test report€¦ · merkez mahallesi sanayi cad. no.23 altindag plaza yenibosna 34197 - istanbul /...
TRANSCRIPT
.
TEST REPORT Page 1 of 46
Beril SEN Sinan Öncel COORDINATOR CUSTOMER CARE MANAGER
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Y enibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
*130111122* 130111122
ebru.aslan
REPORT NUMBER : TURT130111122
APPLICANT NAME Ceren Kağıt ve Kırtasiye San. A. Ş.
ADDRESS Ziya Gökalp Mah. Eski Turgut Özal Cad. Haseyad İş Merkezi İ.O.S.B Başakşehir / İstanbul TURKEY FAX NO :0212 407 06 66
Attention :Berçem Keresteci (bercem@cerenkirtasiye .com.tr)
BUYER NOT GIVEN
SAMPLE DESCRIPTION : Sample 1 Two samples of Eva hoby set foam picture art with picture guide&foam stickers / BU-
BU00079 - CA9246ABCDEF Sample 2 Two samples of Mosaic hoby set sparkle mosaic art mosaic picture&adhesive mosaic tiles /
BU-BU00080 - CA8922 Sample 3 Two samples of pon pon hoby set pompom art with picture base adhesive paper and pom
poms / BU-BU00076 - CA8396ABCD Sample 4 Two samples of Eva hoby set foam art with picture guide&foam stickers / BU-BU00077 -
CA9260 Sample 5 Two samples of Silverly poufs glitter loop&curl with adhesive picture design glitter and
chenilles / BU-BU00078 - CA9259
DATE IN : 19 July, 2013 (15:58)
DATE OUT : 30 July, 2013
COUNTRY OF ORIGIN: CHINA
ITEM NO: BU-BU00079 - CA9246ABCDEF / BU-BU00080 - CA8922 / BU-BU00076 - CA8396ABCD / BU-BU00077 - CA9260 / BU-BU00078 - CA9259
TEST Sample 1 Sample 2 Sample 3 Sample 4 Sample 5
SAFETY OF TOYS-PART 1:MECHANICAL AND PHYSICAL PROPERTIES
P (Except 7.1)
P (Except 7.1)
P (Except 7.1)
P (Except 7.1)
P (Except 7.1)
SAFETY OF TOYS-PART 2:FLAMMABILITY P P P P P TOXIC ELEMENTS ANALYSIS P P P P P P = MEETS BUYER' S REQUIREMENT / F = DOES NOT MEET BUYER' S REQUIREMENT / NR = NO REQUIREMENT / SC=STILL CONTINUES / X=NOT PERFORMED / NA = NOT APPLICABLE/ LS : LACK OF SAMPLE The test results relate only to the items tested. The whole and/or the part of this test report shall not be reproduced and shall not be shared with third parties, nor to be used for PR activities without the written permission of INTERTEK Test Hizmetleri A.S. The reported uncertainity is based on a standard uncertainity multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%. The uncertainity evaluation has been carried out in accordance with ISO/IEC 17025 and UKAS accreditation requirements. Unless otherwise is specified, all Pass or Fail results are given without uncertainity considered. When uncertainity is taken into account, the result may be borderline. Borderline results need to be re-tested to determine their disposition up to customer’s decision. Opinions and interpretations expressed herein are outside the scope of UKAS accreditation. Tests marked (*) in this test report are not included in the UKAS accreditation schedule for this laboratory.
.
R E S U L T S Page 2 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
This report details the clauses appropriate to this item. Those clauses not referred to were considered not applicable.
Specification: BS EN 71-1: 2011- Safety of Toys - S pecification for Mechanical and Physical Properties The item was labelled “Warning! Choking hazard small parts not for children under 3 years.”. The item was tested for children aged over 36 months. The item was packaging in a cardboard box which was considered to be disposable.
