test report€¦ · merkez mahallesi sanayi cad. no.23 altindag plaza yenibosna 34197 - istanbul /...

46
. TEST REPORT Page 1 of 46 Beril SEN Sinan Öncel COORDINATOR CUSTOMER CARE MANAGER Intertek Test Hizmetleri A.S. Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : [email protected] www.intertek-cg-tur.com *130111122* 130111122 ebru.aslan REPORT NUMBER : TURT130111122 APPLICANT NAME Ceren Kağıt ve Kırtasiye San. A.Ş. ADDRESS Ziya Gökalp Mah. Eski Turgut Özal Cad. Haseyad İş Merkezi İ.O.S.B Başakşehir / İstanbul TURKEY FAX NO :0212 407 06 66 Attention :Berçem Keresteci ([email protected]) BUYER NOT GIVEN SAMPLE DESCRIPTION : Sample 1 Two samples of Eva hoby set foam picture art with picture guide&foam stickers / BU- BU00079 - CA9246ABCDEF Sample 2 Two samples of Mosaic hoby set sparkle mosaic art mosaic picture&adhesive mosaic tiles / BU-BU00080 - CA8922 Sample 3 Two samples of pon pon hoby set pompom art with picture base adhesive paper and pom poms / BU-BU00076 - CA8396ABCD Sample 4 Two samples of Eva hoby set foam art with picture guide&foam stickers / BU-BU00077 - CA9260 Sample 5 Two samples of Silverly poufs glitter loop&curl with adhesive picture design glitter and chenilles / BU-BU00078 - CA9259 DATE IN : 19 July, 2013 (15:58) DATE OUT : 30 July, 2013 COUNTRY OF ORIGIN: CHINA ITEM NO: BU-BU00079 - CA9246ABCDEF / BU-BU00080 - CA8922 / BU-BU00076 - CA8396ABCD / BU-BU00077 - CA9260 / BU-BU00078 - CA9259 TEST Sample 1 Sample 2 Sample 3 Sample 4 Sample 5 SAFETY OF TOYS-PART 1:MECHANICAL AND PHYSICAL PROPERTIES P (Except 7.1) P (Except 7.1) P (Except 7.1) P (Except 7.1) P (Except 7.1) SAFETY OF TOYS-PART 2:FLAMMABILITY P P P P P TOXIC ELEMENTS ANALYSIS P P P P P P = MEETS BUYER' S REQUIREMENT / F = DOES NOT MEET BUYER' S REQUIREMENT / NR = NO REQUIREMENT / SC=STILL CONTINUES / X=NOT PERFORMED / NA = NOT APPLICABLE/ LS : LACK OF SAMPLE The test results relate only to the items tested. The whole and/or the part of this test report shall not be reproduced and shall not be shared with third parties, nor to be used for PR activities without the written permission of INTERTEK Test Hizmetleri A.S. The reported uncertainity is based on a standard uncertainity multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%. The uncertainity evaluation has been carried out in accordance with ISO/IEC 17025 and UKAS accreditation requirements. Unless otherwise is specified, all Pass or Fail results are given without uncertainity considered. When uncertainity is taken into account, the result may be borderline. Borderline results need to be re-tested to determine their disposition up to customer’s decision. Opinions and interpretations expressed herein are outside the scope of UKAS accreditation. Tests marked (*) in this test report are not included in the UKAS accreditation schedule for this laboratory.

Upload: others

Post on 29-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

TEST REPORT Page 1 of 46

Beril SEN Sinan Öncel COORDINATOR CUSTOMER CARE MANAGER

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Y enibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

*130111122* 130111122

ebru.aslan

REPORT NUMBER : TURT130111122

APPLICANT NAME Ceren Kağıt ve Kırtasiye San. A. Ş.

ADDRESS Ziya Gökalp Mah. Eski Turgut Özal Cad. Haseyad İş Merkezi İ.O.S.B Başakşehir / İstanbul TURKEY FAX NO :0212 407 06 66

Attention :Berçem Keresteci (bercem@cerenkirtasiye .com.tr)

BUYER NOT GIVEN

SAMPLE DESCRIPTION : Sample 1 Two samples of Eva hoby set foam picture art with picture guide&foam stickers / BU-

BU00079 - CA9246ABCDEF Sample 2 Two samples of Mosaic hoby set sparkle mosaic art mosaic picture&adhesive mosaic tiles /

BU-BU00080 - CA8922 Sample 3 Two samples of pon pon hoby set pompom art with picture base adhesive paper and pom

poms / BU-BU00076 - CA8396ABCD Sample 4 Two samples of Eva hoby set foam art with picture guide&foam stickers / BU-BU00077 -

CA9260 Sample 5 Two samples of Silverly poufs glitter loop&curl with adhesive picture design glitter and

chenilles / BU-BU00078 - CA9259

DATE IN : 19 July, 2013 (15:58)

