resume ravindra

3
P P a a g g e e 1 1 o o f f 3 3 RESUME RAVINDRA SINGH Mobile: +919660552837/+918955960616 E-Mail: [email protected] Address: 46/547 Din Dayal Awas Kabir Nagar, Raipur, CG. India Age- 40Year (DOB-17Jun 1976) UIDAI No- 5405 1577 4121 A Senior Level graduate Electrical Engineer with an experience of 16 Year 9 Month in Project Management entailing Installation & Commissioning, Maintenance, Operations, Troubleshooting, Quality Control and Team Management in Steel, Power and Solar Plant. Adept in managing Maintenance & operation activities involving resource planning, in-process inspection, team building and co-ordination with internal / external departments. Demonstrated excellence in setting priorities, developing work schedule, monitoring progress towards goals and tracking details/data/information/activities. An effective communicator and possess good experience in building relationships with different country person like USA/France/UK/Germany/China/Russia during work. Organizational Scan Rajasthan Sun Technique Energy Pvt Ltd. (Reliance Power), Dhursar, Rajasthan, India. AREVA Solar India Pvt. Ltd. (Multi National Company of France), Dhursar, Rajasthan, India. Lanco Solar Pvt. Ltd., Chawardhal- Mehroomkhurd, Rajnandgaon, India. Jayaswal Neco Industries Limited (Steel Plant Division), Raipur, India. Raipur Alloys & Steel Limited, (Sarda Energy & Mineral Ltd) Raipur, India. KEY RESULT AREAS Project Management Managing activities right from the conceptualization stage to the execution, involving finalization of technical specifications, procurement, vendor development, scheduling, progress monitoring, site management and manpower planning. Establishing project review, monitoring and status reporting procedures to accurately report progress of the project to the stakeholders and end user clients. Handling activities involving working out various requirements & monitoring overall project operations for ensuring timely completion. Installation & Commissioning Managing installation and commissioning of the heavy equipment’s as well as conducting tests & inspections to ensure operational effectiveness of plant & utilities. Reviewing engineering drawings, layouts, diagrams, technical specifications, cost estimates for erection & commissioning of the plant. Maintenance & Testing Planning and effecting predictive & preventive maintenance schedules for various equipment to increase machine up time & equipment reliability. Identifying areas of bottlenecks / breakdowns and taking steps to rectify the equipment’s through application of troubleshooting tools like root cause analysis. Maintaining and ensuring stringent adherence to quality standards, norms & practices, identifying gaps and taking corrective actions. Carrying out overhauling work of equipment, modifications, and major repairs to improve equipment efficiency by faultfinding. Team Management Leading, mentoring & monitoring the performance of the team members to ensure efficiency in process operations and meeting of individual & group targets. Creating and sustaining a dynamic environment that fosters development opportunities and motivates high performance amongst team members.

Upload: ravindra-singh

Post on 07-Jan-2017

19 views

Category:

Engineering


0 download

TRANSCRIPT

Page 1: Resume ravindra

PPPaaagggeee 111 ooofff 333

RESUME RAVINDRA SINGH Mobile: +919660552837/+918955960616

E-Mail: [email protected] Address: 46/547 Din Dayal Awas Kabir Nagar, Raipur, CG. India Age- 40Year (DOB-17Jun 1976) UIDAI No- 5405 1577 4121 A Senior Level graduate Electrical Engineer with an experience of 16 Year 9 Month in Project Management entailing Installation & Commissioning, Maintenance, Operations, Troubleshooting, Quality Control and Team Management in Steel, Power and Solar Plant. Adept in managing Maintenance & operation activities involving resource planning, in-process inspection, team building and co-ordination with internal / external departments. Demonstrated excellence in setting priorities, developing work schedule, monitoring progress towards goals and tracking details/data/information/activities. An effective communicator and possess good experience in building relationships with different country person like USA/France/UK/Germany/China/Russia during work.

