Product Catalog Research facilities and research institutions Stepping Motor Driver Research facilities and research institutions Motion Control SACLA/SPring-8(OfferNational Research and Development Agency RIKEN) Vol. 5.2 SPring-8 SACLA 19-inch Rack Cabinet Information about the Other product and service Motion control for research facilities and research institutions 19-inch rack cabinet for Research facilities and measurement system Motion control by a Personal computer. Other. Development of core devices 2016.05

Upload: others

Post on 17-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

・ 研究施設、計測システム向け

19インチラックキャビネット

・ パソコンによるモーション

コントロール、他

・ コアデバイスの開発

Product CatalogResearch facilities and research institutions

Stepping Motor DriverResearch facilities and research institutions

Motion Control

SACLA/SPring-8(Offer:National Research and Development Agency RIKEN)

Vol.5.2

SPring-8

SACLA

19-inch Rack Cabinet

Information about theOther product and service

Motion control for researchfacilities and research institutions

19-inch rack cabinet for Research facilities and measurement system

Motion control by a Personalcomputer. Other.

Development of core devices

2016.05

Page 2: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Motion control for research facility and research institutions

●It can be detected Easy assembly and Installation by the

set providing of Driver, cable, 3U shelf board and Rack

●Lineup of stepping motor Driver is DC24V specification

(1-axis, 2-axes) and AC100V specifications (1 axis).

●Dedicated cable also multiple lineup.

●This driver by the original technology is realized

smooth rotation also in the FULL / HALF STEP angle.

132.55m

0.00018 ゚/STEP(1/2,000,000)

5-phase Stepping MotorGDB-5F40

Now, it rises to "one-2,000,000th "

(High resolution, high precision)

・GDB series・GD series

●The GDB-5F series is incorporated in H750v1, H717A.

●The 8-axes driver unit mounted in 3U shelf board drawer type

●A cable and an exclusive rack besides a driver and 3U shelf board drawer type are offered.

●Mounting spaces are sharply reduced by miniaturization of a driver unit.

( Four 2- axes driver + One power supply)

Signal cable

Motor / sensor

H718/GD-5410H-584,AD-5610

Motor/ sensor cable

Controller

J2J1

Single-phase100V(50/60Hz)

 ・ 1800 mm (36 U) rack 3Ux12step is possible to 96 axes setting  (4Ux9 step is 50 axes)

institutions of the National Research and Development Agency.

It is adopted in research institutions of the National Research and Development Agency,SPring-8 and SACLA and gets a high evaluation.

"one-2,000,000th "

●Technology of a "one-400,000th " approved from the research

●19-inch rack(810series)●Shelf board for exclusive use of 3U size (Max8-axes) 1台)●3U size driver H7500v1 x4、 power supply H-539C x1 (A miniaturization, a cost cut)●An exclusive cable (A signal cable, a motor/sensor cable)

<Offer an example of 8-axes>

3U size(max 8-axes)1,800mm (36 U) rack3Ux12step 96 axessetting is possible(4Ux9 step 50axes)

ControllerJ1J2

J2J1

Signal cable

H750V1/GDB-5F40

J1J2

J2J1

Signal cable

H750V1/GDB-5F40

J1J2

J2J1

Signal cable

H750V1/GDB-5F40

J1J2

J2J1

Signal cable

H750V1/GDB-5F40

3U specification

H-539C (power supply)

DC+24V

Motor/ sensor cable

Motor/ sensor cable

Motor/ sensor cable

Motor/ sensor cable

Motor / sensor

Motor / sensor

Motor / sensor

Single-phase100V(50/60Hz)

Motor / sensor

2

Page 3: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Motion control for research facility and research institutions

3U specification

Axes 2-axes 1-axis

Applicable Motors 0.75~1.4(A/phase)

Output Current 0.3~1.35(A/phase)

Resolving Ability 2,000,000P/R

1/Divisions 1/1,1/2,1/4,1/10,1/20,1/40,1/100,1/200,1/400,1/800,1/1000,1/2000,1/4000