DATE OUT : 30 July, 2013

COUNTRY OF ORIGIN: CHINA

ITEM NO: BU-BU00079 - CA9246ABCDEF / BU-BU00080 - CA8922 / BU-BU00076 - CA8396ABCD / BU-BU00077 - CA9260 / BU-BU00078 - CA9259

TEST Sample 1 Sample 2 Sample 3 Sample 4 Sample 5

SAFETY OF TOYS-PART 1:MECHANICAL AND PHYSICAL PROPERTIES

P (Except 7.1)

P (Except 7.1)

P (Except 7.1)

P (Except 7.1)

P (Except 7.1)

SAFETY OF TOYS-PART 2:FLAMMABILITY P P P P P TOXIC ELEMENTS ANALYSIS P P P P P P = MEETS BUYER' S REQUIREMENT / F = DOES NOT MEET BUYER' S REQUIREMENT / NR = NO REQUIREMENT / SC=STILL CONTINUES / X=NOT PERFORMED / NA = NOT APPLICABLE/ LS : LACK OF SAMPLE The test results relate only to the items tested. The whole and/or the part of this test report shall not be reproduced and shall not be shared with third parties, nor to be used for PR activities without the written permission of INTERTEK Test Hizmetleri A.S. The reported uncertainity is based on a standard uncertainity multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%. The uncertainity evaluation has been carried out in accordance with ISO/IEC 17025 and UKAS accreditation requirements. Unless otherwise is specified, all Pass or Fail results are given without uncertainity considered. When uncertainity is taken into account, the result may be borderline. Borderline results need to be re-tested to determine their disposition up to customer’s decision. Opinions and interpretations expressed herein are outside the scope of UKAS accreditation. Tests marked (*) in this test report are not included in the UKAS accreditation schedule for this laboratory.

Page 2: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 2 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

This report details the clauses appropriate to this item. Those clauses not referred to were considered not applicable.

Specification: BS EN 71-1: 2011- Safety of Toys - S pecification for Mechanical and Physical Properties The item was labelled “Warning! Choking hazard small parts not for children under 3 years.”. The item was tested for children aged over 36 months. The item was packaging in a cardboard box which was considered to be disposable.

Sample 1&2

SECTION TEST RESULTS

4 General Requirements

4.1 Material Pass

4.7 Edges Pass

4.8 Points & Metallic Wires Pass

7 Warning and Instruction for Use

7.1 General

The toy or, its packaging or document accompanying must be labelled with:

- The name and address of the manufacturer.** - Warning and other information should be in the national language(s) of the countries where the toy is marketed.

**In the case of the toy sell in European countries, the toy, its packaging or document accompanying must be labelled with the name and address of the manufacturer and importer.

*The importer name is not clearly pointed out as importer It’s recomended to be identified with the title of ‘importer’.

See Comment

7.2 Toys not intended for children under 36 months

The graphical symbol was found to be incorrect (Too small) as the item bore a suitable text warning this clause is considered to pass however we recommend that the graphical symbol is either corrected or removed from the packaging.

Pass

See Comment

Page 3: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 3 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

This report details the clauses appropriate to this item. Those clauses not referred to were considered not applicable.

Specification: BS EN 71-1: 2011- Safety of Toys - S pecification for Mechanical and Physical Properties The item was labelled “Warning! Choking hazard small parts not for children under 3 years.”. The item was tested for children aged over 36 months. The item was packaging in a cardboard box which was considered to be disposable.

Sample 3&4&5

SECTION TEST RESULTS

4 General Requirements

4.1 Material Pass

4.7 Edges Pass

4.8 Points & Metallic Wires Pass

7 Warning and Instruction for Use

7.1 General

The toy or, its packaging or document accompanying must be labelled with:

- The name and address of the manufacturer.** - Warning and other information should be in the national language(s) of the countries where the toy is marketed.

**In the case of the toy sell in European countries, the toy, its packaging or document accompanying must be labelled with the name and address of the manufacturer and importer.

*The importer name is not clearly pointed out as importer It’s recomended to be identified with the title of ‘importer’.

