rezonans enerji İnş.elekt.met.yazılım san.tic.ltd.Şti...

23
Rezonans Enerji İnş.Elekt.Met.Yazılım San.Tic.Ltd.Şti Sultan Orhan Mah. Hasköy San.Sit.No: 16/14 Gebze- KOCAELİ Tel: + 90 262 643 79 93 Mobil: + 90 530 118 0683 Rev :01

Upload: nguyenduong

Post on 27-Aug-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Rezonans Enerji İnş.Elekt.Met.Yazılım San.Tic.Ltd.Şti

Sultan Orhan Mah. Hasköy San.Sit.No: 16/14 Gebze- KOCAELİ

Tel: + 90 262 643 79 93 Mobil: + 90 530 118 0683 Rev :01

REZONANS ENERJİ

2

ENERJİ SANTRALLERİ, İLETİM& DAĞITIM ŞEBEKELERİ, ENDÜSTRİ

TESİSLERİNİN;

Dear Customers,

Our company is composed of experienced staff who have

worked at global company in the design, project, R & D, final

inspection and test department for a long time.

Scientific and technical approach of our firm put forward as the

basis for all the work done and expressed a method based on the

relevant international and national standards and regulations.

Therefore, the purpose of our company in the field of electrical

engineering in solving problems and achieve accurate and true

scientific basis is to offer it as a solution partner to our valued

customers.

Our basic working principle is based on the following principles;

Observation, experiment and test making, the creation of

identification, measuring performance of the Prediction,

controlling system, the establishment of relationships between

events and the technical and scientific aspects needed to

interpret and when necessary it can be falsified.

our vision is to provide the most competitive products and

service in term of quality, price and delivery in order to

contribute to our customers' success at the Power electrical

plants .

Furthermore, environmental concerns, occupational safety and

health are our most important principles.

Best regards,

Atadeniz Demirer

General Manager

Rezonans Energy.

Atadeniz Demirer

General Manager Electrical Engineer ( MBA)

Background: -TEİAŞ- Turkish Electricity Authority

-AEG-ETİ – Tendering and sales Mang

-ALSTOM- Test and Final Cont.Mang.

-AREVA- Operational Site service

Manger

-ELİMSAN- Technical Manager

Mizrap Atalay Technical Manager

Where he worked:

-AEG ETİ- Final Control dep.

-ALSTOM- Final control dep.

-AREVA- Site service supervisor

İlhami Yaman Proje / Sales Manager

-ALSTOM- Final Control dep.

-AREVA- Engineering dep.

-SCHNEIDER- Engineering dep.

Hasan Atila

Manufacturing Manager -AEG ETİ- Manufacturing dep.

-ALSTOM- Manufacturing dep.

-AREVA- Manufacturing dep

-SCHNEIDER- Manufacturing dep.

REZONANS ENERJİ

3

Rezonans enegy is your solution partner regarding concultant, Project service, test and

retrofit of H.V and M.V switchgear and switching devices together staff who have experince

of over 25 years.

Rezonans Energy will provide a major contribution to our customers for the electric power

plant project to find solution to problems with the study of technical, scientific approach

and with respect for the environment.

Our vision

our vision is to provide the most competitive products and service in term of quality, price

and delivery in order to contribute to our customers' success at the Power electrical plants

and provide continuously sustanable development

Mission

Employee safety who Works in power electric system and customer satisfaction will be our

first priority and we are recognized as a company which is based on innovative and

environmental respect.

Our values:

• Customer satisfaction

• Responsibility

• Sincerity & honesty

• İnnovation

• EHS

REZONANS ENERJİ

4

Service Service details

H.V and M.V

Mountimg and

erection/ Test

� H.V & M.V Circuit breaker tests

� H.V & M.V Disconnector tests

� H.V & M.V Current and voltage transformer tests

� H.V & M.V Surge Arrester tests

� Power transformer test

� Protection Relays Test

� M.V Cable tests

Primary and

secondary Project

� Single line Project and secondary Project

� Selection of electrical devices and apparatus according to

network requirement

L.V Control and

protection system

design and test/

mounting

� MCC Control center, Tramvay DC system, Transformer control

panels and fan panels.

