Critical Power. SG Series 10-40 kW Sales Presentation December 2013. Product Range. UPS SG Series 10 kVA PurePulse ® 10kW UPS SG Series 15 kVA PurePulse ® 15kW UPS SG Series 20kVA PurePulse ® 20kW UPS SG Series 30kVA PurePulse ® 30kW UPS SG Series 4 0kVA PurePulse ® 40kW. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: SG Series 10-40 kW Sales Presentation December  2013

© 2012 General Electric Company

1

SG Series 10-40 kWSales Presentation

December 2013

Critical Power

Page 2: SG Series 10-40 kW Sales Presentation December  2013

Page 2 GE Critical Power

SG 10-40 kVA Presentation – 2013

Product Range

UPS SG Series 10 kVA PurePulse® 10kW

UPS SG Series 15 kVA PurePulse® 15kW

UPS SG Series 20kVA PurePulse® 20kW

UPS SG Series 30kVA PurePulse® 30kW

UPS SG Series 40kVA PurePulse® 40kW

CE Marked, 3x380/400/415V In & Out, 50/60Hz

Page 3: SG Series 10-40 kW Sales Presentation December  2013

UPS Configuration

1

Page 4: SG Series 10-40 kW Sales Presentation December  2013

Page 4 GE Critical Power

SG 10-40 kVA Presentation – 2013

Double conversion technologyDesigned for Mission Critical Applications

True On-Line Double Conversion VFI technology

Voltage and Frequency Independent

Inverter output transformer for load galvanic separation

Inverter

DC

Battery bank

AC

ACDC

Static bypass

Rectifier

Bypass supply

LoadRectifier

supply

SG CE classification: VFI – SSS – 111VFI Voltage & Frequency Independent

Frequency Converter operation available

SS Output voltage THD < 8% for all loadsTHDv < 2% linear loadsTHDv < 3% non-linear loads

111 Class 1 performance Exceeding Class 1‘’Best in Class’’ dynamic response:+/- 3% at load step: 0-100%-0+/- 2% at load step: 0-50%-0

Class 1

SG Series

Page 5: SG Series 10-40 kW Sales Presentation December  2013

Page 5 GE Critical Power

SG 10-40 kVA Presentation – 2013

UPS configurationDouble conversion with inverter output isolation transformer

Double conversion (VFI) technology with output isolation transformer Automatic bypass for overloads, short circuit and UPS disturbances

conditions Manual bypass for UPS maintenance operations without load

interruption Protection safety devices integrated

- back feed protection K6 standard- battery disconnect CB3 standard

RECTIFIER

SSM

INVERTER

LOA

DSQ1

Q2

CB4

K6

K7

MANUAL BYPASS

AUTOMATIC BYPASS

INP

UT

MA

INS

INVERTERTRANSFORMER

BATTERYCB3

Page 6: SG Series 10-40 kW Sales Presentation December  2013

Page 6 GE Critical Power

SG 10-40 kVA Presentation – 2013

Backfeed protection IEC 62040-1 : ……“For fixed installation UPS, backfeed protection may be provided internally or externally to the UPS in the a.c. input line”

Inverter

DC

Battery bank

ACAC

DC

static bypass

Rectifier

Backfeed contactor

Inputmains

Load

preventing feedback to the mains from the inverter in case of mains failure and a fault in the bypass

circuit

Standard feature inside UPS cabinet No additional cost required No addition installation required

Fully compliant with IEC 62040-1 Compliance to UPS installation

safety requirements

Safer operating condition Safer operation for end users

and service engineers

Page 7: SG Series 10-40 kW Sales Presentation December  2013

Page 7 GE Critical Power

SG 10-40 kVA Presentation – 2013

UPS configurationAdvantages - Output Isolation Transformer

No DC component in output (galvanic isolation by transformer)

Transformer less UPS – DC components are controlled electronically

Lower DC voltage – less number of batteries per string (30-32 blocks)

Less cost for same type of batteries and back up timeTransformer less UPS – More battery blocks,

connections etc Better short circuit capability in battery mode (bypass not available)