500KHz

Dimensions H110 × W73 × D190.5 (mm)/1.5Kg H110 × W45 × D190.5(mm)/1.0Kg

Supply Power DC +24V/4.0A DC +24V/2.0A

Applicable Drivers H750V1/GDB-5F40、H717A/GDB-5F40

Supply Power

output voltage DC +24V /MAX4.8A × 2CH

4 Driver(8-axes)

2 Driver(4-axes)

Conditions: Simultaneous DRIVE 2-axes,HOLD 2-axes per 1CH X2ch(J1,J2)

Current capacity Maximum 4.8A

Dimensions H112×W69×D305 (mm)/2.0Kg

4U specification

Axes 1-axis 1-axis

Applicable Motors 0.75~1.4(A/phase) 1.4~2.8(A/phase) 0.75~1.4(A/phase)

Output Current 0.34~1.35(A/phase) 0.34~2.25(A/phase) 0.34~1.35(A/phase)

Resolving Ability 200,000P/R 80,000P/R 20,000P/R

1/Divisions

500KHz 500KHz 6 Driver×2CH

Dimensions H156.5×W62×D190.5(mm) H150 × W65 × D325 (mm) H117 × W45 × D190.5

/1.6Kg /2.8Kg (mm)/1.2Kg

Supply Power DC +24V/2.0A

SPring-8 Appellation MELEC Model Name Axes Applicable Motor Supply Power Based driver*

Type ⅡSPDC H750v1/GDB-5F40 0.75~1.4(A/相) DC+24V Equivalent to GDB-5F40 H-539C、H-539D

Type ⅡSPC H717A/GDB-5F40 0.75~1.4(A/相) DC+24V Equivalent to GDB-5F40 H-539C、H-539D

Type ⅡSP H717/GDB-5411A-00 0.75~1.4(A/相) DC+24V Equivalent to GDB-5411A-00 H-539A

Type ⅠSP H718/GD-5410 0.75~1.4(A/相) AC100V / AC115V Equivalent to GD-5410 -

Type ⅢS H-584,AD-5610 1.4~2.8(A/相) AC100V / AC115V Equivalent to AD-5610 -

*::Torque Characteristics of installed drive are described in the Instructions Manual.

The Instructions Manual can be download from the MELEC-INC. website.

2

1

1

1

1

Maximum responsefrequency

1,2,4,8,10,16,20,40,80,160

Single-phase 100-115V(50/60Hz)/700VA (Exclusive power

supply・・・H-539A)

1/1,1/2,1/4,1/10,1/20,1/40,1/100,1/200,1/400

Single-phase 100V(50/60Hz)/4.1A

Single-phase 100V(50/60Hz)/2.0~2.5A

Single-phase 100-115V(50/60Hz)/220VA

1/1,1/2,1/4,1/10,1/20,1/40,1/100,1/200,1/400

outputvoltage

DC +24V/MAX5.5A × 2CH

Exclusivepowersupply forDrivers

Number that can beinstalled

ApplicableDrivers H717/GDB-5411A-00

SupplyPower

Single-phase 100V(50/60Hz)/4.1A

Maximum responsefrequency

(Exclusive power supply・・・H-539C or H-539D)

(Exclusive power supply・・・H-539C or H-539D)

Exclusive powersupply for Drivers

Exclusive powersupply

Numberthat canbe installed

SimultaneousDRIVE 2-axes,HOLD 4-axesper 1CH

Dimensions H120×W50×D295(mm)/1.7Kg

<H750V1/GDB-5F40> (Type ⅡSPDC)

<H717A/GDB-5F40>(Type ⅡSPC)

<H-539A>(POWER SUPPLY Ⅱ)

<H718/GD-5410>(Type ⅠSP)

<H-584,AD-5610>(Type ⅢS) <H717/GDB-5411A-00>

(Type ⅡSP)

<Pulse input method Stepping Motor Driver >

new product

2-axes 1-axis

DC INPUT TYPE DC INPUT TYPE

AC INPUT TYPE

1-axis

AC INPUT TYPE(High-speed type motor)

1-axis1-axis

DC INPUT TYPE

<H-539D>

new product

<H-539C>(POWER SUPPLY Ⅱ L Type)

・3U size・Low noisespecification

POWER SUPPLY ⅡAC220V INPUT L Type

・AC220V input specifications of H-539C equivalent

(NEMA L6-15R)

3

Page 4: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Motion control for research facility and research institutions

● Please contact us for details of specifications to our office.