Organizational Scan

Rajasthan Sun Technique Energy Pvt Ltd. (Reliance Power), Dhursar, Rajasthan, India. AREVA Solar India Pvt. Ltd. (Multi National Company of France), Dhursar, Rajasthan, India. Lanco Solar Pvt. Ltd., Chawardhal- Mehroomkhurd, Rajnandgaon, India. Jayaswal Neco Industries Limited (Steel Plant Division), Raipur, India. Raipur Alloys & Steel Limited, (Sarda Energy & Mineral Ltd) Raipur, India. KEY RESULT AREAS Project Management Managing activities right from the conceptualization stage to the execution, involving finalization of technical specifications, procurement, vendor development, scheduling, progress monitoring, site management and manpower planning. Establishing project review, monitoring and status reporting procedures to accurately report progress of the project to the stakeholders and end user clients. Handling activities involving working out various requirements & monitoring overall project operations for ensuring timely completion. Installation & Commissioning Managing installation and commissioning of the heavy equipment’s as well as conducting tests & inspections to ensure operational effectiveness of plant & utilities. Reviewing engineering drawings, layouts, diagrams, technical specifications, cost estimates for erection & commissioning of the plant. Maintenance & Testing Planning and effecting predictive & preventive maintenance schedules for various equipment to increase machine up time & equipment reliability. Identifying areas of bottlenecks / breakdowns and taking steps to rectify the equipment’s through application of troubleshooting tools like root cause analysis. Maintaining and ensuring stringent adherence to quality standards, norms & practices, identifying gaps and taking corrective actions. Carrying out overhauling work of equipment, modifications, and major repairs to improve equipment efficiency by faultfinding. Team Management Leading, mentoring & monitoring the performance of the team members to ensure efficiency in process operations and meeting of individual & group targets. Creating and sustaining a dynamic environment that fosters development opportunities and motivates high performance amongst team members.

Page 2: Resume ravindra

PPPaaagggeee 222 ooofff 333

HIGHLIGHT At Rajasthan Sun Technique Energy Pvt Ltd. (Reliance Power) as Sr.Mgr.(Electrical) (January 2016 to till date) Successfully Planning and Procurement carried out for Man power and resources requirement for operation and maintenance of all the electrical equipment of HT breaker, HT Isolator, Transformer, UPS and LT panel, Platform and gantry of 125MW CSP. Tracking of Daily Activity planning & execution and energy monitoring of Solar block, Power block and 220KV switchyard. Improvement in field of cost saving like in house repair work of costly off-shore item Dunken Motron equipment, Power distribution and energy conservation of plant. Operation and maintenance of Pre Engineering Building equipment 2x750 KVA, 250KVA, 7.5KVA Diesel Generator and Manuel glass loading machine, compressor and robot. At AREVA Solar Pvt. Ltd., Dhursar, India as Electrical commissioning Incharge (Jun 2013 to December 2015) Supervising and monitoring all equipment commissioning, testing and O&M planning (Systematic maintenance plan, Standard operating procedure, History sheet, KPA, MTBF and check list as per OEM) related to 125MW CSP project: 220KV Switch Yard, 133 MW Generators, Transformers up to 160MVA,HT & LT Breaker and motors of 125MW Solar Thermal power plant. Site acceptance test, commissioning and O&M planning of following electrical equipment of 35x25TPH AREVA Concentrated Solar Steam Generators: 6.6KV Megawin-HT switch Gear & Penickker HT Isolator, Voltamp-Dry Transformer,Hirel UPS, LT Panel, HVAC (Voltas), Tractel-30Mtr height Gantry and Platform for Solar steam generator, SSG Line control panel & Reflector control panel and Dunker-Reflector servo control motor and Motorized operating Valve and Variable voltage drive. Successfully coordinated and keep approach for zero punch point and 100% completion of commissioning work by implementing ICAP with Reliance, Alstom, Siemens, Thermax in Power block and Solar field as per Engineering India Ltd and USA engineering. Carried out quality check for all electrical equipment as per PO and specification during Goods inspection. Identify spares for indigenization and list spares to be developed in coordination with operations and maintenance and USA Engineering team. Successfully Planning and Procurement carried out for Man power and resources requirement for project as well as for operation and maintenance of 125MW CSP. Tracking of Daily Activity planning & execution and energy monitoring of Power block as well as of solar field. Improvement in field of cost saving like in house repair work of costly off shore item Dunken Motron equipment, Power distribution and energy conservation of plant. Lanco Solar Pvt. Ltd, Rajnandgaon, CG. India as DY Manager (Electrical) (Feburuary-2011 to Jun 2013)

