gaumard - accuratesolutions.it€™s “physiologic” model and software control is powerful, yet...

6
• Easy to use • Fully responsive in transit • Wireless streaming audio • Automatic or Instructor control ® 3101... a proven tetherless simulator HAL ® Gaumard Simulators for Health Care Education

Upload: doantram

Post on 01-May-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

HAL® ... a part of Gaumard’s growing family of tetherless™ simulators

HAL S3101 includes • Tetherless HAL simulator• Heart, lung and bowel sounds • Bilateral IV, BP and oxygen saturation• Instructor’s 12 inch tablet PC with stylus control,”bump” case, docking station and scenarios

• Roller case• Rechargeable battery with 100-240 VAC charger• Blood pressure cuff• Six (6) neck collars• Six (6) replaceable pneumothorax decompression sites• Instructions• DVD tutorial• 1 year warranty

HAL S3101 $32995HAL® is a registered trademark of Gaumard® Scientific Patented; other patents pending

Tetherless technology allows the communications, compressor, and power supply tobe inside HAL, eliminating external tubes, wires, and compressors

HAL operates continuously during transport and training can occur in the working environment

Rush HAL from the accident scene to the ER, to the ICU, while care providers diagnose and treat his condition using real monitoring and resuscitation equipment.Control HAL at distances up to 300 meters and between rooms and floors of conventional buildings. HAL smoothly transitions between physiologic states inresponse to commands from a wireless PC

HAL has conductive skin regions so you can• Apply real electrodes and AED pads• Use real EMS equipment• See HAL’s ECG on your AED

HAL is perfect for competency based programs• Sensors track student actions• Changes to HAL’s condition and care provided are timestamped and logged for evaluation and debriefing

• Instructors evaluate caregiver interventions with a single click and insert notes on a real time performance log

• Save caregiver performance, forward to any standard printer, or link with camera systems

• Easy to use

• Fully responsive in transit

• Wireless streaming audio

• Automatic or Instructor control

Two sites each for needle decompression andchest drainage. I/O site in the lower right leg.Programmable seizures

HAL’s software is powerful, yet intuitive, andcustomers find it easy to use

Fixed and mobile monitors are available. Eachfeatures dynamic waveforms and wireless control

Options• Configurable 17 inch touch screen monitor with AC power cable

• Configurable 12 inch touch screen monitor with stylus control,”bump” case and docking station for tetherless operation

• Tetherless AV system with three cameras, integrated software and rugged carrying case

• Arm/leg stumps bleed in accordance with heart rate and blood pressure

• Trauma packages• Wound modules• Tutorial workshops• Extended warranty• Installation and training at your facility• Training at our simulation centers

®

Gaumard® ScientificToll Free USA 800.882.6655Worldwide 305.971.3790Fax 305.667.6085Website www.gaumard.comEmail [email protected]

©Gaumard Scientific Company, 2009Made in U.S.A. All rights reserved

3101... a proven tetherless simulatorHAL®

Tetherless™ technology was pioneered by Gaumard in 2004

HAL is rushed from the helicopter to the OR where care providers treat him. Activities are monitored and recorded for debriefing

HAL links with many camera systems. This AV recording system is tetherless and fully functional while HAL is in transit

GaumardSimulators for Health Care Education

127257_Hal_3101:124558_Gaumard.4 6/26/09 12:32 PM Page 1

Configure HAL’s simulated vital signs monitor to suit your training needsHAL’s “physiologic” model and software control is powerful, yet intuitive, and easy to use

Airway• Oral or nasal intubation• Programmable airway • Sensors detect depth of intubation • Perform tracheostomy or needle cricothyrotomy• Unilateral chest rise with right mainstemintubation

• Multiple upper airway sounds synchronized with breathing

Breathing• Control rate and depth of respirationand observe chest rise

• Ventilation is measured and logged• Gastric distension with excess BVM ventilation

• Select independent left, right, upper, andlower lung sounds

• Chest rise and lung sounds are synchronized with selectable breathing patterns

• Accommodates assisted ventilation including BVM and mechanical support

• Unilateral chest rise simulates pneumothoraces and multiple breath sounds

Circulation and color change• Multiple heart sounds, rates, and intensities• Chest compressions are measured and logged• Blood pressure can be taken bilaterally using a cuff, palpation, or auscultation

• Korotkoff sounds audible between systolic and diastolic pressures• Cyanosis and vital signs respond to physiologic condition and interventions