● Motor / sensor cable and signal cables are custom order.

● Signal cable(SPring-8 connection standards:W021、W022)Other specifications

wire rod Connector shield-processing

1 、2 H750v1/GDB-5F40 Twisted pair 5pair DSUB9(Socket)

H717A/GDB-5F40 Shielded cable0.2SQ

H717/GDB-5411A-00 plastic sheath

( m) H718/GD-5410 DSUB9(Pin)

H-584,AD-5610

● Motor / sensor cable(SPring-8 connection standards:W002)

Other specifications

Connection shield-processing Contact

①1axis plastic sheath ①Glass fiber filled 10、15、20 H750v1/GDB-5F40 RM**M*3KJ(SOURIAU)

PBT Resin 25,30、35 H717A/GDB-5F40 (Gold-plated pin)

②2 axes plastic sheath 40 H717/GDB-5411A-00

②Aluminum alloy H718/GD-5410 RC**M*3KJ(SOURIAU)

( m) H-584,AD-5610 (Gold plated socket)

● 1-axis ● 2-axes

● Motor / sensor cable(SPring-8 connection standards:W011)

Other specifications

shield-processing Contact

①1axis plastic sheath ①Glass fiber filled 10、15、20 H750v1/GDB-5F40 RM**M*3KJ(SOURIAU)

PBT Resin 25,30、35 H717A/GDB-5F40 (Gold-plated pin)

②2 axes plastic sheath 40 H717/GDB-5411A-00

②Aluminum alloy H718/GD-5410 RC**M*3KJ(SOURIAU)

( m) H-584,AD-5610 (Gold plated socket)

● 1-axis ● 2-axes

Line 1 shield arecrimp to the crimpterminal in thedriver side

one forone

Line 1 shield arecrimp to the crimpterminal in thedriver side

wire rodConnector Body Materialof the Driver side

Cable length(L)(m)

Application anduse models

Application anduse models

The connection tothe shell on bothsides

:Equivalent to 17JE-13090- 02(D1)A(DDK)

:Equivalent to 17JE-23090- 02(D1)(DDK)

ConnectionCable length(L)(m)

Application anduse models

② Reverse connection

wire rodConnector BodyMaterial

Cable length(L)(m)

① Normal connection

<Connection/other>●The length of the cable can choose the single-axis or two-axes.

●1axis

●2axes *Shield contact with each other

0.3SQ×3

0.75SQ×5

sheat

shield

Approx.φ9.5

*Shield contact with each other

0.3SQ×3

0.75SQ×5

sheat

shield

Approx.φ12.1

<Cable specification>

<Cable specification>

●1axis

●2axes

0.3SQ×5

0.75SQ×5

sheath

shield

Approx.φ11.3 0.3SQ×5

0.75SQ×5

sheathshield

Approx.φ13.2

Motor/Sensor Cable

Signal CableDriver Motor/SensorContorller

(Sensor signal)

<Cable specification>

Signal Cable

Driver Motor/SensorContorller

Motor/Sensor Cable

Motor/Sensor Cable

Signal Cable

Driver Motor/SensorContorller

*Shield contact with each other*Shield contact with each other

H751-23-01/BL-GE-SMTR-W002-350/D

566261EX2023

H751-23-01

EX2023566261

/BL-GE-SMTR-W002-350/D

500

180

500

4

Page 5: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Motion control for research facility and research institutions

● Dedicated shelf board for mounting the Melec Inc. driver and power supply in a 19-inch rack

This has become a safety design to prevent accidents caused by contact failure or dropout of the connector portion.