Transformer based UPS – 2.7 X Nominal current Ph-Ph- 4 X Nominal current Ph-N / G

Transformer less UPS – 2.2 X Nominal current

No neutral current back to the mains in case of unbalanced load in Double conversion mode

Better management of unbalanced load. A Zig-Zag transformer will share an unbalanced load on the three

inverter bridgesTransformer less UPS – inverter legs may see unbalanced load

( different leg operates at different load % - Components stress level are different) improves battery lifetime through less ripple

Better management of non linear load (low level harmonics are short-circuited)

Page 8: SG Series 10-40 kW Sales Presentation December  2013

Input performance

2

Page 9: SG Series 10-40 kW Sales Presentation December  2013

Page 9 GE Critical Power

SG 10-40 kVA Presentation – 2013

IGBT technology for clean input Pure Pulse® configuration for highest input performances

UPS input performances Total Current Harmonic Distortion

THDi=2% @ 100% load and 5% @ 50% load

UPS input power factor: 0.99

Constant behavior at all loads Negligible harmonics contents at full

and partial loads

Benefit on input mains Saving in the sizing of upfront

equipment'se.g. GenSet, cablings, circuit breakers,

… No disturbances to nearby equipment Saving cost due to additional filters

PurePulse® technology for IGBT rectifier

Total Input Harmonic Distortion

Load0%

1%

2%

3%

4%5%

0% 20% 40% 60% 80% 100%

THD

i

Page 10: SG Series 10-40 kW Sales Presentation December  2013

Page 10 GE Critical Power

SG 10-40 kVA Presentation – 2013

Input rectifier performances Wide input window to preserve battery autonomy and lifetime

Input voltage

Inpu

t fr

eque

ncy

400V +15%-15%

+10%

-10%

50 Hz

Input window

Soft start

100%

0%

UPS input current

time

Wide input voltage and frequency windows

Limited use of battery Preserve battery autonomy for real

input mains failures Increase battery lifetime

Soft start Rectifier can be activated gradually,

controlling the input current Preventing instable situation for

GenSet Avoids false trip of upfront

protection devices Sequential softstart for parallel UPS

UPS 1 UPS 2

Page 11: SG Series 10-40 kW Sales Presentation December  2013

Page 11 GE Critical Power

SG 10-40 kVA Presentation – 2013

Perfect integration with GenSetNo GenSet oversizing required

GenSet integrationCompatible with GenSet designSaving GenSet size

(suggested GenSet vs. UPS ratio ~ 1.1) Reducing GenSet installation spaceSaving GenSet investment

GenSet system integrationGenSet integration via Customer

Interface (dedicated auxiliary contact)Programmable functions based on

GenSet working condition (Gen on/off)

Page 12: SG Series 10-40 kW Sales Presentation December  2013

Output performance

3

Page 13: SG Series 10-40 kW Sales Presentation December  2013

Page 13 GE Critical Power

SG 10-40 kVA Presentation – 2013

Highest UPS output power capabilityCapability to supply Inductive, Resistive and Capacitive loads

Full range power capability Designed to supply real power for

any type of application - inductive loads- resistive loads- capacitive loads

No over-sizing required to supply resistive and capacitive loads

Suitable for modern power supply

application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1

I.e. SG-CE 20kVA load capabilities:Inductive load PF=0.9 18 kW / 20 kVAResistive load PF=1 20 kW / 20 kVACapacitive load PF=0.9 18 kW / 20 kVA