• Bilateral carotid, radial, brachial, femoral, and pedal pulses operate continuously. Pulse strengths vary with HAL’s blood pressure and pulsesare synchronized with the ECG

Venous access• Bilateral IV training arms• IM sites on shoulders and thighs• Intraosseous access at tibia

HAL® ...tetherless and fully responsive even while being transported

Easy to Use• Automatic or Instructor control• Use our preprogrammed scenarios, modify them, or create your ownquickly and easily

• Access the “Details” page and jump between physiologic states inresponse to the interventions of caregivers

• Change conditions such as heart rate and blood pressure directly sincethe cardiovascular details are automatically adjusted by the software

• Link “Palette” items to build a linear or branching scenario• Pause the scenario or jump to the next critical decision point

Automatic Control• Responds automatically to caregiver or Instructor intervention• Responses such as cyanosis and vital signs change automatically in accordance with weight

• Responds to pharmacologic interventions; administer medications fromour list or even add medications using our drug template

Active Eyes• Automatic or Instructor control• Open and close • Select blink rate• Select pupillary response to light

Voice Responses• Wireless streaming audio . Be the voice of HALand hear responses at distances up to 150 feet

• Create and store vocal responses in any language• Select from a pre-recorded vocal menu

Log• Track the actions of up to six care providers using our response menu or write a narrative

• Links with audio-visual systems that integrate the event log with feedsfrom cameras and the simulated patient monitor for comprehensivedebriefing

Configure monitor to suit your needs• HAL’s monitor can be configured to suit the scenario Here we chose four dynamic waveforms, a number of scalars, and selected appropriate colors

• Display up to 12 numeric values including HR, ABP, CVP, PAWP, NIRP, CCO, SpO2, SvO2, RR, EtCO2, temperature, time

• Select up to 12 dynamic waveforms includingECG Lead I, II, III, aVR, aVL, aVF, V1, V2, V3, V4,V5, V6,AVP, CVP, PAWP, pulse, CCO, SvO2, respiration,capnography

• Set alarms for HR, SpO2, NIBP, ABP, RR, EtCO2, CCO, CVP, PAWP and SvO2

Advanced 12 lead ECG• Since HAL’s model operates automatically, you may display up to 12 dynamic waveforms and 12 scalars, locate them where you wish and choose appropriate colors

• HAL also features a dynamic 12 lead ECG and you may even select a 12 lead strip recording during the scenario

Choose your monitor• Select a 17 inch touchscreen monitor with AC power or a 12 inch tablet PC monitor with DC power

• Use our simulated vital signs monitor or design one that meets your needs

• Share images such as x-rays, CT scans, lab results, or even multimedia presentations as the scenario progresses

127257_Hal_3101:124558_Gaumard.4 6/22/09 9:04 AM Page 2

creo

Configure HAL’s simulated vital signs monitor to suit your training needsHAL’s “physiologic” model and software control is powerful, yet intuitive, and easy to use

Airway• Oral or nasal intubation• Programmable airway • Sensors detect depth of intubation • Perform tracheostomy or needle cricothyrotomy• Unilateral chest rise with right mainstemintubation

• Multiple upper airway sounds synchronized with breathing

Breathing• Control rate and depth of respirationand observe chest rise

• Ventilation is measured and logged• Gastric distension with excess BVM ventilation

• Select independent left, right, upper, andlower lung sounds

• Chest rise and lung sounds are synchronized with selectable breathing patterns

• Accommodates assisted ventilation including BVM and mechanical support

• Unilateral chest rise simulates pneumothoraces and multiple breath sounds

Circulation and color change• Multiple heart sounds, rates, and intensities• Chest compressions are measured and logged• Blood pressure can be taken bilaterally using a cuff, palpation, or auscultation

• Korotkoff sounds audible between systolic and diastolic pressures• Cyanosis and vital signs respond to physiologic condition and interventions

• Bilateral carotid, radial, brachial, femoral, and pedal pulses operate continuously. Pulse strengths vary with HAL’s blood pressure and pulsesare synchronized with the ECG

Venous access• Bilateral IV training arms• IM sites on shoulders and thighs• Intraosseous access at tibia

HAL® ...tetherless and fully responsive even while being transported

Easy to Use• Automatic or Instructor control• Use our preprogrammed scenarios, modify them, or create your ownquickly and easily

• Access the “Details” page and jump between physiologic states inresponse to the interventions of caregivers

• Change conditions such as heart rate and blood pressure directly sincethe cardiovascular details are automatically adjusted by the software

