relé 24vcd rumc2ab1bd

5
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 7/9/2011 1 Product data sheet Characteristics RUMC2AB1BD universal plug-in relay - Zelio RUM - 2 C/O - 24 V DC - 10 A Main Range of product Zelio Relay Series name Universal Product or component type Plug-in relay Device short name RUM Contacts type and composition 2 C/O Contacts operation Standard Control circuit voltage 24 V DC [Ithe] conventional enclosed thermal current 10 A at <= 55 °C Status LED Without Control type Pushbutton Coil interference suppression Without Utilisation coefficient 20 % Sale per indivisible quantity 10 Complementary Shape of pin Cylindrical [Ui] rated insulation voltage 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL [Uimp] rated impulse withstand voltage 4 kV conforming to IEC 61000-4-5 Contacts material Silver alloy (Ag/Ni) [Ie] rated operational current 10 A (AC-1/DC-1) NO conforming to IEC 12 A at 28 V (DC-1) conforming to UL 16 A at 277 V (AC-1) conforming to UL 5 A (AC-1/DC-1) NC conforming to IEC Minimum switching current 10 mA Maximum switching voltage 250 V AC conforming to IEC 250 V DC conforming to IEC Minimum switching voltage 17 V Resistive rated load 10 A at 250 V AC 10 A at 28 V DC Maximum switching capacity 2500 VA, AC circuit 280 W, DC circuit Minimum switching capacity 170 mW Operating rate <= 200 cyc/mn (no-load) <= 30 cyc/mn (under load) Mechanical durability 5000000 cycles Electrical durability 100000 cycles for resistive load Average consumption in W 1.4 W, DC circuit Average consumption in VA 2...3, AC circuit Drop-out voltage threshold >= 0.1 Uc (DC >= 0.15 Uc (AC Operating time 20 ms between coil de-energisation and making of the Off-delay contact (AC/DC) 20 ms between coil energisation and making of the On-delay contact (AC/DC) Average resistance 470 Ohm, DC circuit at 20 °C +/- 10 % Rated operational voltage limits 19.2...26.4 V DC

Upload: electroz3l6

Post on 19-Jul-2016

218 views

Category:

Documents


3 download

DESCRIPTION

relé schneider

TRANSCRIPT

The

info

rmat

ion

prov

ided

in th

is d

ocum

enta

tion

cont

ains

gen

eral

des

crip

tions

and

/or t

echn

ical

cha

ract

eris

tics

of th

e pe

rform

ance

of t

he p

rodu

cts

cont

aine

d he

rein

.Th

is d

ocum

enta

tion

is n

ot in

tend

ed a

s a

subs

titut

e fo

r and

is n

ot to

be

used

for d

eter

min

ing

suita

bilit

y or

relia

bilit

y of

thes

e pr

oduc

ts fo

r spe

cific

use

r app

licat

ions

.It

is th

e du

ty o

f any

suc

h us

er o

r int

egra

tor t

o pe

rform

the

appr

opria

te a

nd c

ompl

ete

risk

anal

ysis

, eva

luat

ion

and

test

ing

of th

e pr

oduc

ts w

ith re

spec

t to

the

rele

vant

spe

cific

app

licat

ion

or u

se th

ereo

f.N

eith

er S

chne

ider

Ele

ctric

Indu

strie

s SA

S no

r any

of i

ts a

ffilia

tes

or s

ubsi

diar

ies

shal

l be

resp

onsi

ble

or li

able

for m

isus

e of

the

info

rmat

ion

cont

aine

d he

rein

.

7/9/20111

Product data sheetCharacteristics

RUMC2AB1BDuniversal plug-in relay - Zelio RUM - 2 C/O - 24V DC - 10 A

MainRange of product Zelio RelaySeries name UniversalProduct or componenttype

Plug-in relay

Device short name RUMContacts type andcomposition

2 C/O

Contacts operation StandardControl circuit voltage 24 V DC[Ithe] conventionalenclosed thermalcurrent

10 A at <= 55 °C

Status LED WithoutControl type PushbuttonCoil interferencesuppression

Without

Utilisation coefficient 20 %Sale per indivisiblequantity

10

ComplementaryShape of pin Cylindrical[Ui] rated insulation voltage 250 V conforming to IEC

300 V conforming to CSA300 V conforming to UL

[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 61000-4-5Contacts material Silver alloy (Ag/Ni)[Ie] rated operational current 10 A (AC-1/DC-1) NO conforming to IEC

12 A at 28 V (DC-1) conforming to UL16 A at 277 V (AC-1) conforming to UL5 A (AC-1/DC-1) NC conforming to IEC

Minimum switching current 10 mAMaximum switching voltage 250 V AC conforming to IEC

250 V DC conforming to IECMinimum switching voltage 17 VResistive rated load 10 A at 250 V AC

10 A at 28 V DCMaximum switching capacity 2500 VA, AC circuit

280 W, DC circuitMinimum switching capacity 170 mWOperating rate <= 200 cyc/mn (no-load)

<= 30 cyc/mn (under load)Mechanical durability 5000000 cyclesElectrical durability 100000 cycles for resistive loadAverage consumption in W 1.4 W, DC circuitAverage consumption in VA 2...3, AC circuitDrop-out voltage threshold >= 0.1 Uc (DC

>= 0.15 Uc (ACOperating time 20 ms between coil de-energisation and making of the Off-delay contact (AC/DC)

20 ms between coil energisation and making of the On-delay contact (AC/DC)Average resistance 470 Ohm, DC circuit at 20 °C +/- 10 %Rated operational voltage limits 19.2...26.4 V DC

2

Protection category RT IOperating position Any positionProduct weight 0.085 kg

EnvironmentDielectric strength 1500 V AC (between contacts)

1550 V AC (between coil and contact)1550 V AC (between poles)

Product certifications CSAUL

Standards CSA C22-2 No 14EN/IEC 61810-1 (iss. 2)UL 508

Ambient air temperature for storage -40...85 °CAmbient air temperature for operation -40...55 °CVibration resistance 3 gn (f = 10...150 Hz), amplitude +/- 1 mm (on opening) conforming to EN/IEC

60068-2-274 gn (f = 10...150 Hz), amplitude +/- 1 mm (on closing) conforming to EN/IEC60068-2-27

IP degree of protection IP40 conforming to EN/IEC 60529Shock resistance 10 gn on closing conforming to EN/IEC 60068-2-27

10 gn on opening conforming to EN/IEC 60068-2-27RoHS EUR status CompliantRoHS EUR conformity date 0801

3

Product data sheetDimensions Drawings

RUMC2AB1BD

Universal Relay

Dimensions

4

Product data sheetConnections and Schema

RUMC2AB1BD

Universal Relay

Wiring Diagram

Universal Relay

Wiring Diagram

Symbols shown in blue correspond to Nema marking.

5

Product data sheetPerformance Curves

RUMC2AB1BD

RUM Universal Relays

Electrical Durability of ContactsDurability (inductive load) = durability (resistive load) x reduction coefficient.Resistive AC load

X Switching capacity (kVA)Y Durability (Number of operating cycles)A RUMF•••••, RUMC2•••, RUMC3A•••B RUMC3G•••

Reduction coefficient for inductive AC load (depending on power factor cos ϕ)

Y Reduction coefficient (A)

Maximum switching capacity on resistive DC load

X Voltage DCY Current DCA RUMF•••••, RUMC2•••, RUMC3A•••B RUMC3G•••