●This shelf board can be pulled out the rack rear direction in consideration of the wiring efficiency .

●This shelf board can be mounted with four screws on the front on the 19-inch rack .

●This shelf board can be installed in the space of 3U height of the EIA standard.

№ Product name Model name Applicable Remarks

① 3U shelf board drawer type(5unit) OP-08-04 H750v1/GDB-5F40 Dimensions:W482.6×H132.55(3U)×D410(D560 at pull-out))

H717A/GDB-5F40 Weight:6.4kg

H-539C

H-539D

3U shelf board drawer type(5unit)

●This shelf board can be mounted with four screws on the front on the 19-inch rack .

●This shelf board can be installed in the space of 4U height of the EIA standard.

№ Product name Model name Applicable Remarks

① 4U shelf board drawer type(6unit)OP-08-05 H717/GDB-5411A-00 Dimensions:W482.6×H177(4U)×D410

H718/GD-5410 Weight:5.0kg

H-584,AD-5610

H-539A

The BINDING WIRE hole is provided on the shelf board after the surface, you can reduce the cable loadapplied to the connector portion of the driver and the like.

Driver one unit, or designed in consideration of the maintenance that can be extracted to the driver shelfboard each front side

It is possible to pull out 150mm a shelf board in the rack back side. Design this is in consideration of thewiring efficiency .(3U shelf board drawer type)

<Connection/other>

It is possible to pull out 150mm a shelf board in the rack back side.Design This is in consideration of the wiring efficiency .

This is a picture of when it was pulled out of the shelf board in the rack rear direction.

Rack rear sideRack front side

5

Page 6: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Motion control for research facility and research institutions

● This is a motion control system of DeviceNet I / F.

● Equipped with the absolute address position management function

In the case of power ON, returning to the origin will be unnecessary.

● Connection mistake and assembling man-hours are reduced

by the standard cable.

This controller driver is adopted in SACLA and gets a high evaluation.

Axes 2-axes(Controller Diver)

DeviceNet(ONLINE) Command from the host

USB I/F(OFFLINE) Mechanical adjustment from the PC

pulse frequency 1Hz~1MHz

Number of pulses ±262,143,500(at absolute address)

Resolver signal input ±Sinθ,±Cosθ,R1,R2

Driver specification Drive voltageDC24V,5-phase driver Drive voltage Single-phase100V,5-phase driver

Applicable Motors 0.75~1.4A/phase

Resolving Ability 400,000P/R

1/Divisions 1,2,4,10,20,40,100,200,400,800

Dimensions H146 × W115 × D 200 (mm)/2.8Kg H200× W140× D 230 (mm)/4.6Kg

Supply Power AC100V/AC115V、50/60Hz/1.5A AC100V/AC115V、50/60Hz/7.5A

● cables forcontroller driver

Product name Applicable Model name Remarks

Motor/Sensor H734-00/GDB-5411A-00 H734-03/DSUB15P-40R 4m

cable H743-00/GD-5510E H734-05/DSUB15P-100R 10m

H734-04/DSUB9P-40R 4m

H734-06/DSUB9P-100R 10m

● The stepping motor dedicated of H734-00/GDB-5411A-00 and H743-00/GD-5510E

●Standard motor, you can choose from the geared motor with.

Standard Type

Dimensions

 

Lx□orφ(mm)

Geared Type

Dimensions

Lx□orφ(mm)

weight

A/相 Kg

HoldingTorque

RotorInertia

Basicstepangle

Permissible

Rotational

speed

g・cm2 rpm ゜

Model nameApplicable

Nm

53.5×24.5

H739-01/TS3678N1701 0.13 35 3600 0.72

H739-00/TS3678N900 36000.017 4.2

weight

約0.25 55.5×42

0.72 0.75

Reduction ratio

Basicstepangle

Ratedinputcurrent

0.75

約0.12

Backlash

Gear

maximum

rotational

speed

Nm kg・cm2 min

Allowable

torqueRotorInertia

A/相 Kg

1/50 0.430.0144

0.751.2

x10-2

3.5

97.3×58

1 or less(0.017゚)