Sample 1&2
SECTION TEST RESULTS
4 General Requirements
4.1 Material Pass
4.7 Edges Pass
4.8 Points & Metallic Wires Pass
7 Warning and Instruction for Use
7.1 General
The toy or, its packaging or document accompanying must be labelled with:
- The name and address of the manufacturer.** - Warning and other information should be in the national language(s) of the countries where the toy is marketed.
**In the case of the toy sell in European countries, the toy, its packaging or document accompanying must be labelled with the name and address of the manufacturer and importer.
*The importer name is not clearly pointed out as importer It’s recomended to be identified with the title of ‘importer’.
See Comment
7.2 Toys not intended for children under 36 months
The graphical symbol was found to be incorrect (Too small) as the item bore a suitable text warning this clause is considered to pass however we recommend that the graphical symbol is either corrected or removed from the packaging.
Pass
See Comment
.
R E S U L T S Page 3 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
This report details the clauses appropriate to this item. Those clauses not referred to were considered not applicable.
Specification: BS EN 71-1: 2011- Safety of Toys - S pecification for Mechanical and Physical Properties The item was labelled “Warning! Choking hazard small parts not for children under 3 years.”. The item was tested for children aged over 36 months. The item was packaging in a cardboard box which was considered to be disposable.
Sample 3&4&5
SECTION TEST RESULTS
4 General Requirements
4.1 Material Pass
4.7 Edges Pass
4.8 Points & Metallic Wires Pass
7 Warning and Instruction for Use
7.1 General
The toy or, its packaging or document accompanying must be labelled with:
- The name and address of the manufacturer.** - Warning and other information should be in the national language(s) of the countries where the toy is marketed.
**In the case of the toy sell in European countries, the toy, its packaging or document accompanying must be labelled with the name and address of the manufacturer and importer.
*The importer name is not clearly pointed out as importer It’s recomended to be identified with the title of ‘importer’.
See Comment
7.2 Toys not intended for children under 36 months Pass
.
R E S U L T S Page 4 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*)Specification: BS EN 71-2: 2011 Safety of Toys – Flammability Sample 1&2&3&4&5
SECTION TEST RESULTS
4.1 General
Celluloid/cellulose nitrate and materials with a same burning behaviour in fire Pass
.
R E S U L T S Page 5 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1
1-Multicolor cartoon RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 1.2 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 2.8 ppm PASS 70000
Boron (B) 2 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 6.8 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 44.9 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) < 0.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 6 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1
2-Red foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 9.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.1 ppm PASS 70000
Boron (B) 1.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 1 ppm PASS 7700
Manganese (Mn) 0.7 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1.9 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 88.7 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 7 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1
3-Orange foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 10 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.3 ppm PASS 70000
Boron (B) 1.2 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 1.2 ppm PASS 7700
Manganese (Mn) 0.8 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 2.2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 90 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 8 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1
4-Yellow foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.6 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.7 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.3 ppm PASS 7700
Manganese (Mn) 0.5 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 70.2 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 9 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 1
5-Blue foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.5 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.3 ppm PASS 7700
Manganese (Mn) 0.3 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1.2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 72 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 10 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
1-Red rhinestones RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.8 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.5 ppm PASS 70000
Boron (B) 0.2 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.1 ppm PASS 7700
Manganese (Mn) 1.4 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 2.8 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) < 0.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 11 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
2-Blue rhinestones RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.7 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.4 ppm PASS 70000
Boron (B) 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 1.4 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 2.5 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) < 0.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 12 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
3-Purple rhinestones RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.8 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.2 ppm PASS 70000
Boron (B) 0.2 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.1 ppm PASS 7700
Manganese (Mn) 1.3 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) < 0.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 13 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
4-Red shinny foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.8 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) < 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 7.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 14 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
5-Yellow shinny foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) < 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.9 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) < 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 6.8 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 15 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
