solar cables leaflet feb18 - finolexfinolex.com/wp-content/uploads/2018/03/solar-pvc-cables.pdf ·...

2
393 MTR FINOLEX PV1-F 1X2.5 SQ MM 0.6/1.0 kV AC 0.9/1.8 kV DC 2Pfg 1169/08.2007 TÜV SOLAR CABLES

Upload: others

Post on 14-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SOLAR CABLES Leaflet FEB18 - Finolexfinolex.com/wp-content/uploads/2018/03/Solar-pvc-cables.pdf · 00393 MTR FINOLEX PV1-F 1X2.5 SQ MM 0.6/1.0 kV AC 0.9/1.8 kV DC 2Pfg 1169/08.2007

00393 M

TR

FIN

OLE

X P

V1-F

1X

2.5

SQ

MM

0.6

/1.0

kV

AC

0.9

/1.8

kV

DC

2

Pfg

1169/0

8.2

007

V

SOLA

R C

ABLE

S

Page 2: SOLAR CABLES Leaflet FEB18 - Finolexfinolex.com/wp-content/uploads/2018/03/Solar-pvc-cables.pdf · 00393 MTR FINOLEX PV1-F 1X2.5 SQ MM 0.6/1.0 kV AC 0.9/1.8 kV DC 2Pfg 1169/08.2007

00393 M

TR

FIN

OLE

X P

V1-F

1X

2.5

SQ

MM

0.6

/1.0

kV

AC

0.9

/1.8

kV

DC

2

Pfg

11

69

/08

.20

07

V

SOLAR PV CABLES FOR PHOTOVOLTAIC SYSTEMS

APPLICATIONThese cables are connected between individual modules and the string combiner box

(Junction).

Solar energy is the most abundant source of energy on our planet. Solar energy is converted

in to electrical energy by means of arrays of Photovoltaic modules. Specially designed

Photovoltaic cables are used in these modules. •High Thermal Rating to withstand extreme temperatures

•Specially designed to withstand extreme weather conditions

•Excellent resistance to heat pressure

•Excellent abrasion and notch resistant

•RoHS compliant

ADVANTAGES

CURRENT CARRYING CAPACITY AND DIMENSIONS:

2.5

4

6

10

16

25

35

8.21

5.09

3.39

1.95

1.24

0.795

0.565

Conductor Resistance

o /km@ 20 C, Max.

Current carrying capacity Amp.

On surface. Two cables adjacentIn air. Single cable

41

55

70

98

132

176

218

On surface. Single cable

39

52

67

93

125

167

207

33

44

57

79

107

142

176

Area Sq. mm

Overall Diameter mm (approx.)

As per standard 2Pfg 1169

5.0

5.5

6.0

7.0

8.0

10.5

11.5

As per standard 2Pfg 1990and EN 50618

6.5

7.0

7.5

8.6

9.9

11.4

12.5

Ω

* Conductor - to - Conductor, ** Conductor - to - Earth

Parameter

Rated Voltage -  AC ( Uo/U )

DC ( C - to - E)**

Maximum Permissible Voltage DC ( V )

(Circuit under NO LOAD)

Conductor Material

Conductor Flexibility Class

Insulation & Sheath Material

Max. Temp at conductor

Operating temp range

Thermal Characteristics Performance

Damp Heat

Pressure at High Temp.

Thermal Endurance

Weathering / UV Resistance (According to HD 605/A1)

Performance under fire conditions

Flame Propagation

Halogen Free

Acid / Alkaline Resistance (Oxal Acid, Sodium Hydroxide)

Electrical Chacterstics : in kV

AC Test Voltage - 5 Mins

DC Test Voltage - 5 Mins

AC Spark Test Voltage

Mechanical Characteristics of Insulation & Sheath

Tensile strength

Elongation

Dynamic Penetration

Notch Propogation

Electrolytic, Multi Strand Annealed Bunched Tinned Copper

5

Cross-linked Polyolefin Halogen Free Flame Retardant

0 120 C (20000Hrs), EN 60216-1

0 0- 40 C to 90 C

01000Hrs at 90 C with 85% humidity, According to EN 60068 - 2 - 78

04Hrs at 140 C, According to EN 60811 - 3 - 1

20000Hrs, 50% Residual elongation, According to EN 60216 - 2

According to EN 60332 - 1 - 2

Less than 0.5%, According to EN 50267 - 2 - 1/ -2 IEC 60684 - 2

Tensite strength Variation + 30% elongation min 100%, According to EN 60811 - 2 - 1

6.5

15

10

11

25

12

1.8 kV ( C - to - E)**

Earthed system

1.8 kV ( C - to - C)*

Un-earthed system

2Pfg 1169 / 08.2007TÜV 2Pfg 1990 / 05.12 and EN 50618TÜV

TECHNICAL SPECIFICATIONS

0.6 / 1.0 kV

0.9 kV

Insulation: 6.5 N/mm2, Sheath: 8.0 N/mm2 Min., According to EN 60811-1-1

125 %, Min., According to EN 60811-1-1

Minimum force to penetrate sheath and insulation F (N)

50 x OD 150 x Conductor Dia.

Withstands Voltage test ( half of rated voltage) after Notch propogation.

1500Hrs720Hrs

_

-

1.5 kV

FEB

18

All information given herein is in good faith. Finolex shall not be liable for any damages arising out of incorrect use or interpretation. The Company reserves the right to change any of the above specifications without any prior notice.

For technical literature please contact our Branch Offices:

Ahmedabad: Tel: 079-26584637, 26575639 | Bangalore: Tel: 080 25320176 |

Bhubaneshwar: Tel: 0674-2530053 | Chennai: Tel: 044-28231514, 28284142 |

Chandigarh: Tel: 0172-5076631, 2637334 | Cochin: Tel: 0484-2408930, 2408492 |

Coimbatore: Tel: 0422-2333939/40 | Dharwad: Tel: 0836-2746440 | Goa: Tel: 0832-

2782003, 2782065 | Gurgaon: Tel: 0124-4382304 | Guwahati: Tel: 0361-2490067 |

Indore: Tel: 0731-2802646 | Jaipur: Tel : 0141-2332526/29 | Kolkata: Tel: 033-

24192494, 24192495 | Lucknow: Tel: 0522-2439815, 4035031 | Ludhiana: Tel: 0161-

2804005| Mumbai: Tel: 022-22873252, 22820062 | New Delhi: Tel: 011-23324748,

23353160 | Patna: Tel: 0612-2589835 | Pune: Tel: 020-27475963, 27506200 | Raipur:

Tel: 0771-2885595 | Ranchi: Tel: 0651-2284758 | Roorkee: Tel: 01332-224068 |

Secunderabad: Tel: 040-27721224, 27811161 | Vijayawada, Vadodara, Pondicherry.

In order to derive maximum benefit and utilisation of our products, we advise that these products are stored, installed and commissioned as per the norms prevailing in the place of installation.When decommissioned, these should be disposed using appropriate methods/process specified in respective state / location of use so as not to affect the environment adversely.

AN IS/ISO 9001 CERTIFIED COMPANY26-27, Mumbai-Pune Road, Pimpri, Pune - 411018, India

Tel: 020-27506200 | Fax: 020-27472239Visit us at: www.finolex.com | Email: [email protected]

CIN: L31300MH1967PLC016531