� Relay compartment wiring.

Consulting � Power Substation consulting

R&D � M.V Switchgear design and field calculation

Network analysis Short circuit calculation as per IEC & ANSI

Relay coordination and selectivity

Load flow analysis

Transformer sizing

Motor initiation calculation

Harmonic analysis,

Capacitor unit determination

Long term / short

term maintenance

agreement

Power Plant and substation maintenance agreement

REZONANS ENERJİ

5

M.V SWITCHGEAR MOUNTING AND TEST WORKS

GÜÇ TRANSFORMATÖRLERİ

test

DC / AC insulation test

C.B Function test , contact resistance test, timing test

Relay current injection test

CT & VT Test ( turn ratio, % PF)

SCHNEIDER,

ALSTOM,

ABB,

Maintenance: Preventive and corrective maintenance

Ref:

DHMI, ( state air port management)

Çanakkale SERAMİK

REZONANS ENERJİ

6

M.V Circuit Breaker

� AEG

� ALSTOM

� AREVA

� ABB

� ELIMSAN

Ref:

� DHMI- Antalya air port

� Kastamonu entegre

� Sivas Çimento ( cement)

� Suudi Arabia- VXC c.b maintenance

SF6 gases c.b test/

maintenace

� ALSTOM

� SCHNEIDER

� ABB

� ELIMSAN

REZONANS ENERJİ

7

POWER AND DISTRIBUTION TRANSFORMER

Electrical tests:

� % PF test

� TTR test

� Wiring resistance

� DC insulation test

� Capacitance test

Oil test:

� Oil quality test

� Oil dielectric test

( IEC- ANS

� DSG Analysis

� Fault analysis and

reporting

% PF TEST devıce

TTR TEST device

DC RESISTANCE TEST device

REZONANS ENERJİ

8

GENERATOR CIRCUIT BREAKER MOUNTING AND TEST

H.V CIRCUIT BREAKER ERECTION AND TEST

FKG ALSTOM

Ref: ALSTOM- TSG Kalehan ( montaj)

CT & VT ERECTION

AND TEST / MAINTENANCE

REZONANS ENERJİ

9

L.V SWITCHGEAR MOUNTING AND TEST

Tramvay DC şalt tesisleri montaj ve devreye alma çalışmaları

MCC : Mounting , test and start up works

MCC and DC control

system - Tramvay

Ref: Schneider –Ankara

Tramvay system

L.V MCC and Power circuit

breaker maintenace:

Ref:

BOTAŞ ( Natural gas company-

Tekirdağ)

L.V Power circuit breaker

maintenance

REZONANS ENERJİ

10

L.V PANEL MANUFACTURING, MOUNTING, TEST AND START UP

WIRING OF PROTECTION COMPARTMENT OF M.V SWITCHGEAR / FAN PANEL

OF TRANSFORMER

Relay compartment

DEWA Project

SCHNEIDER

Transformer fan

panel

ALSTOM

Hv control panels

154 / 380 kv SS

GIS

Power factor correction panels

REZONANS ENERJİ

11

ENGINEERING

Short circuit calculation as per IEC & ANSI

Relay coordination and selectivity

Load flow analysis

Transformer sizing

Motor initiation calculation

Harmonic analysis,

Capacitor unit determination

Relay configuration

Relay injection test

Relay function test

SVERKER –

REZONANS ENERJİ

12

RETROFIT

Many of today’s electrical power equipment and substations are more than 25 years old and there is the need to extend their

life expentancy is increasing in term of the economic and energy context. That is why, refurbishment or retrofit is necessary

to renew the electrical power substation by replacing the main equipment including HV& MV electrical equipment and

protection relay due to numerical technology and scada needs.

Our expert team can propose a pertinent retrofit offer, which fits the criteria of reliability, adaptability and availability of

each Project regarding power electrical equipments from the site survey to erection with respect enviremental.

Key benefits

• Life extension

• New technology

• Rapid installation

• Complies with International standard IEC standards

• Cost reduction for whole plant

• Customized analysis

• Proposed solution

• •Retrofit realisation

REZONANS ENERJİ

13

Retrofit Works ( dif. Relay + Restrictic earth fault + O/C + Current Transformer changing )

REZONANS ENERJİ

14

TRAINING WORKS

Continuously training and learning organisation.

