมหรอไม ทาใหแบตเตอร�มอายยนยาว
![Page 25: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/25.jpg)
Wiring Diagram (4 string, 16 cells)
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
- +12V
LOAD
BATTERY MONITORING SYSTEM
ALARM RUN
ALARM RUN NET
RS485
Ala
rm B
ox
Ba
tte
ry
Mo
nito
rin
g S
yste
m
-48V
220VACTe
mp
Se
nso
r21 wires
![Page 26: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/26.jpg)
Software for battery monitoring
สวนแสดงผล
- Web base application ท�สามารถดขอมล real time, ดขอมลยอนหลงผาน HTTP network
- แสดงผลขอมล real time, ขอมลยอนหลงท�งในรปแบบกราฟเคล�อนไหว หรอเปนตวเลขพรอมรป icon
ท�เขาใจงาย
- รองรบการทางานบน browser บนเคร�อง PC, Tablet, Mobile (สาหรบ Mobile จะสามารถดขอมลสรป status)
- หนาจอสาหรบเจาหนาท�ภมภาค
ดขอมลสรปยอด (Summary Dashboard สาหรบภมภาคน�นๆ)
ดรายละเอยดแตละ Site งาน (in detail transaction data) สาหรบ Site งานในภมภาคน�นๆ
- หนาจอสาหรบเจาหนาท�สานกงานใหญ ท�ดสถานะโดยรวมท�วประเทศ
ดขอมลสรปยอด (Summary Dashboard ท�วประเทศ)
![Page 27: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/27.jpg)
Software for battery monitoring
รายงาน (ในรปแบบไฟล Excel หรอ csv)รายงานอตโนมต (Batch job Report)
- ออกรายงาน battery ท�มความผดปกต เกนเกณฑท�กาหนด- ออกรายงานสรป Alarm หรอการกระทาอ�นๆ- ออกรายงาน ประวตการทา maintenance battery (discharge)- สามารถต�งกาหนดการ maintenance- แจงเตอนลวงหนาทาง email เม�อถงกาหนดการท�ต�งไว- ออกรายงานสรป site ท�ไมไดทาการ maintenance เม�อเลยเวลาท�ต�งไว - ออกรายงานสรปขอมล รายวน, รายเดอน ของแตละ site - ออกรายงานสรปขอมล รายวน, รายเดอน ของภมภาค- สามารถต�งใหสงรายงานไปยง e-mail ท�กาหนด
รายงานท�ผใชเลอกสรางเอง (Manual Report)- ออกรายงานขอมล real time จากหนาจอท�กาลงเรยกด - ออกรายงานขอมล ยอนหลง- เลอก วนท�, ชวงวนท� หรอ ชวงเวลา - เลอกรายงานท�วไป หรอ เลอกเหตการณท�สนใจ เชน Alarm, Discharge...
![Page 28: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/28.jpg)
Extension Modules
![Page 29: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/29.jpg)
BATTERY MONITORING UNITDCU + Sensor Node
![Page 30: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/30.jpg)
DCU
• วดแรงดน DC จาก Battery ได 4 ชอง รองรบแรงดน Battery สงสด 48V
• วดกระแส DC ได 4 ชองแบบ Clamp on
• ตอกบ Sensor Node เพ�อวดคาตางๆของ Battery แตละลก
• ใชไฟเล�ยง 48 VDC
![Page 31: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/31.jpg)
DCU
48V 48V 48V
Load / Charge
Batt (1
) +
Batt (4
) +
Batt (2
) +
Batt (3
) +
DC Current Sensor
+4
8 V
DC
GN
D
Sensor Node
12V
12V 12V
12V
![Page 32: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/32.jpg)
Sensor Node
• วดแรงดน DC จาก Battery ได 1 ชอง รองรบแรงดน Battery สงสด 12V
• วดความตานทานภายใน Battery
• วดอณหภมท�ข �ว Battery
• ตอพวงกนได 256 ตว
• ใชไฟเล�ยง 48 VDC
![Page 33: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/33.jpg)
Sensor Node
Sensor Node
Copper Bar Copper Bar
Batt +
48VDC
Data
48 VDC
Data
Batt -
![Page 34: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/34.jpg)
DCU + Sensor Node
12V 12V 12V 12V
12V 12V 12V 12V
12V 12V 12V 12V
12V 12V 12V 12V
Lo
ad
/ C
ha
rge
![Page 35: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/35.jpg)
ACU
• วดแรงดน AC แบบ 3 Phase ได 1 ชอง และวดกระแสแตละPhase แบบ Clamp on
• วดแรงดน AC แบบ 1 Phase ได 3 ชอง และวดกระแสแตละชองแบบ Clamp on
![Page 36: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/36.jpg)
ACU
N L1 L2 L3
N L
N L
N L
![Page 37: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/37.jpg)
DIO
Digital I/O Control
Switch panel
Relay
• Digital output 8 ชอง
• Digital input 8 ชอง
![Page 38: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/38.jpg)
![Page 39: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/39.jpg)
![Page 40: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/40.jpg)
![Page 41: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/41.jpg)
![Page 42: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/42.jpg)
![Page 43: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/43.jpg)
![Page 44: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/44.jpg)
![Page 45: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/45.jpg)
![Page 46: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/46.jpg)
![Page 47: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/47.jpg)
![Page 48: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/48.jpg)
![Page 49: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/49.jpg)
![Page 50: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/50.jpg)
![Page 51: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/51.jpg)
![Page 52: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/52.jpg)
![Page 53: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/53.jpg)
![Page 54: R&D Department Battery Monitoring System AlarmBox+ ...brownien_lab.cattelecom.com/CAT-Batt-Mon-AlarmBox-Extension.pdfUPS It I1 I2 Normal Discharging LOAD N L UPS It I1 I2 Fail Charging](https://reader033.vdocuments.pub/reader033/viewer/2022041616/5e3befcd44658450c445d505/html5/thumbnails/54.jpg)