rf0711- m o d e l : s e r i a l # p r o b l e m c a u s e s o l u t i o n "no cool" due to...
TRANSCRIPT
![Page 1: RF0711- M O D E L : S E R I A L # P R O B L E M C A U S E S O L U T I O N "No Cool" Due to Frost](https://reader036.vdocuments.pub/reader036/viewer/2022082601/577c795b1a28abe054925dad/html5/thumbnails/1.jpg)
7/26/2019 RF0711- M O D E L : S E R I A L # P R O B L E M C A U S E S O L U T I O N "No Cool" Due to Frost
http://slidepdf.com/reader/full/rf0711-m-o-d-e-l-s-e-r-i-a-l-p-r-o-b-l-e-m-c-a-u-s-e-s-o-l-u-t-i-o-n-no 1/21
Evaporator builds up frost and ice over time due to defrost heater disengaging too soon.
Termination switch (bi-metal, thermostat) fails to reset under some circumstances or opens
too soon.
Replace termination switch with part number 5304458589 and relocate switch from evapo-
rator outlet tubing to inlet tube.
PLRU1778E, FRU17G4J, and FRU17B2J, All 2006 Models with Serials up toWA638xxxxx
P R O B L E M
C A U S E
S O L U T I O N
M O D E L / S E R I A L #
! " # $ % & " ' ( ) ! *
RF0711
"No Cool" Due to Frost Build-up onEvaporator
PROCEDURE:
1. Unplug refrigerator and remove evaporator cover. If the evaporator is frosted or iced
up, defrost evaporator with a heat gun before servicing refrigerator.
2. Locate termination switch on the left side of the evaporator outlet tube and disconnect
switch from power cord harness and heater. (See Figure 1)
Electrolux Service Flash RF0711 05.01.07
Figure 1. Termination Switch Location
Termination Switch
![Page 2: RF0711- M O D E L : S E R I A L # P R O B L E M C A U S E S O L U T I O N "No Cool" Due to Frost](https://reader036.vdocuments.pub/reader036/viewer/2022082601/577c795b1a28abe054925dad/html5/thumbnails/2.jpg)
7/26/2019 RF0711- M O D E L : S E R I A L # P R O B L E M C A U S E S O L U T I O N "No Cool" Due to Frost
http://slidepdf.com/reader/full/rf0711-m-o-d-e-l-s-e-r-i-a-l-p-r-o-b-l-e-m-c-a-u-s-e-s-o-l-u-t-i-o-n-no 2/22
! " # $ % & " ' ( ) ! *
RF0711
3. Next, wrap the evaporator inlet tube with "ONE WRAP" of vinyl tape (electrical).
(See Figure 2)
4. Install new termination switch to inlet tube and make sure that switch is positioned on
the tape and has no metal-to-metal contact with evaporator tubing. Re-connect electri-
cal wires. (See Figure 3)
5. Replace evaporator cover, and restore power to the refrigerator.
Electrolux Service Flash RF0711 05.01.07
Figure 2. Vinyl Tape Location
Figure 3. Termination Switch Location
"No Cool" Due to Frost Build-up onEvaporator
Evaporator
Inlet Tube
New Termination
Switch