    Product Data SheetEdition 11.2006Version no. 08.06

    1/3

    Co

    nstruct

    ion

    SikaplanPP-9.6

    Sikaplan

    -9.6Sheet waterproofing membrane

    ProductDescription

    Sikaplan-9.6 is an unreinforced plasticized PVC membrane.

    Uses Waterproofing of all kinds of below ground-structures

    Lining of ponds and channels for clean water

    Characteristics /Advant ages

    High resistance to ageing

    High tensile strength and elongation

    Resistant to root penetration and micro-organisms

    Resistant to all natural aggressive mediums in ground water and soil

    High water vapour transmission ability

    High resistance to mechanical impact

    High dimensional stability

    High flexibility in cold temperatures

    Hot air and solvent weldable

    Suitable for installation on compacted soil

    Suitable for soft water (aggressive to concrete)

    Suitable for installation over weak substrates (pull-out strength < 1.5 N/mm2)

    Can be installed on damp or wet substrates

    Tests

    Approval / Standards Conforms to DIN 16 730 / DIN 16 938.

    Product Data

    Form

    Appearance / Colours Rolled sheet membrane, unreinforced.

    Surface: smoothMembrane thickness: 1.50 mm

    Colour:Top layer: yellow greyBottom layer: black

    Packaging Roll size: 2.20 m (roll width) x 20.00 m (roll length).

    Unit weight: 1.95 kg/m2

    Storage

    Storage Conditions /Shelf-Life

    Rolls should be stored in a horizontal position and protected against direct sunlight,rainwater, snow and ice etc.

  • 7/27/2019 Sika Plan 9.6

    2/3

    2/3SikaplanP

    Technical Data

    Chemical Base Soft PVC (PVC-p-NB) unreinforced.

    Thickness > 1.50 mm (according to DIN 53353)

    Water Vapour DiffusionResistance

    < 24'000 (according to DIN 53122)

    Mechanical / PhysicalProperties

    Tensile Strength Longitudinal and transversal:> 15.89 N/mm

    2 (according to DIN EN ISO 527-3)

    Elongation Longitudinal and transversal:> 313% (according to DIN EN ISO 527-3)

    Seam Strength Cracks occur next to the seam. (according to DIN 16726)

    Behaviour underHydrostatic Pressure

    Watertight at 4 bar over 72 hours. (according to DIN 16726)

    Puncture Resistance Watertight at a drop height of 300 mm. (according to DIN 16726) (drop-weight of 500 gms)

    Dimensional Changeafter Storage at +80C

    < 2.63% (according to DIN 53377)

    Behaviour when Foldingin Cold

    No cracks at -35C. (according to DIN 53361)

    Resistance

    Appearance afterStorage in Heat

    No blistering, cracks or capillaries. (according to DIN 53377)

    SystemInformation

    System Structure Ancillary Products:

    - Sika-Trocal

    PVC - coated metal sheets (Type S) for fixing pieces.

    - Sika

    Disc, PVC-roundel, dia..75 mm for fixing pieces.- Sika

    Waterbar, Type AR and Type DR for fixing pieces and waterproofing

    concrete joints.

    Appl ication Detai ls

    Substrate Quality In-situ concrete:Clean, sound and dry, homogeneous, free from oils and grease, dust and loose orvariable particles.

    Shotcrete:The profile of the shotcrete surface must not exceed a ratio of length to depth of5 : 1 and its min. radius should be 20 cm. The shotcrete surface must not containbroken aggregates. Any leaks must be sealed with Sika

    waterproof plugging

    mortar, or drained with a SikaFlexo-Drain. Where necessary to achieve the

    desired profile/surface, apply a fine gunite layer on the shotcrete surface with a min.thickness of 5 cm minimum and aggregate diameter not exceeding 4 mm. Steel(girders, reinforcement mesh, anchors etc.) must also be covered with a minimum5 cm of gunite.

    The surface of the shotcrete and gunite must be cleaned (no loose stones, nails,wires, etc.).

    Appl ication Conditions /Limitations

    Substrate Temperature 0C min. / +35C max.

    Ambient Temperature +5C min. / +35C max.

  • 7/27/2019 Sika Plan 9.6

    3/3

    3/3SikaplanP

    Appl ication Instructions

    Appl ication Method /Tools

    Installation method:Loose laid and mechanically fastened, or loose laid and ballasted in accordancewith the separate Method Statement for membrane installations.

    All membrane overlaps must be welded i.e. using hand welding guns and pressurerollers or automatic heat welding machines, with individually adjustable andelectronically controlled welding temperatures (such as the manual Leister TriacPID / automatic: Leister Twinny S / semi-automatic: Leister Triac Drive).

    Welding parameters, such as speed and temperature must be established with

    trials on site, prior to any welding works.Notes on Application /Limitations

    Installation works should only be carried out by Sikaapproved contractors.

    The membrane is not resistant to permanent contact with materials like bitumen,and plastics other than PVC; on these it requires a separation layer of geotextile(> 300 g/m

    2).

    The watertightness of the structure must be approved after completion of themembrane installation works according to the requirements of the clientsspecifications.

    The membrane is not UV stabilised and should not be installed on structurespermanently exposed to UV light and weathering.

    Value Base All technical data stated in this Product Data Sheet are based on laboratory tests.Actual measured data may vary due to circumstances beyond our control.

    Local Restrict ions Please note that as a result of specific local regulations the performance of thisproduct may vary from country to country. Please consult the local Product DataSheet for the exact description of the application fields.

    Health and SafetyInformation

    For information and advice on the safe handling, storage and disposal of chemicalproducts, users should refer to the most recent Material Safety Data Sheetcontaining physical, ecological, toxicological and other safety-related data.

    Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of Sikaproducts, are given in good faith based on Sika's current knowledge and experience of the products when

    properly stored, handled and applied under normal conditions in accordance with Sikas recommendations.

    In practice, the differences in materials, substrates and actual site conditions are such that no warranty in

    respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal

    relationship whatsoever, can be inferred either from this information, or from any written recommendations,

    or from any other advice offered. The user of the product must test the products suitability for the intended

    application and purpose. Sika reserves the right to change the properties of its products. The proprietary

    rights of third parties must be observed. All orders are accepted subject to our current terms of sale and

    delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product

    concerned, copies of which will be supplied on request.Co

    nstruct

    ion

    Sika Egypt for Construction ChemicalsEl Abour City1st industrial zone (A)Section # 10 Block 13035,

    Egypt

    Tel :+202- 6100714/15/16/17/18Fax :+202- 6100759Mob :+2012- 3908822/55www.sika.com.eg