1 or less(0.017゚)

72

50 111.3×581/50 0.0144 0.75

191.5×1004.8

1.4 191.5×1004.8

0.53

1.4

1.25

x10-2

0.3

x10-4

1 or less(0.05゚)

160 1/15 0.04824

0.32

x10-4

1 or less(0.05゚)

220 1/11 0.06545

6H739-11/TS3678N1701

-CSF11-50

H739-14/TS3678N1705-CSF11-50

20

3.5

H739-13/TS3678N3401-HPG20-11

H739-12/TS3678N3401-HPG20-15

33

8.5

24

② Resolver cable

24square motor&Resolver

Model name

● by the combination of motor with resolver and driver with the absolute address position management function, it is the case of power ON, returning to the origin will be unnecessary.

Ratedinputcurrent

H734-00/GDB-5411A-0042square motor

&Resolver

Maximum

torque

Nm rpm

86square motor&Resolver&Harmonic

gear

42square motor&Resolver&Harmonic

gear

Applicable

H734-00/GDB-5411A-00

H743-00/GD-5510E

<DeviceNet I/F Motion Control>

(SACLA Facility)

<Connection/other>

Eco cable

Eco cable

●Left product is provided as a controller driver using the core of the GDB series and GD series.

<Motor>

<H734-00/GDB-5411A-00> <H743-00/GD-5510E>

2-axes 2-axes

DeviceNet

USB I/F

・Motor/Sensor /Resolver

H734-00/GDB-5411A-00H743-00/GD-5510ET branch

・Motor/Sensor cable・Resolver cable

1-axis

2-axes

AC100V

6

Page 7: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Other, information about products and services

● Rack cabinet for research facility and research institutions

● 810series option・ Side cover OP-01-01、OP-01-02 etc

・ Rear cover OP-02-01、OP-01-02 etc

・ Guide rail OP-03-01

・ Shelf board OP-04-01

・ Outlet unit OP-05-03、OP-05-04

・ Adjuster bolt OP-06-01

・ Clamp band OP-07-01

・ Shelf board for exclusive OP-08-04、OP-08-05

use of the driver

・ Eyebolt set OP-10-01

・ Fall prevention metal OP-11-01

fittings

・Equipment storage of radiation measuring device ・Network of research facilities

・Equipment storage of biological material analyzer ・Network in the theme park

・Equipment storage of light device certification inspection equipment ・For the data center   etc.

etc.

The latest information on products and servicesis available from the MELEC-INC. website .

<Rack cabinet for the measuring equipment and information network >

700N1 series wide570mm 700NW1 series wide700mm

Rack cabinet for the measuring equipment Rack cabinet for the information network

<Rack cabinet for research facility and research institutions>

●19 inches of steel racks which planned extreme reinforcement

 (there is prevention of fall metal fittings (option))

・ Laboratory equipment storing of the SACLA research facility・ Laboratory equipment storing of the SPring-8 research facility・ Laboratory equipment storing of the research institutions such as universities

melec Stepping Motor Driver

Merit of the maintenance nature whichcan be taken out to the front side.- One driver unit- Every driver shelf board

 Cable of the driver connector part Bunch line example reducing load

・OP-08-04・OP-08-05

●Shelf board for exclusive use of the

810 series

・55-70-180E-B

・55-70-100E

・55-70-80E

・55-70-180E

・Steel rack・20% - 30% of reduction in cost(Our conventional ratio) ・Caster standard features (Four of tire move freely.There is a stopper) ・EIA standard

●Fall prevention metal fittings

55-70-180E Installation example

●55-70-180E-B

The example of mount rail retreat

Implementation

apparatus

The rack front

mount rail retreat

25mm( Normal)

・Rack cabinet for research facility and research institutions

Rack cabinet Product Catalog

URL:http://www.melec-inc.com

7

Page 8: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Other, information about products and services

● MCS (motion control system) using the various master is easily possible to construct (AL-Ⅱ series)

Motion control Product Catalog

URL:http://www.melec-inc.comThe latest information on products and servicesis available from the MELEC-INC. website .