6-Green shinny foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.3 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.3 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) < 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1.5 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 16 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
7-Blue shinny foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.2 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) < 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1.2 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 17 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
8-Pink shinny foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.7 ppm PASS 70000
Boron (B) 0.3 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.5 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 2.5 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 18 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 2
9-Multicolor cartoon RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.9 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.3 ppm PASS 70000
Boron (B) 0.9 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 6.4 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 46.3 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) < 0.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 19 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3
1-Multicolor cartoon RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 4.6 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 8.3 ppm PASS 70000
Boron (B) 3.1 ppm PASS 15000
Cobalt (Co) 0.3 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 19.7 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 44.4 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1.2 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 20 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3
2-Black, white cartoon RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 7.5 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 6.4 ppm PASS 70000
Boron (B) 94.3 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 8 ppm PASS 15000
Nickel (Ni) 0.1 ppm PASS 930
Strontium (Sr) 60 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 0.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 21 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3
3-Yellow foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.3 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.4 ppm PASS 70000
Boron (B) 0.2 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.4 ppm PASS 7700
Manganese (Mn) 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 2.4 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 22 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3
4-White foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) < 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.2 ppm PASS 70000
Boron (B) 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.3 ppm PASS 7700
Manganese (Mn) < 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 2 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 23 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3
5-Blue foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.7 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.9 ppm PASS 70000
Boron (B) 0.8 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 7.7 ppm PASS 7700
Manganese (Mn) < 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 5.7 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 24 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3
6-Green foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.7 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.5 ppm PASS 70000
Boron (B) 0.6 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 7.5 ppm PASS 7700
Manganese (Mn) < 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 5.5 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 25 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 3
7-Red foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 12.8 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 2.3 ppm PASS 70000
Boron (B) 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.2 ppm PASS 7700
Manganese (Mn) 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 0.4 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1.2 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 26 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
1-Multicolor cartoon RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 1.5 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 3.1 ppm PASS 70000
Boron (B) 2 ppm PASS 15000
Cobalt (Co) 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 8.7 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 40.2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) < 0.1 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 27 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
2-Green foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.6 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.1 ppm PASS 70000
Boron (B) 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 1.2 ppm PASS 7700
Manganese (Mn) 0.8 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 2.2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 72.9 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 28 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
3-Light green foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.9 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.8 ppm PASS 7700
Manganese (Mn) 0.5 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 70.7 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 29 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
4-Orange foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 7.3 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) < 0.1 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.5 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1.3 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 27 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 30 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
5-Red foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 6.5 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) < 0.1 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.3 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 28.2 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 31 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
6-Yellow foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.6 ppm PASS 70000
Boron (B) 0.5 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.4 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1.2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 34.8 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 32 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
7-White foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.5 ppm PASS 70000
Boron (B) 0.3 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.2 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 31.3 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 33 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 4
