slbd s circuito gas. compito – –controlla il flusso del gas al bruciatore principale –...
TRANSCRIPT
![Page 1: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/1.jpg)
SLBD SSLBD SCIRCUITO GASCIRCUITO GAS
![Page 2: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/2.jpg)
• COMPITO– CONTROLLA IL FLUSSO DEL GAS AL
BRUCIATORE PRINCIPALE– MEDIANTE UN COMANDO ELETTRICO
AGLI OPERATORI ON-OFF PUO’ ESSERE APERTO O CHIUSO IL PASSAGGIO DEL GAS ATTRAVERSO LA VALVOLA
• CARATTERISTICHE– MODELLO SIEMENS VGU56– GLI OPERATORI ON/OFF DELLA
VALVOLA GAS AL LORO INTERNO PRESENTANO UN RADDRIZZATORE PERTANTO NON E’ POSSIBILE CALCOLARNE LA RESISTENZA
– RESISTENZA MODUREG 85 OHM
MODUREG
OPERATORE EV1
OPERATORE EV2
VALVOLA GASVALVOLA GAS
![Page 3: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/3.jpg)
• METANO– PRESSIONE MIN. AL BRUCIATORE 1,5 mBAR– PRESSIONE MAX AL BRUCIATORE 13,5 mBAR
• GPL– PRESSIONE MIN. AL BRUCIATORE 3 mBAR– PRESSIONE MAX AL BRUCIATORE 30 mBAR
TARATURA VALVOLA GASTARATURA VALVOLA GAS
![Page 4: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/4.jpg)
• PROCEDURA:
– SOSTITUIRE UGELLI – 14 UGELLI – DA 1,17 PER GAS CH4– DA 0,74 PER GAS GPL
TRASFORMAZIONE GASTRASFORMAZIONE GAS
![Page 5: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/5.jpg)
• PROCEDURA:
– SETTARE LA SCHEDA COMANDO– a) RUOTARE LA MANOPOLA ON/OFF IN ON
PER TRE VOLTE ENTRO DUE SECONDI (fig.1)– b) NEL DISPLAY COMPARIRA’ PER DUE
SECONDI IL TIPO DI GAS SETTATO IN PRECEDENZA (fig.2 esempio nG = metano)
– c) RUTOANDO LA MANOPOLA TEMPERATURA SI SELEZIONA IL TIPO DI GAS
– Ng = metano / LG = GPL– PER MEMORIZZARE RUOTARE LA MANOPOLA
ON/OFF PER TRE VOLTE ENTRO DUE SECONDI.
FIG.1FIG.1
FIG. 2FIG. 2
TRASFORMAZIONE GASTRASFORMAZIONE GAS
![Page 6: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/6.jpg)
• COMPITO– ESPELLERE IN MODO
FORZATO I PRODOTTI DELLA COMBUSTIONE
• DATI– MODELLO FIME– ALIMENTATO A 220 V c.a.– RESISTENZA DI CIRCA 45
OHM
VENTILATOREVENTILATORE
![Page 7: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/7.jpg)
• COMPITO– CONTROLLA
COSTANTEMENTE LA VELOCITA’ DEI PRODOTTI DI COMBUSTIONE
– CREA UN SEGNALE DI DEPRESSIONE AL PRESSOSTATO FUMI
VENTURIVENTURI
![Page 8: SLBD S CIRCUITO GAS. COMPITO – –CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE – –MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE](https://reader036.vdocuments.pub/reader036/viewer/2022070313/5542eb77497959361e8e1cfd/html5/thumbnails/8.jpg)
• COMPITO– TRADUCE IN UN SEGNALE
ELETTRICO LA DEPRESSIONE CREATA DAL VENTURI
– HUBA CONTROL– DA’ IL CONSENSO AD ACCEDERE
IL BRUCIATORE CON UNA DEPRESSIONE SUPERIORE A 8.5mm C.A.
– SPEGNE LA FIAMMA SUL BRUCIATORE CON UNA DEPRESSIONE INFERIORE A 7 mm C.A.
– COLLEGATO ELETTRICAMENTE SOLO IL CONTATTO C-NO
PRESSOSTATO FUMIPRESSOSTATO FUMI