See Comment

7.2 Toys not intended for children under 36 months Pass

Page 4: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 4 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*)Specification: BS EN 71-2: 2011 Safety of Toys – Flammability Sample 1&2&3&4&5

SECTION TEST RESULTS

4.1 General

Celluloid/cellulose nitrate and materials with a same burning behaviour in fire Pass

Page 5: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 5 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1

1-Multicolor cartoon RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 1.2 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 2.8 ppm PASS 70000

Boron (B) 2 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 6.8 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 44.9 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) < 0.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 6: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 6 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1

2-Red foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 9.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.1 ppm PASS 70000

Boron (B) 1.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 1 ppm PASS 7700

Manganese (Mn) 0.7 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1.9 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 88.7 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 7: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 7 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1

3-Orange foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 10 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.3 ppm PASS 70000

Boron (B) 1.2 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 1.2 ppm PASS 7700

Manganese (Mn) 0.8 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 2.2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 90 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 8: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 8 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1

4-Yellow foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.6 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.7 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.3 ppm PASS 7700

Manganese (Mn) 0.5 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 70.2 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 9: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 9 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1

5-Blue foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.5 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.3 ppm PASS 7700

Manganese (Mn) 0.3 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1.2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 72 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 10: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 10 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

1-Red rhinestones RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.8 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.5 ppm PASS 70000

Boron (B) 0.2 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.1 ppm PASS 7700

Manganese (Mn) 1.4 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 2.8 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) < 0.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 11: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 11 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

2-Blue rhinestones RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.7 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.4 ppm PASS 70000

Boron (B) 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 1.4 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 2.5 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) < 0.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 12: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 12 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

3-Purple rhinestones RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.8 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.2 ppm PASS 70000

Boron (B) 0.2 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.1 ppm PASS 7700

Manganese (Mn) 1.3 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) < 0.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 13: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 13 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

4-Red shinny foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.8 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) < 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 7.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 14: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 14 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

5-Yellow shinny foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) < 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.9 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) < 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 6.8 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 15: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 15 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

6-Green shinny foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.3 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.3 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) < 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1.5 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 16: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 16 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

7-Blue shinny foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.2 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) < 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1.2 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 17: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 17 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

8-Pink shinny foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.7 ppm PASS 70000

Boron (B) 0.3 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.5 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 2.5 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 18: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 18 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2

9-Multicolor cartoon RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.9 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.3 ppm PASS 70000

Boron (B) 0.9 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 6.4 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 46.3 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) < 0.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 19: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 19 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3

1-Multicolor cartoon RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 4.6 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 8.3 ppm PASS 70000

Boron (B) 3.1 ppm PASS 15000

Cobalt (Co) 0.3 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 19.7 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 44.4 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1.2 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 20: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 20 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3

2-Black, white cartoon RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 7.5 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 6.4 ppm PASS 70000

Boron (B) 94.3 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 8 ppm PASS 15000

Nickel (Ni) 0.1 ppm PASS 930

Strontium (Sr) 60 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 0.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 21: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 21 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3

3-Yellow foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.3 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.4 ppm PASS 70000

Boron (B) 0.2 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.4 ppm PASS 7700

Manganese (Mn) 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 2.4 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 22: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 22 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3

4-White foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) < 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.2 ppm PASS 70000

Boron (B) 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.3 ppm PASS 7700

Manganese (Mn) < 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 2 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 23: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 23 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3

5-Blue foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.7 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.9 ppm PASS 70000

Boron (B) 0.8 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 7.7 ppm PASS 7700

Manganese (Mn) < 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 5.7 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 24: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 24 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3

6-Green foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.7 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.5 ppm PASS 70000

Boron (B) 0.6 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 7.5 ppm PASS 7700

Manganese (Mn) < 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 5.5 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 25: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 25 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3

7-Red foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 12.8 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 2.3 ppm PASS 70000

Boron (B) 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.2 ppm PASS 7700

Manganese (Mn) 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 0.4 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1.2 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 26: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 26 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

1-Multicolor cartoon RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 1.5 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 3.1 ppm PASS 70000

Boron (B) 2 ppm PASS 15000

Cobalt (Co) 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 8.7 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 40.2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) < 0.1 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 27: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 27 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

2-Green foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.6 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.1 ppm PASS 70000

Boron (B) 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 1.2 ppm PASS 7700

Manganese (Mn) 0.8 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 2.2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 72.9 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 28: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 28 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

3-Light green foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.9 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.8 ppm PASS 7700

Manganese (Mn) 0.5 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 70.7 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 29: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 29 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

4-Orange foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 7.3 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) < 0.1 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.5 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1.3 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 27 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 30: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 30 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

5-Red foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 6.5 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) < 0.1 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.3 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 28.2 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 31: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 31 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

6-Yellow foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.6 ppm PASS 70000

Boron (B) 0.5 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.4 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1.2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 34.8 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 32: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 32 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

7-White foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.5 ppm PASS 70000

Boron (B) 0.3 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.2 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 31.3 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 33: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 33 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4

8-Purple foam RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) < 0.1 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.5 ppm PASS 70000

Boron (B) 0.2 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.9 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 1.3 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 73 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 34: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 34 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

1-Black, white cartoon RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 20.6 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 0.3 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) 0.4 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 43.4 ppm PASS 70000