Page 14: SG Series 10-40 kW Sales Presentation December  2013

Page 14 GE Critical Power

SG 10-40 kVA Presentation – 2013

No output voltage distortion with linear and non-linear loads Voltage distortion

- linear loads: THDv <2%- non-linear loads: THDv < 3%

Enhanced customer productivity Improved quality of application,

reducing stress for loads supplied

Increased uptime and MTBF of customer

Reduced service intervention

Output voltage with non-linear load

Output voltage with linear + non-linear load

No output voltage distortion Best in class inoutput dynamic stiffness

output voltage

output voltage

current

current

Page 15: SG Series 10-40 kW Sales Presentation December  2013

Page 15 GE Critical Power

SG 10-40 kVA Presentation – 2013

Medical scanner - dynamic current absorbtion

Best in class in output voltage variation with load steps:Static : < +

1%Dynamic at load steps 0-50-0% : < +

2%Dynamic at load steps 0-100-0% : < +

3%

Enhanced customer unit productivity Improved quality of application

(i.e. medical images)Capability to supply critical loads with

high and fast loads steps (pulsating loads)

Increased uptime and MTBF of customerReduced service intervention

1 ms

Output Dynamic Stiffness Best in class inoutput dynamic stiffness

Voltage variation at 0–100% load step

load step 0-100%output voltage

Page 16: SG Series 10-40 kW Sales Presentation December  2013

Page 16 GE Critical Power

SG 10-40 kVA Presentation – 2013

High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design

High efficiency performancesHigh efficiency > 92% at full and

partial loads for real benefit in operating conditions

Energy cost savingReduced cost of customer equipment

operation at all loads

Air conditioning cost savingReducing size and cost of air condition

systemReducing consumption and related

operating cost

Higher backup time

Page 17: SG Series 10-40 kW Sales Presentation December  2013

Page 17 GE Critical Power

SG 10-40 kVA Presentation – 2013

Superior Battery Management Safe and protected battery management to preserve investment and UPS reliability

Flexible applications Different battery technologies

applicable: PB sealed (VRLA) - PB vented – NiCd

Wide autonomy range: few minutes …... hours

User friendly information Prediction of true back-up time,

based on load status Alarm for “stop operation” to

prevent any unknown shut-down

Monitoring and control Battery test (programmable or

manual) ; preserve UPS system reliability

Battery earth fault detection; safer operation for service engineer &

end user

Charging voltage = f (battery temperature)

2.18

2.21

2.24

2.27

2.30

2.33

2.36

0 5 10 15 20 25 30 35 40

Battery temperature [°C]

Volt

per c

ell

Voltage temperature compensation

V

Page 18: SG Series 10-40 kW Sales Presentation December  2013

Improved serviceabilityHigh Reliability

4

Page 19: SG Series 10-40 kW Sales Presentation December  2013

Page 19 GE Critical Power

SG 10-40 kVA Presentation – 2013

Improved diagnostic, High ReliabilitySG Series – Improved diagnostic, High reliabilityFront access (including battery)Wave form capture capability Fan failure detection AC Capacitor health monitoring Component life time countersDedicated supply path for bypass logic Regulated power supply

Page 20: SG Series 10-40 kW Sales Presentation December  2013

Page 20 GE Critical Power

SG 10-40 kVA Presentation – 2013

Improved diagnostic, High ReliabilitySG Series – Improved diagnostic, High reliabilityRobust RPA communication (Manchester

coded)Simplified design through reduction of

PCBA & connectionsOutput filter capacitors – PCBA mounted,

easy to replace Input & battery circuit breaker instead of

contactorRobust rectifier control with input mains

diagnostic

Page 21: SG Series 10-40 kW Sales Presentation December  2013

Page 21 GE Critical Power

SG 10-40 kVA Presentation – 2013

New FLEX DSP boardExtended modularityImproved diagnostic capabilities

• Black box -> Waveform Capture capability improved diagnostic

• Higher computing capability -> more ability to manage data

Waveform capture

Improved reliability

• Dedicated supply for bypass logic• Dedicated supply for connectivity

channels• Redundant logic for emergency bypass

activation• Main-board integrated RPA control: RPA

board contains only interface hardware• More robust RPA communication

(Manchester coded)