• Link “Palette” items to build a linear or branching scenario• Pause the scenario or jump to the next critical decision point

Automatic Control• Responds automatically to caregiver or Instructor intervention• Responses such as cyanosis and vital signs change automatically in accordance with weight

• Responds to pharmacologic interventions; administer medications fromour list or even add medications using our drug template

Active Eyes• Automatic or Instructor control• Open and close • Select blink rate• Select pupillary response to light

Voice Responses• Wireless streaming audio . Be the voice of HALand hear responses at distances up to 150 feet

• Create and store vocal responses in any language• Select from a pre-recorded vocal menu

Log• Track the actions of up to six care providers using our response menu or write a narrative

• Links with audio-visual systems that integrate the event log with feedsfrom cameras and the simulated patient monitor for comprehensivedebriefing

Configure monitor to suit your needs• HAL’s monitor can be configured to suit the scenario Here we chose four dynamic waveforms, a number of scalars, and selected appropriate colors

• Display up to 12 numeric values including HR, ABP, CVP, PAWP, NIRP, CCO, SpO2, SvO2, RR, EtCO2, temperature, time

• Select up to 12 dynamic waveforms includingECG Lead I, II, III, aVR, aVL, aVF, V1, V2, V3, V4,V5, V6,AVP, CVP, PAWP, pulse, CCO, SvO2, respiration,capnography

• Set alarms for HR, SpO2, NIBP, ABP, RR, EtCO2, CCO, CVP, PAWP and SvO2

Advanced 12 lead ECG• Since HAL’s model operates automatically, you may display up to 12 dynamic waveforms and 12 scalars, locate them where you wish and choose appropriate colors

• HAL also features a dynamic 12 lead ECG and you may even select a 12 lead strip recording during the scenario

Choose your monitor• Select a 17 inch touchscreen monitor with AC power or a 12 inch tablet PC monitor with DC power

• Use our simulated vital signs monitor or design one that meets your needs

• Share images such as x-rays, CT scans, lab results, or even multimedia presentations as the scenario progresses

127257_Hal_3101:124558_Gaumard.4 6/22/09 9:04 AM Page 2

creo

Configure HAL’s simulated vital signs monitor to suit your training needsHAL’s “physiologic” model and software control is powerful, yet intuitive, and easy to use

Airway• Oral or nasal intubation• Programmable airway • Sensors detect depth of intubation • Perform tracheostomy or needle cricothyrotomy• Unilateral chest rise with right mainstemintubation

• Multiple upper airway sounds synchronized with breathing

Breathing• Control rate and depth of respirationand observe chest rise

• Ventilation is measured and logged• Gastric distension with excess BVM ventilation

• Select independent left, right, upper, andlower lung sounds

• Chest rise and lung sounds are synchronized with selectable breathing patterns

• Accommodates assisted ventilation including BVM and mechanical support

• Unilateral chest rise simulates pneumothoraces and multiple breath sounds

Circulation and color change• Multiple heart sounds, rates, and intensities• Chest compressions are measured and logged• Blood pressure can be taken bilaterally using a cuff, palpation, or auscultation

• Korotkoff sounds audible between systolic and diastolic pressures• Cyanosis and vital signs respond to physiologic condition and interventions

• Bilateral carotid, radial, brachial, femoral, and pedal pulses operate continuously. Pulse strengths vary with HAL’s blood pressure and pulsesare synchronized with the ECG

Venous access• Bilateral IV training arms• IM sites on shoulders and thighs• Intraosseous access at tibia

HAL® ...tetherless and fully responsive even while being transported

Easy to Use• Automatic or Instructor control• Use our preprogrammed scenarios, modify them, or create your ownquickly and easily

• Access the “Details” page and jump between physiologic states inresponse to the interventions of caregivers

• Change conditions such as heart rate and blood pressure directly sincethe cardiovascular details are automatically adjusted by the software

• Link “Palette” items to build a linear or branching scenario• Pause the scenario or jump to the next critical decision point

Automatic Control• Responds automatically to caregiver or Instructor intervention• Responses such as cyanosis and vital signs change automatically in accordance with weight

• Responds to pharmacologic interventions; administer medications fromour list or even add medications using our drug template

Active Eyes• Automatic or Instructor control• Open and close • Select blink rate• Select pupillary response to light

Voice Responses• Wireless streaming audio . Be the voice of HALand hear responses at distances up to 150 feet

• Create and store vocal responses in any language• Select from a pre-recorded vocal menu

Log• Track the actions of up to six care providers using our response menu or write a narrative