Operation and maintenance planning and Identify spare for indigenization and list spares to be development at Solar 70MW PV module manufacturing unit. Pivotal in supervising and monitoring all electrical installation, commissioning, testing and updating of drawings related to 1500TPA Polysilicon Project with 5 No’s. 11kv substation and 132kv switchyard. Successfully coordinated and keep approach for zero punch point and 100% completion of erection work and document accordingly with LANCO EPC, GT Solar and Fluor India USA based Engineering Consultant for quality related issues. Factory acceptance test & Site acceptance test of various electrical equipment done at mfr. industries and sites. Electrical reviewing done for Various Hi- technology equipment like CVD reactor, EURO-DIESEL Rotary UPS, HITZINGER DE+M, SANDVIK, Hot Oil, waste water treatment Plant and CHROMOLOX Heaters. Identify manufacturers of the spares and forward the technical drawing to the manufacturers for developing samples of the same / for getting the cost details.

Page 3: Resume ravindra

PPPaaagggeee 333 ooofff 333

At Jayaswal Neco Industries Limited (Power Plant Division) as Assistant Manager (Elect) (February 2011 to Jun 2013) Maintenance and operation of MRSS with 53MW Capital power plant (15x2MW, 7.5x2MW,4x2MW) and plant load of Blast furnace, Arc furnace, DRI, cock oven and Sinter Plant Pivotal in managing 15 MW generator and exciter rewinding and testing work, Transformer up to 50MVA, erection, maintenance and testing work,11KV VCB, up to 220Kv switchyard erection, maintenance and testing work,132Kv switchyard related equipment maintenance. Maintenance and operation of MRSS with 53MW Capital power plant (15x2MW, 7.5x2MW,4x2MW) and plant load of Blast furnace, Arc furnace, DRI, cock oven and Sinter Plant. Captive power plant (15x2MW,7.5x2MW,4x2MW) Generators, exciter and AVR maintenance. Performed system modification work like wireless communication between Grid & AVR, Woodward Panel, etc. Executed erection, commissioning and maintenance of Thermex ESP. Well versed with different types of valve like AUMA & ROTORC make. Executed overall maintenance of Power Plant Equipment like Coal handling plant, Ash handling system, Compressor, Pumps, and Fans. Stellar role in executing Root Cause Failure Analysis, Predictive/Preventive and Breakdown Maintenance. At Raipur Alloys & Steel Limited (Sharda Energy & Minerals Ltd.) as Engineer (Elect) (October 1999 to January 2007) Executed electrical maintenance /commissioning of:

30x3MW Power Plant BTG and BOP . Load Control Management System. Diesel Generator up to 1200 KVA. EOT crane up to 65T & L.T. & H. T. Motor VVVF Drive. 2X100TPD and 2x500TPD Kiln electrical equipment.

Recognized for carrying out project work planning of 15X 4T Induction Furnace like: HT, LT cable scheduling and laying, cable tray scheduling and erection. Commissioning of electrical installation of 15X 4T Induction Furnace. PCC and MCC drawing design and procurement. 11kv VCB erection, commissioning and relay coordination with Power Plant Division. Layout designing for HT breaker, PCC and MCC room. Transformer erection and commissioning including bus bar & bus duct arrangement for 15 x 4 T Induction Furnace of rating 7.5MVA. Transformer, complete testing work including Factory Test and Site Test. Lighting installation, lighting DB and welding DB with dual supply source. Training & Professional skill

Good knowledge of IE Rules and regulations, Electricity Act, Electrical supply code. Familiar with ISO 9001-2000, ISO 14001, ISO 18001, Energy Management ISO 50001. 5 days training on Project management at Lanco Solar, Rajnandgaon, Chhattisgarh. 5 Days Training on Energy management under AIPNPC, New Delhi, India. Electrical safety training (NFPA-70E) done at AREVA Solar, Jodhpur, Rajasthan Academic Credentials

2012 Diploma in management (Operations Management) from IGNOU, India. 2007 B.Tech. Electrical from IASE DU Sardarsahar, (Rajasthan), India. 1998 Diploma in Electrical Engineering from MP Board of Technical Education, Bhopal, India. IT Forte: Good knowledge of MS-Office, Windows XP Professional and Internet Applications.