Enhanced connectivity

Common platform

• New digital communication – 3X bandwidth

• Faster connectivity -> up to 10x with connectivity devices hardware upgrade

Page 22: SG Series 10-40 kW Sales Presentation December  2013

Page 22 GE Critical Power

SG 10-40 kVA Presentation – 2013

New FLEX DSP board: the black-box - Option

• Waveform capture, diagnostic and trend analysis• Simultaneous acquisition of 32 channels• Sampling frequency up to 10kHz• Smart trigger capability with up to 16 indipendent trigger

sources to record only specific events with pre/post trigger data acquisition

• Buffer depth of 1000 samples per channel: each event is recorded for 100ms @ s.f. 10kHz

• 8 buffers to record up to 8 events without losing older events – can be extended with external USB mass storage devices

WAVEFORMS• Inverter voltages • Bypass voltages • Input mains voltages • Output voltages: • Output current Phases:• Input capacitors “Cin” voltages:• Inverter primary current: • Input current: • IDC current: • Battery current: • Bypass current:• UDC• Communication status RPA• Auxiliary status• SSM status• Fuses status• Phase error slave master.

Page 23: SG Series 10-40 kW Sales Presentation December  2013

Page 23 GE Critical Power

SG 10-40 kVA Presentation – 2013

EMC - ImmunityImmunitySG-CE products design exceed IEC 62040-2 C3 level for immunity, i.e. can withstand possible disturbances and noise without affecting standard working conditions

Immunity SG-CE immunity level IEC requirements

ESD 8kV (air)4kV (contact)

8kV (air)4kV (contact)

Surge 2kV line to line4kV line to earth

1kV line to line2kV line to earth

Burst 4kV @5kHz 2kV @5kHz

RF common mode (1kHz) 10V 10V

IEC 62040-2 C2 – SG Series 10kVA

Page 24: SG Series 10-40 kW Sales Presentation December  2013

Page 24 GE Critical Power

SG 10-40 kVA Presentation – 2013

Redundant Parallel Architecture True redundancy with no single point of failure

rectifier bypass rectifierbypass

critical load

DCAC

ACDC

battery

Input mains

DCAC

ACDC

battery

Modular designFuture system expansionSaving investment

True redundancyNo single point of failureDecentralized bypassDistributed parallel management

systemRedundancy loss alarm

Increased system reliabilitySafe and reliable power supply for

“mission critical applications”Increase productivityTrue redundancy with no single

point of failure

Page 25: SG Series 10-40 kW Sales Presentation December  2013

Page 25 GE Critical Power

SG 10-40 kVA Presentation – 2013

Back lit Graphic Display (LCD) Multilanguage communication

interface:English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch

Synoptic diagram indicating UPS status Command keys and parameters setting UPS status control LED

Control panel Easy and intuitive interface

LED - redStop Operation

LED - yellowAlarm

LED - greenOperation

Page 26: SG Series 10-40 kW Sales Presentation December  2013

Page 26 GE Critical Power

SG 10-40 kVA Presentation – 2013

Customer interfaceEasy integration with Building Management System (BMS)

UPS supervision capability1x RS232 Serial Communication Port6 programmable potential free alarm

contacts: - D plug - Terminals blocks

1x Emergency Power OFF contact1x Gen-ON Input contact1x Control Input contact

Additional interface:SNMP Interface Card

(10/100Mbps auto-select)MODBUS RTU Interface (RS232 or

RS485)

Page 27: SG Series 10-40 kW Sales Presentation December  2013

Page 27 GE Critical Power

SG 10-40 kVA Presentation – 2013

• Empty Battery cabinets: • Rectifier, Bypass transformer• RPA card, SNMP card, Modbus RTU• iUPSGuard (Remote monitoring)• Black – box capability• 24V DC Power supply• EMC filter class A (40 kVA) the 40kVA is class C2 standard as