Boron (B) 17.8 ppm PASS 15000

Cobalt (Co) 0.4 ppm PASS 130

Copper (Cu) 1.6 ppm PASS 7700

Manganese (Mn) 41.8 ppm PASS 15000

Nickel (Ni) 0.9 ppm PASS 930

Strontium (Sr) 45.2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 10 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 35: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 35 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

2-Pink chenille RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.3 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 3.9 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) 0.4 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 1.6 ppm PASS 70000

Boron (B) 3.2 ppm PASS 15000

Cobalt (Co) 0.8 ppm PASS 130

Copper (Cu) 0.3 ppm PASS 7700

Manganese (Mn) 50 ppm PASS 15000

Nickel (Ni) 2.8 ppm PASS 930

Strontium (Sr) 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1502.4 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 36: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 36 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

3-Orange chenille RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 3.3 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) 0.3 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 2 ppm PASS 70000

Boron (B) 3.5 ppm PASS 15000

Cobalt (Co) 0.5 ppm PASS 130

Copper (Cu) 0.1 ppm PASS 7700

Manganese (Mn) 46.7 ppm PASS 15000

Nickel (Ni) 2.2 ppm PASS 930

Strontium (Sr) 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1366 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 37: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 37 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

4-Green chenille RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.2 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 2 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.5 ppm PASS 70000

Boron (B) 1.8 ppm PASS 15000

Cobalt (Co) 0.6 ppm PASS 130

Copper (Cu) 1 ppm PASS 7700

Manganese (Mn) 56.8 ppm PASS 15000

Nickel (Ni) 1 ppm PASS 930

Strontium (Sr) 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 999.6 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 38: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 38 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

5-Blue chenille RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 0.6 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.3 ppm PASS 70000

Boron (B) 2.1 ppm PASS 15000

Cobalt (Co) 0.2 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 33.4 ppm PASS 15000

Nickel (Ni) 0.2 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1013.9 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 39: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 39 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

6-Purple chenille RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 0.5 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.1 ppm PASS 70000

Boron (B) 2 ppm PASS 15000

Cobalt (Co) 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 35 ppm PASS 15000

Nickel (Ni) 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 1002 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 40: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 40 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

7-Yellow chenille RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 1.8 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 0.4 ppm PASS 70000

Boron (B) 1.8 ppm PASS 15000

Cobalt (Co) 0.4 ppm PASS 130

Copper (Cu) 0.8 ppm PASS 7700

Manganese (Mn) 55.2 ppm PASS 15000

Nickel (Ni) 0.7 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 980.8 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 41: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 41 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

8-Pink glitter RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.5 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 0.7 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 16.3 ppm PASS 70000

Boron (B) 2.4 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.3 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) 0.2 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 4 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 42: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 42 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

9-Yellow glitter RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) 0.4 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 0.6 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 17.1 ppm PASS 70000

Boron (B) 2 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) < 0.1 ppm PASS 7700

Manganese (Mn) 0.1 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 3.7 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 43: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 43 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

10-Green glitter RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) < 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 0.6 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 30.6 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.3 ppm PASS 7700

Manganese (Mn) 0.3 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 0.8 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 44: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 44 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5

11-Blue glitter RESULT (ppm) PASS/FAIL

REQUIREMENT (ppm)

Antimony (Sb) < 0.1 ppm PASS 560

Arsenic (As) < 0.1 ppm PASS 47

Barium (Ba) < 0.1 ppm PASS 18750

Cadmium (Cd) < 0.1 ppm PASS 17

Chromium (III) 0.6 ppm PASS 460

Chromium (VI) < 0.1 ppm PASS 0,2

Lead (Pb) < 0.1 ppm PASS 160

Mercury (Hg) < 0.01 ppm PASS 94

Selenium (Se) < 0.1 ppm PASS 460

Aluminium (Al) 31.4 ppm PASS 70000

Boron (B) < 0.1 ppm PASS 15000

Cobalt (Co) < 0.1 ppm PASS 130

Copper (Cu) 0.2 ppm PASS 7700

Manganese (Mn) 0.5 ppm PASS 15000

Nickel (Ni) < 0.1 ppm PASS 930

Strontium (Sr) < 0.1 ppm PASS 56000

Tin (Sn) < 0.1 ppm PASS 180000

Organic tin < 0.1 ppm PASS 12

Zinc (Zn) 0.6 ppm PASS 46000

ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm

Page 45: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 45 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

Page 46: TEST REPORT€¦ · Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yenibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55 e-mail : intertekcg.turkiye@intertek.com

.

R E S U L T S Page 46 of 46 REPORT :TURT130111122 30 July, 2013

Test Method Result Requirements

Intertek Test Hizmetleri A.S .

Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55

e-mail : [email protected] www.intertek-cg-tur.com

## END OF TEST REPORT ##