Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C , Y. Ajima A , N. Fukasawa AD , K. Ishibashi B , Y. Kuno C , T. Miura A , K. Nakahara C , T. Nakamoto A , N. Nosaka C , M. Numajiri A , A. Sato C , N. Shigyo B , A. Yamamoto A , T. Yokoi A and K. Yoshimura A KEK A , Kyushu University B , Osaka University C , Tokyo University of Science D

Upload: elisabeth-reynolds

Post on 13-Jan-2016

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Study of Pion Capture Solenoids for PRISM

H.Ohnishi AB

M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C,

T. Miura A, K. Nakahara C, T. Nakamoto A, N. Nosaka C, M. Numajiri A,A. Sato C, N. Shigyo B, A. Yamamoto A, T. Yokoi A and K. Yoshimura A

KEK A, Kyushu University B, Osaka University C, Tokyo University of Science D

Nufact’03 June 7, 2003

Page 2: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Outline • Introduction

– Pion capture solenoid for PRISM

• A Model Experiment to Measure Radiation Heat Load– Experimental set up– Measurement– Results– Comparison with simulation results (MARS)

• Further R&D plan• Summary

Page 3: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Pion Capture Solenoid for PRISM• PRISM needs the SC solenoid req

uired a high field (Bc = 6~12 T)– Keep the solenoid at low temperature

• The solenoid is heated by radiations from the target

• To reduce the radiation heat load, thick radiation shield is needed

• We estimate the radiation heat load with simulation code MARS, but the accuracy of simulation results have not been studied

50GeV protons 750kW

SC SolenoidShield

We experimentally evaluate the accuracy of simulation results.PRISM

Pion capture solenoid

Page 4: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

A Model Experiment to Measure Radiation Heat Load

• Radiation heating in a model solenoid (mockup) was precisely measured

• The experimental results were compared with the result obtained by MARS

Page 5: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Experimental Conditions(KEK 12GeV-PS)

Beam parameters– 12 GeV proton– Intensity ~1011 (protons/sec)– Slow extraction

Experimental area– At upstream of EP2-A dump

KEK12GeV-PSmain ring

Beam DumpExperimental

area

1 mEP2

A-line

Page 6: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Experimental setup

12GeV primary protons 1011(p/s)

• Sensitive measurement of radiation heat load to the mockup with the cryo-calorimeter

Page 7: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Experimental Installation

Beam dump12GeVPSprimary protons

12GeV ~1011(p/s)

Beam Dump

Experimental area

Mockup

240 mm

Cryostat

Page 8: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Profile & Intensity of Primary Protons

Cu foil area (mm)

intensity

(protons/sec)

fraction (%)

20 6.70 (0.45) 1010

99.92

20_30 3.14 (0.26) 107

0.05

30_40 1.19 (0.09) 107

0.02

40_50 8.00 (0.77) 106 0.01

Target size 30 →  >99.9 % protons bombard the target

SEC count rate 23.16 (counts/sec) Calibration result 2.89 0.19 (109 protons/count)

MockupTarget (off)

SEC

Cu foil

primary protons

Activate!

Profile of Primary Protons

Page 9: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Highly sensitive measurement by cooling the mockup (20 K)

• Highly sensitive thermometers (resolution < 20 mK)

• Quick response because of small specific heat

Mockup temperature rise up T = Q Kat thermal equilibrium state

Q : Heat load

K : Thermal conductance determined by thermal shunt

Thermal shunt determines the relation between mockup temperature and heat load

Cryo-calorimeter

Page 10: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Tbeam

Target

Qbeam (W)

GM cryocoolerMockup

Thermal shunt

Thermometer

MockupMockup

Heater

Tbeam

Thermal equilibrium state!

Mockup

Heater Qhe

ater(W)

Mockup temperature

Qbeam

Qheater time

Theater

Tbeam = Theater

Qbeam = Qheater

How to Measure Radiation Heat LoadThermal equilibrium state!

Theater

Page 11: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Typical Experimental Data

Tbeam = Theater →   Qbeam = Qheate

r

Qheater

Qbeam

Thermal balance Theater

Thermal balance Tbeam

Target on / off

Target off

Heater on

cryo cooler

proton beam

Target on Heater off Target on

heater

Page 12: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Experimental Results

Target position (mm)

Radiation heat load (W at 1011 protons/sec)

-80 0.34 0.02

0 0.88 0.06

80 1.42 0.10

12GeV

primary protons

080 -80Target position

Overall error is nearly equal to 7 %

Page 13: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Comparison with simulation results

12GeV

primary protons

080 -80Target position

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

-100-50050100Target position from mockup center(mm)

Rad

iati

on h

eat l

oad

(W a

t 10

11pr

oton

s/se

c)Experimental results

MARS calculationstatistical error < 2%

Overall error < 7%

Page 14: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Experimantal Summary

• We have performed direct measurement of radiation heat load.