Empowered personel for technical Works.

Customer training – Metro – Ankara/ Turkey

REZONANS ENERJİ

15

Transformer Maintenance and Tests

Oil tests

Oil insulation test and interpreting Oil dielektric test

% PF test

Dissolved Gas Analyisis report

Electrical test

� % PF tests

� TRR

� DC Insulation

� Winding resistance

� Bushing test

� Capacitance test

Oil Treatment

REZONANS ENERJİ

16

TRANSFORMER FAULT ANALYSIS ( example Works on a fault with DSG) 1- By using DSG

DGA1 DGA2 Artış

CH4 140 195 55

C2H4 85 175 90

C2H2 3 8 5

Total 228 378 150

CO 175 200 25

CO2 1100 2450 1350

Problem Low Energy Discharge (Sparking)

D1 Low Energy Discharge O.K

D2 High Energy Discharge

DT Mix of Thermal & Electrical Faults

T1 Thermal Fault Less than 300 C

T2 Thermal Fault Between 300 C and 700 C

T3 Thermal Fault Greater than 700 C

PD Partial Discharge

According to IEC 60599:

Status H2 CH4 C2H2 C2H4 C2H6 CO CO2 1 TDCG

Condition 1

100 120 35 50 65 350 2,500 720

Condition 2

101-700 121-400 36-50

51-100 66-100 351-570 2,500-4,000 721-1,920

Condition 3

701-1,800 401-1,000 51-80

101-200

101-150 571-1,400 4,001-10,000 1,921-4,630

Condition 4 >1,800 >1,000 >80 >200 >150 >1,400 >10,000 >4,630

Roger Method.

C2H2/C2H4, CH4/H2, C2H4/C2H6

Reported

Atadeniz Demirer

Electrical Engineer.

REZONANS ENERJİ

17

FAULT ANALYSIS FOR ELECTRICAL POWER EQUIPMENT

Diognasis analysis is performed on fault analysis based on engineering taking

into consideration all of power equipment and system requirements.

A)-Defination of problem

1- What is status of existance ?

2- What is the ideal solution?

3- What is the aim of solution

B)- Existance status

1- Collection of data

2- determination of prioraty of parameter

3- Failure of the facts about the past and the present to obtain

C)- Solutions related to the objectives set forth,

D)- Performing root cause analysis

E)- Fulfillment of solutions and improvements,

F)- Controling of results

G)- Reporting of mistakes or failure

REZONANS ENERJİ

18

REZONANS ENERJİ

19

REFERANS ( 2013- 2014)

PROJECT

COMPANY DATE

Antalya Hava limanı 36 KV Şalt tesisi, hücre tadilat ve bakımı

DHM 01.042013

Ankara Metrosu, tramvay cer sistemleri test ve devreye alma çalışmaları

SCHNEIDER 03.05.2013

Katar QVC Trafo Fan panosu imalatı

ALSTOM 12.06.2013

Kenya – 17 KV kompanzasyon ekpertiz çalışması

SCHNEIDER 11.11.2013

Azerbaycan Haydar Aliev Hava limanı

SCHNEIDER 30.08.2013

Simülatör kontrol panosu imalatı

SANLAB 28.06.2013

Azerbaycan projesi O.G devre alma

ELİMSAN 26.08.2013

A.G Kompanzasyon panoları imalatı ve testleri

BBS 01.08.2013

Tüpraş- Koruma rölesi ayarları hizmetleri ELİMSAN 26.08.2013

Antalya hava limanı 6.3 KV hücrelerin elektriksel kilitleme revizyon projelerinin yapılması