<Motion control by a Personal computer. Other.>

●DC power input/AC power input driver for stepping motor.

●Controller IC for stepping motor and servo motor.

●PC based motion control and I/O control.

●PLC based motion control and I/O control.

●USB I/F MCS Configuration example(AL-Ⅱseries)

UNIT1USB I/F

Extend I/O Unit

(servo motor)

IN/OUT 32/32

UNIT2

(5-phase stepping motor)

Extend I/O Unit

UNIT3( UNIT15(MAX) )

master

Windows7

Device driver(32BIT/64BIT)

AL-Ⅱseres・The number of axes~60axes+IO 480/480point (This can change the axes and I/O points by a combination.)・Wiring distance~Approx 100m(100m or more consultation)

・Ethernet I/F・EtherCAT I/F・PCI BUS・PCI Express BUS

・Slave other than master is ready to be used as it is. For this reason, you can take advantage of the assets of your application program.

Examples of 4-axes control using the USB I/F master.(AL-Ⅱseries)

Mobile PC

USB I/F master

USB I/F

AL-Ⅱ high-speed communication(insulation) Total extension ~ 100m

・PCI BUS

・USB I/F

・PCI Express BUS

・Ethernet I/F

・Various software

・EtherCAT I/F

Slave:10-axes(4-axes controller+seavo、4-axes5-phase stepping moter controller driver+IN/OUT 32/32x2)

USB I/Fmaster

・The master has a lineup for USB I/F,Ethernet I/F,EtherCAT I/F,PCI BUS,and PCI Express BUS.

・Various master

・Device driver   ・C language library   ・Sample program

IN/OUT 32/32

・MCS:モーションコントロールシステム

8

Page 9: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Other, information about products and services

● Promotion of technology development through joint research.

● Proprietany products born in the customer's perspeetive

URL:http://www.melec-inc.com

<Development of the core device>

It can be stopped motor shaft at a "one-400,000th" .Melec Inc. has succeeded in the development of high-precisiontechnology of 0.0009 degrees. And,it was commercialized as GD series.

Currently it offers a GDB series loaded with "one-2,000,000th".Related patents also owns a dozen.

”This is the world that we are working ”

0.00018゚/STEP

(1/2,000,000)

5-phase stepping motor

control command of"one-2,000,000th "

GDB-5F30v1

University Melec inc User

Electrical machinery,Electronics-related

Medical institutions related

Academic research related

Other(Bio/Light equipment/Other)

Jointresearch

Offer

Achievement

Planning

productization

Based on the medium- and long-term themes, it is elements development, applied technology development,and development of the core device, and we are working for the future.Already planning on the basis of the digital technology obtained here, the product of the digital driver,has spread to the adoption of the new applications.

We always aim to develop productsthan meet the previous the requset.The controller IC it has been handeddown to the beginning MCC03,MCC05,MCC07/MCCC08 and MCC09from MCC01.

Core devices of high evaluation,offers the USER as each series products.

1998 2005 2008 2011

Controller IC

MCC05 MCC05V2

MCC06

MCC07

MCC08

MCC09

SACLA/SPring-8(Offer:National Research andDevelopment Agency RIKEN)

SPring-8SACLA

2013

It is adopted in research organization of the National Researchand Development Agency,SPring-8 and SACLA and gets a high evaluation.

Now, it rises to "one-2,000,000th "

●Technology of a "one-400,000th " approved from the research organization of the National Research and Development Agency.

9

Page 10: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Other, information about products and services

SACLA/SPring-8(Offer:National Research and Development Agency RIKEN)

SACLA facilities(Offer:National Research andDevelopment Agency RIKEN)

The undulators.