• Experimental results are 20-30% higher than simulation results

• Experimental results show the consistent dependency with simulation.

Page 15: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Further R&D Plan forPRISM Capture Solenoid

Page 16: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Base-line Parameters for PRISM Capture Solenoid

• Boundary condition– The maximum transverse momentum

Pt = 300 B R/2= 90 MeV/c

• Central field Bc = 6 T

• Effective bore R = 0.1 m

Page 17: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Solenoid Parameters

• Parameters– Central field 6 T– Coil length ( 2 target length) 1.6 m– Stored energy / solenoid mass ratio 1

0 kJ/kg– Solenoid inner radius x – Al stabilized NbTi cable

• Radial thickness– Beam pipe 0.1 m– Radiation shield f(x)– Vacuum insulation 0.05 m

Page 18: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Radiation Heat Load & Stored energy vs. Solenoid radius

50GeV protons (750kW)

Materials•Target C(graphite)•Shield W•Solenoid Al stabilized NbTi

Page 19: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Preliminary design Parameters

PRISM

Central field(T) 6

Shield thickness(m)

0.25

Solenoid radius(m) 0.45~0.55

Length(m) 1.6

stored energy(MJ) 16

Heat load(W) 470

Page 20: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Small Size R&D Solenoid

PRISM R&D(1/2.5scale)

Central field(T) 6 3~6

Shield thickness(m)

0.25 -

Solenoid radius(m) 0.45~0.55 0.2~0.24

Length(m) 1.6 0.4~0.6

stored energy(MJ) 16 0.5~1

Heat load(W) 470 470/(2.5)3 = 30

R&D solenoid

Page 21: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Summary

• We have performed direct measurement of radiation heat load

• Experimental results are 20-30% higher than simulation results

• Experimental results show the consistent dependency of target position with simulation

• We are planning R&D with a small size solenoid

Page 22: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Error Breakdown

(%)

* T.Asano et al, 'Target dependence of charge distributions in spallation reactions of medium-mass nuclei with 12GeV protons' , Phys. Rev. C 28, 1718(1983)

Target position (mm) -80 0 80

*12GeV proton – Cu 24Na production cross section

5.1 5.1 5.1

Ge detector efficiency 4.3 4.3 4.3

Fluctuation of beam intensity 2.1 0.8 1.3

Measurement of heat load <1 <1 <1

Total error 7.0 6.8 6.8

Page 23: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Mockup & Target

Target

Mockup• Mockup

– Made of copper– Set resistive heater

• Thermometer– High sensitivity at low

temperature– Four terminal

measurement• Target

– 0.2 interaction length– Movable– Made of copper

130

170

180

280

240

30

30

C20

Resistive heaterThermometer

Page 24: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Heat load measurement has need to thermal equilibrium stateTarget position move to up-stream

higher radiation heat loadMany secondary particles fly out forward

Typical Experimental Data

ABC

A B C

12GeV protons (<200W)

Page 25: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Difference between Tbeam and Theater

Difference between Tbeam and Theater < 0.15K

T bea

m &

The

ater

Page 26: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Plot Qheater vs.Theater

115.35

0.07heater heaterT Q

T = Q

Page 27: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Correcting Qbeam with difference between Tbeam and Theater

Effect of the difference between Tbeam and Theater < 1%

Qheater Qbeam

Page 28: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Fluctuation of Beam IntensityQ

hea

ter

Qbe

a

m

TheaterTbeam

Fluctuation of beam intensity (protons/10min) < 3%

Mockup temperature

Beam Intensity

Page 29: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Tbeam & Theater at Various Thermometer

T = Tbeam - Theater

cryocoolerMockup

TCold TShI-L TShI-H

TMoI-L  

TMoI-H

Qhe

ater

Qbe

am

TCold

TShI-L

TShI-H

TMoI-L &TMo

I-HTbeam

Theater

Page 30: Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T

Effect of Outside Mockup

Qhe

ater

Qbe

am

TheaterTbeam

Temperature of outside mockup is nearly constant.

Effect of outside mockup to Tbeam & Theater hardly changed.

Tbeam

Theater