DHMI 25.07.2013

Azerbeycan Qubustan projesi saha servis hizmetleri

SCHNEIDER 19.10.2013

Soyak Krister O.G hücre saha montaj suoerviörlüğü

SCHNEIDER 24.12.2013

Winsa O.G hücre ve trafo test ve bakımları

ELİMSAN 04.11.2013

Koç Üniversitesi O.G şalt tesisi montajı

SCHNEIDER 23.12.2013

Piri Reis Universitesi O.G test ve devreye alma

SCHNEIDER 30.01.2013

Atlas Enerji- İskenderun Montaj supervizörüğü

SCHNEIDER 13.02.2014

TPAO – SM6-24 hücrelerin devreye alınması

SCHNEIDER 21.02.2014

36 KV ALSTOM – VXC tipi ark ocağı Vakum kesicisi

SEKONDER ELEKTRİK- AKMAN

31.01.2014

Antalya Hava limanı O.G kesici bakımları DHMI

20.04.2014

Azerbaycan SOCAR tower projesi 24 KV şalt tesisi ve dağıtım trafoları test ve devreye alma hizmetleri

SCHNEIDER 26.05.2014

TEİAŞ Bursa Kastel 12 KV şalt tesisi test ve devreye alma

TRUVA ELEKTRİK 17.03.2014

380 GIS merkezi KV kesici bakımı enerji Zonguldak

ALSTOM 17.03.2014

REZONANS ENERJİ

20

REFERANS ( 2013- 2014)

PROJECT

COMPANY DATE

Trakya döküm Enerji- 154 KV Kesici mekanizma bakımı

ALSTOM 17.03.2014

36 KV şalt hücresi röle gözü retrofit çalışması

ÇANAKKALE ÇAN KALE SERAMİK FAB.

23.03.2014

Yazıcı Demir Çelik -36 & 13.6 KV SS devreye alınması

SCHNEIDER 18.03.2014

İskenderun Atlas Enerji- 36 & 6.3 KV şalt tesisinin devreye alınması

SCHNEIDER 18.03.2014

İla Lojistik- sürücü panosu imalatı İLA LOGİSTİK

25.03.2014

EÜAŞ Kral Kızı – 170 KV SF6 gazlı kesici arıza tespit ve ekspertiz çalışmaları

ALSTOM 28.03.2014

Bolu Çimento- O.G Şalt tesisi test ve devreye alma çalışmaları

ABB 30.04.2014

Elazığ Kalehan jeneratöre kesicisi montaj , test ve devreye alam

ALSTOM 20.04.2014

Ermenistan Copper and molitown plant 170 KV kesici montaj ve test çalışmaları

ALSTOM 28.04.2014

Azerbaycan Shahdag ABB 02.04.2014

Votorantim Çimento –Sivas O.G kesici ve şalt tesisi bakımı

VOTORANTİM ÇİMENTO-SİVAS

03.06.2014

Kastomonu Entg.36 KV O.G Kesici Bakımı

KASTAMONU ENTEGRE 01.06.2014

Aksa Akrilit Yalova- O.G devreye alma SCHNEİDER

09.06.2014

İsdemir-Trafo Fan Panosu imalatı

ALSTOM 10.06.2014

Alçak Gerilim ME Şalter Bakımı BOTAŞ

17.06.2014

ETI SODA – OG şalt

SCHNEIDER 20.06.2014

Güç trafoları Bakımı ÇAYELİ BAKIR İŞLETMELERİ 11.07.2014

Salt tesisi devreye alma

GÖYNÜK ENERJİ- AKSA 21İ07.2014

Şalt ve trafo bakımı

WINSA

22.07.2014

Kale han Güç trafoları fire prevention ve kontrol sistemleri mıntajı

ALSTOM

31.07.2014

Şalt tesisi bakımı ve röle retrofit çalışması

ALSTOM / LINDE 6.08.2014

REZONANS ENERJİ

21

REZONANS ENERJİ

22

RESPECT TO ENVIROMENT

We are committed to HUMAN HEALTH AND SAFETY

We respect to our PLANET

Rezonans Enerji İnş.Elekt.Met.Yazılım San.Tic.Ltd.Şti

Sultan Orhan Mah. Hasköy San.Sit.No: 16/14 Gebze- KOCAELİ

Tel: + 90 262 643 79 93

Mobil : + 90 530 118 0681 -Teknik Md.’lük

REZONANS ENERJİ

23

: + 90 530 118 0682 - Ticaret Md.’lük

: + 90 530 118 0683 - Genel Md.’ lük