●SACLA

・H734-00/GDB-5411A-00・H743-00/GD-5510E

Stepping Motorcontroller driver(melec)

The injector outskirts from the accelerationpipe side.

SACLA facilities(Offer:National Research andDevelopment Agency RIKEN)

The acceleration pipe (L band) outskirts thataccelerate an electron.

・H734-00/GDB-5411A-00Stepping Motorcontroller driver(melec)

The acceleration pipe outskirts.SACLA facilities

・H734-00/GDB-5411A-00Stepping Motorcontroller driver(melec)

light source ridge :Front end

SACLA facilities(Offer:National Research andDevelopment Agency RIKEN)

Experiment study ridge :The optics hatch inside

SACLA facilities(Offer:National Research andDevelopment Agency RIKEN)

SPring-8SACLA

<Our product is adopted to SACLA and SPring-8>

SACLA facilities(Offer:National Research andDevelopment Agency RIKEN)

10

Page 11: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Other, information about products and services

SAGA-LS (Offer:Public Interest Incorporated FoundationKyushu synchrotron Light Research Center)

Kyushu synchrotron Light Research Center The Spectroscope and control system of BL10

・H717/GDB-5411A-00・H718/GD-5410・H-584,AD-5610・H-539A

Stepping Motor Driver(melec)

●Control example in SACLA

※19 inches rack cabinets(melec)

・H717-01/GDB-5411A-00・H-539A

Stepping Motor Driver(melec)

<Our product is adopted to Kyushu synchrotron Light Research Center >

●Control example in SPring-8

・H750v1/GDB-5F40・H-539B

Stepping Motor Driver(melec)

(Protein crystal structure analysis beam line)(Kyoto University RISING BL-28XU Beamline -Advanced Basic Science for Battery Innovation)

・H717/GDB-5411A-00・H-539A

Stepping Motor Driver(melec)

SAGA-LS (Offer:Public Interest Incorporated FoundationKyushu synchrotron Light Research Center)

※ ・19 inches rack cabinets (melec) ・Shelf board for exclusive use (melec)

<Our product is adopted to SACLA and SPring-8>

11

Page 12: Research facilities and research institutions …Product Catalog【Research facilities and research institutions】Vol.5.2 Motion control for research facility and research institutions

Product Catalog【Research facilities and research institutions】Vol.5.2

Other, information about products and services

Technical Service

Headquarters system support

E-mail [email protected]

TEL.(042)664-5382 FAX.(042)666-5664

Sales and Service

/TEL.(042)664-5384 FAX.(042)666-2031

516-10,Higashiasakawa-cho,Hachioji-shi,Tokyo 193-0834,Japan

Kyoto office /TEL.(075)959-6888 FAX.(075)959-6889

3-4-34,kaiden,Nagaokakyo-shi,kyoto 617-0826,Japan

Inquiries about rack cabinet

/TEL(042)665-5115 FAX.(042)666-5945

516-10,Higashiasakawa-cho,Hachioji-shi,Tokyo 193-0834,Japan

516-10,Higashiasakawa-cho,Hachioji-shi,Tokyo 193-0834,Japan

URL:http://www.melec-inc.com

This Operating Manual is subject to change without prior notice 711PR0876-4 c1605

for the purpose of product improvement.

Control equipmentsales department

System equipment

ABCDEFISO14001Certification(head office)

<Our product is adopted to DXAFS (time-resolved) in SR center of Ritsumeikan University >

 (Offer:: Ritsumeikan University,Academy of Engineering Sciences ,College of Life Sciences.)

DXAFS (time-resolved)(Dispersion (= wavelength dispersive)XAFS(DXAFS)

UVSOR facility(Offer:Inter-University Research InstituteCorporation National Institutes of Natural Sciences.Institute for Molecular Science)

UVSOR facility

<Our product is adopted to UVSOR Facility >

abcdefISO9001Certification(Control equipment)

UVSOR facility(Offer:Inter-University Research InstituteCorporation National Institutes of Natural Sciences.Institute for Molecular Science)

UVSOR facility