spider ii 8tx 2fx-sm eec

2
 Hirschmann Automation and Control GmbH www.beldensolutions.com  07-12-2014 Page 1 of 2  Product information SPIDER II 8TX/2FX-SM EEC Industrial Ethernet:Unmanaged Industrial Ethernet Switches:SPIDER-Switches:SP IDER II 8TX/2FX- SM EEC http://e-cat alog.hirschmann.com/ link/57078-24455-49855-50103-40587/en/conf/uis tate Name SPIDER II 8TX/2FX-SM EEC  Entry Level Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) Delivery informations Availability available Product description Description Entry Level Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) Port type and quantity 8 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 2 x 100BASE-FX, SM-cable, SC sockets Type SPIDER II 8TX/2FX-SM EEC Order No. 943 958-231 More Interfaces Power supply/signaling contact 1 plug-in terminal block, 3-pin, no signaling contact Network size - length of cable Twisted pair (TP) 0 - 100 m Multimode fiber (MM) 50/125 µm n/a Multimode fiber (MM) 62.5/125 µm n/a Single mode fiber (SM) 9/125 µm 0 - 32,5 km, 16 dB link budget at 1300 nm,  A = 0,4 dB/km, 3 dB reserve, D = 3,5 ps/(nm x km) Single mode fiber (LH) 9/125 µm (long haul transceiver) n/a Network size - cascadibility Line - / star topology  Any Power requirements Operating voltage DC 9.6 V - 32 V Current consumption at 24 V DC max. 330 mA Power consumption max. 8.4 W 28.7 Btu(IT)/h Service Diagnostics LEDs (power, link status, data, data rate) Redundancy Redundancy functions n/a Ambient conditions Operating temperature -40 ºC to +70 ºC Storage/transport temperature -40 ºC to +85 ºC Relative humidity (non-condensing) 10% to 95% MTBF 55.7 years MIL-HDBK 217F: Gb 25ºC Mechanical construction Dimensions (W x H x D) 35 mm x 138mm x 121 mm Mounting DIN Rail 35 mm Weight 260 g Protection class IP 30 Mechanical stability IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks IEC 60068-2-6 vibration 3,5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. EMC interference immunity EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge

Upload: jorge-nunez-melgar-chirinos

Post on 13-Apr-2018

227 views

Category:

Documents


0 download

TRANSCRIPT

7/26/2019 Spider II 8tx 2fx-Sm Eec

http://slidepdf.com/reader/full/spider-ii-8tx-2fx-sm-eec 1/2

Hirschmann Automation and Control GmbH www.beldensolutions.com

  07-12-2014

Page 1 of 2 

Product information

SPIDER II 8TX/2FX-SM EEC

Industrial Ethernet:Unmanaged Industrial Ethernet Switches:SPIDER-Switches:SPIDER II 8TX/2FX-SM EEC

http://e-catalog.hirschmann.com/link/57078-24455-49855-50103-40587/en/conf/uistate

Name SPIDER II 8TX/2FX-SM EEC

 

Entry Level Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)

Delivery informations

Availability available

Product description

Description Entry Level Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)

Port type and quantity 8 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 2 x 100BASE-FX, SM-cable, SC sockets

Type SPIDER II 8TX/2FX-SM EEC

Order No. 943 958-231

More Interfaces

Power supply/signaling contact 1 plug-in terminal block, 3-pin, no signaling contact

Network size - length of cable

Twisted pair (TP) 0 - 100 m

Multimode fiber (MM) 50/125 µm n/aMultimode fiber (MM) 62.5/125 µm n/a

Single mode fiber (SM) 9/125 µm 0 - 32,5 km,

16 dB link budget at 1300 nm,

 A = 0,4 dB/km, 3 dB reserve, D = 3,5 ps/(nm x km)

Single mode fiber (LH) 9/125 µm (long haul

transceiver)

n/a

Network size - cascadibility

Line - / star topology  Any

Power requirements

Operating voltage DC 9.6 V - 32 V

Current consumption at 24 V DC max. 330 mA 

Power consumption max. 8.4 W 28.7 Btu(IT)/h

Service

Diagnostics LEDs (power, link status, data, data rate)

Redundancy

Redundancy functions n/a

Ambient conditions

Operating temperature -40 ºC to +70 ºC

Storage/transport temperature -40 ºC to +85 ºC

Relative humidity (non-condensing) 10% to 95%

MTBF 55.7 years MIL-HDBK 217F: Gb 25ºC

Mechanical construction

Dimensions (W x H x D) 35 mm x 138mm x 121 mm

Mounting DIN Rail 35 mm

Weight 260 g

Protection class IP 30

Mechanical stability

IEC 60068-2-27 shock  15 g, 11 ms duration, 18 shocks

IEC 60068-2-6 vibration 3,5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;

1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge

7/26/2019 Spider II 8tx 2fx-Sm Eec

http://slidepdf.com/reader/full/spider-ii-8tx-2fx-sm-eec 2/2

Hirschmann Automation and Control GmbH www.beldensolutions.com

  07-12-2014

Page 2 of 2 

Industrial Ethernet:Unmanaged Industrial Ethernet Switches:SPIDER-Switches:SPIDER II 8TX/2FX-SM EEC

http://e-catalog.hirschmann.com/link/57078-24455-49855-50103-40587/en/conf/uistate

EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)

EN 61000-4-4 fast transients (burst) 2 kV power line, 4 kV data line

EN 61000-4-5 surge voltage power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line

EN 61000-4-6 conducted immunity 10 V (150 kHz - 80 kHz)

EMC emitted immunity

FCC CFR47 Part 15 FCC CFR47 Part 15 Class A 

EN 55022 EN 55022 Class A 

Approvals

Safety of industrial control equipment cUL 508

EMV regulations for assembly in vehicles n/a

Employment in vehicles E1

Scope of delivery and accessories

Scope of delivery Device, terminal block, operating manual

Accessories to order separately Rail power pupply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame

For more information please contact:

Hirschmann Automation and Control GmbH

Stuttgarter Strasse 45-51

72654 Neckartenzlingen

Germany

Phone: +49 7127/14-1809

E-Mail: [email protected]

 

The information published in the websites has been compiled as carefully as possible. It is subject to alteration without notice in technical as well as in price-related/commercial respect.

The complete information and data were available on user documentation. Mandatory information can only be obtained by a concrete query.