• Links with audio-visual systems that integrate the event log with feedsfrom cameras and the simulated patient monitor for comprehensivedebriefing

Configure monitor to suit your needs• HAL’s monitor can be configured to suit the scenario Here we chose four dynamic waveforms, a number of scalars, and selected appropriate colors

• Display up to 12 numeric values including HR, ABP, CVP, PAWP, NIRP, CCO, SpO2, SvO2, RR, EtCO2, temperature, time

• Select up to 12 dynamic waveforms includingECG Lead I, II, III, aVR, aVL, aVF, V1, V2, V3, V4,V5, V6,AVP, CVP, PAWP, pulse, CCO, SvO2, respiration,capnography

• Set alarms for HR, SpO2, NIBP, ABP, RR, EtCO2, CCO, CVP, PAWP and SvO2

Advanced 12 lead ECG• Since HAL’s model operates automatically, you may display up to 12 dynamic waveforms and 12 scalars, locate them where you wish and choose appropriate colors

• HAL also features a dynamic 12 lead ECG and you may even select a 12 lead strip recording during the scenario

Choose your monitor• Select a 17 inch touchscreen monitor with AC power or a 12 inch tablet PC monitor with DC power

• Use our simulated vital signs monitor or design one that meets your needs

• Share images such as x-rays, CT scans, lab results, or even multimedia presentations as the scenario progresses

127257_Hal_3101:124558_Gaumard.4 6/22/09 9:04 AM Page 2

creo

HAL® ... a part of Gaumard’s growing family of tetherless™ simulators

HAL S3101 includes • Tetherless HAL simulator• Heart, lung and bowel sounds • Bilateral IV, BP and oxygen saturation• Instructor’s 12 inch tablet PC with stylus control,”bump” case, docking station and scenarios

• Roller case• Rechargeable battery with 100-240 VAC charger• Blood pressure cuff• Six (6) neck collars• Six (6) replaceable pneumothorax decompression sites• Instructions• DVD tutorial• 1 year warranty

HAL S3101 $32995HAL® is a registered trademark of Gaumard® Scientific Patented; other patents pending

Tetherless technology allows the communications, compressor, and power supply tobe inside HAL, eliminating external tubes, wires, and compressors

HAL operates continuously during transport and training can occur in the working environment

Rush HAL from the accident scene to the ER, to the ICU, while care providers diagnose and treat his condition using real monitoring and resuscitation equipment.Control HAL at distances up to 300 meters and between rooms and floors of conventional buildings. HAL smoothly transitions between physiologic states inresponse to commands from a wireless PC

HAL has conductive skin regions so you can• Apply real electrodes and AED pads• Use real EMS equipment• See HAL’s ECG on your AED

HAL is perfect for competency based programs• Sensors track student actions• Changes to HAL’s condition and care provided are timestamped and logged for evaluation and debriefing

• Instructors evaluate caregiver interventions with a single click and insert notes on a real time performance log

• Save caregiver performance, forward to any standard printer, or link with camera systems

• Easy to use

• Fully responsive in transit

• Wireless streaming audio

• Automatic or Instructor control

Two sites each for needle decompression andchest drainage. I/O site in the lower right leg.Programmable seizures

HAL’s software is powerful, yet intuitive, andcustomers find it easy to use

Fixed and mobile monitors are available. Eachfeatures dynamic waveforms and wireless control

Options• Configurable 17 inch touch screen monitor with AC power cable

• Configurable 12 inch touch screen monitor with stylus control,”bump” case and docking station for tetherless operation

• Tetherless AV system with three cameras, integrated software and rugged carrying case

• Arm/leg stumps bleed in accordance with heart rate and blood pressure

• Trauma packages• Wound modules• Tutorial workshops• Extended warranty• Installation and training at your facility• Training at our simulation centers

®

Gaumard® ScientificToll Free USA 800.882.6655Worldwide 305.971.3790Fax 305.667.6085Website www.gaumard.comEmail [email protected]

©Gaumard Scientific Company, 2009Made in U.S.A. All rights reserved

3101... a proven tetherless simulatorHAL®

Tetherless™ technology was pioneered by Gaumard in 2004

HAL is rushed from the helicopter to the OR where care providers treat him. Activities are monitored and recorded for debriefing

HAL links with many camera systems. This AV recording system is tetherless and fully functional while HAL is in transit

GaumardSimulators for Health Care Education

127257_Hal_3101:124558_Gaumard.4 6/26/09 12:32 PM Page 1