well (adding 4x ferrites) • Customer connection kit

Installation flexibility - Product options

Product Options

Page 28: SG Series 10-40 kW Sales Presentation December  2013

Product Comparison

5

Page 29: SG Series 10-40 kW Sales Presentation December  2013

Page 29 GE Critical Power

SG 10-40 kVA Presentation – 2013

Product Comparison

Site pro 10-40 kVA • Rectifier topology – Thyristor based

• Input power factor – 0.8•Input THDi – 30%

•Efficiency – Low at part load•Filter Capacitor – overhang

mounting•Service access – Side for battery•Customer interface – Separate card

SG Series 10-40 kVA • Rectifier topology – IGBT

• Input power factor – 0.99•Input THDi – 2%•Robust control

•Efficiency – Improved by 1-1.5%•Filter Capacitor – PCBA mounting•Service access – Front/Top only•Customer interface – embedded

card

Page 30: SG Series 10-40 kW Sales Presentation December  2013

Page 30 GE Critical Power

SG 10-40 kVA Presentation – 2013

Product Comparison

Site pro 10-40 kVA •Power supply – not regulated AC

power•Battery disconnect – Optional•Cooling system – One blower•No Fan failure detection•No Cooling redundancy •Enhance diagnostic capability – No•Galvanic isolation•No Capacitor monitoring

SG Series 10-40 kVA •Power supply –regulated AC/DC

power•Battery disconnect – Standard CB3•Cooling system – Fans•Fan failure detection•Partial Cooling redundancy •Enhance diagnostic capability•Galvanic isolation•Capacitor monitoring

Page 31: SG Series 10-40 kW Sales Presentation December  2013

Page 31 GE Critical Power

SG 10-40 kVA Presentation – 2013

Product Comparison

Site pro 10-40 kVA SG Series 10-40 kVA

•Cable kit extension available to replace Sitepro without changing cable connections.

Cable connection

Page 32: SG Series 10-40 kW Sales Presentation December  2013

Page 32 GE Critical Power

SG 10-40 kVA Presentation – June 2013

32

Clean Input < 5% THDiInput pf – 0.99Wide input voltage

Saving in the sizing -Input Breaker-Input cables

Saving in the sizing - Genset

-Enhance battery life

Output pf –1.0 (lead to lag)

Output V THDv <2%- Reduce stress on load

- Stiff bus for pulsed loads

- More Output power

High Efficiency > 92%

New SG Series.... high performances UPSOutput isolation

transformer- Increased reliability - Better short circuit cap

Low Total Cost of Ownership

-Inbuilt back feed protection

Page 33: SG Series 10-40 kW Sales Presentation December  2013

© 2012 General Electric Company

33

SG 10-40 kVA - Applications

Large railway organizations

Process industries

Control systems Healthcare

Page 34: SG Series 10-40 kW Sales Presentation December  2013

Page 34 GE Critical Power

SG 10-40 kVA Presentation – 2013

Page 35: SG Series 10-40 kW Sales Presentation December  2013

Page 35 GE Critical Power

SG 10-40 kVA Presentation – 2013

Competitive Comparison

  GE Socomec Riello Riello Liebert  SG 10-40 kVA Masterysy Master MPS Multisentry NXCTechnology Tx based Tx based Tx based Tx less with internal option Tx less with internal optionPower range 10-40 10-40 (up to 80) 10-800 10-40 (upto 120) 10-40Input PF 0.99 0.99 0.92 0.99 0.99Input THDi < 3% < 3% < 5-7% <3% < 4%Output PF 1 0.9/0.8 0.9 0.9 0.9Efficiency 92% ? 92 ? up to 94% ? 92.5% (with Tx)IP degree of protection 20 31 20 20 (31 option) 20Input/output 3/3 3/3 & 3/1 3/3 & 3/1 3/3 & 3/1 (20 kVA) 3/3 & 3/1 (20 kVA)Back-feed Standard Optional Optional Optional Foot Print 680 x 800 x 1450 mm 600 x 800 x 1400 mm 555 x 740 x 1400 440 x 850 x 1320 500 x 860 x 1240 1000 x 835 x 1400 mm (40kVA) Internal Batt upto 20kVA 600 x 850 x 1600 (30-40 kVA) Internal battery upto 40 kVA Internal Batt upto 30kVA Serviciability Front access Front access Front access Front and back access Front access