8-Purple foam RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) < 0.1 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.5 ppm PASS 70000
Boron (B) 0.2 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.9 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 1.3 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 73 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 34 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
1-Black, white cartoon RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 20.6 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 0.3 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) 0.4 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 43.4 ppm PASS 70000
Boron (B) 17.8 ppm PASS 15000
Cobalt (Co) 0.4 ppm PASS 130
Copper (Cu) 1.6 ppm PASS 7700
Manganese (Mn) 41.8 ppm PASS 15000
Nickel (Ni) 0.9 ppm PASS 930
Strontium (Sr) 45.2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 10 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 35 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
2-Pink chenille RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.3 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 3.9 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) 0.4 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 1.6 ppm PASS 70000
Boron (B) 3.2 ppm PASS 15000
Cobalt (Co) 0.8 ppm PASS 130
Copper (Cu) 0.3 ppm PASS 7700
Manganese (Mn) 50 ppm PASS 15000
Nickel (Ni) 2.8 ppm PASS 930
Strontium (Sr) 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1502.4 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 36 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
3-Orange chenille RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 3.3 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) 0.3 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 2 ppm PASS 70000
Boron (B) 3.5 ppm PASS 15000
Cobalt (Co) 0.5 ppm PASS 130
Copper (Cu) 0.1 ppm PASS 7700
Manganese (Mn) 46.7 ppm PASS 15000
Nickel (Ni) 2.2 ppm PASS 930
Strontium (Sr) 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1366 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 37 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
4-Green chenille RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.2 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 2 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.5 ppm PASS 70000
Boron (B) 1.8 ppm PASS 15000
Cobalt (Co) 0.6 ppm PASS 130
Copper (Cu) 1 ppm PASS 7700
Manganese (Mn) 56.8 ppm PASS 15000
Nickel (Ni) 1 ppm PASS 930
Strontium (Sr) 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 999.6 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 38 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
5-Blue chenille RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 0.6 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.3 ppm PASS 70000
Boron (B) 2.1 ppm PASS 15000
Cobalt (Co) 0.2 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 33.4 ppm PASS 15000
Nickel (Ni) 0.2 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1013.9 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 39 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
6-Purple chenille RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 0.5 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.1 ppm PASS 70000
Boron (B) 2 ppm PASS 15000
Cobalt (Co) 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 35 ppm PASS 15000
Nickel (Ni) 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 1002 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 40 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
7-Yellow chenille RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 1.8 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 0.4 ppm PASS 70000
Boron (B) 1.8 ppm PASS 15000
Cobalt (Co) 0.4 ppm PASS 130
Copper (Cu) 0.8 ppm PASS 7700
Manganese (Mn) 55.2 ppm PASS 15000
Nickel (Ni) 0.7 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 980.8 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 41 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
8-Pink glitter RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.5 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 0.7 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 16.3 ppm PASS 70000
Boron (B) 2.4 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.3 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) 0.2 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 4 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 42 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
9-Yellow glitter RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) 0.4 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 0.6 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 17.1 ppm PASS 70000
Boron (B) 2 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) < 0.1 ppm PASS 7700
Manganese (Mn) 0.1 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 3.7 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 43 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
10-Green glitter RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) < 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 0.6 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 30.6 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.3 ppm PASS 7700
Manganese (Mn) 0.3 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 0.8 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 44 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
(*) Toxic Elements Analysis PR EN 71-3 : 2013 Acid extraction method determined by Inductively Coupled Plasma – Mass Spectrometer (ICP / MS) Sample 5
11-Blue glitter RESULT (ppm) PASS/FAIL
REQUIREMENT (ppm)
Antimony (Sb) < 0.1 ppm PASS 560
Arsenic (As) < 0.1 ppm PASS 47
Barium (Ba) < 0.1 ppm PASS 18750
Cadmium (Cd) < 0.1 ppm PASS 17
Chromium (III) 0.6 ppm PASS 460
Chromium (VI) < 0.1 ppm PASS 0,2
Lead (Pb) < 0.1 ppm PASS 160
Mercury (Hg) < 0.01 ppm PASS 94
Selenium (Se) < 0.1 ppm PASS 460
Aluminium (Al) 31.4 ppm PASS 70000
Boron (B) < 0.1 ppm PASS 15000
Cobalt (Co) < 0.1 ppm PASS 130
Copper (Cu) 0.2 ppm PASS 7700
Manganese (Mn) 0.5 ppm PASS 15000
Nickel (Ni) < 0.1 ppm PASS 930
Strontium (Sr) < 0.1 ppm PASS 56000
Tin (Sn) < 0.1 ppm PASS 180000
Organic tin < 0.1 ppm PASS 12
Zinc (Zn) 0.6 ppm PASS 46000
ppm (Part per million) =mg / kg < =Less Than ND =Not Detected Detection Limit =Mercury (Hg): <0.01 ppm, Others metal: <0.1 ppm
.
R E S U L T S Page 45 of 46 REPORT :TURT130111122 30 July, 2013
Test Method Result Requirements
Intertek Test Hizmetleri A.S .
Merkez Mahallesi Sanayi Cad. No.23 Altindag Plaza Yen ibosna 34197 - ISTANBUL / TURKEY Phone : +90.212. 496 46 46 Fax: +90.212. 452 80 55
e-mail : [email protected] www.intertek-cg-tur.com
.
R E S U L T S Page 46 of 46 REPORT :TURT130111122 30 July, 2013